• 제목/요약/키워드: Bending joint

Search Result 437, Processing Time 0.027 seconds

Bending Strain Dependence of the Transport Property in Jointed BSCCO Tapes

  • Dedicatoria, Marlon J.;Shin, Hyung-Seop
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.2
    • /
    • pp.5-8
    • /
    • 2010
  • In this study, the effect of bending strain on the transport property and critical current of lap and butt-jointed (non-laminated) BSCCO tapes has been investigated. The samples were joined using a mechanically controlled jointing procedure. To achieve a uniform thickness at the joint a single point loading contact has been devised. GFRP mandrels with different bending radii which support the sample during bending have been used. $I_c$ have been measured at 77 K and self field. In the case of easy bending test for jointed BSCCO tapes, sudden degradation of $I_c$ is caused by the local strain concentration due to non uniform deformation at the edge parts of the joint. In the case of hard bending test of jointed BSCCO tapes transverse macroscopic crack at specific subsection caused a large $I_c$ degradation. The transport property of jointed BSCCO tapes in each bending mode was discussed with the damage morphology occurred.

Effect of Thermal Cycle on Strength of Ceramic and Metal Joint (세라믹/금속접합재의 강도에 미치는 열사이클 영향)

  • 박영철;오세욱;김광영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.7
    • /
    • pp.1664-1673
    • /
    • 1994
  • As a fundamental study on effects of thermal-cycles on residual stress of ceramics/metal joints, residual stresses in $Si_3N_4$/SUS304 joint specimens were measured before and single thermal-cycle by X-ray diffraction method and finite element method(FEM). The residual stress was found to increase after single thermal-cycle, which was agreeable with the results of residual stress measurement by X-ray diffraction method and residual stress analysis by finite element method. After the residual stress measurement, 4-point bending tests were performed. The relationship between the bending strength, the thermal-cycle temperature and hold time was examined. The bending strength was found to decrease with the increase of residual stress in linear relation.

Clinical outcomes of bending versus non-bending of the plate hook in acromioclavicular joint dislocation

  • Joo, Min Su;Kwon, Hoi Young;Kim, Jeong Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.4
    • /
    • pp.202-208
    • /
    • 2021
  • Background: We aimed to assess the effect of plate hook bending in treatment of acromioclavicular (AC) dislocation by analyzing clinical and radiological results according to the angle of the plate hook (APH). Methods: This was a retrospective, observational, case-control study including 76 patients with acute AC joint dislocation that were divided into two groups according to treatment with bent or unbent plate hook. The visual analog scale (VAS), the American Shoulder and Elbow Surgeons (ASES) shoulder score, and range of motion (ROM) were evaluated as clinical outcomes. Comparative coracoclavicular distance (CCD) was measured to evaluate radiological outcomes. Results: While the VAS and ASES of the bending group at 4 months after surgery were significantly higher (p=0.021 and p=0.019), the VAS and ASES of the bending group at other periods and ROM of the bending group showed no significant difference. The initial CCD decreased from 183.2%±25.4% to 114.3%±18.9% at the final follow-up in the bending group and decreased from 188.2%±34.4% to 119.1%±16.7% in the non-bending group, with no statistical difference (p=0.613). The changes between the initial and post-metal removal CCD were 60.2%±11.2% and 57.3%±10.4%, respectively, with no statistical difference (p=0.241). The non-bending group showed greater subacromial osteolysis (odds ratio, 3.87). Pearson's coefficients for the correlation between APH and VAS at 4 months after surgery and for that between APH and ASES at 4 months after surgery were 0.74 and -0.63 (p=0.027 and p=0.032), respectively. Conclusions: The APH was associated with improved postoperative pain and clinical outcomes before implant removal and with reduced complications; therefore, plate hook bending is more useful clinically during plate implantation.

