• Title/Summary/Keyword: Below the knee

Search Result 126, Processing Time 0.022 seconds

Lower limb ischemia after bee sting

  • Ryu, Hee Yun;Yoo, Min Seok;Park, Ji Young;Choi, Jae Woong;Ryu, Sung Kee;Kim, Seunghwan;Lee, Se Jin;Kim, Young Bin
    • Journal of Yeungnam Medical Science
    • /
    • v.33 no.2
    • /
    • pp.134-137
    • /
    • 2016
  • Bee sting causes mild symptoms such as urticaria and localized pain, and severe symptoms including anaphylaxis, cardiovascular collapse, and death. We reported on a patient with arterial thrombotic occlusion and severe ischemia in the lower limb after multiple bee stings. The patient was stung 5 times and complained of pallor, pain, and coldness in the left toe, and did not have dorsalis pedis pulsation. Computed tomography angiography showed multiple thrombotic occlusion of the anterior and posterial tibial artery below the knee. Local thrombolytic therapy using urokinase was administered and the occluded arteries were successfully recanalized.

The Biomechanical Comparison of Running Shoes According to the Difference of Insole (인솔 차이에 따른 런닝화의 운동역학적 비교)

  • Jin, Young-Wan;Shin, Sung-Hwon
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.2
    • /
    • pp.51-59
    • /
    • 2007
  • These studies show that I applied to functional insole (a specific A company) for minimizing shocks and sprain people's ankle arising from running. How to an effect on human body which studied a kinematics and kinetics from 10 college students during experiments. This study imposes several conditions by barefoot, normal running shoes and put functional insole shoes ran under average $2.0{\pm}0.24\;m$/sec by motion analysis and ground reaction force that used to specific A company. First of all, motion analysis was caused by achilles tendon angle, angle of the lower leg, angle of the knee, initial sole angle and barefoot angle. The result of comparative analysis can be summarized as below. Motion analysis showed that statically approximates other results from achilles tendon angle (p<.01), initial ankle angle(p<.05), initial sole angle(p<.001) and barefoot angle(p<.001). Ground reaction force also showed that statically approximates other results from impact peak timing (p<.001), Maximum loading rate(p<.001), Maximum loading rate timing (p<.001) and impulse of first 20 percent (p<.001). Above experiment values known that there was statically difference between Motion analysis and Ground reaction force under absorbing of the functional insole shoes which was not have an effect on our body for kinetics and kinematics.

The Biomecanical Analysis of Taekwondo Footwear (태권도화의 운동역학적 분석)

  • Jin, Young-Wan;Kawk, Yi-Sub
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.105-114
    • /
    • 2007
  • The purpose of this study was to compare the biomechanical difference of barefoot and two types taekwondo footwear. which will provide scientific data to coaches and players, to further prevent injuries and to improve each players skills. How to an effect on human body which studied a kinematics and kinetics from 8 college students during experiments. This study imposes several conditions by barefoot and two types of taekwondo footwear ran under average $2.56{\pm}0.21\;m$/sec by motion analysis, ground reaction force and electromyography that used to specific A company. First of all, motion analysis was caused by achilles tendon angle, angle of the lower leg, angle of the knee. The result of comparative analysis can be summarized as below. Motion analysis showed that statically approximates other results from achilles tendon angle (p<.01), initial ankle angle(p<.05), initial sole angle(p<.001) and barefoot angle(p<.001). Ground reaction force also showed that statically approximates other results from impact peak timing (p.001), Maximum loading rate(p<.001), Maximum loading rate timing (p<.001) and impulse of first 20 percent (p<.001). showed that averagely was distinguished from other factors, and did not show about that.

Chondrosarcoma of the Calcaneus in 13 year old Aged Patient - A Case Report - (13세 환자의 종골에 발생한 연골육종 - 증례 보고 -)

  • Hong, Ki-Do;Ha, Sung-Sik;Park, Young-Keun;Lee, Hyo-Jin;Cha, Hyun-Jong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.7 no.2
    • /
    • pp.59-63
    • /
    • 2001
  • Chondosarcoma of the calcaneus in young child is extremely rare. A thirteen-year old male patient has suffered from right heel pain for several months before. Dominant gross feature was hard mass and swelling on one entire right heel, and increased density and calcification on entire calcaneus with cortical destruction, and calcific densities on soft tissues around calcaneus were seen on roentgenogram of right ankle. It was diagnosed to be chondrosarcoma by bone biopsy. It was treated by below knee amputation and chemotherapy, and no recur and distant metastsis during 12 months after operation.

