Construction of Super-block Unit Curtain Wall for High-rise Buildings Utilizing a Specialized Installing Equipment (전용 양중틀을 활용한 초고층 건물의 슈퍼블럭 유닛 커튼월 시공)

  • Chung, Sam-Yong;Lee, Sang-Heon;Ohk, Young-Mu
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2004.11a
    • /
    • pp.174-181
    • /
    • 2004
  • We will introduce a method of construction of super-block curtain wall applied to Tower Palace III which is the highest high-rise complex building in Korea. Up-up method is utilized on Tower Palace III to shorten the term of works and it is that the curtain walls for the belt wall part are installed after the rests. The belt wall structure increases the horizontal structural stiffness of the building. The method of construction of super-block curtain wall is developed and used to raise and install the curtain wails of the belt wall floor. It is that the large block of curtain walls corresponding to three stories is fabricated on the ground in advance and the block is installed at a time by a tower crane. Specialized installing equipment :,s newly developed and applied to install the super-block. curtain wail. The curtain wall of the upper floor of the belt wall part is installed after the super-block. The installing equipment for this floor is developed utilizing a mini excavator and vacuum suctions. The application of this method had made it possible to omit the setting up the scaffold and financial profits such as the shortening of the terms of works was realized. The safety of works was secured and the productivity was also improved.

  • PDF

Seismic Behaviour of Eco-BELT System and Seismic Effectiveness of T-shaped Deadman Considering Soil-Structure Interface Based on Dynamic Numerical Analysis (흙-구조물 접촉면을 고려한 친환경 옹벽 구조물의 지진시 거동 및 T형 후방지지물의 보강효과에 대한 동해석 분석연구)

  • Kwak, Chang-Won;Park, Inn-Joon
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.8
    • /
    • pp.37-49
    • /
    • 2021
  • A retaining wall system is widely constructed civil structure to maximize the effectiveness of practical use of the land. Recently, the technology which is more eco-friendly and owns seismic stability of the retaining wall system becomes important. In this study, an Eco-BELT system using natural rocks as the front wall is introduced and the seismic characteristics of the Eco-BELT system are analyzed based on 2 and 3 dimensional numerical analysis. The soil-structure interface comprises between backfill soil and natural rocks are considered. The relative density is mainly considered to influence the seismic behavior of Eco-BELT system, and T-shaped deadman is also considered to judge the increase of seismic stability. As a result, lateral displacement of the wall decreases 29.5% in maximum under 90% of relative density and decreases 21.2 to 21.9% with T-shaped deadman, therefore, the seismic effectiveness of T-shaped deadman and increasing relative density of backfill are verified by numerical analysis.

A Study of Costumes Appearing in Afrasiab Mural Painting (아프라시압 벽화에 나타난 복식연구)

  • Kim, Yong-Mun
    • Journal of the Korean Society of Costume
    • /
    • v.60 no.7
    • /
    • pp.117-130
    • /
    • 2010
  • The four walls of mural paintings in Afrasiab, Samarkand, have discovered: the indian-concept east wall, the west with the paintings of envoys from a number of countries bringing in King's letters or gifts, the south describing traditional ceremony celebrating the new year, the north with a picture of a Chinese princess on board beside hunting scenes. Overall, Sogdians in Afrasiab mural paintings of 7th century had following costume codes: a very short haircut or the Turkic queue, a rather-narrow-sleeved caftan with round-neck, a belt and boots. The west wall showed various costume style of a set of envoys from countries. First, a Turkic envoy had 3-6 rows of long plaits, wearing a caftan with two lapels and a belt - interestingly, Sogdian and Turkic nobles didn't wear pochettes. Second, a Chaganiyan had a hairband on his short hair, and his colorful round-neck caftan is decorated with animal-patterned medallions and a golden belt. Third, a Chach wore a jewelled hairband, putting gaiters on his pants. Forth, a Chinese was in putou with a round-neck caftan, and with a belt and sword around his waist. Lastly, also appeared a Koguryo envoy in white putou with a double-bird-feathered crown on top, wearing a long-sleeved yellow v-neck top, a belt, narrow-cuffed pants and boots. Identical to the Sogdian statues excavated in various regions of China are the appearance of big eyes and nose -similar to the warrior stone in Korea- a hairband, and a pochette down from the waist line. During this period, white and red were considered as prevailing colors for clothing: red and yellow among Turks. The costumes of characters in Afrasiab mural paintings were preferably made with the animal-patterned, sophiscated samite Zandanachi of Sogdiana.

