• Title/Summary/Keyword: Bending Magnet

Search Result 30, Processing Time 0.023 seconds

DESIGN OF A BENDING MAGNET FOR THE KSTAR NBI SYSTEM

  • In, Sang-Ryul;Yoon, Byeong-Joo;Kim, Beom-Yeol
    • Nuclear Engineering and Technology
    • /
    • v.38 no.8
    • /
    • pp.793-802
    • /
    • 2006
  • The design concept of a bending magnet to be installed in the KSTAR NBI system is presented. It is the function of a bending magnet that removes unconverted ions from the main beam stream and produces an 8 MW, 120 keV deuterium neutral beam. In order to determine the proper size and shape of the bending magnet, a parametric study on the B-field pattern was carried out by changing the dimensions of the pole face model. In addition, the detailed trajectories of the dominant ion species produced in the beam line were calculated. The electrical and cooling parameters of the coil assembly were also estimated.

A test of the Bending Magnet on Neutral Beam Injection System (중성자 입사장치(NBI)용 휨 전자석(Bending Magnet)의 성능 시험)

  • Jun, Yong-Woo;Oh, Byung-Hoon;Chang, Doo-Hee;Jung, Ki-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.355-358
    • /
    • 2003
  • 본 연구에서는 차세대 초전도 핵융합장치(KSTAR)의 가열장치인 중성입자입사장치(NBI : Neutral Beam Injection) 시스템 중 휨 전자석(Bending magnet)의 중요한 파라메타인 전류에 따른 온도상승값과 B-field의 측정을 행하고 그 결과를 나타내었다. 휨 전자석(Bending magnet)은 중성입자입사장치(NBI) 시스템 중 중성화장치(Neutralizer) 후단에 설치되어, 미처 중성화되지 못한 이온들의 케도를 변경시켜 중성입자와 분리되도록 한 후 이온덤프에서 이들 이온들의 에너지가 흡수될 수 있도록 하는 역할을 한다. 사용전원은 15[V], 1200[A]의 가변전원을 사용하였고 전류값 변화에따른 온도상승값은 thermo couple 신호선을 이용하여 측정하였으며, B-field는 3차원 Gaussmeter를 이용하여 측정을 행하였다. 측정된 결과들은 설계시의 값과 비교분석을 행하여 오차를 줄여나가고자 하였고 향후 NBI 주 진공용기에 장착하여 중성입자입사장치의 개발 수행을 행하게 될 것이다.

  • PDF

Operation Characteristic of Filtered Vacuum Arc Source for Amorphous Diamond Coating (비정질 다이아몬드 코팅을 위한 자장여과 아크소스의 동작 특성에 관한 연구)

  • kim, Jong-Guk;Lee, Gu-Hyeon
    • 연구논문집
    • /
    • s.30
    • /
    • pp.147-157
    • /
    • 2000
  • The filtered vacuum arc source (FVAS), which is adopted by magnetic filtering methode to remove the macro-particle in vacuum arc plasma, was composed of a torus structure with bending angle of 60 degree. The radius of torus was 266 mm, the radius of plasma duct was 80 mm and the total length was 600 mm. The magnet parts were consisted of one permanent magnet, one magnetic yoke and five solenoid magnets. The plasma duct was electrically isolated from the ground so that a bias voltage could be applied. The baffles inside plasma duct were installed in order to prevent the recoil effect of macro-particles. Graphite was used as the cathode material to coat the amorphic diamond film and its diameter was 80 mm. The amorphic diamond film attracts much attention due to its excellent mechanical, optical and tribological properties suitable for wide range of applications. The effects of solenoid magnet in plasma extraction were studied by computer simulation and experiment using Taguchi's method. The source and extraction magnet affected the arc stabilization. The extraction beam current was maximized with low value of the source magnet current and high value of the filtering magnet current. Optimum deposition condition was obtained when the currents of arc discharge, source, extraction, bending, deflection and outlet magnet were 30 A, 1 A, 3 A, 5 A, and 5 A, respectively.

  • PDF

Topology Optimization of a Bias Magnetic Field for the Performance Improvement of a Magnetostrictive Sensor (마그네토스트릭션 센서 성능 향상을 위한 바이어스 자기장의 위상 최적설계)

  • Cho, Seung-Hyun;Kim, Youngkyu;Kim, Yoon-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.554-558
    • /
    • 2002
  • A magnetostrictive sensor is used to measure stress waves propagating in a ferromagnetic cylinder without physical contact. The performance of a magnetostrictive sensor is affected most significantly by the bias magnetic field applied around the measurement location. The goal of this paper is to carry out the topology optimization of the bias magnet and yoke assembly to maximize the sensor output for traveling bending waves. We will use the multi-resolution topology optimization strategy to find the assembly of the bias magnet and the yoke that is easy to realize. The effectiveness of the present design is confirmed by an actual measurement of the sensor signal with the proposed bias magnet and yoke configuration.

  • PDF

Study of photon beam quality tool at magnetic field change in bending magnet (편향전자석의 자장변화에 따른 광자선 선질평가에 관한 고찰)

  • Kim, Jeong-Ho;Yoo, Se-Jong;Park, Myeong-Cheol;Bae, Seok-Hwan;Kim, Ki-Jin
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.433-439
    • /
    • 2014
  • Beam quality is changed about magnetic field of bending magnet. Evaluation of beam quality using PDD(Percentage Depth Dose) at 10cm depth at recommendation of AAPM(America Academy of Pain Medicine). However this evaluation shows fragmentary element. Therefore this study is applied to three value, 10cm divided by 5cm depth PDD, 20cm divided by 10cm depth PDD, 30cm divided by 20cm depth PDD, at change the magnetic field. PDD is measured at magnetic field changed ${\pm}1%$, ${\pm}2%$ at 6MV(Mega Voltage), 10MV photon. The plan technique is 3 portal plan using Core-Plan at human pelvic phantom. Conventional and presented methods are compared at maximum and minimum dose. The presented method increased discernment of relieve the unequal distribution and energy area than conventional method. Henceforth, application of presented method will be considered. Development of energy measurement method and detector miniaturization will be needed about continuous study.

