Surface Characteristics of Type II Anodized Ti-6Al-4V Alloy for Biomedical Applications

  • Lee, Su-Won;Jeong, Tae-Gon;Yang, Jae-Ung;Jeong, Jae-Yeong;Park, Gwang-Min;Jeong, Yong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.77-77
    • /
    • 2017
  • Titanium and its alloys offer attractive properties in a variety of applications. These are widely used for the field of biomedical implants because of its good biocompatibility and high corrosion resistance. Titanium anodizing is often used in the metal finishing of products, especially those can be used in the medical devices with dense oxide surface. Based on SAE/AMS (Society of Automotive Engineers/Aerospace Material Specification) 2488D, it has the specification for industrial titanium anodizing that have three different types of titanium anodization as following: Type I is used as a coating for elevated temperature forming; Type II is used as an anti-galling coating without additional lubrication or as a pre-treatment for improving adherence of film lubricants; Type III is used as a treatment to produce a spectrum of surface colours on titanium. In this study, we have focused on Type II anodization for the medical (dental and orthopedic) application, the anodized surface was modified with gray color under alkaline electrolyte. The surface characteristics were analyzed with Focused Ion Beam (FIB), Scanning Electron Microscopy (SEM), surface roughness, Vickers hardness, three point bending test, biocompatibility, and corrosion (potentiodynamic) test. The Ti-6Al-4V alloy was used for specimen, the anodizing procedure was conducted in alkaline solution (NaOH based, pH>13). Applied voltage was range between 20 V to 40 V until the ampere to be zero. As results, the surface characteristics of anodic oxide layer were analyzed with SEM, the dissecting layer was fabricated with FIB method prior to analyze surface. The surface roughness was measured by arithmetic mean deviation of the roughness profile (Ra). The Vickers hardness was obtained with Vickers hardness tester, indentation was repeated for 5 times on each sample, and the three point bending property was verified by yield load values. In order to determine the corrosion resistance for the corrosion rate, the potentiodynamic test was performed for each specimen. The biological safety assessment was analyzed by cytotoxic and pyrogen test. Through FIB feature of anodic surfaces, the thickness of oxide layer was 1.1 um. The surface roughness, Vickers hardness, bending yield, and corrosion resistance of the anodized specimen were shown higher value than those of non-treated specimen. Also we could verify that there was no significant issues from cytotoxicity and pyrogen test.

  • PDF

Development of Connection Model based on FE Analysis to Ensure Stability of Steel Storage Racks (적재설비 안정성 확보를 위한 FE 해석 기반의 연결부 모델 개발)

  • Heo, Gwanghee;Kim, Chunggil;Yu, Darly;Jeon, Jongsu;Lee, Chinok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.349-356
    • /
    • 2018
  • This paper attempts to develop a connection model based on FE analysis that can be applied to the evaluation of earthquake fragility of Steel Storage Racks lacking research in Korea. In order to accomplish this goal, shaking table tests, modal tests, and various member tests (8 case, push-over test) for structural members have been conducted to understand the behavior of steel storage racks. Based on the experimental results, detailed modeling of the joints was conducted using the NX-Nastran program in order to develop a connection model for Steel storage racks to be applied to the seismic vulnerability assessment. Especially, surface to surface contact element and spring element are applied to simulate the connection between the column member and the beam member connected by the simple latch method. Spring element model developed and applied ARX (Auto Regressive eXogenous) based mathematical model. The simulation results based on the FE model showed excellent reliability with a mutual error rate of less than 8% when compared with the member test results. As a result, it was confirmed that the FE model based connection model developed in the study can be applied to the analytical model for the seismic vulnerability assessment of Steel storage racks.

Rapid Optimization of Multiple Isocenters Using Computer Search for Linear Accelerator-based Stereotactic Radiosurgery (Multiple isocenter를 이용한 뇌정위적 방사선 수술시 컴퓨터 자동 추적 방법에 의한 고속의 선량 최적화)

