• Title/Summary/Keyword: Bench-scale

Search Result 353, Processing Time 0.03 seconds

A Study on Microorganism Dominant Species in Bench-scale Shipboard STP Using Combined SBR and MBR Process (SBR 및 MBR 복합공정을 적용한 Bench-scale Shipboard STP에서의 미생물 우점종에 관한 연구)

  • Choi, Young-Ik;Shin, Dae-Yeol;mansoor, Sana;Kwon, Min-Ji;Jung, Jin-Hee;Jung, Byung-Gil
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.550-555
    • /
    • 2018
  • International Maritime Organization (IMO) is one of the most effective organizations in evolving international law for the protection and conservation of the marine environment. The IMO, MARPOL(Marine Pollution) 73/78 contains six Annexes that provide an overarching framework for the objectives of the international marine pollution. Annex IV was regulated by 64 th resolution in 2012 to control sea pollution from sewage. In 2014 large-scale wastewater treatment and nutrient removal device was developed with a grant from the Ministry of Oceans and Fisheries. A combined new process of Sequence Batch Reactor (SBR) and Membrane Bioreactor(MBR) was developed to overcome the pollution caused by shipboard sewage. In the present study, shipboard sewage wastewater was treated by mixing and aeration cycle in the newly developed SBR process. Furthermore, during analysis by NGS technique(Macrogen Co., Ltd.), dominant species of bacteria were found in the aeration tank of the Bench-scale wastewater treatment facility. Bacteroidetes and Gammaproteobacteria accounted for 27.1 % of the aerobicbacteria and 16.8 % of the anaerobicbacteria, respectively. Microorganisms play a vital role in shipboard wastewater treatment. A further detailed study is required to understand the precise role of the microorganisms in the wastewater treatment.

Scale-up of Recombinant Hirudin Production from Saccharomyces cerevisiae

  • Kim, Chul-Ho;K. Jagannadha Rao;Youn, Duk-Joong;Rhee, Sang-Ki
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.5
    • /
    • pp.303-305
    • /
    • 2003
  • Scale-up of hirudin production from Saccharomyces cerevisiae from bench-scale to pilot-scale was carried out based on constant volumetric oxygen transfer coefficient (K$\sub$L/a). Fed-batch mode of cultivation using step-wise feeding strategy of galactose was employed for the production of hirudin in a 30-L and a 300-L pilot-scale fermentor. The final hirudin concentrations were achieved 390 mg/L and 286.1 mg/L, and the volumetric productivities were 80.4% and 90.7% with the 30-L and 300-L fermentors, respectively, compared to the productivity of the 5-L bench-scale fermentor.

Control Logic Optimization for the Bench Scale Coal Gasification System (Bench급 석탄가스화 시스템 제어로직의 최적화)

  • 김원배;조성수;유희종;윤용승
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2000.11a
    • /
    • pp.33-38
    • /
    • 2000
  • IGCC(Integrated Gasification Combined Cycle) BSU(Bench Scale Unit) 석탄 가스화공정은 정상상태 조업시 약 145$0^{\circ}C$, 25기압의 고온 및 고압의 조건하에서 운전되기 때문에 설정된 운전조건을 안정하게 유지하기 위해서 이러한 조건에 상응하는 안정된 제어로직의 구성은 매우 중요한 요소이다.(중략)

  • PDF

Gasification Characteristics in a Bench Scale Coal Gasifier (Bench Scale급 건식 석탄가스화기에서의 가스화 특성)

  • 유영돈;임동렬;이한구;정석우;윤용승
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.10b
    • /
    • pp.91-97
    • /
    • 1996
  • Bench Scale급 가스화기를 이용하여 중국 대동탄에 대하여 O2/coal 비, 가스화기 운전 압력에 따른 가스화 특성을 조사하였다. 가스화기를 가압하는 방법으로 메탄과 산소의 버너를 이용하여 운전 압력까지 단시간 내에 가압하는 방법을 정립하였다. 가스화기 압력은 상압으로부터 10기압까지 실험을 실시하였으며, 10기압, 반응온도 1350-140$0^{\circ}C$, O2/coal 비(as-fed 기준) 0.9의 운전조건에서 탄소전환률 90%이상, 냉가스효율 60%, 그리고 heating value 1800 Kcal/N㎥ 정도의 생성가스 특성을 얻을 수 있었다.