An Application of High Strength Concrete with 800kg/c $m^2$ to High-Rise Building (초고층 빌딩 적용을 위한 설계강도 800kg/c $m^2$ 고강도 콘크리트의 개발)

  • 김규동;이승훈;김명식;손유신;김한준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.55-60
    • /
    • 2002
  • The columns and The belt wall of Tower Palace III were desined as 800kg/c $m^2$ ultra-high strength concrete. The concrete should meet or exceed the requirements of slump of 23cm, $\sigma$$_{18H}$ of 100kg/c $m^2$, $\sigma$$_{91th}$ of, 800kg/c $m^2$. The concrete mixings with 4 different domestic Silica fumes were investigated. Laboratory tests, the pilot productions of batcher plant and the full-scale mock up tests were performed. As results of site application, all test results are satisfied with the requirements of columns and belt wall.l.

  • PDF

Construction Technology of High Strength Concrete Designed 800kg/$cm^2$ for High-Rise Building (초고층 건물용 800kg/$cm^2$의 초고강도콘크리트 시공기술)

  • 김규동;이승훈;김규용;손유신;김한준
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.49.2-53
    • /
    • 2003
  • This paper reports the application of high strength concrete designed as 800kg/$cm^2$ on the columns and belt wall of Tower Palace III. The concrete should meet or exceed the requirements of slump of 23cm, ${\sigma}$18H of 100kg/$cm^2$, ${\sigma}$91th of 800kg/$cm^2$. The concrete mixings with 4 different domestic Silica fumes were investigated. Laboratory tests, the pilot productions of batcher plant and the full-scale mock up tests were performed As results of site application, all test results are satisfied with the requirements of columns and belt wall.

  • PDF

Optimization of Seat belt Load Limiter for Crashworthiness (안전벨트 충돌하중특성 최적화)

  • Seo, bo pil;Choi, sung chul;Kim, beom jung;Han, sung jun
    • Journal of Auto-vehicle Safety Association
    • /
    • v.3 no.2
    • /
    • pp.5-10
    • /
    • 2011
  • Under the full frontal crash event, seatbelt system is the most typical and primary restraint device that prevents the second impact between an occupant and vehicle interior parts by limiting the forward motion of an occupant in the vehicle occupant packaging space. Today's restraint systems typically include the three-point seat belt with the pretensioner and the load limiter. A pretensioner preemptively tightens the seat belts removing any slack between a passenger and belt webbing which leads to early restraint of a passenger. After that a load limiter controls level of belt load by releasing the belt webbing to reduce occupant injurys. In this study, load characteristics of load limiters are optimized by the computer simulation with a MADYMO model for a frontal impact against the rigid wall at 56kph and then we suggest performance requirements. We derived optimum load characteristic from the results using four vehicle simulation models represented by the vehicle. Based on the results, we suggest the performance from the results of the second optimization using the simulation considering the design and the standardization. Finally, the performance requirements is verified by the sled tests including the load limiter device for the full vehicle condition.

The Effects of Manual Therapy using Pelvic Compression Belt on Hip Abductor Strength and Balance Ability in Total Knee Replacement Patients. (골반압박벨트를 착용한 상태에서의 도수치료가 슬관절 전치환술 환자의 고관절 외전근과 균형에 미치는 영향)

  • Shin, Young-il;Kim, Tae-won;Jeon, Jae-guk
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.24 no.1
    • /
    • pp.77-83
    • /
    • 2018
  • Background: The purpose of this study is to investigate that effect of manual therapy using pelvic compression belt on hip abductor strength and balance ability in total knee replacement (TKR) patients. Methods: The subjects consisted of twenty two post-TKR patients. Participants were randomly assigned to a pelvic belt group (n=11) and a placebo group (n=11). All participants underwent manual therapy including range of motion exercise, soft tissue mobilization around knee joint, strengthening exercise (Quad set, SLR, sidelying hip abduction, standing hamstring curls, sitting knee extension, step-up, wall slide to $45^{\circ}$ knee flexion). Manual therapy was executed five times a week for 2 weeks. Outcome measures included hip abductor strength by using Biodex system 4 pro, anterior to posterior balance, medial to lateral balance, total balance by using Biodex balance system SD. Results: After the completion of the manual therapy, hip abductor strength was showed statistically significant improvements in pelvic belt group (p<.05). Anterior to posterior balance, medial to lateral balance, total balance were showed statistically significant improvements in pelvic belt group and placebo group (p<.05). There was a statistically significant difference between the two groups in hip abductor strength and there was no statistically significant difference in balance. Conclusions: This results suggest that manual therapy using pelvic compression belt has could be used for selective muscle activation of the hip abductor muscle and has useful in hip abductor strength and balance ability in TKR patients.

