• 제목/요약/키워드: Beam position monitor

검색결과 29건 처리시간 0.024초

광섬유 센서를 이용한 온도 및 변형 모니터링에 대한 현장응용 사례 (Case Studies on Distributed Temperature and Strain Sensing(DTSS) by using an Optical fiber)

  • 김중열;김유성;이성욱;민경주;박동수;방기성;김강식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.86-95
    • /
    • 2006
  • Brillouin backscatter is a type of reflection that occurs when light is shone into an optical fibre. Brillouin reflections are very sensitive to changes in the fibre arising from external effects, such as temperature, strain and pressure. We report here several case studies on the measurement of strain using Brillouin reflections. A mechanical bending test of an I beam, deployed with both fiber optic sensors and conventional strain gauge rosettes, was performed with the aim of evaluating: (1) the capability and technical limit of the DTSS technology for strain profile sensing; (2) the reliability of strain measurement using fiber optic sensor. The average values of strains obtained from both DTSS and strain gauges (corresponding to the deflection of I beam) showed a linear relationship and an excellent one-to-one match. A practical application of DTSS technology as an early warning system for land sliding or subsidence was examined through a field test at a hillside. Extremely strong, lightweight, rugged, survivable tight-buffered cables, designed for optimal strain transfer to the fibre, were used and clamped on the subsurface at a depth of about 50cm. It was proved that DTSS measurements could detect the exact position and the progress of strain changes induced by land sliding and subsidence. We also carried out the first ever distributed dynamic strain measurement (10Hz) on the Korean Train eXpress(KTX) railway track in Daejeon, Korea. The aim was to analyse the integrity of a section of track that had recently been repaired. The Sensornet DTSS was used to monitor this 85m section of track while a KTX train passed over. In the repaired section the strain increases to levels of 90 microstrain, whereas in the section of regular track the strain is in the region of 30-50 microstrain. The results were excellent since they demonstrate that the DTSS is able to measure small, dynamic changes in strain in rails during normal operating conditions. The current 10km range of the DTSS creates a potential to monitor the integrity of large lengths of track, and especially higher risk sections such as bridges, repaired track and areas at risk of subsidence.

  • PDF

Fetal dose from Head and Neck Tomotherapy Versus 3D Conformal Radiotherapy

  • Park, So Hyun;Choi, Won Hoon;Choi, Jinhyun
    • Journal of Radiation Protection and Research
    • /
    • 제44권4호
    • /
    • pp.156-160
    • /
    • 2019
  • Background: To compare the dose of radiation received by the fetus in a pregnant patient irradiated for head and neck cancer using helical tomotherapy and three-dimensional conformal radiation therapy (3DCRT). Materials and Methods: The patient was modeled with a humanoid phantom to mimic a gestation of 26 weeks. Radiotherapy with a total dose of 2 Gy was delivered with both tomotherapy (2.5 and 5.0 cm jaw size) and 3DCRT. The position of the fetus was predicted to be 45 cm from the field edge at the time of treatment. The delivered dose was measured according to the distance from the field edge and the fetus. Results and Discussion: The accumulated dose to the fetus was 1.6 cGy by 3DCRT and 2 and 2.3 cGy by the 2.5 and 5 cm jaw tomotherapy plans. For tomotherapy, the fetal dose with the 2.5 cm jaw was lower than that with the 5 cm jaw, although the radiation leakage was greater for 2.5 cm jaw plan due to the 1.5 fold longer beam-on time. At the uterine fundus, tomotherapy with a 5 cm jaw delivered the highest dose of 2.4 cGy. When the fetus moves up to 35 cm at the 29th week of gestation, the resultant fetal doses for 3DCRT and tomotherapy with 2.5 and 5 cm jaws were estimated as 2.1, 2.7, and 3.9 cGy, respectively. Conclusion: For tomotherapy, scattering radiation was more important due to the high monitor unit values. Therefore, selecting a smaller jaw size for tomotherapy may reduce the fetal dose. however, evaluation of risk should be individually performed for each patient.

