• Title/Summary/Keyword: Beam Factor

Search Result 1,010, Processing Time 0.026 seconds

The Fabrication of $n^+-p^+$ InP Solar Cells by the Diffusion of Sulphur (S확산에 의한 $n^+-p^+$ InP 태양전지의 제작)

  • Jung, Ki-Ung;Kim, Seon-Tai;Moon, Dong-Chan
    • Solar Energy
    • /
    • v.10 no.3
    • /
    • pp.60-65
    • /
    • 1990
  • [ $n^+-p^+$ ] InP homojunction solar cells were fabricated by thermal diffusion of sulphur into a $p^+$-InP wafer($p=4{\times}10^{18}cm^{-3}$), and a SiO film($600{\AA}$ thick) was coated on the $n^+$ layer as an antireflection(AR) coating by an e-beam evaporator. The volume of the cells were $5{\times}5{\times}0.3mm^3$. The front contact grids of the cells with 16 finger pattern of which width and space were $20{\mu}m$ and $300{\mu}m$ respectively, were formed by photo-lithography technique. The junction depth of sulphur were as shallow as about 0.4r m We found out the fabricated solar cells that, with increasing the diffusion time, short circuit current densities($J_{sc}$), series resistances($R_s$) and energy conversion efficiencies(${\eta}$) were increased. The cells show good spectral responses in the region of $5,000-9,000{\AA}$. The short circuit current density, the open circuit voltage( $V_{oc}$), the fill factor(F.F) and the energy conversion efficiency of the cell were $13.16mA/cm^2$, 0.38V, 53.74% and 10.1% respectively.

  • PDF

Neuroprotective potential of imatinib in global ischemia-reperfusion-induced cerebral injury: possible role of Janus-activated kinase 2/signal transducer and activator of transcription 3 and connexin 43

  • Wang, Jieying;Bai, Taomin;Wang, Nana;Li, Hongyan;Guo, Xiangyang
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.24 no.1
    • /
    • pp.11-18
    • /
    • 2020
  • The present study was aimed to explore the neuroprotective role of imatinib in global ischemia-reperfusion-induced cerebral injury along with possible mechanisms. Global ischemia was induced in mice by bilateral carotid artery occlusion for 20 min, which was followed by reperfusion for 24 h by restoring the blood flow to the brain. The extent of cerebral injury was assessed after 24 h of global ischemia by measuring the locomotor activity (actophotometer test), motor coordination (inclined beam walking test), neurological severity score, learning and memory (object recognition test) and cerebral infarction (triphenyl tetrazolium chloride stain). Ischemia-reperfusion injury produced significant cerebral infarction, impaired the behavioral parameters and decreased the expression of connexin 43 and phosphorylated signal transducer and activator of transcription 3 (p-STAT3) in the brain. A single dose administration of imatinib (20 and 40 mg/kg) attenuated ischemia-reperfusion-induced behavioral deficits and the extent of cerebral infarction along with the restoration of connexin 43 and p-STAT3 levels. However, administration of AG490, a selective Janus-activated kinase 2 (JAK2)/STAT3 inhibitor, abolished the neuroprotective actions of imatinib and decreased the expression of connexin 43 and p-STAT3. It is concluded that imatinib has the potential of attenuating global ischemia-reperfusion-induced cerebral injury, which may be possibly attributed to activation of JAK2/STAT3 signaling pathway along with the increase in the expression of connexin 43.

A Model-Fitting Approach of External Force on Electric Pole Using Generalized Additive Model (일반화 가법 모형을 이용한 전주 외력 모델링)

  • Park, Chul Young;Shin, Chang Sun;Park, Myung Hye;Lee, Seung Bae;Park, Jang Woo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.11
    • /
    • pp.445-452
    • /
    • 2017
  • Electric pole is a supporting beam used for power transmission/distribution which accelerometer are used for measuring a external force. The meteorological condition has various effects on the external forces of electric pole. One of them is the elasticity change of the aerial wire. It is very important to perform modelling. The acceleration sensor is converted into a pitch and a roll angle. The meteorological condition has a high correlation between variables, and selecting significant explanatory variables for modeling may result in the problem of over-fitting. We constructed high deviance explained model considering multicollinearity using the Generalized Additive Model which is one of the machine learning methods. As a result of the Variation Inflation Factor Test, we selected and fitted the significant variable as temperature, precipitation, wind speed, wind direction, air pressure, dewpoint, hours of daylight and cloud cover. It was noted that the Hours of daylight, cloud cover and air pressure has high explained value in explonatory variable. The average coefficient of determination (R-Squared) of the Generalized Additive Model was 0.69. The constructed model can help to predict the influence on the external forces of electric pole, and contribute to the purpose of securing safety on utility pole.