Vibration Analysis of Expansion Joint with Rotary Inertia Using Transfer Matrix Method (전달행렬법을 이용하여 회전관성을 고려한 Expansion Joint의 진동해석)

  • Shin, Dong-Ho;Oh, Jae-Eung;Lee, Jung-Youn
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.544-549
    • /
    • 2011
  • Simplified formulae for axial and bending natural frequencies of bellows are developed using an equivalent thin-walled pipe model. The axial and bending stiffness of bellows is determined using lumped transfer matrix method. Accordingly, the Expansion Joint Manufacturers Association (EJMA) formula for axial and bending stiffness calculation is modified using two different equivalent radii. The results from the simplified formulae are verified by those from a experiment result and a finite element (FE) model and good agreement is shown between the each other.

  • PDF

Fatigue Assessment of Hybrid Composite Joint for the Tilting Car Body (틸팅 차량용 차체의 하이브리드 복합재 접합체결부의 내구성 평가)

  • Jung, Dal-Woo;Choi, Nak-Sam;Kim, Jung-Seok;Seo, Sueng-Il;Jo, Se-Hyun
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2006.05a
    • /
    • pp.357-361
    • /
    • 2006
  • Fatigue fracture behavior of a hybrid joint part with bolting was evaluated in comparison to the case of static fracture. Hybrid joint part specimens for bending test were made with layers of CFRP and aluminum honeycomb. Characteristic fracture behaviors of those specimens were obviously different under static and cyclic loads. Static bending load showed the shear deformation at the honeycomb core, whereas cyclic bending load caused the delamination between CFRP skin layers and honeycomb core. Experimental results obtained by static and fatigue tests were considered in modifications of design parameters of the hybrid joint.

  • PDF

Residual Stress Analysis in Bi-material Metal Joint under Bending Moment by Finite Element Method (이종재료 금속조인트의 굽힘에 의한 잔류응력 해석)

  • Baek Tae-Hyun;Jung Girl;Park Tae-Geun
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.448-451
    • /
    • 2005
  • It was observed that after unloading or removal of the load from the specimen subjected to bending stress, partial or full elastic spring back occurred and considerable stresses have resulted while plastic deformation was considered. ABAQUS is a suite of powerful engineering simulation programs, based on the finite element method. In this paper, it was used as the main tool to analyze elastic and plastic deformations of hi-material metal joint. In the case of elastic deformations, the results were comparable to the theoretical data. Plastic deformations and residual stresses of hi-material metal joint under bending moment were obtained by ABAQUS; where the theory needs to be studied and improved further to verify the results.

  • PDF

Change of Lumbar Spine and Hip Joint Flexion Angles During Forward Bending of the Trunk Using Manual Facilitation and a Stick (도수 촉진과 막대를 이용한 몸통의 전방 굴곡 운동에 따른 요추와 고관절 굴곡 각도의 변화)

  • Choung, Sung-Dae;Park, Kyue-Nam;Hong, Ji-A;Cho, Min-Sue;Son, Dong-Hwi;Cynn, Heon-Seock
    • Physical Therapy Korea
    • /
    • v.18 no.1
    • /
    • pp.57-63
    • /
    • 2011
  • The purpose of this study was to identify the effects of manual facilitation and a stick on lumbar and hip joint flexion angles in subject with lumbar flexion syndrome during forward bending from a sitting position. Fifteen subjects with lumbar flexion syndrome were recruited for this study. As a pretest, all subjects performed three repetitions of bending the trunk forward until the tips of their fingers touched the target bar. After this pretest, the subjects practiced the forward bending of the trunk 10 times, using either manual facilitation or a stick. Then, as a posttest, all subjects repeated the pretest procedure. The flexion angles of lumbar spine and hip joint during forward bending in a sitting position were measured using a three-dimensional motion analysis system. A paired t-test was used to determine the statistical differences between pre-test and post-test flexion angles and pre- and post-test flexion angle differences between forward bending with manual facilitation and forward bending with a stick. The level of statistical significance was set at p=.05. The results of the study showed that the angle of the lumbar flexion decreased significantly and the bilateral hip flexion angle increased significantly when performing forward bending with stick and manual facilitation. Furthermore, the angle of lumbar flexion decreased significantly and the angle of bilateral hip flexion increased significantly in forward bending with a stick compared to forward bending with manual facilitation. The findings of this study indicate that both forward bending with manual facilitation and sticks could be used to prevent excessive lumbar flexion and increase hip flexion, and that forward bending with a stick is more effective than forward bending with manual facilitation for inducing lumbar spine and hip joint angle changes.

