• 제목/요약/키워드: Beam Radiation

검색결과 1,749건 처리시간 0.025초

전자선 처리된 PAN 나노섬유의 열안정화 효과 (Thermal Stabilization Effect of PAN Nanofibers Irradiated by Electron Beam Irradiation)

  • 김두영;전준표;신혜경;강필현
    • 방사선산업학회지
    • /
    • 제6권1호
    • /
    • pp.61-65
    • /
    • 2012
  • Polyacrylonitrile (PAN) is one of the most widely used precursor polymers for making high performance carbon fibers. Conversion of PAN fibers to good quality carbon fibers requires an essential stabilization step prior to carbonization. Electron beam irradiation is an excellent technique for modifying the physical properties of materials. This study aimed to elucidate the effects of electron beam irradiation on the stabilization reactions of PAN nanofibers. FT-IR analysis indicated that the stabilization of irradiated PAN nanofibers was initiated at a lower temperature. The TG curve of PAN nanofibers showed a significant decrease of weight loss step between 280 and $320^{\circ}C$. In the case of irradiated PAN nanofibers, weight loss sudden weight did not loss occurs.

Dose Calculation of Photon Beam with Wedge Filter for Radiation Therapy Planning System

  • Cheong, Kwang-Ho;Suh, Tae-Suk;Lee, Hyoung-Koo;Choe, Bo-Young
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.41-41
    • /
    • 2003
  • Purpose: Even if the wedge filter is widely used for the radiation therapy to modify the photon beam intensity, the wedged photon beam dose calculation is not so easy. Radiation therapy planning systems (RTPS) have been used the empirical or semi-analytical methods such as attenuation method using wedge filter parameters or wedge filter factor obtained from measurement. However, these methods can cause serious error in penumbra region as well as in edge region. In this study, we propose the dose calculation algorithm for wedged field to minimize the error especially in the outer beam region. Materials and Method: Modified intensity by wedge filter was calculated using tissue-maximum ratio (TMR) and scatter-maximum ratio (SMR) of wedged field. Profiles of wedged and non-wedged direction was also used. The result of new dose calculation was compared with measurement and the result from attenuation method. Results: Proposed algorithm showed the good agreement with measurement in the high dose-gradient region as well as in the inner beam region. The error was decreased comparing to attenuation method. Conclusion: Although necessary beam data for the RTPS commissioning was increased, new algorithm would guarantee the improved dose calculation accuracy for wedged field. In future, this algorithm could be adopted in RTPS.

  • PDF

레이저 가공시 에너지 전달과 Plume 효과 (Laser- Plume Effects on Radiation Energy Transfer in Materials Processing)

  • Kang, Kae-Myung;Kim, Kwang-Ryul
    • 한국재료학회지
    • /
    • 제12권1호
    • /
    • pp.27-35
    • /
    • 2002
  • In laser materials processing, localized heating, melting and evaporation caused by focused laser radiation forms a vapor on the material surface. The plume is generally an unstable entity, fluctuating according to its own dynamics. The beam is refracted and absorbed as it traverses the plume, thus modifying its power density on the surface of the condensed phases. This modifies material evaporation and optical properties of the plume. A laser-produced plasma plume simulation is completed using axisymmetric, high-temperature gas dynamic model including the laser radiation power absorption, refraction, and reflection. The physical properties and velocity profiles are verified using the published experimental and numerical results. The simulation results provide the effect of plasma plume fluctuations on the laser power density and quantitative beam radius changes on the material surface. It is proved that beam absorption, reflection and defocusing effects through the plume are essential to obtain appropriate mathematical simulation results. It is also found that absorption of the beam in the plume has much less direct effect on the beam power density at the material surface than defocusing does and helium gas is more efficient in reducing the beam refraction and absorption effect compared to argon gas for common laser materials processing.

