• Title/Summary/Keyword: Beam focusing

Search Result 256, Processing Time 0.024 seconds

Treatment Planning and Dosimetry of Small Radiation Fields for Stereotactic Radiosurgery (Stereotactic Radiosurgery를 위한 소형 조사면의 선량측정)

  • Chu Sung Sil;Suh Chang Ok;Loh John J.K.;Chung Sang Sup
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.101-112
    • /
    • 1989
  • The treatment planning and dosimetry of small fields for stereotactic radiosurgery with 10 MV x-ray isocentrically mounted linear accelerator is presented. Special consideration in this study was given to the variation of absorbed dose with field size, the central axis percent depth doses and the combined moving beam dose distribution. The collimator scatter correction factors of small fields $(1\times1\~3\times3cm^2)$ were measured with ion chamber at a target chamber distance of 300cm where the projected fields were larger than the polystyrene buildup caps and it was calibrated with the tissue equivalent solid state detectors of small size (TLD, PLD, ESR and semiconductors). The central axis percent depth doses for $1\timesl\;and\;3\times3cm^2$ fields could be derived with the same acuracy by interpolating between measured values for larger fields and calculated zero area data, and it was also calibrated with semiconductor detectors. The agreement between experimental and calculated data was found to be under $2\%$ within the fields. The three dimensional dose planning of stereotactic focusing irradiation on small size tumor regions was performed with dose planning computer system (Therac 2300) and was verified with film dosimetry. The more the number of strips and the wider the angle of arc rotation, the larger were the dose delivered on tumor and the less the dose to surrounding the normal tissues. The circular cone, we designed, improves the alignment, minimizes the penumbra of the beam and formats ball shape of treatment area without stellate patterns. These dosimetric techniques can provide adequate physics background for stereotactic radiosurgery with small radiation fields and 10MV x-ray beam.

  • PDF

An Evaluation Study of Domestic Direct(Beam) Nomal Solar Radiation Data (국내 직달일사량 자원의 평가 연구)

  • Jo, Dok-Ki;Lee, Tae-Kyu;Kim, Eun-Ill;Chun, Il-Soo;Lee, Soon-Myoung;Cho, Suh-Hyun;Auh, Chung-Moo
    • Solar Energy
    • /
    • v.13 no.1
    • /
    • pp.59-66
    • /
    • 1993
  • Since the direct(beam) normal solar radiation is a main factor for designing any focusing solar system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal solar radiation data since December 1990 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER's new data will be extensively used by concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) $4,400kcal/m^2$. day of the direct(beam) normal solar radiation was evaluated for clear day. 2) Direct normal solar radiation of spring and summer were 6% and 14%, higher than the yearly average value, respectively, and for fall and winter their values were 5% and 15% than the yearly average value, respectively.

  • PDF

Propagation and interaction of two dimensional solitary waves in organic single crystal of polydiacetylene para-toluene sulfonate (유기단결정 Polydiacetylene Para-toluene Sulfonate에서 2차원 공간고립파의 진행과 상호 작용 전산모의)

  • 류재명;조재흥;황보창권;정진호
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.5
    • /
    • pp.400-407
    • /
    • 2002
  • Two dimensional solitary waves are stably propagated in a saturable medium which has a saturable nonlinear index as input intensity. However, in the case of low intensity. a negative fifth-order nonlinear medium has properties of a saturable medium. So a Gaussian beam travels stably. The propagation process into the fifth order nonlinear medium of the Gaussian beam with a weak intensity is investigated by using the computer simulation of the two-dimensional nonlinear Schrodinger equation. As a result, it is confirmed that the two-dimensional spatial solitary waves are stably propagated in this medium when the incident powers are self-trapping powers. In the condition of the phase difference and collisional angle between two input beams of 180 degree and 0.05 degree, respectively, we can confirm that all optical switching is as simple as controlling the incident power of one input beam.

Diverse modeling techniques, parameters, and assumptions for nonlinear dynamic analysis of typical concrete bridges with different pier-to-deck connections: which to use and why

  • Morkos, B.N.;Farag, M.M.N.;Salem, S.;Mehanny, S.S.F.;Bakhoum, M.M.
    • Earthquakes and Structures
    • /
    • v.22 no.3
    • /
    • pp.245-261
    • /
    • 2022
  • Key questions to researchers interested in nonlinear analysis of skeletal structures are whether the distributed plasticity approach - albeit computationally demanding - is more reliable than the concentrated plasticity to adequately capture the extent and severity of the inelastic response, and whether force-based formulation is more efficient than displacement-based formulation without compromising accuracy. The present research focusing on performance-based seismic response of mid-span concrete bridges provides a pilot holistic investigation opting for some hands-on answers. OpenSees software is considered adopting different modeling techniques, viz. distributed plasticity (through either displacement-based or force-based elements) and concentrated plasticity via beam-with-hinges elements. The pros and cons of each are discussed based on nonlinear pushover analysis results, and fragility curves generated for various performance levels relying on incremental dynamic analyses under real earthquake records. Among prime conclusions, distributed plasticity modeling albeit inherently not relying on prior knowledge of plastic hinge length still somewhat depends on such information to ensure accurate results. For instance, displacement-based and force-based approaches secure optimal accuracy when dividing, for the former, the member into sub-elements, and satisfying, for the latter, a distance between any two consecutive integration points, close to the expected plastic hinge length. On the other hand, using beam-with-hinges elements is computationally more efficient relative to the distributed plasticity, yet with acceptable accuracy provided the user has prior reasonable estimate of the anticipated plastic hinge length. Furthermore, when intrusive performance levels (viz. life safety or collapse) are of concern, concentrated plasticity via beam-with-hinges ensures conservative predicted capacity of investigated bridge systems.