Carbon strain sensor using Nd: YAG laser Direct Writing (Nd:YAG Laser 직접 각인을 이용한 Carbon 스트레인 센서)

  • Joo, Donghyun;Yoon, Sangwoo;Kim, Joohan;Park, Woo-Tae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.1
    • /
    • pp.35-40
    • /
    • 2018
  • Nd:YAG laser was used to carbonize polyimide films to produce carbon films. This is a simple manufacturing process to fabricate low cost sensors. By applying this method, we studied characteristics of flexible and low-cost piezoresistive. Previously, many studies focused on carbonization of polyimide using $CO_2$ laser with wavelength of $10.6{\mu}m$. In this paper, carbonization (carbonization process) was performed on polyimide films using an Nd:YAG laser with a wavelength of $1.064{\mu}m$. In order to increase the resolution, we optimized the laser conditions of the power density ($W/cm^2$) and the beam scan rate. In previous studies using $CO_2$ laser, the minimum line width was $140{\sim}220{\mu}m$ but in this study, carbon line width was reduced to $35{\sim}40{\mu}m$. The initial sheet resistance of the carbon sensor was $100{\sim}300{\Omega}/{\square}$. The resistance decreased by 30% under stretched with a curvature radius of 21 R. The calculated gauge factor was 56.6. This work offers a simple, highly flexible, and low-cost process to fabricate piezoresistive sensors.

Development and Splice Lengths of FRP Bars with Splitting Failures (쪼갬파괴에 의한 FRP 보강근의 정착길이와 이음길이)

  • Chun, Sung-Chul;Choi, Dong-Uk
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.4
    • /
    • pp.519-525
    • /
    • 2010
  • Data from beam-based bond tests for FRP bars in the literature were collected and regression analyses were conducted for the data of splitting failure. Average bond strengths obtained from splice tests were found to be lower and more affected by C/$d_b$ values than average bond strengths from anchorage tests, indicating needs of new design equation for the splice length of FRP bars based on the data of splice tests only. In addition, the variation of bond strengths was greater than that of tensile strengths of FRP bars and, therefore, a new safety factor should be involved for the design equation. Five percent fractile coefficients were used to develop the design equations based on the assumption that load and resistance factors for FRP reinforced concrete structures are same to the factors for steel reinforced concrete structures. The proposed design equations give economical and reliable lengths for development and splice of FRP bars. The proposed equation for splice provides shorter lengths than the ACI 440 equation in case of C/$d_b$ of 3.0 or greater. Because FRP bars are expected to be used in slabs and walls exposed to weather with thick cover and large spacing between bars, the proposed equation gives optimal splice lengths.

A Study on the Optimal Design of Reinforced Concrete Frames Using SUMT (SUMT 법(法)을 이용(利用)한 철근(鐵筋)콘크리트 뼈대구조물(構造物)의 최적설계(最適設計)에 관한 연구(研究))

  • Jung, Young Chae;Lee, Qyu Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.27-48
    • /
    • 1984
  • This study is conserned with the optimization of reinforced concrete frames using limit state design theory. Formulations of the optimal design for reinforced concrete frame based on the limit state theory turn out to be the nonlinear programming problems which have to deal with the required steel area, the width and effective height of the beam and column section and the moment reduction factor as the design variables. The objective function is formulated as the total construction cost which considers the costs of steel, concrete and forming for the reinforced concrete frames, and the basic constraints are imposed upon both ultimate and serviciability limit state concepts. Also, the stress blocks assumpted in CP110 and Hognestad et al. theory are applied to analysis an ultimate resistant section force for the ultimate limit state and only the criteria of CP110 are used for serviciability limit state. The optimized technique which is applied to solve the nonlinear programming problems for the optimization of reinforced concrete frames is SUMT utilizing the modified Newton-Raphson method. This algorithm is used to test for the two reinforced concrete frames, and then is compared and analysized with the numerical results of reference(10) to examine its convergence, applicability and stability under the same conditions. The results of this study are discussed about the economy comparision of the optimal values for CP110 and Hognestad et al., and the applicability, stability, convergence and validity of this algorithm used herein through the numerical analyses.

  • PDF

Defect center of $Li^{+}$ ion implanted $Al_2O_3$ ($Li^{+}$ 이온 주입된 $Al_2O_3$의 결함 특성)

  • Kim, Tae-Kyu
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.13-20
    • /
    • 1994
  • The thermoluminescence(TL) glow curves and the optical absorption of $Al_2O_3$ irradiated with ${\gamma}$-ray, electron, and $Li^{+}$ ion followed by electron irradiation have been investigated to determine the relation of TL peak to its defect type. The TL glow curve of $Al_2O_3$ irradiated with ${\gamma}$-ray shows TL peaks at 380 K, 415 K, and 475 K. The UV photobleached TL glow curve of $Al_2O_3$ irradiated with ${\gamma}$-ray shows that the 380 K and 475 K TL peaks completely disappear while the 415 K TL peak still exists. The electron beam induced TL glow curve of $Al_2O_3$ after $Li^{+}$ ion implantation shows that the TL peak at 440 K is enhanced by a factor of 2 over the TL intensity of unimplanted $Al_2O_3$ while the TL peak at 380 K evidently disappears The implanted $Li^{+}$ ions are assumed to form singly charged interstitial cations and then recombine with electron trapped in F centers to produce F+ centers. The 380 K and 475 K TL peaks are proposed to be associated with F center, while the 415 K and 440 K TL peak are connected with F$^{+}$ center.

