• 제목/요약/키워드: Beam Expander

검색결과 22건 처리시간 0.026초

미세 선가공을 위한 레이저 변수 제어 (Control of Laser Parameter for Precision Line Processing)

  • 김영섭;최은서;신용진
    • 한국레이저가공학회지
    • /
    • 제10권1호
    • /
    • pp.11-17
    • /
    • 2007
  • We presented the proper laser processing conditions for the capillary line marking, which could be applied for the fabrication of injection needles. With changing the parameters such as lamp current, duty cycle and beam amplification factor of beam expander, we evaluated the processing performance considering amount of dross, processing efficiency and processed linewidth in the sample. We could carry out the proper line marking at the condition of 70% lamp current, duty cycle of 7-10% and 6-times amplification of beam diameter. To perform efficient line processing, the utilization of duty cycle of 12% at 80% lamp current was also preferred.

  • PDF

고해상도 표면 측정을 위한 회전 프리즘 정합 간섭계 (Rotational Prism Stitching Interferometer for High-resolution Surface Testing)

  • 송인웅;권우성;김학용;이윤우;이종웅;양호순
    • 한국광학회지
    • /
    • 제34권3호
    • /
    • pp.117-123
    • /
    • 2023
  • 반사경의 광학면이 넓어질수록 높은 공간 주파수 형상이 광학계의 성능에 큰 영향을 주므로, 대형 반사경 성능 평가에서 이를 측정할 수 있어야 한다. 따라서 높은 주파수의 형상을 샘플링할 수 있는 고해상도 형상 측정 시스템이 필요하다. 본 연구에서는 반사경의 고해상도 형상 측정을 위한 회전 프리즘 정합 간섭계(rotational prism stitching interferometer, RPSI)라는 새로운 방법을 제안한다. RPSI는 기존에 사용되고 있는 상용 간섭계에 빔 확장 렌즈, 이송 거울, 회전 프리즘 등을 추가하여 구성되었으며, 간섭계를 움직이지 않고 원통 좌표계를 기준으로 전체 구경을 아우르는 부분 구경 형상들을 측정한다. 측정된 부분 구경들은 최소자승법을 이용한 부분 구경 정합법을 이용하여 정합되며, 빔확장 렌즈 배율의 제곱만큼 높은 샘플링 밀도로 전체 구경 형상 정보를 복원 가능하다. 3배율을 가지는 RPSI를 이용하여 직경 40 mm의 구면 반사경 형상을 측정하였고, 간섭계 단독으로 측정한 전체 구경 형상과 비교 검증하였다. 약 1 nm RMS의 근소한 차이로 유사한 형상을 잘 복원할 수 있었으며, 간섭계 단독으로 사용한 형상 측정 결과보다 렌즈의 배율의 제곱배만큼 향상된 샘플링 밀도로 형상 측정이 가능함을 확인하였다.

Effectiveness of low-level laser therapy in facilitating maxillary expansion using bone-borne hyrax expander: A randomized clinical trial

  • Abdelwassie, Sara Hassan;Kaddah, Mohammed Amgad;El-Dakroury, Amr Emad;El-Boghdady, Dalia;Abd El-Ghafour, Mohamed;Seifeldin, Nouran Fouad
    • 대한치과교정학회지
    • /
    • 제52권6호
    • /
    • pp.399-411
    • /
    • 2022
  • Objective: The objective of this randomized clinical trial was to study the skeletal and dental effects of low-level laser therapy (LLLT) along with a miniscrew-assisted expander (Hyrax) after six months of retention. Methods: After sequence generation, concealed allocation, and implementation, 24 female patients were randomly divided (1:1) into two-groups: bone-borne rapid palatal expansion (BBE) without LLLT (n = 12) and BBE with LLLT (n = 12). Eligibility criteria included female patients aged 10-13 years old with bilateral posterior crossbites. Intraoral and extraoral photographs, cone-beam computed tomography images, and digital study models were obtained before expansion and six months after retention. The 7 mm Hyrax appliance was anchored to four palatal mini-screws, which were activated twice daily for 15 days, then locked and kept in place as a retainer. LLLT was performed in the laser group during expansion and retention, according to the guidelines provided. Results: The records of 24 patients were analyzed. According to the post-retention measurements, both groups showed a significant increase in nasal and maxillary widths and total facial height. In the laser group, the Sella-Nasion-Point A and Point A-Nasion-Point B angles and the interpremolar apical distance were significantly increased. Conclusions: Within the limitations of this study, the results suggest that the parameters and protocol of LLLT do not clinically affect the efficiency of BBE in prepubertal and pubertal patients.

