• Title/Summary/Keyword: Bhabha

Search Result 122, Processing Time 0.026 seconds

Assaying of SNM using Simultaneous Detection of Fission Neutrons and Gammas by Employing a Novel Phoswich Detector

  • Sonu;Mohit Tyagi;A. Kelkar;A. Sahu;M. Sonawane;P.S. Sarkar;A. Pandey;D.B. Sathe;G.D. Patra;T. Vincent;S.G. Singh;R.B. Bhatt
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2662-2669
    • /
    • 2023
  • For the precise measurements of special nuclear materials (SNM) including Pu and Am isotopes, we have used phoswich detector combination of two single crystal scintillators of Gd3Ga3Al2O12:Ce and CsI:Tl. High detection efficiency and sensitivity along with high figure of merit for the discrimination of these phoswich detectors ensures the detection and discrimination of thermal neutrons and gammas from spontaneous fission of Pu and other isotopes in presence of high gamma background. Using this detector, the low energy gammas, which is stopped completely in 1mm thick disc of GGAG, can be also discriminated from high energies gamma and shows linearity in wide range of sample quantities. By changing only the appropriate shielding, the similar setup was used for thermal neutron detection and shows a very good linearity over wide range. The quantity of a test sample was also calculated accurately by using the measured calibrated plot.

Investigation of transport of radionuclide in a thermal stratification test facility using radiotracer technique

  • Pant, Harish Jagat;Goswami, Sunil;Chafle, Sunil B.;Sharma, Vijay Kumar;Kotak, Vimal;Shukla, Vikram;Mishra, Amitanshu;Gohel, Nilesh C.;Bhattacharya, Sujay
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1449-1455
    • /
    • 2022
  • A radiotracer investigation was carried out in a Thermal Stratification Test Facility (TSTF) with objectives of investigating the dispersion and diffusion of radionuclide and effectiveness of the thermocline to minimize the radionuclide content in the hot water layer. Technetium-99m (99mTc) as sodium pertechnetate was used as a radiotracer in the investigation. Qualitative analysis showed that a thermocline is formed within the TSTF and is effective in preventing the transport of radionuclide from bottom section to the top section of the facility. It was found that the radiotracer injected at the bottom of the pool took about 17.4 h to disperse from bottom to the top of the facility. The results of the investigation helped in understanding the effectiveness of hot water layer and thus to minimize the pool top radiation levels.

AN ENGINEERING SCALE STUDY ON RADIATION GRAFTING OF POLYMERIC ADSORBENTS FOR RECOVERY OF HEAVY METAL IONS FROM SEAWATER

  • Prasad, T.L.;Saxena, A.K.;Tewari, P.K.;Sathiyamoorthy, D.
    • Nuclear Engineering and Technology
    • /
    • v.41 no.8
    • /
    • pp.1101-1108
    • /
    • 2009
  • The ocean contains around eighty elements of the periodic table and uranium is also one among them, with a uniform concentration of 3.3 ppb and a relative abundance factor of 23. With a large coastline, India has a large stake in exploiting the 4 billion tonnes of uranium locked in seawater. The development of radiation grafting techniques, which are useful in incorporating the required functional groups, has led to more efficient adsorbent preparations in various geometrical configurations. Separation based on a polymeric adsorbent is becoming an increasingly popular technique for the extraction of trace heavy metals from seawater. Radiation grafting has provided definite advantages over chemical grafting. Studies related to thermally bonded non woven porous polypropylene fiber sheet substrate characterization and parameters to incorporate specific groups such as acrylonitrile (AN) into polymer back bones have been investigated. The grafted polyacrylonitrile chains were chemically modified to convert acrylonitrile group into an amidoxime group, a chelating group responsible for heavy metal uptake from seawater/brine. The present work has been undertaken to concentrate heavy metal ions from lean solutions from constant potential sources only. A scheme was designed and developed for investigation of the recovery of heavy metal ions such as uranium and vanadium from seawater.