  • Suh Tae-suk;Park Charn Il;Ha Sung Whan;Yoon Sei Chul;Kim Moon Chan;Bahk Yong Whee;Shinn Kyung Sub
    • Radiation Oncology Journal
    • /
    • v.12 no.1
    • /
    • pp.109-115
    • /
    • 1994
  • The purpose of this paper is to develop an efficient method for the quick determination of multiple isocenters plans to provide optimal dose distribution in sterotactic radiosurgery. A Spherical dose model was developed through the use of fit to the exact dose data calculated in a 18cm diameter of spherical head phantom. It computes dose quickly for each spherical part and is useful to estimate dose distribution for multiple isocenters. An automatic computer search algorithm was developed using the relationship between the isocenter move and the change of dose shape, and adapted with a spherical dose model to determine isocenter separation and cellimator sizes quickly and automatically. A spheric81 dose model shows a comparable isodose distribution with exact dose data and permits rapid calculations of 3-D isodoses. the computer search can provide reasonable isocenter settings more quickly than trial and error types of plans, while producing steep dose gradient around target boundary. A spherical dose model can be used for the quick determination of the multiple isocenter plans with 3 computer automatic search. Our guideline is useful to determine the initial multiple isocenter plans.

  • PDF

Performance Analysis of Complex Phase-code for Phase Multiplexes Holographic Memory System (위상 다중화 홀로그래픽 메모리 시스템을 위한 CPC 위상코드의 성능 분석)

  • 조병철;김정진;김은수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.1C
    • /
    • pp.1-8
    • /
    • 2003
  • In this paper, performance of the CPC(complex phase code) which is recently proposed as a practical phase encoding method for phase-code multiplexes holographic memory system is comparatively analyzed with those of the conventional phase codes such as PR(pure random code), RCE(random code with equality), WHM(Walsh Hadamard Matrix). In computer simulation, the size of an address bean is fixed at 32$\times$32 pixels and 0%-25% phase-error ratio in a pixel are intentionally added to the real phase values to consider the nonlinear phase-modulation characteristics of the practical spatial light modulator. From comparative analysis of crosstalks and signal-to-noise ratios for these phase codes by calculating auto-correlation and cross-correlation, it is found that the CPC have the lowest cross-correlation mean value of 0.021, the lowest standard deviation of 0.0113 and the highest signal-to-noise ratio(SNR) of 27.4 among the four types of phase code. In addition, from the calculation of the number of all possible address beams for these four types of phase code as the size of the address beam is fixed to 3232 pixels, the CPC is found to have 6.334$\times$10$^{49}$ address beams, which are relatively higher number than that of the conventional phase codes.

The Evaluation and Fabrication of Photoconductor Sensor for Quality Assurance of Radiation Therapy Devices (방사선치료기기 정도관리를 위한 광도전체 센서 제작 및 평가)

  • Kang, Sang Sik;Noh, Sung Jin;Jung, Bong Jae;Noh, Ci Chul;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.565-569
    • /
    • 2016
  • Recently, a use of linear accelerator with a multi-leaf collimator(MLC) for radiation therapy is increasing. The importance of quality assurance (QA) for the linear accelerator is emphasized as the side effects of the inaccurate delivery of the radiation beam has been increased according to the high dose irradiation technique. In this study, The $HgI_2$ and $PbI_2$ photoconductor layer samples of $400{\mu}m$ thickness were fabricated using sedimentation method among particle-in-binder technology. From the fabricated samples, the electrical properties(dark current, output current, response properties and linearity) were investigated. From the experimental results, $HgI_2$ has good charge signal generation and linearity. Finally, from the signal response results about various thickness of $HgI_2$ sensor, the signal creation efficiency of $400{\mu}m$ thickness of $HgI_2$ sensor has the highest value and the excellent reproducibility below ${\pm}2.5%$.

An Evaluation Method of X-ray Imaging System Resolution for Non-Engineers (비공학도를 위한 X-ray 영상촬영 시스템 해상력 평가 방법)

  • Woo, Jung-Eun;Lee, Yong-Geum;Bae, Seok-Hwan;Kim, Yong-Gwon
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • Nowadays, digital Radiography (DR) systems are widely used in clinical sites and substitute the analog-film x-ray imaging systems. The resolution of DR images depends on several factors such as characteristic contrast and motion of the object, the focal spot size and the quality of x-ray beam, x-ray scattering, the performance of the DR detector (x-ray conversion efficiency, the intrinsic resolution). The DR detector is composed of an x-ray capturing element, a coupling element and a collecting element, which systematically affect the system resolution. Generally speaking, the resolution of a medical imaging system is the discrimination ability of anatomical structures. Modulation transfer function (MTF) is widely used for the quantification of the resolution performance for an imaging system. MTF is defined as the frequency response of the imaging system to the input of a point spread function and can be obtained by doing Fourier transform of a line spread function, which is extracted from a test image. In clinic, radiologic technologists, who are in charge of system maintenance and quality control, have to evaluate or make routine check on their imaging system. However, it is not an easy task for the radiologic technologists to measure MTF accurately due to lack of their engineering and mathematical backgrounds. The objective of this study is to develop and provide for radiologic technologists a medical system imaging evaluation tool, so that they can measure and quantify system performance easily.