Study of Bench scale Chemical Absorption Process for $CO_2$ Separation ($CO_2$ 분리회수를 위한 Bench 규모의 화학흡수분리공정 운전특성 연구)

  • 남성찬;박성열;이종섭;민병무;임정수
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.697-702
    • /
    • 2003
  • 실험실규모(0.5Nm$^3$/hr)의 이산화탄소 연속흡수분리장치의 실험결과를 바탕으로 Bench규모(5Nm$^3$/hr)의 이산화탄소 연속흡수분리장치 설계하였다. MEA용 이산화탄소 연속흡수분리 장치를 4개의 흡수탑과 2개의 탈거탑을 연결하여 각각 독립적으로 실험할 수 있도록 장치를 제작하고 실험변수에 따른 이산화탄소의 흡수분리효율을 측정하였다. 설치된 실험장치에 대하여 주어진 실험범위에서 실험한 결과, 이산화탄소 제거율이 45~100%에 존재함을 확인하였다. 실험결과와 설계기준을 고려한 scale-up factor는 설계결과와 실험결과를 종합하였을 때, 각각 1.00~1.85인 것으로 산출되었다.

  • PDF

The Evaluation of Fire Safety Performance on Interior Finish Materials (Gypsum Board, Plywood) (건물내장재(석고보드, 합판)의 화재성능평가)

  • 김충환;김종훈;김운형;하동명;이수경
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.55-62
    • /
    • 2001
  • The fire performance evaluation methods in Korea and overseas for interior finish materials were analysed and tested with gypsum board and Plywood by using room corner test not adopted by domestic code until now. The results of gypsum board (thickness:8 mm) and Plywood (thickness:4 mm) applying NFPA 265 and ISO 9705 test respectively are satisfied the assessment criteria. To assess a actual fire performance and classify fire hazard levels for interior finish materials, room-corner test and flame spread models should be adopted in building code and fire code to overcome limitations of current bench-scale test method.

  • PDF

Volume Reduction Ratio and Decontamination Factor of the Bench Scale Radwaste Incineration Process (실험용 방사성 폐기물 소각로의 감용비와 제염계수)

  • Seo, Yong-Chil;Yang, Hee-Chul;Kim, Joon-Hyung;Park, Hun-Hwee
    • Nuclear Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.321-331
    • /
    • 1989
  • A bench scale incineration process for the burnable radwaste has been constructed and operated at KAERI as a self-surpported development of incineration technology. The purposes of operating the process are to get experience in incineration, to analyze the characteristics of combustion and to test the performance of off-gas treatment units. Simulated paper and polyethylene wastes were incinerated. Volume reduction ratio and decontamination factor of the process have been determined to observe the economical efficiency and operational capability of the process. A methodology to estimate the acceptance limit of specific activity to an incineration facility by using a decontamination factor and to calculate the volume reduction ratio of the facility is introduced. The acceptance criteria for different radionuclides in the combustible waste at the bench scale incineration process are suggested using this methodology.

