• 제목/요약/키워드: Beam Center

검색결과 2,020건 처리시간 0.029초

Feasibility of a Linear Diode Array Detector for Commissioning of a Radiotherapy Planning System

  • Seung Mo Hong;Uiseob Lee;Sung-woo Kim;Youngmoon Goh;Min-Jae Park;Chiyoung Jeong;Jungwon Kwak;Byungchul Cho
    • 한국의학물리학회지:의학물리
    • /
    • 제34권1호
    • /
    • pp.1-9
    • /
    • 2023
  • Purpose: Although ionization chambers are widely used to measure beam commissioning data, point-by-point measurements of all the profiles with various field size and depths are time-consuming tasks. As an alternative, we investigated the feasibility of a linear diode array for commissioning a treatment planning system. Methods: The beam data of a Varian TrueBeam® radiotherapy system at 6 and 10 MV with/without a flattening filter were measured for commissioning of an Eclipse Analytical Anisotropic Algorithm (AAA) ver.15.6. All of the necessary beam data were measured using an IBA CC13 ionization chamber and validated against Varian "Golden Beam" data. After validation, the measured CC13 profiles were used for commissioning the Eclipse AAA (AAACC13). In addition, an IBA LDA-99SC linear diode array detector was used to measure all of the beam profiles and for commissioning a separate model (AAALDA99). Finally, the AAACC13 and AAALDA99 dose calculations for each of the 10 clinical plans were compared. Results: The agreement of the CC13 profiles with the Varian Golden Beam data was confirmed within 1% except in the penumbral region, where ≤2% of a discrepancy related to machine-specific jaw calibration was observed. Since the volume was larger for the CC13 chamber than for the LDA-99SC chamber, the penumbra widths were larger in the CC13 profiles, resulting in ≤5% differences. However, after beam modeling, the penumbral widths agreed within 0.1 mm. Finally the AAALDA99 and AAACC13 dose distributions agreed within 1% for all voxels inside the body for the 10 clinical plans. Conclusions: In conclusion, the LDA-99SC diode array detector was found to be accurate and efficient for measuring photon beam profiles to commission treatment planning systems.

초음파진단기의 Beam Simulation (Beam Simulation in Diagnostic Ultrasound)

  • 배무호;이승우
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.289-292
    • /
    • 1996
  • The 2-way beam simulation for the diagnostic ultrasound is performed with simplified computation by approximating the transducer and the system. The results show that the simulation program can be used as a good system design tool.

  • PDF

Plastic Deformation Capacity of Steel Beam-to-Column Connection under Long-duration Earthquake

  • Yamada, Satoshi;Jiao, Yu;Narihara, Hiroyuki;Yasuda, Satoshi;Hasegawa, Takashi
    • 국제초고층학회논문집
    • /
    • 제3권3호
    • /
    • pp.231-241
    • /
    • 2014
  • Ductile fracture is one of the most common failure modes of steel beam-to-column connections in moment resisting frames. Most proposed evaluation methods of the plastic deformation capacity of a beam until ductile fracture are based on steel beam tests, where the material's yield strength/ratio, the beam's moment gradient, and loading history are the most important parameters. It is impossible and unpractical to cover all these parameters in real tests. Therefore, a new attempt to evaluate a beam's plastic deformation capacity through analysis is introduced in this paper. Another important issue is about the loading histories. Recent years, the effect on the structural component under long-duration ground motion has drawn great attentions. Steel beams tends to experience a large number of loading cycles with small amplitudes during long-duration earthquakes. However, current research often focuses on the beam's behavior under standard incremental loading protocols recommended by respective countries. In this paper, the plastic deformation capacity of steel beams subjected to long duration ground motions was evaluated through analytical methodology.