IBM Personal Computer를 이용한 3차원적 뇌정위 방사선 수술계획 시스템의 개발 (Development of 3-D Radiosurgery Planning System Using IBM Personal Computer)

  • 서태석;서덕영;박찬일;하성환;강위생;박승훈;윤세철
    • Radiation Oncology Journal
    • /
    • 제11권1호
    • /
    • pp.167-174
    • /
    • 1993
  • Recently, stereotactic radiosurgery plan is required with the information of 3-D image and dose distribution. A project has been doing if developing LINAC based stereotactic radiosurgery since April 1991. The purpose of this research is to develop 3-D radiosurgery planning system using personal computer. The procedure of this research is based on two steps. The first step is to develop 3-D localization system, which input the image information of the patient, coordinate transformation, the position and shape of target, and patient contour into computer system using CT image and stereotactic frame. The second step is to develop 3-D dose planning system, which compute dose distribution on image plane, display on high resolution monitor both isodose distribution and patient image simultaneously and develop menu-driven planning system. This prototype of radiosurgery planning system was applied recently for several clinical cases. It was shown that our planning system is fast, accurate and efficient while making it possible to handle various kinds of image modalities such as angiography, CT and MRI. It makes it possible to develop general 3-D planning system using beam's eye view or CT simulation in radiation therapy in future.

  • PDF

Mid-Term Performance of Clinical LINAC in Volumetric Modulated Arc Therapy

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Kim, Seonghoon
    • Journal of Radiation Protection and Research
    • /
    • 제44권1호
    • /
    • pp.43-52
    • /
    • 2019
  • Background: The mid-term performance of clinical linear accelerator (LINAC) during volumetric modulated arc therapy (VMAT) treatment period is not performed in clinical practice and usually replaced with one-time plan quality assurance (QA). In this research we aim to monitor daily reproducibility of VMAT delivery from tracking individual leaf movement error and dosimetric error to evaluate the mid-term quality of the machine used. Materials and Methods: First, multileaf collimator (MLC) information was imported into MATLAB program to determine which of the MLC leaves in the leaf bank had the maximum RMS position error (maxRMS). We estimated where the maximum positional errors (maxPE) of the chosen leaf occur along its path length and tracked its daily variations over the entire treatment period. Secondly, picture information of dosimetric error from portal dosimetry was imported into MATLAB where representative high gamma index region (HGR) was determined as HGR with length of > 1 cm and their centers were daily tracked. Results and Discussion: The maxPEs in the brain and tongue cases were distributed broader than in other cases, but all data were found located within ${\pm}0.5mm$. From first day to last day all of five cases show the similar visual pattern of HGRs and Centers of the longest HGRs remained within ${\pm}1mm$ of that in first day. These findings prove excellent mid-term performance of the LINAC used in VMAT treatments over a full course of treatment. Conclusion: Tracking the daily location changes of leaf movement and dosimetric error can be a good indicator of predicting the daily quality like stability and reproducibility of beam delivering in VMAT treatment.

Personal Computer를 이용한 3차원적 뇌정위적 방사선 치료계획 (3-D Radiosurgery Planning Using Personal Computer)

  • 서태석;서덕영;박찬일;하성환;강위생
    • 한국의학물리학회지:의학물리
    • /
    • 제3권1호
    • /
    • pp.63-69
    • /
    • 1992
  • 최근 3차원적인 영상 데이타 및 방사선량 분포에 대한 정보를 필요로하는 뇌정위적 방사선 치료계획이 절실히 요구되고 있다. 본 연구의 목적은 personal computer를 이용하여 3차원적인 환자영상 데이터 및 선량분포를 함께 처리할 수 있는 치료계획 시스템을 개발하는 데 있다. 본 연구를 위한 처리 과정은 크게 3단계로 나누어 수행된다. 첫째, 환자영상 데이타 입력과정으로서, CT, MRI 등 단층촬영영상을 on-line 및 digitizer 방식을 통하여 personal computer에 입력시킨다 병소위치 및 모양도 Angio 및 CT localization 방법을 이용하여 함께 입력시킨다. 둘째, 선량계산 단계로서, stereotactic frame 좌표로 변환된 영상내에서 선량 분포를 계산하고 환자영상 데이타 및 치료기의 조사조건등에 따라 최적 선량분포를 얻는다. 셋째, display 과정으로서, 임의의 단층영상 및 재구성 영상내에서 환자영상과 방사선량에 대한 영상을 합성하여 computer monitor를 통하여 단일 영상내에 동시에 묘출할 수 있도록 처리한다. 본 연구의 치료계획 시스템을 응용한 바 치료계획을 신속하고 정확하게 처리할 수 있었으며, Angio, CT 혹은 MRI와 같은 여러형태의 영상내에서 선량분포를 동시에 묘출함으로써 능률적인 치료계획을 세울 수 있었다. 이와같은 치료계획의 자동화 시스템은 지금까지 어려웠던 3차원적인 뇌정위적 방사선치료계획을 가능케 하며, 추후 beam's eye view나 CT simulation을 통한 일반적인 3차원 방사선 치료계획에도 크게 이바지할 것으로 기대된다.

