• 제목/요약/키워드: Beam-Column

검색결과 1,543건 처리시간 0.03초

고장력 철근이 적용된 철근콘크리트 보-기둥 접합부 파괴모드에 대한 실험적 연구 (Experimental Study on Seismic Performance of Beam-column Connections with High Strength Reinforcements)

  • 김대훈;박아론;이기학
    • 한국공간구조학회논문집
    • /
    • 제16권2호
    • /
    • pp.61-68
    • /
    • 2016
  • Behavior of RC(Reinforced-concrete) beam-column connections has been subjected to the earthquake loading has been determined by shear and attachment mechanism. However, since the shear and attachment are very fragile for cycle loadings. Through occurring plastic hinges at the beam, the column and the connection should remain elastic condition and the beam should dissipate the energy from the earthquake. This study was investigate on the seismic performance of 6 RC beam - column connections built with the high strength reinforcements (700MPa) based on design and detailing requirements in the ACI 318-05 Provision and KCI-07 appendix II. This is aimed to evaluate the effect of the high-strength reinforcements as used the beam-column connection members. The main comparisons were the seismic performance of the connections affect the seismic performance in terms of strength, stiffness and ductility, joint shear stress-strain. A total of 6 beam-column specimens were built with a 1/2 scale and subjected to the cyclic loadings. Main design considerations were the area of the longitudinal reinforcements of the beam and details of the beam-column joint designed based on the seismic code. Cyclic test results are given and recommendations for the usage of high strength reinforcements for the seismic design is provided.

철근콘크리트 경사기둥-보 접합부의 거동 (Behavior of Reinforced Concrete Inclined Column-Beam Joints)

  • 권구정;박종욱;윤석광;김태진;이정윤
    • 콘크리트학회논문집
    • /
    • 제24권2호
    • /
    • pp.147-156
    • /
    • 2012
  • 최근 몇 년간 보-기둥 접합부에 영향을 줄 수 있는 경사기둥을 포함한 비정형 구조 시스템을 가진 초고층 빌딩이 증가하고 있다. 경사기둥-보 접합부에 외력이 작용 시 전단과 휨 모멘트의 분포가 정형화된 보-기둥 접합부와 상이하여 접합부의 파괴모드, 전단강도, 연성능력 및 에너지소산능력이 변화할 가능성이 크다. 이 연구에서는 6개의 철근콘크리트 경사기둥-보 접합부($90^{\circ}$, $67.5^{\circ}$, $45^{\circ}$) 실험을 수행하고 결과를 분석하였다. 실험 결과에 의하면 경사기둥-보 접합부에서 비대칭 파괴가 발생하였으며 수직기둥-보 접합부에 비해서 최대하중과 에너지소산능력이 감소하는 것으로 나타났다. 이것은 경사기둥으로 인해 발생되는 접합부의 상이한 모멘트 분포와 압축력만 받는 수직기둥과 다르게 경사기둥이 압축력뿐 아니라 인장력도 작용하기 때문이다.

Strengthening of non-seismically designed beam-column joints by ferrocement jackets with chamfers

  • Li, Bo;Lam, Eddie Siu-Shu;Cheng, Yuk-Kit;Wu, Bo;Wang, Ya-Yong
    • Earthquakes and Structures
    • /
    • 제8권5호
    • /
    • pp.1017-1038
    • /
    • 2015
  • This paper presents a strengthening method that involves the use of ferrocement jackets and chamfers to relocate plastic hinge for non-seismically designed reinforced concrete exterior beam-column joints. An experimental study was conducted to assess the effectiveness of the proposed strengthening method. Four half-scale beam-column joints, including one control specimen and three strengthened specimens, were prepared and tested under quasi-static cyclic loading. Strengthening schemes include ferrocement jackets with or without skeleton reinforcements and one or two chamfers. Experimental results have indicated that the proposed strengthening method is effective to move plastic hinge from the joint to the beam and enhance seismic performance of beam-column joints. Shear stress and distortion within the joint region are also reduced significantly in strengthened specimens. Skeleton reinforcements in ferrocement provide limited improvement, except on crack control. Specimen strengthened by ferrocement jackets with one chamfer exhibits slight decrease in peak strength and energy dissipation but with increase in ductility as compared with that of two chamfers. Finally, a method for estimating moment capacity at beam-column interface for strengthened specimen is developed. The proposed method gives reasonable prediction and can ensure formation of plastic hinge at predetermined location in the beam.