Methodologic Aspect of LINAC-based Stereotactic Radiosurgery (선형가속기 기반 뇌정위 방사선 수술기법)

  • Choi, Tae Jin
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.127-137
    • /
    • 2012
  • A conversing beam is firstly designed for radiosurgery by a neurosugern Lars Leksell in 1949 with orthogonal x-rays tube moving through horizontal moving arc to focusing the beam at target center. After 2 decades he composits 201 source of the Co-60 for gamma knife which beams focused at locus. Sveral linac-based stereotactic radiosurgery using the circular collimated beam which size range for 0.4~4.0 cm in a diameter by non-coplanar multiarc have been developed over the decades. The irregular lesions can be treated by superimposing with several spherical shots of radiation over the tumour volume. Linac based techniques include the use of between 4 and 11 non-co-planar arcs and a dynamic rotation technique and use photon beam energies in the range of 6~10 MV. Reviews of the characteristics of several treatment techniques can be found in the literature (Podgorsak 1989, Schell 1991). More in recent, static conformal beams defined by custom shaped collimators or a mini- or micro-multileaf collimator (mMLC) have been used in SRS. Finally, in the last few years, intensity-modulated mMLC SRS has also been introduced. Today, many commercial and in-house SRS programs have also introduced non-invasive immobilization systems include the cyberknife and tomotherapy and proton beam. This document will be compared the characteristics of dose distribution of radiosurgery as introduced gamma knife, BrainLab include photon knife in-house SRS program and cyberknife in currently wide used for a cranial SRS.

Evaluation of Bearing Strength for Composite Joint (합성접합부에서 지압내력 평가식)

  • 김병국;최완철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.347-352
    • /
    • 2002
  • Recent trends in the construction of building frame feature the increase use of composite steel concrete members functioning together in what terms of mixed structural systems. One of such systems, RCS(reinforced concrete column and steel beam) system is introduced and closely examined focusing on bearing strength of the composite joint in this paper. The main objective of this study was to develope one of details to increase bearing capacity while bearing failure is one of the two primary modes of failure in RCS system. Local bearing tests with specimens about 1/3 of the actual concrete column size were performed applying uniform load through steel plate with 100$\times$110mm size. Test results show that specimens with the bearing reinforcement detail developed in this study enhanced the bearing strength by 1.71~3.02 compared to concrete cylinder strength.

  • PDF

The Effects of the Drive-in Process Parameters on the Residual Stress Profile of the p+ Thin Film (후확산 공정 조건이 p+ 박막의 간류 응력 분포에 미치는 영향)

  • Park, T.G.;Jeong, O.C.;Yang, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.1007-1009
    • /
    • 1998
  • In this paper, the effects of the drive-in process parameters on the residual stress profile of the p+ silicon film has been investigated. All the residual stress profile has been estimated by the second-order polynomial. All the coefficients of the polynomial have been determined from the measurement of the deflections of cantilevers and a rotating beam by using a surface profiler meter and by means of focusing a calibrated microscope. As the drive-in temperature or the drive-in time increases, the boron concentration decreases and the magnitude of the average residual stress decreases. If the boron concentration decreases the tensile residual stress decreases except near the surface where the magnitude of compressive residual stress increases.

  • PDF

우주센터 기상 레이더 시스템에 관한 연구

  • Kuk, Bong-Jae;Oh, Chang-Yul;Lee, Hyo-Keun
    • Aerospace Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.133-140
    • /
    • 2004
  • In some cases, the launch vehicle is fatally affected by the change of weather condition. Thus the real time monitoring of weather condition is indispensible for successful launch campaign. This paper described general characteristics of weather radar for space center. The analysis of weather radar requirements has been carried out focusing on the transmitting power, gain of antenna, half power beam width, and minimum detectable signal.

  • PDF

Development and Evaluation of Applications Using Micro-stereolithography Technology (마이크로 광 조형기술을 이용한 3차원 형태의 응용제품 제작 및 이의 평가)

  • 이인환;김동성;조동우;권태헌
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.233-236
    • /
    • 2003
  • The micro-stereolithography technology made it possible to fabricate a freeform 3D micro-structure. Using this technology, two kind of applications were fabricated and tested: micro-lens and micro-mixers. The focal length and f-number of the micro-lens were 5 mm and 2.5, respectively. The focusing ability of the micro-lens was verified by defocusing the He-Ne laser beam after passing the lens. Two mixers are Kenics micro-mixer and BEKM. BEKM is a modified Kenics micro-mixer by introducing barriers on the pipe walt periodically to enhance the mixing via the chaotic mechanism in the helical flow of Kenics micro-mixer. Experimental result shows good mixing performance of developed mixers. Especially, the BEKM shows better mixing performance then Kenics micro-mixer.

  • PDF

Laser Auto Focus Using Non-Touch Sensor (비접촉 센서를 이용한 레이저 자동 포커싱)

  • 장정원;김재구;신보성;장원석;최지연
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.280-283
    • /
    • 2003
  • In this paper, there was finding laser beam focal length using the camera at the work with laser preprocess. A process have some similarity that the laser direct writing was condition of unused other light source in order to a partical object of working substrate, so we worked finding focal length using yellow light. As we found focal lengths from three points of substrate edges, The focal length of all substrates was able to be computed by calculating a plane equation using these three point. Also we make a device and software that can automatically perform all of the processes.

  • PDF