마이크로 유체렌즈를 이용한 마이크로 PIV 측정에 관한 실험적 연구 (Experimental Study on Micro PIV Measurement using a Micro Liquid Lens)

  • 정성룡;당중덩;최진호;김규만;박철우
    • 한국가시화정보학회지
    • /
    • 제8권3호
    • /
    • pp.22-28
    • /
    • 2010
  • In the present study, we performed the velocity field measurement in a microchannel using a focal length variable micro liquid lens. The liquid lens is used as a beam expander in a micro-PIV system to acquire the scatter image of the seeded particle. A thin film-type micro liquid lens was made of PDMS material and it was attached on top of the 700-micron-wide working fluid supply channel trench. As a result, the focal length and contact angle of the liquid lens changed with variations in applied pressure.

인체 형상 자료의 전산화에 관한 연구 (A Study on the Computerization of Anthropomorphic Data)

  • 이근부
    • 대한인간공학회지
    • /
    • 제7권2호
    • /
    • pp.23-30
    • /
    • 1988
  • The methods suggested up to now for 3-dimensional anthroponetry require much efforts and costs in measuring and analysing. To solve these problems, we adopt the methods such as Moire Interferometry, Image processing and Computer Vision Technique which are efficient in processing anthropomorphic data. Moire contourgraph was constructed by using Ar-ion laser as a light source (2 Watt power and 5145 A wavelength) and laser beam expander(20X). Image data can be 3-dimensionally reconstructed as the surface patch and geographical relation between faces expressed by mash-point and edges as units. This research is focused on the followings; 1) Development of an economical and reliable measuring method. 2) Design of reproduction methods of 3-dimensional human body data. Therefore, our research makes it possible to study further advanced quantitative analysis of human body.

  • PDF

광조형법에 있어서 조형정도향상을 위한 연구 (The Study on Improvement of Shape Accuracy in Stereolithography)

  • 김준안;백인환
    • 한국정밀공학회지
    • /
    • 제14권5호
    • /
    • pp.15-21
    • /
    • 1997
  • In the stereolithography process, the accuracy of cured shape depends on laser power, scanning speed, scanning pattern, resin characteristics etc. When three-dimensional objects are built, higher laser power gives higher building efficiency. Normally we could control scanning speed and scanning pattern, which affect curing thickness and generate volume of curl in & after building. Olgomer, Monomer and Initiator are major components. Kinds and volume of them decide characteristic of resin. In this paper, we deal with major facts and their characteristics for precision shape building.

  • PDF

에어로졸, 수증기 측정 라만 레이저 레이다 시스템 개발 (Development of Raman Laser Radar System for Aerosol and Water Vapor Measurements)

  • 박찬봉;이영우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.158-161
    • /
    • 2012
  • 대기 중 에어로졸과 수증기 농도를 측정하기 위한 라만방식 레이저 레이다 시스템을 개발하였다. 송신시스템은 Nd:YAG laser 3rd harmonic Generator 및 빔 확대기로 구성되며, 대기 중에 송신되는 파장은 355 nm 이다. 수신시스템은 500 mm 망원경과 3채널 분광기, 광전자증배관 검출기 및 신호처리모듈로 구성되며 최종적으로 처리되는 신호의 파장은 355 nm. 387 nm, 그리고 408 nm 이다. 본 시스템은 대기권의 수증기의 수직 농도분포를 약 100~200 m 의 분해능과 3~4 km의 가 측정거리를 가지고 측정할 수 있다.

