• Title/Summary/Keyword: Beam Radiation

Search Result 1,777, Processing Time 0.031 seconds

Thermal Performance Variations of Glass Evacuated Tube Solar Collectors Depending on the Absorber Shape and the Incidence Angle of Solar Ray (흡수관 형상과 일사 각도에 따른 진공관형 태양열 집열기의 성능 변화)

  • Kim Yong;Seo Tae-Beom;Kang Yong-Heack
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.659-668
    • /
    • 2005
  • The thermal performances of glass evacuated tube solar collectors are numerically investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are numerically investigated. Dealing with only collecting tube, the effects of not only the shape of the absorber tube but also the incidence angle of solar irradiation on the thermal performance of the collector are studied because the energy obtained by the absorber can be varied according to the incidence angle of solar radiation. However, the solar irradiation consists of the beam radiation as well as the diffuse radiation. Also, in actual system, the interference of solar irradiation and heat transfer interaction between the tubes should be considered. Therefore, this study considered these effects is carried out experimentally and numerically. The accuracy of the numerical model is verified by experiments. The result shows that the thermal performance of the absorber used a plate fin and U-tube is about $25\%$ better than those of the other models.

Fabrication and performance evaluation of one-dimensional fiber-optic radiation sensor for X-ray profile irradiated by clinical linear accelerator (의료용 선형가속기의 X-선 분포도 측정을 위한 1차원 광섬유 방사선 센서의 제작 및 성능평가)

  • Cho, Dong-Hyun;Jang, Kyoung-Won;Yoo, Wook-Jae;Lee, Bong-Soo;Cho, Hyo-Sung;Kim, Sin
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.33-38
    • /
    • 2007
  • In this study, one-dimensional fiber-optic radiation sensor with an organic scintillator tip is fabricated to measure high energy X-ray beam profile of CLINAC. According to the energy and field size of X-ray, scintillating light signal from one-dimensional fiber-optic sensor is measured using a photodiode-amplifier system. This sensor has many advantages such as high resolution, real-time measurement and ease calibration over conventional ion chamber and film.

A Study on the Radiation Characteristics of the Conical Corrugated Feed Horn using the Gaussian Beam Mode (가우시안 빔 모드에 의한 원뿔형 컬러게이트 급전 혼의 복사특성에 관한 연구)

  • 장대석;이상설
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.3
    • /
    • pp.515-522
    • /
    • 1994
  • The radiation characteristics of the conical corrugated feed horn are analyzed by the Gaussian beam mode theory. the electric field over the aperture can be expanded in terms of a set of Gaussian-Laguerre modes. It is proved that these modes are the solutions of the wave epuations for the paraxial approximation. A method, using the sum of the mode expansion coefficients instead of calculation only the fundamental mode, is presented in order to reduce the radiation pattern error. For illustrative examples, the radiation patterns of the corrugated horn antenna operting over C, Ku, and mm-wave band are calculated. Our results agree well with the results obtained by the vector potential method over each band, and also agree well with the measured value at 6.175GHz.

  • PDF

The Radiation Characteristics of a Linear Phased Array Antenna using a Pin Array Patch Antenna as an Element (핀 배열 안테나를 단위 안테나로 사용한 선형 위상 배열 안테나의 방사 특성)

  • Kim, Tae-Young;Kim, Gun-Su;Kim, Boo-Gyoun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.12
    • /
    • pp.44-51
    • /
    • 2009
  • The radiation characteristics of a pin array patch antenna phased array are compared to those of a conventional patch antenna phased array. The performance of a pin array patch antenna phased array is much improved than that of a conventional patch antenna phased array because the mutual coupling between the adjacent pin array patch antennas is very small compared to that between the adjacent conventional patch antennas. The radiation characteristics of a pin array patch antenna phased array show the superior performance such as low variation of the gain of the main beam and the side lobe level for the variation of the direction of the main beam.

Test of a Multilayer Dose-Verification Gaseous Detector with Raster-Scan-Mode Proton Beams

  • Lee, Kyong Sei;Ahn, Sung Hwan;Han, Youngyih;Hong, Byungsik;Kim, Sang Yeol;Park, Sung Keun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.5
    • /
    • pp.297-304
    • /
    • 2015
  • A multilayer gaseous detector has been developed for fast dose-verification measurements of raster-scan-mode therapeutic beams in particle therapy. The detector, which was constructed with eight thin parallel-plate ionization chambers (PPICs) and polymethyl methacrylate (PMMA) absorber plates, is closely tissue-equivalent in a beam's eye view. The gas-electron signals, collected on the strips and pad arrays of each PPIC, were amplified and processed with a continuous charge.integration mode. The detector was tested with 190-MeV raster-scan-mode beams that were provided by the Proton Therapy Facility at Samsung Medical Center, Seoul, South Korea. The detector responses of the PPICs for a 190-MeV raster-scan-mode proton beam agreed well with the dose data, measured using a 2D ionization chamber array (Octavius model, PTW). Furthermore, in this study it was confirmed that the detector simultaneously tracked the doses induced at the PPICs by the fast-oscillating beam, with a scanning speed of 2 m s-1. Thus, it is anticipated that the present detector, composed of thin PPICs and operating in charge.integration mode, will allow medical scientists to perform reliable fast dose-verification measurements for typical dynamic mode therapeutic beams.