  • PDF

Spinal Cord Partial Block Technique Using Dynamic MLC (동적 다엽콜리메이터를 이용한 척수의 부분 차폐 기법)

  • 조삼주;이병용;이상욱;안승도;김종훈;권수일;최은경
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.8-14
    • /
    • 2003
  • The spinal cord dose is the one of the limiting factor for the radiation treatment of the head & neck or the thorax region. It is not an easy task to maintain the spinal cord dose below tolerance and to keep the clinically acceptable dose to the PTV in this region. To overcome this problem, the spinal cord partial block technique (PBT) with the dynamic Multi-Leaf Collimator (dMLC) has been developed. This technique is an extension of the conventional treatment planning. In the beginning the beam directions are selected as same as the conventional treatment planning to encompass the PTV, then the partial block are designed to shield the spinal cord. The plan comparisons between the conventional therapy plan and the PTB plan were performed to evaluate the validity of this technique. The mean dose and the dose volume histogram (DVH) were used as the plan comparison indices. A series of quality assurance (QA) was performed to guarantee the reliable treatment. The QA consisted of the film dosimetry for the verification of the dose distribution and the point measurements. The PBT plan generated better results than the conventional treatment plan and it was proved to be useful for the H&N region.

  • PDF

Material Properties of Polymer-Impregnated Concrete and Nonlinear Fracture Analysis of Flexural Members (폴리머 침투콘크리트의 재료특성과 휨부재의 비선형 파괴해석)

  • 변근주;이상민;최홍식;노병철
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.2
    • /
    • pp.97-107
    • /
    • 1994
  • The objective of this study is to develop polymer-impregnated concrete(PIC), which is a newly developed composite material made by impregnating polymer impregnanls into hardened normal concrete, and to develop analytical techniques for its proper applications. Crystalline methyl methacrylate(MMA) is chosen as a monomer of polymer impregnants. The corrlpositions of polymer impregnants and producing processes are developed by analyzing the effects of penetration, polymerization, thermal safety, and strengthening characteristics. On t he basis of experimental results of this study, various strength characteristics and stress strain constitutive relations are formulated in terms of the compressive strength of normal concrete and the polymer loadings, which can be applied for analysis and design of PIC members. In order to provide a model for fracture analysis of flexural members, fracture toughness, fracture energy, critical crack width, and tension softening relations near crack tip are also formulated in terms of member depth, initial notch depth, and the flexural strength of normal concrete. The structural analysis procedure and the finite element computer program developed in the study are applicable to evaluate elastic behavior, ultimate strength, and tension softening behavior of MMA type PIC structural members subject to various loading conditions. The accuracy and effectiveness of the developed computer program is examined by comparing the anal ytical results with the experimental results. Therefore, it is concluded that the developed structural analysis procedure and the finite element computer program are applicable to analysis and design of in-situ and precast PIC structural members.

Behavior of 550MPa 43mm Hooked Bars Embedded in Beam-Column Joints (보-기둥 접합부에 정착된 550 MPa 43 mm 갈고리철근의 거동)

  • Bae, Min-Seo;Chun, Sung-chul;Kim, Mun-Gil
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.611-620
    • /
    • 2016
  • In the construction of nuclear power plants, only 420 MPa reinforcing bars are allowed and, therefore, so many large-diameter bars are placed, which results in steel congestion. Consequently, re-bar works are difficult and the quality of RC structures may be deteriorated. To solve the steel congestion, 550 MPa bars are necessary. Among many items for verifying structural performance of reinforced concrete with 550 MPa bars, the 43 mm hooked bars are examined in this study. All specimens failed by side-face blowout and the side cover explosively spalled at maximum loads. The bar force was initially transferred to the concrete primarily by bond along a straight portion. At the one third of maximum load, the bond reached a peak capacity and began to decline, while the hook bearing component rose rapidly. At failure, most load was resisted by the hook bearing. For confined specimens with hoops, the average value of test-to-prediction ratios by KCI code is 1.45. The modification factor of confining reinforcement which was not allowed for larger than 35 mm bars can be applied to 43 mm hooked bars. For specimens with 70 MPa concrete, the average value of test-to-prediction ratios by KCI code is 1.0 which is less than the values of the other specimens. The effects of concrete compressive strength should be reduced. An equation to predict anchorage capacity of hooked bars was developed from regression analysis including the effects of compressive strength of concrete, embedment length, side cover thickness, and transverse reinforcement index.