The influence of Ne-Xe gas mixture ratio on vacuum Ultraviolet and infrared line in AC-PDP

  • Oh, Phil-Y.;Cho, I.R.;Jung, Y.;Park, K.D.;Ahn, J.C.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.743-747
    • /
    • 2003
  • The improvement of luminance and luminous efficiency is the one of the most important part in AC-PDPs. To achieve high luminance and luminous efficiency, high VUV emission efficiency is needed. We measured the emission spectra of vacuum ultraviolet(VUV) and infrared(IR) rays in surface discharge AC-PDP with Ne-Xe mixture gas. The influence of Ne-Xe gas-mixture ratio on resonance state $Xe^{\ast}(3P_{1})$ and exited state $Xe^{\ast}(3P_{2})$ has been investigated. It is found that the intensity of VUV 147nm emission is proportional to that of the IR 828 nm emission, and the VUV 173nm emission is roughly proportional to that of the IR 823nm emission. The electron temperature and plasma density have been experimentally measured from the center of sustaining electrode gap by a micro Langmuir probe in AC-PDPs. The plasma density from the center of sustaining electrode gap are shown to be maximum value of $9{\times}10^{11}cm^{-3}$, where the electron temperature is about 1.6 eV in this experiment

  • PDF

The electronic structure of the ion-beam-mixed Pt-Cu alloys by XPS and XANES

  • Lim, K.Y.;Lee, Y.S.;Chung, Y.D.;Lee, K.M.;Jeon, Y.;Whang, C.N.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1998년도 제14회 학술발표회 논문개요집
    • /
    • pp.133-133
    • /
    • 1998
  • In the thin film alloy formation of the transition metals ion-beam-mixing technique forms a metastable structure which cannot be found in the arc-melted metal alloys. Sppecifically it is well known that the studies about the electronic structure of ion-beam-mixed alloys pprovide the useful information in understanding the metastable structures in the metal alloy. We studied the electronic change in the ion-beam-mixed ppt-Ct alloys by XppS and XANES. These analysis tools pprovide us information about the charge transfer in the valence band of intermetallic bonding. The multi-layered films were depposited on the SiO2 substrate by the sequential electron beam evapporation at a ppressure of less than 5$\times$10-7 Torr. These compprise of 4 ppairs of ppt and Cu layers where thicknesses of each layer were varied in order to change the alloy compposition. Ion-beam-mixing pprocess was carried out with 80 keV Ae+ ions with a dose of $1.5\times$ 1016 Ar+/cm2 at room tempperature. The core and valence level energy shift in these system were investigated by x-ray pphotoelectron sppectroscoppy(XppS) pphotoelectrons were excited by monochromatized Al K a(1486.6 eV) The ppass energy of the hemisppherical analyzer was 23.5 eV. Core-level binding energies were calibrated with the Fermi level edge. ppt L3-edge and Cu K-edge XANES sppectra were measured with the flourescence mode detector at the 3C1 beam line of the ppLS (ppohang light source). By using the change of White line(WL) area of the each metal sites and the core level shift we can obtain the information about the electrons pparticippating in the intermetallic bonding of the ion-beam-mixed alloys.

  • PDF

굽힘 강도 향상을 위한 프레스 도어 임팩트 빔의 단면 설계 (The Section Design of Press Door Impact Beam for Improving Bending Strength)

  • 조경래;강성종
    • 한국자동차공학회논문집
    • /
    • 제25권1호
    • /
    • pp.74-81
    • /
    • 2017
  • The door impact beam of the side-impacted vehicle plays a key role in securing occupant safety by preventing intrusion from the impacting vehicle. Despite the low production cost, the press door impact beam has been adopted sparingly because of the strength inferiority. In this study, the design technologies of the press beam aimed at improving bending strength were investigated. First, the effect of the section shape and size was examined. Next, thickness and material strength were increased. Also, the TRB beam application was simulated by varying combined thickness. Some TRB beams with reduced weight exhibited bending strength over the strength of the pipe beam. Then, the beam with a closed center section also showed remarkably enhanced maximum bending strength.