Measurement of temperature profile in molter metal using a cod camera (ccd 카메라를 이용한 금속 용융면의 온도분포측정)

  • 노시표;정의창;임창환;김철중
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.1
    • /
    • pp.64-69
    • /
    • 2003
  • Using a high fewer electron beam gun (max. power 20 kW), Gadolinium (Gd, atomic number 64) metal was melted and the temperature distribution of melted surface was measured. With proper optical filters and the adjustment of aperture of lens, the radiation of melted surface was received by a ccd camera and its signal transferred to a computer. The real time monitoring of melted surface with a variation of electron beam Power was Possible and stable operation of electron beam was achieved. It was found that the max. temperature measured by a ccd camera with an assumption of blackbody radiation of melted Gd surface and adaption of Planet's law was above 100~$200^{\circ}C$ compared to that measured by a pyrometer in the same e-beam power.

Study of photon beam quality tool at magnetic field change in bending magnet (편향전자석의 자장변화에 따른 광자선 선질평가에 관한 고찰)

  • Kim, Jeong-Ho;Yoo, Se-Jong;Park, Myeong-Cheol;Bae, Seok-Hwan;Kim, Ki-Jin
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.433-439
    • /
    • 2014
  • Beam quality is changed about magnetic field of bending magnet. Evaluation of beam quality using PDD(Percentage Depth Dose) at 10cm depth at recommendation of AAPM(America Academy of Pain Medicine). However this evaluation shows fragmentary element. Therefore this study is applied to three value, 10cm divided by 5cm depth PDD, 20cm divided by 10cm depth PDD, 30cm divided by 20cm depth PDD, at change the magnetic field. PDD is measured at magnetic field changed ${\pm}1%$, ${\pm}2%$ at 6MV(Mega Voltage), 10MV photon. The plan technique is 3 portal plan using Core-Plan at human pelvic phantom. Conventional and presented methods are compared at maximum and minimum dose. The presented method increased discernment of relieve the unequal distribution and energy area than conventional method. Henceforth, application of presented method will be considered. Development of energy measurement method and detector miniaturization will be needed about continuous study.

Analysis of Axially Displaced Ellipse Gregorian Dual Reflector Antennas (축이동 그레고리안 이중 반사경 안테나의 해석)

  • 임성빈;최경국;최학근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.11
    • /
    • pp.1161-1169
    • /
    • 2003
  • In this paper, ADE(Axially Displaced Ellipse) Gregorian dual reflector antennas, which are the special form of Gregorian dual reflector antennas, were analyzed. In the procedure of antenna analysis, the aperture field distribution was obtained by using the geometrical optics and their far-field radiation characteristics were analyzed by using the aperture field method. The analysis results such as antenna efficiency, HPBW(Half Power Beam Width), FNBW(First Null Beam Width), and FSL(First Sidelobe Level) were presented as functions of edge taper and size of main reflector and subreflector. From the results in this paper, we could confirm that ADE reflector antennas have the different radiation characteristics from the classical dual reflector antennas.

Absorbed and effective dose from newly developed cone beam computed tomography in Korea (최근 개발된 cone beam computed tomography의 흡수선량 및 유효선량 평가)

  • Lee, Jong-Nyeong;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.37 no.2
    • /
    • pp.93-102
    • /
    • 2007
  • Purpose: Cone beam computed tomography (CBCT) provides a lower dose and cost alternative to conventional CT, promising to revolutionize the practice of oral and maxillofacial radiology. The purpose of this study was to evaluate the absorbed and effective doses of Implagraphy and VCT (Vatech Co., Hwasung, Korea) and compare them with those of panoramic radiography. Materials and Methods: Thermoluminescent dosimeter (TLD) chips were placed at 27 sites throughout the layers of Female ART Head and Neck Phantom for dosimetry. Implagraphy, VCT units, and Planmeca Proline XC panoramic unit were used for radiation exposures. Radiation weighted doses and effective doses were measured and calculated using 1990 and 2005 ICRP tissue weighting factors. Results: Effective doses in Sv (ICRP 2005, ICRP 1990) were 90.19, 61.62 for Implagraphy at maxillay molar area, 123.20, 90.02 for Implagraphy at mandibular molar area, 183.55, 139.26 for VCT and 40.92, 27.16 for panoramic radiography. Conclusion: Effective doses for VCT and Implagraphy were only about 2.2 to 4.5 times greater than those for panoramic radiography. VCT and Implagraphy, CBCT machines recently developed in Korea, showed moderately low effective doses.

  • PDF

Photocatalytic activities and surface properties of e-beam treated carbon paper deposited $TiO_2$ using Atomic Layer Deposition (ALD)

  • Kim, Myoung-Joo;Seo, Hyun-Ook;Luo, Yuan;Kim, Kwang-Dae;Kim, Young-Dok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.345-345
    • /
    • 2010
  • Thin film of $TiO_2$ deposited on carbon paper was fabricated by atomic layer deposition (ALD) using titanium isopropoxide (TTIP) and $H_2O$ as precursors. In this work, the photocatalytic activities of $TiO_2$ films with and without e-beam treatment were compared. The samples were treated by e-beam using e-beam energy of 1MeV and exposure range between 5 and 15kGy. The photocatalytic activity was evaluated by the photocatalytic degradation of methyleneblue (MB) under UV irradiation (365nm) at room temperature using an UV-vis spectroscopy. The surface properties were characterized by scanning electron microscope (SEM) and X-ray photoelectron spectroscopy (XPS). The sample treated by the low radiation dose has more catalytic activity than other ones. SEM images show that the high radiation dose caused the $TiO_2$ to aggregation on carbon paper. Due to the aggregation of $TiO_2$, the partially exposed carbon paper was oxidized.

  • PDF