A study on compressive strength of concrete in flexural regions of reinforced concrete beams using finite element analysis

  • Cho, Chang-Geun;Hotta, Hisato
    • Structural Engineering and Mechanics
    • /
    • 제13권3호
    • /
    • pp.313-328
    • /
    • 2002
  • Based on the orthotropic hypoelasticity formulation, a triaxial constitutive model of concrete is proposed. To account for increasing ductility in high confinement of concrete, the ductility enhancement is considered using so called the strain enhancement factor. It is also developed a three-dimensional finite element model for reinforced concrete structural members based on the proposed constitutive law of concrete with the smeared crack approach. The concrete confinement effects due to the beam-column joint are investigated through numerical examples for simple beam and structural beam member. Concrete at compression fibers in the vicinity of beam-column joint behaves dominant not only by the uniaxial compressive state but also by the biaxial and triaxial compressive states. For the reason of the severe confinement of concrete in the beam-column joint, the flexural critical cross-section is observed at a small distance away from the beam-column joint. These observations should be utilized for the economic design when the concrete structural members are subjected to high confinement due to the influence of beam-column joint.

Effect of bolted splice within the plastic hinge zone on beam-to-column connection behavior

  • Vatansever, Cuneyt;Kutsal, Kutay
    • Steel and Composite Structures
    • /
    • 제28권6호
    • /
    • pp.767-778
    • /
    • 2018
  • The purpose of this study is to investigate how a fully restrained bolted beam splice affects the connection behavior as a column-tree connection in steel special moment frames under cyclic loading when located within the plastic hinge zone. The impacts of this attachment in protected zone are observed by using nonlinear finite element analyses. This type of splice connection is designed as slip-critical connection and thereby, the possible effects of slippage of the bolts due to a possible loss of pretension in the bolts are also investigated. The 3D models with solid elements that have been developed includes three types of connections which are the connection having fully restrained beam splice located in the plastic hinge location, the connection having fully restrained beam splice located out of the plastic hinge and the connection without beam splice. All connection models satisfied the requirement for the special moment frame connections providing sufficient flexural resistance, determined at column face stated in AISC 341-16. In the connection model having fully restrained beam splice located in the plastic hinge, due to the pretension loss in the bolts, the friction force on the contact surfaces is exceeded, resulting in a relative slip. The reduction in the energy dissipation capacity of the connection is observed to be insignificant. The possibility of the crack occurrence around the bolt holes closest to the column face is found to be higher for the splice connection within the protected zone.

Behavior of exterior concrete beam-column joints reinforced with Shape Memory Alloy (SMA) bars

  • Azariani, Hossein Rezaee;Esfahani, M. Reza;Shariatmadar, Hashem
    • Steel and Composite Structures
    • /
    • 제28권1호
    • /
    • pp.83-98
    • /
    • 2018
  • This research was conducted to study the behavior of exterior concrete beam-column joints with reinforced shape memory alloy (SMA) bars tested under cyclic loading. These bars benefit from superelastic behavior and can stand high loads without residual strains. The experimental part of the study, 8 specimens of exterior concrete beam-column joints were made and tested. Two different types of concrete with 30 and 45 MPa were used. Four specimens contained SMA bars and 4 specimens contained steel bars in beam-column joints. Furthermore, different transverse reinforcements were used in beams investigate the effects of concrete confinement. Specimens were tested under cyclic loading. Results show that SMA bars are capable of recentering to their original shape after standing large displacements. Due to the superelastic behavior of SMA bars, cracks at the joint core vanish under cyclic loading. As the cyclic loading increased, bending failure occurred in the beam outside the joint core. In the analytical parts of the study, specimens were simulated using the SeismoStruct software. Experimental and analytical results showed a satisfactory correlation. Plastic hinge length at the beam joint for specimens with SMA and steel bars was calculated by empirical equations, experimental and analytical results. It was shown that Paulay's and Priestley's equations are appropriate for concrete beam-column joints in both types of bars.