  • PDF

A Case of Henoch-Schönlein Purpura Associated with Mycoplasma Pneumoniae Pneumonia (Mycoplasma pneumoniae 폐렴에 동반된 Henoch-Schönlein purpura 1례)

  • Kim, Jong Jin;Cha, Jae Kook;Lee, Kon Hee;Yoon, Hye Sun
    • Pediatric Infection and Vaccine
    • /
    • v.4 no.2
    • /
    • pp.271-275
    • /
    • 1997
  • We experienced a case of Henoch-Sch$\ddot{o}$nlein purpura associated with Mycoplasma pneumoniae pneumonia in a 28 month old male who suffered from cough, abdominal pain and both leg swelling and pain. Physical examination showed varying sized purpura, characteristic of Henoch-Sch$\ddot{o}$nlein purpura, below both knee. Laboratory test revealed Mycoplasma pneumoniae antibody titer >1:2,560 and cold agglutinins titer 1:64. Chest X-ray showed peribronchial blurring in both lung fields. The patient was treated with midecamycin and prednisolone for 7 days and responded to the treatment well. The authors report a case of Henoch-Sch$\ddot{o}$nlein purpura with Mycoplasma pneumoniae pneumonia with brief review of related literatures.

  • PDF

Effect of the Shape and Attached Position of Fabric Sensors on the Sensing Performance of Limb-motion Sensing Clothes (직물 센서의 모양과 부착 위치가 사지 동작 센싱 의류의 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Yang, Jin-Hee;Jeon, Dong-Jin;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.20 no.3
    • /
    • pp.141-150
    • /
    • 2017
  • The purpose of this study was to analyze the effect of the shape and attached position of E-textile-based stretchable sensors on motion-sensing performance and to investigate the requirements for the optimal structure of clothes for sensing limb motions. An experimental garment was prepared with different sensor shapes, and attachment positions. A child subject, wearing the experimental garment, performed arm and leg bending and extension motions at $60^{\circ}$, $90^{\circ}$ and $120^{\circ}$ motion angles, at a rate of 60 deg/sec. The changes in voltage triggered by the stretching and contracting of the fabric-sensor were measured, and an acceleration sensor was utilized to verify that the experimental motions were correctly performed. Dummy arms and legs of a child were manufactured to perform an identical test, in order to compare the dummy results with the actual human body experiment results. The analysis showed that the reproducibility and reliability of the rectangular sensor, showing uniform and stable were higher than those of the boat-shaped sensor, in both the dummy and the human body experiments. The attachment position of the sensor was more reproducible and reliable when placed on 4 cm below the elbow and knee joints in the dummy test, when placed in the joints of the elbow and knee, in children experiment. The appropriate shapes and attached positions of the sensor for sensing the motions were analyzed, and the results proved that motion-sensing of the human body is possible by utilizing flexible fabric-sensors integrated into clothes.

A Numerical Study on the Response of the Tibial Component in Total Knee Arthroplasty to Longitudinal Impact (인공무릎관절 전치환술에 있어 축방향 충격에 의한 Tibial Component의 응답 특성 분석 연구)

  • 조용균;조철형;최재봉;이태수;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.503-511
    • /
    • 1998
  • In this study, the stress distribution for different tibial components was observed In order to Investigate the load transfer and potential failure mechanism of the tibial components subjected to dynamic impact loading and also to evacuate the effect of bone-implant bonding conditions on the implant system. The 3-dimensional finite element models included an intact tibia, cemented metal-backed tibial component, uncemented metal-blocked tibial component, cemented all-polyethylene tibial component, and metal-backed component with a debonded bone/stem interface. The results showed that the cemented metal-hocked component Induced slightly higher peak stress at stem tip than the uncemented component. The peak stress of the all-polyethylene tibia1 component at stem trip showed about half thats of metal-backed tibial components. The all-polyethylene component showed a similar dynamic response to intact tibia. In case of debonded bone/stem interface, the peak stress below the metal tray was three times Higher than that of the fully bonded interface and unstable stress distribution at the stem tip was observed with time, which causes another adverse bone apposition and implant loosening. Thus, the all-polyethylene tibial component bonded fully to the surrounding bone might be most desirable system under an impact loading.

  • PDF

Free Muscle Transplantation of the Chronic Lower Extremity Osteomyelitis (만성 하지 골수염에 시행한 유리 근 이식술)

  • Lee, Jun-Mo;Huh, Dal-Young
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.2
    • /
    • pp.176-183
    • /
    • 1999
  • Chronic osteomyelitis have been treated with wound dressing and antibiotics therapy often results in healing but foul odor pus discharges from the fibrotic soft tissues reactivates and requires appropriate control of the infection. Debridement of the wound, curettage and sequestrectomy, bone graft and immediate free flap transplantation is the curative protocol for the chronic osteomyelitis in the lower extremity. Authors have treated 7 cases of chronic osteomyelitis in the lower extremity with microsurgical free tissue transplantation at Department of Orthopedic Surgery, Chonbuk National University Hospital from December 1993 through February 1998. The results are as follows. 1. The chronic osteomyelitis occurred in tibial shaft in 4 cases, in calcaneus 2 cases and in femur 1 case. 2. Duration of the chronic osteomyelitis was at average 31.6 years. 3. Squamous cell carcinoma in the surrounding fibrotic tissue was biopsied in 1 case. 4. 4 cases had no trauma and occurred through hematogenous infection and 3 cases had fracture trauma. 5. Wound debridement and immediate free muscle transplantation had done in 5 cases and wound debridement, sequestrectomy and immediate free muscle transplantation in 2 cases. 6. Rectus abdominis muscle transplantation had peformed in 4 cases(57.1%), latissimus dorsi mucle 1 case(14.3%), latissimus dorsi myocutaneous 1 case(14.3%) and gracilis 1 case (14.3%). 6 cases of 7 were success(85.7%). 7. 1 case of failed latissimus dorsi musculocutaneous flap in thigh had done above knee amputation and 1 case of chronic posttraumatic osteoarthritis of the ankle joint had done below knee amputation at other hospital.