Study on a seismic slit shear wall with cyclic experiment and macro-model analysis

  • Jiang, Huanjun;Lu, Xilin;Kwan, A.K.H.;Cheung, Y.K.
    • Structural Engineering and Mechanics
    • /
    • v.16 no.4
    • /
    • pp.371-390
    • /
    • 2003
  • The concept of the seismic slit shear wall was proposed in the early 1990's. A series of experimental and theoretic studies on the wall with reinforced concrete short connecting beams cast in the slit were carried out. In this paper another type of slit shear wall is studied. It is one with vertical slit purposely cast within the wall, and the rubber belt penetrated by a part of web shear reinforcement as seismic energy-dissipation device is filled in the slit. Firstly, an experiment under cyclic loading was carried out on two shear wall models, one slit and the other solid. The failure mechanism and energy-dissipation capacity are compared between the two different models, which testifies the seismic performance of the slit wall improved significantly. Secondly, for engineering practice purpose, a macroscopic analytical model is developed to predict the nonlinear behavior of the slit shear wall under cyclic loading. The mechanical properties of each constituent elements of this model are based on the actual behavior of the materials. Furthermore, the effects of both the axial force and bending moment on the shear behavior are taken into account with the aid of the modified compression-field theory. The numerical results are verified to be in close agreement with the experimental measurements.

Efficient Dynamic Analysis of High-rise Buildings Having Belt Walls Connected by a Sky-Bridge (스카이브릿지로 연결된 벨트월이 있는 고층건물의 효율적인 동적해석)

  • Lee, Dong-Guen;Kim, Hyun-Su;Yang, Ah-Ram;Ko, Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.3
    • /
    • pp.231-242
    • /
    • 2009
  • In the design of a sky-bridge, repetitive boundary nonlinear time history analyses are required to accurately predict dynamic behaviors of the connected buildings because the connection systems of a sky-bridge usually have high nonlinearity. If a conventional finite element model for entire high-rise buildings is used for repetitive boundary nonlinear time history analyses, computational efforts could be significant. In this study, an equivalent cantilever model considering the belt-wall effect has been proposed for an efficient dynamic analysis and a performance evaluation of vibration control of high-rise buildings connected by a sky-bridge. To verify the accuracy and efficiency of the proposed equivalent model, boundary nonlinear time history analyses of 49- and 42-story example buildings connected by a sky-bridge have been performed for wind excitation. Based on the analytical results, it has been verified that the proposed equivalent model can provide accurate dynamic responses of building structures connected by a sky-bridge with significantly reduced computational efforts.

Traumatic Abdominal Wall Hernia (TAWH): Repair by using a Prolen Mesh (복부손상으로 생긴 탈장에 Prolene Mesh를 이용한 수술 1례)

  • Park, Seung Yeon;Chung, Min
    • Journal of Trauma and Injury
    • /
    • v.22 no.1
    • /
    • pp.119-122
    • /
    • 2009
  • Traumatic abdominal wall hernia after blunt abdominal trauma is rare. The prevalence of traumatic abdominal wall hernia in published series is approximately 1%. Recently, by the use of computed tomography has increased the number of occult traumatic abdominal wall hernias (TAWH). A 47-year-old woman presented to the emergency room soon after a traffic accident. She was fully conscious and complained of diffuse, dull, abdominal pain. She had a seat belt on at the time of the accident. Initial computed tomography showed that the lower left abdominal wall had a defect and that a part of the small bowel had herniated through the defect. During the operation, we made an incision at the defect site and confirmed the defect. The defect size was about $15{\times}5cm$. The muscle layers were repaired in layers with absorbable sutures. Prolen mesh was layed down and fixed on the site of the repaired muscle defect. After 6 months, hernia had not recurred, and no weakness of the repaired abdominal wall layers was identified. The patient's postoperative body functions were normal.