횡력을 받는 넓은 보-기둥 내부 접합부의 거동 평가 (Behavior of Wide Beam-Column Interior Joint with Slab)

  • 이범식;박성식;박지영
    • 토지주택연구
    • /
    • 제3권4호
    • /
    • pp.433-449
    • /
    • 2012
  • 횡력을 받는 넓은 보와 기둥 내부접합부의 거동을 평가하기 위하여 넓은 보-기둥 접합부의 휨강성비와 유효폭 및 슬래브 유무를 변수로 6개의 1/2축소 모델 실험체를 제작하여 구조성능 평가를 수행하여 하중-변형, 연성, 강성 등을 평가하였다. 동 모델을 대상으로 비탄성해석을 수행하여 구조성능평가 결과와 비교하였다. 연구결과 도출된 결론은 다음과 같다. 넓은 보-기둥 내부 접합부는 중진지역인 국내에서 적용하고 있는 부분골조형 구조에 적용이 가능한 것으로 판단된다. 슬래브의 강성이 횡력을 받는 넓은 보-기둥 내부 접합부의 거동에 영향을 미치는 것으로 나타났다. 휨강성비가 2.0이상의 경우 T형보의 플랜지로서 슬래브 유효폭은 넓은 보 유효깊이의 2.0d로 평가되며, 휨강성비가 1.4~2.0일 경우, 슬래브 유효폭의 영향은 고려하지 않아도 되는 것으로 나타났다.

Behavior of SFRC interior beam-column joints under cyclic loading

  • Khalaf, Noor Ayaad;Qissab, Musab Aied
    • Structural Monitoring and Maintenance
    • /
    • 제7권3호
    • /
    • pp.167-193
    • /
    • 2020
  • In this paper, the behavior of interior steel fiber reinforced concrete beam - column joints (BCJs) under cyclic loading is investigated. An experimental program including tests on twelve reinforced concrete (BCJs) specimens under cyclic loading was carried out. The test specimens are divided into two groups having different geometry: group (G1) (symmetrical BCJs specimens) and group (G2) (nonsymmetrical BCJs specimens). The parameters considered in this study are the steel fibers (SFs) content by volume of concrete (Vf), the spacing of shear reinforcement at the joint region, and the area of longitudinal flexural reinforcement. Test results show that the addition of 0.5% SFs with stirrups spacing S=Smax has effectively enhanced the overall performance of BCJs with respect to energy dissipation, ductility ratio, spreading and width of cracks. The failure of specimens is governed mainly by the formation of a plastic hinge at the face column and outside the beam-column junction. Secondary shear cracks were also observed in the beam-column junctions.

고강도콘크리트를 사용한 보-기둥 접합부의 전단강도 (Shear Strength of Beam-Column eoints Using High-Strength Concrete)

  • 장극관;서대원
    • 콘크리트학회논문집
    • /
    • 제12권2호
    • /
    • pp.53-62
    • /
    • 2000
  • Under severe lateral loads, ductile moments-resisting reinforced concrete frames will be subjected to large loads and displacements. Thus, large deformation and shear stree are occurred at the beam-column joints which are the most critical region in ductile moments-resisting system. The purpose of this study was to investigate the shear strength of beam-column connection using high strength concrete. Four subassemblies were designed 2/3 scale of read structures and tested. The obtained results are as follows. 1) The transverse beams increase the shear resistance and ductility of joint, 2) The slab was contributed to increase of the flexural capacity of the beam, but was not contributed to increase the joint ductility under cyclic loads. 3) The shear stress factors. given by the ACI code would be modified in evaluating the shear strength of beam-column joints of frame which were constructed with high-strength concrete.

Predicting shear strength of RC exterior beam-column joints by modified rotating-angle softened-truss model

  • Wong, Simon H.F.;Kuang, J.S.
    • Computers and Concrete
    • /
    • 제8권1호
    • /
    • pp.59-70
    • /
    • 2011
  • A theoretical model known as the modified rotating-angle softened-truss model (MRA-STM), which is a modification of Rotating-Angle Softened-Truss Model and Modified Compression Field Theory, is presented for the analysis of reinforced concrete membranes in shear. As an application, shear strength and behaviour of reinforced concrete exterior beam-column joints are analysed using the MRA-STM combining with the deep beam analogy. The joints are considered as RC panels and subjected to vertical and horizontal shear stresses from adjacent columns and beams. The strut and truss actions in a beam-column joint are represented by the effective transverse compression stresses and a softened concrete truss in the proposed model. The theoretical predictions of shear strength of reinforced concrete exterior beam-column joints from the proposed model show good agreement with the experimental results.