Magnetic Properties of SmCo Thin Films Grown by Using a Nd-YAG Pulsed Laser Ablation Method (Nd-YAG Pulsed Laser Ablation법으로 제작한 SmCo계 박막의 자기특성)

  • 김상원;양충진
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.1
    • /
    • pp.30-36
    • /
    • 2000
  • SmCo films were deposited on Si(100) substrate by a Nd-YAG pulsed laser ablation of the targets of Sm$\_$100-x/Co$\_$x/ (73$\leq$x$\leq$93) at the substrate temperature of 600∼700$\^{C}$ and the laser beam energy density of Q switching mode or fixed Q mode. The magnetic properties of the films obtained from the Q switching mode exhibited a 4 $\pi$ Ms of 5200∼7700 Gauss, iHc of 190-250 Oe, and 4$\pi$M$\_$r//4$\pi$M$\_$s/ of 0.4∼0.74, respectively, while the fixed Q mode gave the magnetic properties of corresponding films of a 4$\pi$M$\_$r//4$\pi$M$\_$s/ = 0.32∼0.91 and iHc of 430-6290 Oe, respectively. The fixed Q mode gave the better magnetic properties of the SmCo films which seems to be due to a formation of magnetically hard minor phases in droplet of Sm-rich intermetallics. However, the resultant rough surface of the SmCo films is a problem to be solved by a continued study.

  • PDF

The Effects of Cynanchi wilfordii Radix Ethanol Extracts upon Irradiated Rat's Blood and Organ (백하수오 에탄올추출물이 방사선조사에 따른 흰쥐의 혈구 및 장기에 미치는 영향)

  • Kim, Jang-Oh;Choi, Jun-Hyeok;Shin, Ji-Hye;Jung, Do-Young;Min, Byung-In
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.451-459
    • /
    • 2016
  • The development of radioprotector is being actively conducted in order to reduce the damage from over radiation exposure at radiation accident or radiation therapy. So this study was confirmed for radiation protective effects using the Cynanchi wilfordii Radix that has been known to be effective for antioxidant activity, anti-cancer, immune enhancing effects. The method of this study was administered orally Cynanchi wilfordii Radix ethanol extracts to Sprague Dawley Rat(SD Rat) for 14 days once a day, while measuring changed blood cell, spleen index, liver and uterus tissue along the change in time of 1, 4, 7 and 21 days after X-ray beam of 7 Gy irradiation. As the result of the experiment, the experimental group's rats which are administered with Cynanchi Wilfordii Radix ethanol extracts showed a rapid recovery in white blood cell count(p < 0.05) and spleen index(p < 0.05). In addition, condensation of nuclei, cytoplasmic swelling, and inflammatory cell infiltration in experimental group's liver cell was decreased more than in irradiation group's component. Further, experimental group's Uterine gland decreased the apoptosis more than irradiation group's components did. It is expected that Cynanchi Wilfordii Radix extracts will be useful as a new radioprotector. With above in mind, this paper may provide appropriate implications with the field of emergency management such as radiation accident.