전자선 조사를 이용한 히알루론산의 특성 조절 (Modulation of Hyaluronic Acid Properties by Electron Beam Irradiation)

  • 신영민;김우진;김용수;조선영;박종석;권희정;임윤묵;노영창
    • 방사선산업학회지
    • /
    • 제5권2호
    • /
    • pp.159-164
    • /
    • 2011
  • A variety of natural polymers have been used as tissue engineering scaffolds, drug delivery system, and cosmetic materials due to their higher biocompatibility and water uptake. As a major component of extracellular matrix, hyaluronic acid consisting of D-glucuronic acid and N-acetylglucosamine has been popularly used as a hydrogel material. Even though it has good properties to be used in the tissue engineering and cosmetic industry, its higher viscosity has limited a potential use in a variety of applications; only low content should be applied in preparing above products. In the present study, we investigated the effect of electron beam irradiation on the properties of hyaluronic acid. Hyaluronic acid paste containing low contents of water changed to solution after electron beam irradiation ranging from 1 to 10 kGy, which didn't exhibit any alteration of surface properties and morphological change after freeze-drying. However, its viscosity was significantly decreased as absorbed dose increased, which was approximately one by hundred in comparison with the viscosity of original hyaluronic acid solution with same concentration. In addition, it can still interact with positive charged chitosan generating polyelectrolyte complex. Therefore, only viscosity was decreased after electron beam irradiation, whereas other properties of hyaluronic acid maintained. Consequently, these hyaluronic acids with lower viscosities can be used in a variety of applications in tissue engineering, drug delivery, and cosmetic industry.

Carboxymethycellulose의 농도에 따른 방사선 분해 연구 (Effect of Concentration of Carboxymethycellulose on Degradation by Radiation)

  • 김정수;성낙윤;김재훈;김태운;이주운;최종일
    • 방사선산업학회지
    • /
    • 제4권4호
    • /
    • pp.385-389
    • /
    • 2010
  • In this study, the effect of the concentration of carboxymethylcellulose (CMC) solution on the degradation by irradiation was investigated. The CMC solutions with different concentrations of 3%, 4%, 5%, 6% and 7% were irradiated at the doses of 5, 10, 15, 20, 25 and 30 kGy with gamma ray or electron beam, and the viscosity of CMC solution was measured. The viscosity of the CMC solutions was decreased with an increase in the irradiation dose, but the extent of the degradation by an irradiation was found to be decreased with an increase of the CMC concentration in the solution. The dependency of the irradiation sources showed that an electron beam radiation had degraded the CMC less severely than gamma ray.

치과방사선 검사 시 방사선작업종사자의 위치에 따른 방사선 노출 평가 (Radiation Exposure Evaluation Depending on Radiation Workers' Locations during Dental Radiography)

  • 정천수;김지영
    • 한국방사선학회논문지
    • /
    • 제9권7호
    • /
    • pp.433-438
    • /
    • 2015
  • 치과방사선 검사에 있어 방사선작업종사자의 위치에 따라 방사선 노출 정도를 평가하고자 촬영실과 납유리, 조작대에서 방사선량률을 측정하였다. 사용된 장치로는 Standard(Max-GLS, Shinhung), 파노라마(PCH-2500, Vatech), 세팔로(PCH-2500), Cone beam CT(PHT-30LFO, Vatech)이며, 방사선측정기는 PM1405 장비이다. 촬영조건은 임상에서 사용하는 인자와 동일하게 설정하였다. 그 결과 촬영실 안에서는 Cone beam CT가 98 uSv/h로 가장 높았으며, standard가 0.4 uSv/h로 가장 낮은 수치를 보였다. 또 파노라마가 촬영방식이 다름으로 인하여 세팔로 보다 높게 측정되었다. 납유리 표면과 조작대에서는 구강내와 파노라마, 세팔로는 모두 기록준위 이하로 측정되었지만, Cone beam CT는 누설선량이 있는 것으로 측정되었다. 이에 방사선작업종사는 적절한 방호도구를 하고 촬영시간을 최대한 줄여야 한다. 또, 방사선실의 구조 또한 효율적으로 설계해야 할 것이다. 치과방사선검사는 최근 지속적으로 증가하고 있기 때문에 환자와 방사선작업종사자에 대한 적절한 방호 대책이 필요하다.