  • PDF

소켓 용접부 결함 검사용 초음파 자동 검사 장비 개발 (Development of the Automated Ultrasonic Testing System for Inspection of the flaw in the Socket Weldment)

  • 이정기;박문호;박기성;이재호;임성진
    • 비파괴검사학회지
    • /
    • 제24권3호
    • /
    • pp.275-281
    • /
    • 2004
  • 대구경 배관에서 소구경 배관으로 연결하는 부위 및 배관의 방향 전환을 위해 사용하는 소켓용접부는 용입불량 및 사용시간이 경과되면서 내부로부터 진전될 수 있는 균열 등의 결함을 가질 수 있다. 그러나 지금까지 적용하고 있는 비파괴검사법인 액체침투탐상과 방사선투과검사로는 내부에 존재하는 균열성 결함의 검출이 어렵다. 본 연구에서는 소켓용접부 내부의 균열성 결함 검출을 위한 초음파 검사 기법을 확립하였고, 검사를 수행할 수 있는 초음파 탐촉자를 설계 제작하였으며, 자동으로 검사할 수 있는 검사 장비와 제어용 운영 프로그램을 개발하였다. 개발된 장비는 컴퓨터를 기반으로 하고 있으며, pulser/receiver를 내장하고 100 MHz 고속 A/D board를 사용하여 초음파 탐상기 역할을 프로그램으로 구현하였으며, ISA interface type으로 4축 제어용 motion controller를 개발하여 자동 검사를 수행하는 scanner를 제어하도록 하였으며, 검사 결과는 소켓용접부 단면을 실시간 영상으로 나타내도록 되어 있다. 인공결함 시험편의 결함을 평가한 결과 결함의 깊이가 1mm인 결함의 평가 길이는 실제 크기보다 작게 나타내고 있으며, 결함의 깊이가 증가할수록 결함의 길이가 더 크게 평가되었다. 본 연구로 개발한 장비는 원자력 발전소나 화학플랜트에 많이 널려 있는 소켓용접부 내의 용입불량, 피로 균열 등을 검출하여 객관적인 검사 결과를 제시할 수 있으므로 설비 안전 관리 및 보수 부위 결정에 기여할 수 있을 것으로 기대된다.

CBCT와 Simulation CT를 이용한 치료계획의 선량비교 (Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning)