Effects of Annealing on Ni/Au Ohmic Contact to Nonpolar p-type GaN

  • Lee, Dong-Min;Kim, Jae-Gwan;Yang, Su-Hwan;Kim, Jun-Yeong;Lee, Seong-Nam;Lee, Ji-Myeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.358-359
    • /
    • 2012
  • 최근 분극 특성이 상이한 무분극 GaN 에피성장에 관한 심도 있는 연구와 함께 전자-전공 캐리어의 주입 및 캐리어의 거동, 방출되는 편광 특성 및 다양한 물리적 특성들에 대해 보고되고 있으며, 광학적 특성 및 물리적 특성의 확보를 위한 많은 연구가 활발히 진행 중이다 [1]. GaN의 ohmic 접촉(ohmic contact)의 형성은 발광 다이오드(light emitting diode), 레이저 다이오드(Laser), 태양전지(solar cell)와 같은 고신뢰도, 고효율 광전자 소자를 제조하기 위해서는 매우 중요하다 [2]. 그러나 이와 함께 병행 되어야 할 무분극 p-GaN 의 ohmic contact에 관한 연구는 많이 이루어지고 있지 않는 실정이다. 따라서 본 논문에서는 r-plane 사파이어 기판 상에 성장된 p-GaN에서의 ohmic 접촉 형성 연구를 위하여 Ni/Au ohmic 전극의 접촉저항 특성을 연구하였다. 본 실험에서는 성장된 a-plane GaN의 Hole농도가 $3.09{\times}1017cm3$ 인 시편을 사용하였다. E-beam evaporation 장비를 이용하여 Ni/Au를 각각 20 nm 그리고80 nm 증착 하였으며 비접촉저항을 측정하기 위해 Circle-Transfer Length Method (C-TLM) 패턴을 사용하였다. 샘플은 RTA (Rapid Thermal Annealing)를 사용하여 $300^{\circ}C$에서 $700^{\circ}C$까지 온도를 변화시키며 전기적 특성을 비교하여 그림 1(a) 나타내었다. 그림에서 알 수 있듯이 $400^{\circ}C$에서 가장 낮은 비접촉저항 값인 $6.95{\times}10-3{\Omega}cm2$를 얻을 수 있음을 발견하였다. 이 때의 I-V curve 도 그림1(b)에 나타낸 바와 같이 열처리에 의해 크게 향상됨을 알 수 있다. 그러나, $500^{\circ}C$ 이상 온도를 증가시키면 다시 비접촉 저항이 증가하는 것을 관찰하였다. XRD (x-Ray Diffraction) 분석을 통하여 $400^{\circ}C$ 이상열처리 온도가 증가하면 금속 표면에 $NiO_2$가 형성되며, 이에 따라 오믹특성이 저하 된다고 사료된다. 또한 $Ni_3N$의 존재를 확인 하였으며 이는 nonpolar surface의 특성으로 인해 nitrogen out diffusion 현상이 동시에 발생하여 계면에는 dopant로 작용하는 질소 공공을 남기고 표면에 $Ni_3N$을 형성하여 ohmic contact의 특성이 저하되기 때문인 것으로 사료된다.

  • PDF

Increased Sensitivity of Carbon Nanotube Sensors by Forming Rigid CNT/metal Electrode

  • Park, Dae-Hyeon;Jeon, Dong-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.348-348
    • /
    • 2011
  • Carbon nanotube (CNT) field effect transistors and sensors use CNT as a current channel, of which the resistance varies with the gate voltage or upon molecule adsorption. Since the performance of CNT devices depends very much on the CNT/metal contact resistance, the CNT/electrode contact must be stable and the contact resistance must be small. Depending on the geometry of CNT/electrode contact, it can be categorized into the end-contact, embedded-contact (top-contact), and side-contact (bottom-contact). Because of difficulties in the sample preparation, the end-contact CNT device is seldom practiced. The embedded-contact in which CNT is embedded inside the electrode is desirable due to its rigidness and the low contact resistance. Fabrication of this structure is complicated, however, because each CNT has to be located under a high-resolution microscope and then the electrode is patterned by electron beam lithography. The side-contact is done by depositing CNT electrophoretically or by precipitating on the patterned electrode. Although this contact is fragile and the contact resistance is relatively high, the side-contact by far has been widely practiced because of its simple fabrication process. Here we introduce a simple method to embed CNT inside the electrode while taking advantage of the bottom-contact process. The idea is to utilize a eutectic material as an electrode, which melts at low temperature so that CNT is not damaged while annealing to melt the electrode to embed CNT. The lowering of CNT/Au contact resistance upon annealing at mild temperature has been reported, but the electrode in these studies did not melt and CNT laid on the surface of electrode even after annealing. In our experiment, we used a eutectic Au/Al film that melts at 250$^{\circ}C$. After depositing CNT on the electrode made of an Au/Al thin film, we annealed the sample at 250$^{\circ}C$ in air to induce eutectic melting. As a result, Au-Al alloy grains formed, under which the CNT was embedded to produce a rigid and low resistance contact. The embedded CNT contact was as strong as to tolerate the ultrasonic agitation for 90 s and the current-voltage measurement indicated that the contact resistance was lowered by a factor of 4. By performing standard fabrication process on this CNT-deposited substrate to add another pair of electrodes bridged by CNT in perpendicular direction, we could fabricate a CNT cross junction. Finally, we could conclude that the eutectic alloy electrode is valid for CNT sensors by examine the detection of Au ion which is spontaneously reduced to CNT surface. The device sustatined strong washing process and maintained its detection ability.

  • PDF