Measurement and Therapy of Abnormalities in Joint Flexion of the Thumb (엄지손가락의 관절 굽힘의 이상 측정 및 치료)

  • Rhee, Yang-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.10
    • /
    • pp.1355-1360
    • /
    • 2018
  • The healthcare industry is expected to the range of services will be expanded and management will be done throughout the life cycle by combining Big Data, Information and Communications Technologies (ICT), and IT equipment. This paper describes a metacarpophalangeal joint flexion and interphalangeal joint flexion of the thumb as one area of healthcare. Metacarpophalangeal joint flexion refers to bending the thumb metacarpophalangeal joint, and interphalangeal joint flexion refers to bending the thumb interphalangeal joint. When bending the joints, if the angle is below a certain angle, or if you feel pain, you have an abnormality. In addition, prevention and therapy of the thumb joint were also suggested. Experiments were performed on metacarpophalangeal joint flexion and interphalangeal joint flexion in the thumb joint in the case of 50 people in their 50s. The system is limited to a portion of the body, but if it is partially expanded, it will be the basis for building a Big Data healthcare system.

Prediction of Bending Angle of Bellows and Stability Analysis of Pipeline Using the Prediction (벨로우즈형 신축관이음의 휨각도 예측 및 이를 이용한 배관계의 안정성 해석)

  • Son, In-Soo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.827-833
    • /
    • 2022
  • In this study, the prediction of the bending angle for the 350 A bellows-type expansion joints and the structural stability according to the load were determined. The stability of the 2km piping system was predicted by applying the allowable bending angle of the expansion pipe joint obtained from the analysis. The maximum bending angle was calculated through bending analysis of the bellows-type expansion joints, and the maximum bending angle by numerical calculation was about 1.8°, and the maximum bending angle of the bellows obtained by comparing the allowable strength of the material was about 0. 22°. This angle was very stable compared to the allowable bending angle (3°) of the expansion pipe joint regulation. By applying the maximum bending angle, the allowable maximum deflection of the 2 km pipe was about 3.8 m. When the seismic load was considered using regression analysis, the maximum deflection of the 2km pipe was about 142.3mm, and it was confirmed that the bellows-type expansion joints and the deflection were stable compared to the allowable maximum deflection of the pipe system. These research results are expected to present design and analysis guidelines for the construction of piping and the development of bellows systems, and to be used as basic data for systematic research.

The Effectiveness of Joint Mobilization and Myofascial Release on the Neck (관절가동기법과 근막이완기법이 경부에 미치는 영향)

  • Park, Youn-Ki;Hyun, Sang-Wook;Seo, Hyun-Kyu
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.15 no.2
    • /
    • pp.69-79
    • /
    • 2009
  • Purpose : to investigate the effectiveness of joint mobilization and myofascial release on the neck pain and to provide the effective treatment. Methods : Twenty-two subjects with neck pain participated in the experiment. All subjects were randomly assigned to a joint mobilization group(n=11) or a myofascial release group(n=11). Both groups received treatment for 15 minutes four times during 2 weeks. Cervical range of motion(CROM) instrument was used to measure range of neck motion, and Algometer was used to measure tenderness. All measurements of the subjects were measured at pre-treatment and post-treatment. Results : 1. The range of neck right side-bending motion of the myofascial release group was significantly increased(P<0.05), and the range of neck extension, right side-bending, left side-bending, right rotation motion of the joint mobilization group was significantly increased(P<0.05). 2. There was no significant improvement of tenderness in both groups(p>0.05). Conclusion : These data suggest that joint mobilization is more effective against increasing the range of motion than myofascial release, but myofascial release is more beneficial to tenderness than joint mobilization although it does not have a significant difference in the tenderness because there was a little improvement.

  • PDF