• Title/Summary/Keyword: Bearing Bar

Search Result 134, Processing Time 0.026 seconds

A Experimental Study on the Bearing Strength and Stiffness of Concrete Under Dowel Bars (장부 철근하부의 지압강도 및 지압강성에 관한 연구)

  • 김규선;최기봉;이리형
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.3
    • /
    • pp.215-220
    • /
    • 1994
  • Results of an experimental investigation on the bearing strength and stiffness of concrete under dowel bars are summarized. The effects of concrete strength bar diameter, and location of the bar on concrete were studied. Based on test results, empirical equations are proposed to predict the, concrete bearing strength and stiffness under reinforcing bars. Cornparisions of analytical arid experimental results are presented.

Ore Mineralization of The Copper-bearing Hanae Hydrothermal Vein Deposit (하내 함 동 열수 맥상광상의 광화작용)

  • Choi, Sang-Hoon;Lee, Sunjin;Jun, Youngshik
    • Economic and Environmental Geology
    • /
    • v.50 no.6
    • /
    • pp.435-443
    • /
    • 2017
  • The Hanae deposit is located within the Cretaceous Gyeongsang Basin. The Cu-bearing hydrothermal quartz vein formed by narrow open-space filling along fracture in the sedimentary rocks as Jindong Formation. The Hanae Cu-bearing hydrothermal deposit shows a paragenetic sequence of pyrrhotite-pyrite $\rightarrow$ pyrite-chalcopyrite-sphalerite(${\pm}$Bi-bearing tellurides) $\rightarrow$ Ag-bearing telluride mineralization $\rightarrow$ secondary mineralization. Fluid inclusion data indicate that the Hanae Cu-bearing hydrothermal mineralization occurred from dominantly aqueous fluids at temperatures of $400^{\circ}C-200^{\circ}C$. Equilibrium thermodynamic interpretation of the mineral paragenesis and assemblages combined with fluid inclusion data indicate that early main Cu-bearing ore mineralization in the vein starts at about $350^{\circ}C$ which corresponds to sulfur fugacity from about $10^{-9.2}$ to $10^{-8.7}bar$ with oxygen fugacity of about $10^{-32.1}$ to $10^{-29.8}bar$. Late main Cu-bearing ore mineralization in the vein occurs at about $250^{\circ}C$ which corresponds to sulfur fugacity from about $10^{-13.5}$ to $10^{-11.7}bar$ with oxygen fugacity of about $10^{-38.4}$ to $10^{-35.2}bar$. The late Ag-bearing telluride mineralization in the Hanae hydrothermal system occurs at about $200^{\circ}C$ which corresponds to minium Tellirium fugacity value of about $10^{-18}bar$ with sulfur fugacity of about $10^{-14.0}$ to $10^{-10.9}bar$.

Laboratory Performance Evaluation of Alternative Dowel Bar for Jointed Concrete Pavements (콘크리트 포장용 고내구성 대체 다웰바의 실내공용성 평가)

  • Park, Seong Tae;Park, Jun Young;Lee, Jae Hoon;Kim, Hyung Bae
    • International Journal of Highway Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-36
    • /
    • 2013
  • PURPOSES: The problem under this circumstance is that the erosion not only drops strength of the steel dowel bar but also comes with volume expansion of the steel dowel bar which can reduce load transferring efficiency of the steel dowel bar. To avoid this erosion problem, alternative dowers bars are developed. METHODS: In this study, the bearing stresses between the FRP tube dowel bar and concrete slab are calculated and compared with its allowable bearing stress to check its structural stability in the concrete pavement. These comparisons are conducted with several cross-sections of FRP tube dowel bars. Comprehensive laboratory tests including the shear load-deflection test on a full-scale specimen and the full-scale accelerated joint concrete pavement test are conducted and the results were compared with those from the steel dowel bar. RESULTS: In all cross-sections of FRP tube dowel bars, computed bearing stresses between the FRP tube dowel bar and concrete slab are less than their allowable stress levels. The pultrusion FRP-tube dowel bar show better performance on direct shear tests on full-scale specimen and static compression tests at full-scale concrete pavement joints than prepreg and filament-winding FRP-tube dowel bar. CONCLUSIONS: The FRP tube dowel bars as alternative dowel bar are invulnerable to erosion that may be caused by moisture from masonry joint or bottom of the pavement system. Also, the pultrusion FRP-tube dowel bar performed very well on the laboratory evaluation.

Optimal Dimension Design and Stability Analysis of Non-slip Steel Grating (금속 그레이팅의 높이변화에 따른 최적치수 설계 및 안정성 해석)

  • Son, In-Soo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.357-363
    • /
    • 2022
  • In this study, in order to develop an non-slip metal grating, the stability of the grating according to the span of the grating and the gap and height of the bearing bar was evaluated. The optimal shape design of the grating was performed using the results of determining the stability of the grating. The purpose of this study is to determine the stability according to the spacing and height of the bearing bar by applying the design pressure at the design stage to develop the anti-skid grating, and to design the optimal shape for cost reduction. In the optimal design, the target variable was set as the mass, and the optimal design of the grating was performed based on about 20%. Regardless of the height of the bearing bar of the grating, the stress and deformation of the span and the grating showed a proportional tendency to each other, and it was found that the stress decreased as the height of the bearing bar increased. Based on the structural analysis results, an optimal design was performed using mass as the objective variable, and the existing 2mm thickness was changed to 1.6mm, reducing the mass by about 19%. The stress increased by about 4.4% compared to the maximum stress of the existing grating, but the minimum safety factor was 3.1, indicating that the optimally designed grating was stable.