RADAR level measurement in Joule heated ceramic melter: A novel technique

  • Suneel, G.;Mahashabde, Mukesh;Borkotoky, Ritusmita;Sharma, Nitin Kumar;Pradeep, M.P.;Gayen, J.K.;Pimparkar, H.R.;Ravi, K.V.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1176-1180
    • /
    • 2021
  • The current study relates to RADAR (RAdio Detection and Ranging) application for level measurement of vitrified radioactive liquid nuclear waste. The vitrification of radioactive liquid waste is carried out in special equipment called 'Melters'. The study is directed towards the design and frequency modulation used in the level measurement of vitrified waste. More specifically, the RADAR design and frequency used for level measurement in a melter. This level measurement technique can also be used for dynamic vitrification process and can be used to measure the level variations without using any external medium/material and using only electromagnetic waves. Also, this technique is durable and accurate even under the high radioactive environment present inside the melter.

X-RAY ASTRONOMY EXPERIMENT ON THE INDIAN SATELLITE IRS-P3

  • AGRAWAL P. C.;PAUL B.;RAO A. R.;SHAH M. R.;MCKERJEE K.;VARIA M. N.;YADAV J. S.;DEDHIA D. K.;MALKAR J. P.;SHAH P.;DAMLE S. V.;MARAR T. M. K.;SEETHA S.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.429-432
    • /
    • 1996
  • An x-ray astronomy experiment consisting of three collimated proportional counters and an X-ray Sky Monitor (XSM) was flown aboard the Indian Satellite IRS-P3 launched on March 21, 1996 from SHAR range in India. The Satellite is in a circular orbit of 830 km altitude with an orbital inclination of $98^{\circ}$ and has three axis stabilized pointing capability. Each pointed-mode Proportional Counter (PPC) is a multilayer, multianode unit filled with P-10 gas ($90\%$ Ar + $10\%\;CH_4$) at 800 torr and having an aluminized mylar window of 25 micron thickness. The three PPCs are identical and have a field of view of $2^{\circ}{\times}2^{\circ}$ defined by silver coated aluminium honeycomb collimators. The total effective area of the three PPCs is about 1200 $cm^2$. The PPCs are sensitive in 2-20 keV band. The XSM consists of a pin-hole of 1 $cm^2$ area placed 16 cm above the anode plane of a 32 cm$\times$32 cm position sensitive proportional counter sensitive in 3-8 keV interval. The position of the x-ray events is determined by charge division technique using nichrome wires as anodes. The principal objective of this experiment is to carry out timing studies of x-ray pulsars, x-ray binaries and other rapidly varying x-ray sources. The XSM will be used to detect transient x-ray sources and monitor intensity of bright x-ray binaries. Observations of black-hole binary Cyg X-1 and few other binary sources were carried out in early May and July-August 1996 period. Details of the x-ray detector characteristics are presented and preliminary results from the observations are discussed.

  • PDF

Fluid-structure interaction analysis of sloshing in an annular - sectored water pool subject to surge motion

  • Eswaran, M.;Goyal, P.;Reddy, G.R.;Singh, R.K.;Vaze, K.K.
    • Ocean Systems Engineering
    • /
    • v.3 no.3
    • /
    • pp.181-201
    • /
    • 2013
  • The main objective of this work is to investigate the sloshing behavior in a baffled and unbaffled three dimensional annular-sectored water pool (i.e., tank) which is located at dome region of the primary containment. Initially two case studies were performed for validation. In these case studies, the theoretical and experimental results were compared with numerical results and good agreement was found. After the validation of present numerical procedure, an annular-sectored water pool has been taken for numerical investigation. One sector is taken for analysis from the eight sectored water pool. The free surface is captured by Volume of Fluid (VOF) technique and the fluid portion is solved by finite volume method while the structure portions are solved by finite element approach. Baffled and un-baffled cases were compared to show the reduction in wave height under excitation. The complex mechanical interaction between the fluid and pool wall deformation is simulated using a partitioned strong fluid-structure coupling.