The analysis of bending processes in $Nb_{3}$Sn Cable-in-Conduit Conductors ($Nb_{3}$Sn 도관 케이블 도체의 굽힘변형 해석)

  • 남현일;이호진;박재학
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.259-262
    • /
    • 2002
  • Cable-in-Conduit Conductors (CICC) have been used for fabrication of nuclear fusion magnets. Bending process is included in fabrication of superconducting magnet such as termination of conductors. Because of plastic deformation by bending process, there can be a large residual stress and change of shape in bent conductors. Void volume fraction in conductors is also changed by bending process. In this study, Commercial code was used to analyze the bending process at various bending curvature radius. The calculated residual stress of conductors bent at less than about 40cm curvature radius exceeded the allowable stress.

  • PDF

Critical Current Degradation Characteristics by Temperature Difference of L$N_2$-Normal in Repetitive Bending Strain of High Temperature Superconducting Tape (고온 초전도 선재의 굽힘횟수와 온도차에 의한 임계전류저하특성)

  • 김해준;김석환;송규정;김해종;배준한;조전욱;성기철
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.274-277
    • /
    • 2003
  • Critical current(Ic) degradation of HTS tapes after bending is one of the hottest issues in HTS development and application studies. Many people are measuring Ic degradations for effect of bending radius. However even if the bending radius is larger than the breaking radius a HTS tapes can be damaged by repetitive bending, which is unavoidable in the winding processes. Therefore, We studied the Ic degradation after repetitive bending. at 77K with self-field, of Bi-2223 tapes processed by "Powder-in-Tube" technique, which was made by America Superconductor Corporation(AMSC) and superconductiing tapes that strain is imposed measured critical current by temperature difference of L$N_2$ and normal temperature. Like this, critical current could measure that degradation about 1~3% by temperature difference. These results will amount the most important basis data in power electric machine of superconductivity cable, magnet, etc that winding work is require.

  • PDF

The effects of solenoid magnet on plasma extraction in Filtered Vacuum Arc Source (FVAS) (자장여과 아크 소스에서 각 전자석이 플라즈마 인출에 미치는 영향)

  • 김종국;변응선;이구현;조영상
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.431-439
    • /
    • 2001
  • In this paper, the a-Diamond films were synthesized using filtered vacuum arc source (FVAS), FVAS was composed of a torus structure with bending angle of 60 degree. The radius of torus was 266 mm, the radius of plasma duct was 80 mm and the total length was 600 mm. The magnet parts were composed of one permanent magnet and five solenoid magnets. The plasma duct was electrically isolated from the ground so that a bias voltage could be applied. The baffles inside plasma duct were installed in order to prevent the recoil effect of macro-particles. Cathode was made of graphite with 80 mm in diameter. The effects of solenoid magnet on plasma extraction were investigated by computer simulation and experiment using Taguchi's methode. The source and extraction magnet affected the arc stabilization. The extraction beam current was maximized with low value of the source magnet current and high value of the filtering magnet current. The beam current density was 3.2 mA/$\textrm{cm}^2$ and average deposition rate was 5 $\AA$/sec when the currents of arc discharge, source, extraction, bending, deflection and outlet magnet were 30 A, 1 A, 3 A, 5 A, 5 A, and 5 A, respectively. The beam current density and the efficiency of beam transportation were increased with the positive bias voltage of the plasma duct.

  • PDF

Evaluation of mechanical properties of Bi-2223/Ag HTS tapes (Bi-2223/Ag 고온초전도 선재의 기계적 특성 평가)

  • 하홍수;이동훈;양주생;최정규;윤진국;하동우;오상수;권영길
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.351-354
    • /
    • 2002
  • In most of electrical applications using Bi-2223/Ag HTS tapes, bending and tension stresses are essentially applied to the tape. Therefore, the critical current of the Bi-2223/Ag tape is degraded by increasing the deformation stress, though brittle superconducting filaments are embedded in the reinforced Ag alloy sheath. It is needed to understand bending and tension properties of HTS tapes at room temperature and cryogen to make superconducting magnet, cable and etc. using Bi-2223/Ag HTS tapes. Actually, bending and tension stress applied to the tapes simultaneously, when winding the tapes on former for applications. In this study, the effect of mechanical deformations, bending and tension, on the critical current of Bi-2223/Ag tape was investigated.

  • PDF

A Study on the Electrical and Mechanical Properties of Conduction Cooling HTS SMES

  • Choi, Jae-Hyeong;Choi, Jin-Wook;Shin, H.S.;Kim, H.J.;Seong, K.C.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.2
    • /
    • pp.29-32
    • /
    • 2009
  • The conduction cooling HTS SMES magnet is operated in cryogenic temperature. The insulation design at cryogenic temperature is an important element that should be established to accomplish miniaturization that is a big advantage of HTS SMES. However, the behaviors of insulators for cryogenic conditions in air or vacuum are virtually unknown. Therefore, we need active research and development of insulation concerning application of the conduction cooling HTS SMES. Specially, this paper was studied about high vacuum and cryogenic temperature breakdown and flashover discharge characteristics between cryocooler and magnet-coil. The breakdown and surface flashover discharge characteristics were experimented at cryogenic temperature and vacuum. Also, we were experimented about mechanical properties of 4-point bending test. From the results, we confirmed that about research between cryocooler and magnet-coil established basic data in the insulation design.