Finite Element Shear Analysis of 3-bar Lap Rubber Specimen for High Damping Rubber Bearing (고감쇠 면진베어링 고무시편의 유한요소 전단해석)

  • Lee, Jae-Han;Yoo, Bong;Park, Ki-Su
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.04a
    • /
    • pp.419-425
    • /
    • 2001
  • The shear modulus of 3-bar lap rubber shear dynamic test specimen is investigated through incremented shear strain tests. The shear force-strain relation of rubber specimen is also calculated by ABAQUS using hyper-elastic material properties of high damping rubber. The analysis results are compatible with shear dynamic tests of 3-bar lap rubber specimen and 1/8 reduced-scale laminated rubber bearing

  • PDF

Finite Element Analytical Study of Steel Plate and Dowel Bar Systems Designed for Damage Reduction of Non-Bearing Walls (비내력벽의 손상제어를 위한 Steel Plate와 Dowel Bar 이격시스템에 대한 유한요소해석)

  • Lim, Chang-Gue;Moon, Kyo Young;Lee, Hong-Seok;Kim, Sung Jig;Kim, Young Nam;Lee, Kihak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.123-130
    • /
    • 2020
  • Generally the non-bearing walls in apartment buildings in Korea are not considered as a lateral force resisting members for the design consideration. This engineering practice caused large crack damages and brittle fractures of the non-bearing walls when subjected to Pohang earthquakes in 2017 since those have not been designed for seismic loading. In this study, finite element analysis was conducted for slot type non-bearing wall connection system to reduce damages and concentrate damages to the designated damping device through separation from the structural wall members. Steel plate and dowel bar systems designed for the dissipation of seismic energies were modeled and analyzed to investigate the damage reductions. Finally, the test result and the analysis result were compared and verified.

Strut-And-Tie Model for Headed Bar Anchored in Exterior Beam-Column Joint with Transverse Reinforcement (전단보강근이 배근된 외부 보기둥 접합부에 정착된 헤드 철근의 스트럿-타이 모델)

  • Chun, Sung-Chul;Hong, Sung-Gul;Oh, Bo-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.454-457
    • /
    • 2006
  • This study presents a strut-and-tie model for the development of headed bars in an exterior beam-column joint with transverse reinforcements. The tensile force of a headed bar is considered to be developed by head bearing together with bond along a bonded length as a partial embedment length. The model requires construction of struts with biaxially compressed nodal zones for head bearing and fan-shaped stress fields against neighboring nodal zones for bond stresses along the bonded length. Due to the existence of transverse reinforcements, the fan-shaped stress fields are divided into direct and indirect fan-shaped stress fields. A required development length and head size of a headed bar can be optimally designed by adjusting a proportion between a bond contribution and bearing contribution.

  • PDF

Pullout Test of Headed Reinforcing Bar in RC or SFRC Members with Side-Face Blowout Failure

  • Lee, Chang-Yong;Kim, Seung-Hun;Lee, Yong-Taeg
    • Architectural research
    • /
    • v.22 no.1
    • /
    • pp.33-39
    • /
    • 2020
  • In this study, side-face blowout failure strength of high strength headed reinforcing bar, which is vertically anchoring between RC or SFRC members, is evaluated throughout pullout test. The major test parameters are content ratio of high strength steel fibers, strength of rebar, length of anchorage, presence of shear reinforcement, and the side concrete cover thickness planned to be 1.3 times of the rebar. In pullout test, tensile force was applied to the headed reinforcing bar with the hinged supports positioned 1.5 and 0.7 times the anchorage length on both sides of the headed reinforcing bar. As a result, the cone-shaped crack occurred where the headed reinforcing bar embedded and finally side-face blowout failure caused by bearing pressure of the headed reinforcing bar. The tensile strength of specimens increased by 13.0 ~26.2% with shear reinforcement. The pullout strength of the specimens increased by 3.6 ~15.4% according to steel fiber reinforcement. Increasing the anchoring length and shear reinforcement were evaluated to reduce the stress bearing ration of the total stress.

Improvement of tip analysis model for drilled shafts in cohesionless soils

  • Chen, Yit-Jin;Wu, Hao-Wei;Marcos, Maria Cecilia M.;Lin, Shiu-Shin
    • Geomechanics and Engineering
    • /
    • v.5 no.5
    • /
    • pp.447-462
    • /
    • 2013
  • An analysis model for predicting the tip bearing capacity of drilled shafts in cohesionless soils is improved in this study. The evaluation is based on large amounts of drilled shaft load test data. Assessment on the analysis model reveals a greater variation in two coefficients, namely, the overburden bearing capacity factor ($N_q$) and the bearing capacity modifier for soil rigidity (${\zeta}_{qr}$). These factors are modified from the back analysis of drilled shaft load test results. Different effective shaft depths and interpreted capacities at various loading stages (i.e., low, middle, and high) are adopted for the back calculation. Results show that the modified bearing capacity coefficients maintain their basic relationship with soil effective friction angle ($\bar{\phi}$), in which the $N_q$ increases and ${\zeta}_{qr}$ decreases as $\bar{\phi}$ increases. The suggested effective shaft depth is limited to 15B (B = shaft diameter) for the evaluation of effective overburden pressure. Specific design recommendations for the tip bearing capacity analysis of drilled shafts in cohesionless soils are given for engineering practice.

Towards an Improved Understanding of Bond Behaviors

  • Choi, Oan Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.239-243
    • /
    • 2003
  • A reducing bearing angle theory for bond of ribbed reinforcing bars to concrete is proposed to simulate experimental observation. Analytical expressions to determine bond strength for splitting and pullout failure are derived, where the bearing angle is a key variable. As bearing angle is reduced, splitting strength decreases and shearing strength increases. The proposed reducing bearing angle theory is effective to simulate damage of the deformed bar-concrete interface and understand bond mechanism of ribbed reinforcing steel in concrete structures.

  • PDF