  • 김대영;최지원;조정근
    • 한국콘텐츠학회논문지
    • /
    • 제9권12호
    • /
    • pp.742-749
    • /
    • 2009
  • 최근의 방사선치료용 선형가속기에 부착된 진단용 kV 에너지 영역의 X선 선원과 아모퍼스 실리콘(a-Si)의 검출기로 구성된 온보드영상장치(OBI)를 이용하여 콘빔 전산화단층촬영 영상(CBCT)획득이 가능하다. CBCT영상을 이용하여 치료계획을 세우게 되면 치료실에서 CT영상 촬영이 가능해짐으로써 고식적 치료환자들의 부담이 많이 감소될 수 있고 더 나아가 선량을 재계산하여 치료과정 중 치료계획 재수립도 가능하다. 본 연구에서는 CBCT를 이용한 치료계획과 기존의 모의치료용 CT를 이용한 치료계획을 비교 연구 함으로서 CBCT영상만으로 광자선 선량계산이 정확한지를 평가하고 임상에서 고식적방사선치료를 목적으로 하는 환자들을 대상으로 온라인 방사선치료계획의 가능성을 연구하였다. 선량계산에 필요한 CT수와 밀도간의 상호관계 확인을 위하여 Catphan 600 팬텀을 이용하여 교정곡선을 산출하였고 팬텀과 환자들의 모의 치료용 CT영상과 CBCT영상을 획득하여 치료계획 및 선량계산 된 결과를 비교하였다. CBCT 영상을 이용한 치료계획에서의 MU차이는 중심점에 100cGy 처방하였을 때 Phantom에서의 경우 3~4MU로 약 2.7%, 환자에서의 경우 1~3MU로 약 2.5% 이하로 차이가 났다. 팬텀과 환자에서의 Monitor unit(MU)차이는 2.7%, 2.5% 이내였으나, CBCT영상의 경우 검출기의 크기의 제약 및 환자의 불수의적인 움직임에 의하여 전자밀도가 큰 물질에서 산란선과 artifact의 발생이 크게 증가한다. 따라서 뇌 및 폐 영역의 치료계획시 선량의 오차가 더 커질 수 있어 이에 대한 주의가 요구된다. 치료시작 전 CBCT 영상을 획득하여 환자의 자세와 내부 장기의 위치를 보정하고 선량을 재계산하여 치료계획을 재수립하는 적응방사선치료(ART)를 시행하기 위해서는 산란선과 움직임에 의한 artifact의 감소방안이 마련되어야 할 것으로 사료된다.

CBCT와 Simulation CT를 이용한 치료계획의 선량비교 (Comparison of using CBCT with CT simulator for radiation dose of treatment planning)

  • 조정근;김대영;한태종
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.1159-1166
    • /
    • 2009
  • 최근의 방사선치료용 선형가속기에 부착된 진단용 kV 에너지 영역의 X선 선원과 아모퍼스 실리콘(a-Si)의 검출기로 구성된 온보드영상장치(OBI)를 이용하여 콘빔 전산화단층촬영 영상(CBCT)획득이 가능하다. CBCT영상을 이용하여 치료계획을 세우게 되면 치료실에서 CT영상 촬영이 가능해짐으로써 고식적 치료 환자들의 부담이 많이 감소 될 수 있고 더 나아가 선량을 재계산하여 치료과정 중 치료계획 재수립도 가능하다. 본 연구에서는 CBCT를 이용한 치료계획과 기존의 모의치료용 CT를 이용한 치료계획을 비교 연구 함으로서 CBCT영상만으로 광자선 선량계산이 정확한지를 평가하고 임상에서 고식적방사선치료를 목적으로 하는 환자들을 대상으로 온라인 방사선치료계획의 가능성을 연구하였다. 선량계산에 필요한 CT수와 밀도간의 상호관계 확인을 위하여 Catphan 600 팬텀을 이용하여 교정곡선을 산출하였고 팬텀과 환자들의 모의치료용 CT영상과 CBCT영상을 획득하여 치료계획 및 선량계산 된 결과를 비교하였다. CBCT 영상을 이용한 치료계획에서의 MU차이는 중심점에 100cGy 처방하였을 때 Phantom에서의 경우 3~4MU로 약 2.7%, 환자에서의 경우 1~3MU로 약 2.5% 이하로 차이가 났다. 팬텀과 환자에서의 Monitor unit(MU)차이는 2.7%, 2.5% 이내였으나, CBCT영상의 경우 검출기의 크기의 제약 및 환자의 불수의적인 움직임에 의하여 전자밀도가 큰 물질에서 산란선과 artifact의 발생이 크게 증가한다. 따라서 뇌 및 폐 영역의 치료계획시 선량의 오차가 더 커질 수 있어 이에 대한 주의가 요구된다. 치료시작 전 CBCT 영상을 획득하여 환자의 자세와 내부 장기의 위치를 보정하고 선량을 재계산하여 치료 계획을 재수립하는 적응방사선치료(ART)를 시행하기 위해서는 산란선과 움직임에 의한 artifact의 감소방안이 마련되어야 할 것으로 사료된다.