  • PDF

Assessment of Isokinetic Muscle Function in Elite Canadian College Paddlers (대학 엘리트 카나디언 선수들의 어깨·허리·무릎 관절의 등속성 근기능 평가 및 진단)

  • Shin, Kwang-Taek;An, Chang-Gyu;Sohn, Jee-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.229-238
    • /
    • 2013
  • The aim of this study is to evaluate university canadian paddlers' iso-kinetic muscle function and provide training advices. Eight university paddlers with a 8.5 years career participated in this study. Inbody 720, biodex system III, biodex stabilizer system and THP 2 are used to investigate body component, muscle function(peak torque, average power and work fatigue), agility and dynamic balance. Iso-kinetic muscle function around shoulder, thorax and knee are measured. And then bilateral and unilateral muscle imbalance are calculated at each joint. Results of this study are as follows; University canadian paddlers' BMI average is 24.90 $kg/m^2$ and percent body fat is 12.23%. Reaction time average was 324 msec and balance score at each leg are below 2.0. A3, A4, A5, A6, A8 are needed to train shoulder muscle strength and power. A1, A2, A7, A8 are needed to strengthen shoulder muscle endurance. A2, A5, A8 are needed to train thorax muscle strength and power. A1, A8 are needed to strengthen thorax muscle endurance. Most of paddlers' reciprocal muscle balance ratio on thorax and knee are out of normal range. A2, A3, A4, A8 are needed to train abdominal strength and A3, A5, A6, A7, A8 are needed to train hamstring strength.

The Kinematic Analysis of the Pitching motion for the Straight and Curve ball (직구와 커브 투구동작의 운동학적 비교 분석)

  • Lee, Young-Jun;Kim, Jung-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.109-130
    • /
    • 2002
  • The purpose of this paper was to make a comparative analysis for the difference of the various kinematic variation which is occurred in the each situation when pitchers throw a straight and a curve ball. Four pitchers, who are two national team players and two high level pitchers, were selected among the right over hand pitchers of D university in the Busan for this paper. The data were analyzed by using 3D equipment. The results of the analysis which was about the elapsed time of the pitching, the movement of the body center-point, the highest height of the left knee, stride length, knee joint angle, shoulder joint angle, elbow joint angle and wrist joint angle in the each section(ST, LKU, HBP, LCF, MCP, BRP) were as follows : 1. Pitching time in the each section and step in the pitching for straight and curve ball was similar. The total elapsed time of the straight and curve ball was 1.78${\pm}$0.07sec and 1.77${\pm}$0.11sec in the order. 2. The position change of the body center to the Z(above below) direction did not show significant difference in the each situation of the section and step between pitching for the straight and curve ball. 3. Height of the left knee did not show significant difference as 125.38${\pm}$11.85cm and 124.95${\pm}$11.63m in the each pitching motion for straight and curve ball. The rate(%H) between height and stride length showed 68.42${\pm}$5.53(%H), 68.40${\pm}$5.45(%H) in the each pitching motion. 4. Pitching for curve ball showed longer stride length than pitching for straight ball that as the stride length was 140.35${\pm}$4.96cm and 144.8${\pm}$1.69cm. The rate(%H) between height and stride length showed 76.9${\pm}$3.77(%H), 79.39${\pm}$2.23(%H) in the each pitching motion. 5. Left knee joint angle did not show significant difference in the ST, LKU and HBP section in the each pitching motion. However, it was shown that knee joint angle was flexed much more in the LFC, MCP and BRP section in the pitching for curve ball. 6. Right shoulder joint angle did not show significant difference in the ST, LKU and HSP section. However, when pitches threw a curve ball in the LKU section. In the LFC section, the right shoulder joint angle was extended much more in the pitching for curve ball, and the angle was extended much in the MCP and BRP section in the pitching for curve ball than straight ball. 7. Right elbow joint angle did not show significant difference in the ST, LKU and HRP section in the two pitching motion. The angle had more flexion in the LFC and MCP section in the pitching for curve ball than the pitching for straight ball. The angle in the each pitching motion for straight ball and curve ball were extended by a narrow margin in the BRP section. 8. Right wrist joint angle was extended much more in the LFC and MCP section in the pitching for curve ball. In the BRP section, the angle was extended much more in the pitching for straight ball than curve ball.