  • PDF

Effect of Temperature on Treatment of Nitrogen and Phosphorus of Pig Wastewater in Bench Scale Reactor (실험실 수준의 반응조 온도가 양돈폐수중 질소, 인의 처리에 미치는 영향)

  • 박석환
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.1
    • /
    • pp.86-92
    • /
    • 1995
  • This study was performed to evaluate the effect of temperature on operating parameters for reactor in pig wastewater treatment using sequencing batch reactor method which is one of the biological treatment methods. Study was accomplished by experimental apparatus of bench scale, and the degradation rate coefficient and temperature correction factor were derived. The followings are the conclusions that were derived from this study. 1. In the characteristics of pig wastewater, concentrations of TKN and T-P were very high as 590 mg/l and 40 mg/l, respectively. 2. Removal efficiency of BOD and $COD_{Mn}$ as organic compound indicators were the highest mark as 97% at 25$\circ$C. 3. When temperature was incresed from 10$\circ$C to 25$\circ$C, removal efficiencies of TKN and T-P were proportionally increased. Especially, the former was greatly effected by temperature of reactor. 4. In experiment of bench scale, the degradation rate coefficients were increased as temperature increased, but decreased at the temperature range of 25~35$\circ$C. Temperature adjustment coefficients for $COD_{Mn}$, BOD, TKN and T-P were 1.1460, 1.1356, 1.1140 and 1.0565, respectively.

  • PDF

Biological Removal of Explosive 2,4,6-Trinitrotoluene by Stenotrophomonas sp. OK-5 in Bench-scale Bioreactors

  • Oh, Kye-Heon;Lee, Myung-Seok;Chang, Hyo-Won;Kahng, Hyung-Yeel;So, Jae-Seong
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.7 no.2
    • /
    • pp.105-111
    • /
    • 2002
  • The biological removal of 2,4,6-trinitrotoluene (TNT) was studied in a bench-scale bioreactor using a bacterial culture of strain OK-5 originally Isolated from soil samples contaminated with TNT. The TNT was completely removed within 4 days of incubation in a 2.5 L bench-scale bioreactor containing a newly developed medium. The TNT was catabolized in the presence of different supplemented carbons. Only minimal growth was observed in the killed controls and cultures that only received TNT during the incubation period. This catabolism was affected by the concentration ratio of the substrate to the biomass. The addition of various nitrogen sources produced a delayed effect for the TNT degradation. Tween 80 enhanced the degradation of TNT under these conditions. Two metabolic intermediates were detected and identified as 2-amino-4, 6-dinitrotoluene and 4-amino-2, 6-dinitrotoluene based on HPLC and GC-MS analyses, respectively. Strain OK-5 was characterized using the BIOLOG system and fatty acid profile produced by a microbial identification system equipped with a Hewlett Packard HP 5890 II gas chromatograph. As such, the bacterium was identified as a Stenotrophomonas species and designated as Stenotrophomonas sp. OK-5.

Development of Bench Tester for Designing the Passive Anti-Rolling Tanks (수동형 감요수조 설계를 위한 벤치테스터 개발)

  • Lew, Jae-Moon;Kim, Hyochul
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.6
    • /
    • pp.452-459
    • /
    • 2015
  • It is important to use bench test results in the design process of anti-rolling tanks. Traditional bench tester is usually designed to perform only roll motions about a fixed axis and relatively small so that the viscous effects may not be neglected. Novel bench tester which could adjust the motion center to realize the coupled motion of sway and roll has been devised and manufactured therefore, large scaled bench tester could be utilized for designing the passive anti-rolling tanks. The time history of the reference signal from the rotation sensor of the bench tester have been recorded and processed to determine the phase angle to derive the Response Amplitude Operator(RAO) of the stabilized ship. The breadth of ART tank model should be large up to 2 m to diminish viscous scale effect and the vertical position of the tank can be varied with the ship's center of motion. The periods and the amplitude of roll motion can be varied from 1.5 sec to 5 sec and up to ±20°, respectively. The components of the tester was expressed in three dimensional digital mockup (DMU) and assembled together in the CAD space. The final configuration of the bench tester has been determined by confirming the smooth operation of the moving parts without interference through the animation in CAD space. New analytic logic are introduced for the determination of hydrodynamic moment and phase difference due to fluid motion in ART and verified through the test. The developed bench tester is believed to be effective and accurate for the verification of stabilization effect of ART taking into the consideration of the sway effect in the design stage.