  • PDF

호흡 동조 체적 세기조절 회전 방사선치료의 유용성 평가와 진폭모드를 이용한 환자적용 (Usefulness of Gated RapidArc Radiation Therapy Patient evaluation and applied with the Amplitude mode)

  • 김성기;임현실;김완선
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.29-35
    • /
    • 2014
  • 목 적 : 본 연구는 이미 상용화가 시작된 호흡 동조 체적 세기조절 회전 방사선 치료(Gated RapidArc) 이전의 자동화가 되지 않는 장비들에서 호흡 동조 방사선 치료(Gated radiation therapy)와 체적 세기조절 회전 방사선 치료(VMAT)를 동시에 시행할 수 있게 Gated RapidArc의 정확성을 분석하여 유용성을 평가하고, 진폭모드(Amplitude mode)를 이용하여 Gated RapidArc가 자동으로 되지 않는 장비에 환자를 적용하여 보고자 하였다. 대상 및 방법 : 방사선량 분포의 분석은 물 등가물질 고체 팬톰과 GafChromic 필름(EBT2 QD+, USA)을 이용하였으며, Film QA (ver. 2.2, USA) 필름 분석 프로그램을 이용하여 Gamma 인자(3%, 3 mm)를 분석하였다. 또한, 삼차원 선량 분포의 정확도를 확인하기 위해서 Matrixx(IBA Dosimery, Germany) 선량 측정 장비와 Compass(IBA Dosimetry, Germany) 선량 분석 프로그램을 이용하였다. 고체 팬톰을 이용한 호흡 동조 주기 신호는 4D 팬톰(Dynamic Thorax Phantom, CIRS, USA)과 Varian RPM(Real-Time Position Monitor) 호흡 동조 시스템을 이용하여 만들었으며, 자유호흡(free breathing)과 호흡정지(breath holding) 시에 따른 방사선량 분포를 각각에 대하여 분석 평가하였다. 환자에게 적용하기 위하여 2013년 2월부터 2013년 8월까지 간암환자 4명을 대상으로 4DCT의 영상을 얻기 위하여 충분한 호흡주기 연습후에 환자의 호흡주기에 맞게 위상모드(Phase mode)를 이용하여 환자가 고글의 호흡주기 패턴을 눈으로 보고 정확하게 따라할 수 있도록 하면서 4DCT의 영상을 획득하였다. Gated RapidArc 치료를 위하여 진폭모드(Amplitude mode)의 호흡주기를 만들어 3회 호흡을 시행한 후 40%~60%의 구간에서 5~6초 호흡을 참을 수 있도록 연습을 하고, 치료 시 40%~60%의 구간에서 환자가 숨을 참을 때 Beam On 버튼을 눌러주는 방식의 반자동으로 치료를 시행하였다. 결 과 : 비 호흡 및 호흡 동조 체적 세기조절 회전 방사선 치료기법 간의 절대선량은 전산화 치료 계획을 이용한 계산값과 1% 이내의 차이를 보였으며, 치료 기법 간의 차이 또한 1% 이내의 차이를 보였다. Gamma 인자(3%, 3 mm)는 99% 이상의 일치함을 보였으며, 각 장기별 선량 차이는 대체로 95% 이상의 일치함을 보였다. 또한 호흡 동조 체적 세기조절 회전 방사선 치료를 위하여 만든 진폭모드(Amplitude mode)의 호흡주기와 실제 환자의 호흡주기가 잘 일치하는 것을 볼 수 있었다. 결 론 : 비 호흡 동조와 호흡 동조 시 체적 세기조절 회전 방사선 치료간의 절대 선량 및 방사선량의 분포가 매우 잘 일치함을 보였다. 이는 호흡 동조 체적 세기조절 회전 방사선 치료 기법을 이용하여 호흡에 따라 움직이는 흉부나 복부의 종양 치료에 적용이 가능한 것으로 사료된다. 또한 실제 치료환자를 대상으로 고글을 통하여 진폭모드(Amplitude mode)의 호흡주기를 만들어 Gated RapidArc가 자동으로 되지 않는 장비에 치료를 적용한 결과, 5~6초정도 정지된 호흡에서 호흡 동조 체적 세기조절 회전 방사선 치료가 원활히 이루어짐을 알 수 있었다.