단자엽 모델 식물의 방사선원 별 처리에 따른 유전적 다형성 분석 (Genetic Relationship of Mono-cotyledonous Model Plant by Ionizing Irradiation)

  • 송미라;김선희;장덕수;강시용;김진백;김상훈;하보근;김동섭
    • 방사선산업학회지
    • /
    • 제6권1호
    • /
    • pp.23-29
    • /
    • 2012
  • In this study, we investigated the genetic variation in the general of monocot model plant (rice) in response to various ionizing irradiations including gamma-ray, ion beam and cosmic-ray. The non-irradiated and three irradiated (200 Gy of gamma-ray and 40 Gy of ion beam and cosmic-ray) plants were analyzed by AFLP technique using capillary electrophoresis with ABI3130xl genetic analyzer. The 29 primer combinations tested produced polymorphism results showing a total of 2,238 bands with fragments sizes ranged from 30 bp to 600 bp. The number of polymorphism generated by each primer combinations was varied significantly, ranging from 2 (M-CAC/E-ACG) to 158 (M-CAT/E-AGG) with an average of 77 bands. Polymorphic peaks were detected as 1,269 with an average of 44 per primer combinations. By UPGMA (Unweighted Pair Group Method using Arithmetic clustering) analysis method, the clusters were divided into non-irradiated sample and three irradiated samples at a similarity coefficient of 0.41 and three irradiation samples was subdivided into cosmic-ray and two irradiation samples (200 Gy of gamma-ray and 40 Gy of ion beam) at similarity coefficient of 0.48. Similarity coefficient values ranged from 0.41 to 0.55.

Patient radiation dose and protection from cone-beam computed tomography

  • Li, Gang
    • Imaging Science in Dentistry
    • /
    • 제43권2호
    • /
    • pp.63-69
    • /
    • 2013
  • After over one decade development, cone beam computed tomography (CBCT) has been widely accepted for clinical application in almost every field of dentistry. Meanwhile, the radiation dose of CBCT to patient has also caused broad concern. According to the literature, the effective radiation doses of CBCTs in nowadays market fall into a considerably wide range that is from $19{\mu}Sv$ to $1073{\mu}Sv$ and closely related to the imaging detector, field of view, and voxel sizes used for scanning. To deeply understand the potential risk from CBCT, this report also reviewed the effective doses from literatures on intra-oral radiograph, panoramic radiograph, lateral and posteroanterior cephalometric radiograph, multi-slice CT, and so on. The protection effect of thyroid collar and leaded glasses were also reviewed.

Age diffusion model을 이용한 전자선량 분포에 대한 연구 (A Study on the Electron Beam Distribution based on Age-diffusion Model)

  • 김성현;서태석;나유진
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.161-163
    • /
    • 1997
  • In this paper, a two-dimensional electron beam dose calculational algorithm implented for use in a two-dimensional radiation therapy planning system is described. The 2-D electron beam calculations have been in use clinically for a few decades. Our algorithm uses Age-diffusion model based int the Boltzman Transport Equation. Our implementation provides convenient user interface associated with electron beam therapy planning and displays radiation dose distribution according to different electron energy on patient images.

  • PDF

상호 간섭 영향을 고려한 평면 배열형 음향 트랜스듀서의 방사 출력 예측 (A Prediction of Radiation Power for the Planar Array Acoustic Transducer Considering Mutual Coupling Effects)

  • 이종길;서인창
    • 한국음향학회지
    • /
    • 제15권1호
    • /
    • pp.17-22
    • /
    • 1996
  • 소나 시스템에 주로 사용이 되는 평면 배열형 음향 트랜스듀서는 수중에서 음을 방사하여 빔(beam)을 형성하게 된다. 이러한 빔은 트랜스듀서 진동체에서 발생하는 음향 출력이 공간상에 분포되어 일어난다. 따라서 방사 출력의 산출은 트랜스듀서의 성능 및 효율을 예측하는데 필요하다. 본 논문에서는 무한 배플에 고정된 9개의 음향 진동체를 모델로 선정하였다. 개별 진동체에서의 음향 방사량은 자기방사 및 상호방사의 조합으로 표현이 되며 전기적 등가회로 기법을 이용하여 진동체 상호간의 음향 간섭 영향을 고려하여 평면 배열형 음향 트랜스듀서 진동체의 방사 출력 예측 기법을 제안 하였다.

  • PDF