  • PDF

위상천이가법에 의한 디지털 홀로그래피 마이크로스코피에 관한 연구 (Digital Holographic microscopy based on phase shifting technique)

  • 박광희;최평석;은재정
    • 융합신호처리학회논문지
    • /
    • 제12권3호
    • /
    • pp.181-187
    • /
    • 2011
  • 본 논문에서는 홀로그램정보의 손실이 없고, CCD 화소면의 최대 활용이 가능한 in-line 형태의 광학계를 구성하고, 보다 향상된 위상 천이법을 토대로 디지털 in-line 홀로그래피 마이크로스코피를 구현하였다 이러한 구성방식으로 디지털 홀로그래피의 최대 문제인 0차 회절 항에 의한 DC잡음과 in-line 홀로그래피에서 나타나는 트윈 이미지가 효율적으로 제거됨을 실험적으로 보였고, 위상 맵핑을 통해 계량적으로 분석하였다. 또한 광학장치 컨트롤과 영상처리가 연동하여 실시간적으로 이루어지므로, 본 논문에서 연구한 DHM 방식은 앞으로 미세분석을 위한 삼차원 현미경법에 많은 응용이 이루어 질것으로 기대된다.

가상격자를 사용한 무아레 무늬 발생기의 구성과 유효초점거리 측정 (The setup of the moiré deflectometry using the virtual grating and the measurement of the effective focal length)

  • 김상기
    • 한국안광학회지
    • /
    • 제5권2호
    • /
    • pp.181-186
    • /
    • 2000
  • 광속의 수렴 발산을 판단하기 위하여 무아레 무늬 발생기(moir$\acute{e}$ deflectometry)를 가상격자를 사용하는 제작하였다. 광원으로 He-Ne laser(3mW)와 무아레 무늬 발생기 광학계 중 광속확대기를 구성하기 위하여 제1렌즈와 제2렌즈의 초점거리는 각각 18 mm, 250 mm인 것을 사용하였다. 가상격자(virtual grating)를 발생시키기 위하여 회절격자(격자상수=$1.6{\mu}m/line$)와 전면 평반사경을 결합하여 무아레 무늬 발생기를 제작하였다. 광학계를 사용하여 시험렌즈의 유효초점거리를 측정하였고, 이 측정값과 유도된 식에 의한 이론값을 비교하였다.

  • PDF

급속 구개확장 후 하악골 폭경변화에 대한 콘빔씨티를 이용한 평가 (Changes in mandibular transversal arch dimensions after rapid maxillary expansion procedure assessed through cone-beam computed tomography)

  • Baysal, Asli;Veli, Ilknur;Ucar, Faruk Izzet;Eruz, Murat;Ozer, Torun;Uysal, Tancan
    • 대한치과교정학회지
    • /
    • 제41권3호
    • /
    • pp.200-210
    • /
    • 2011
  • Objective: This study aimed at evaluating the changes in mandibular arch widths and buccolingual inclinations of mandibular posterior teeth after rapid maxillary expansion (RME). Methods: Baseline and post-expansion cone-beam computed tomographic (CBCT) images of patients who initially had bilateral posterior cross-bite and underwent RME with a banded-type expander were assessed in this study. The patients included 9 boys (mean age: $13.97{\pm}1.17$ years) and 11 girls (mean age: $13.53{\pm}2.12$ years). Images obtained 6 months after retention were available for 10 of these patients. Eighteen angular and 43 linear measurements were performed for the maxilla and mandible. The measurements were performed on frontally clipped images at the following time points; before expansion (T1), after expansion (T2), and after retention (T3). Statistical significance was assessed with paired sample $t$-test at $p$ < 0.05. Results: T1-T2 comparisons showed statistically significant post-RME increases for all measurements; similarly, T2-T1 and T3-T1 comparisons showed statistically significant changes. The maxillary linear and angular measurements showed decreases after expansion, and mandibular linear and angular measurements increased after retention. Conclusion: All mandibular arch widths increased and mandibular posterior teeth were uprighted after RME procedure.