Performance prediction of gamma electron vertex imaging (GEVI) system for interfractional range shift detection in spot scanning proton therapy

  • Kim, Sung Hun;Jeong, Jong Hwi;Ku, Youngmo;Jung, Jaerin;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2213-2220
    • /
    • 2022
  • The maximum dose delivery at the end of the beam range provides the main advantage of using proton therapy. The range of the proton beam, however, is subject to uncertainties, which limit the clinical benefits of proton therapy and, therefore, accurate in vivo verification of the beam range is desirable. For the beam range verification in spot scanning proton therapy, a prompt gamma detection system, called as gamma electron vertex imaging (GEVI) system, is under development and, in the present study, the performance of the GEVI system in spot scanning proton therapy was predicted with Geant4 Monte Carlo simulations in terms of shift detection sensitivity, accuracy and precision. The simulation results indicated that the GEVI system can detect the interfractional range shifts down to 1 mm shift for the cases considered in the present study. The results also showed that both the evaluated accuracy and precision were less than 1-2 mm, except for the scenarios where we consider all spots in the energy layer for a local shifting. It was very encouraging results that the accuracy and precision satisfied the smallest distal safety margin of the investigated beam energy (i.e., 4.88 mm for 134.9 MeV).

양성자치료용 보상체의 영상기반 정도 관리 기반 프로그램 개발 (Image Based Quality Assurance of Range Compensator for Proton Beam Therapy)

  • 김진성;윤명근;김동욱;임영경;곽정원;박소아;신동호;신정욱;이세병;박성용;조관호
    • 한국의학물리학회지:의학물리
    • /
    • 제19권1호
    • /
    • pp.35-41
    • /
    • 2008
  • 양성자치료는 양성자의 물리적 특성으로 인해 인체 내의 특정범위에 모든 에너지를 전달하고 감쇠되어 타겟조직 뒤에 존재하는 정상조직에는 방사선이 조사되지 않는 큰 장점을 가진 치료법이다. 이 방법은 인체 내의 암 조직을 타겟으로 했을 때, 빔 방향에서의 타겟의 2차원적인 모양은 황동으로 제작된 블럭을 통해 정상조직에 들어가는 방사선을 차폐하고 마진을 주어서 GTV (eross Tumor Volume)에 90% 이상의 선량이 전달되도록 조절한다. 그리고, 양성자 빔의 날줄방향 (longitudinal)에서의 타겟의 3차원적인 모양을 고려하여 PMMA로 이루어진 보상체(compensator)를 밀링머신으로 조각하여 타겟에 방사선이 정확하게 분포되도록 한다. 이러한 보상체의 정확한 정도 관리를 위해 현재 사용되는 수동적인 방법을 보완하여 X선 영상으로 해당하는 보상체의 영상을 획득하여 이 영상을 기반으로 정도관리를 할 수 있는 방법을 제안하였고, 제안한 방법으로 보상체의 각각의 깎여진 평면의 모양과 두께를 정성적으로 비교 및 평가할 수 있었으며 두 영상의 차이가 80% 이상 맞는 것으로 확인되었다. 이를 바탕으로 영상을 이용한 정도관리 프로그램을 보완하여 추후 실제 양성자치료 정도관리에 사용될 예정이다.

  • PDF

Microscale BTS sculptured by electron beam

  • Choi, Haneul;Jeong, Young Woo;Chang, Hye Jung
    • Applied Microscopy
    • /
    • 제49권
    • /
    • pp.4.1-4.2
    • /
    • 2019
  • We applied the advanced bitmap-assisted patterning function of focused ion beam to fabricate microscale sculpture of the 'BangTanSoNyeonDan' known as BTS members, the world-wide famous K-pop boyband. With the help of an electron microscope, you can carve your idols on your accessories at micro scale. Fun applications of electron microscopes are not limited to science.

Influence of sintering temperature of MgO pellet on the electro-optical characteristics of alternating current plasma display panel (AC-PDP)

  • Hong, Sung-Hee;Son, Chang-Gil;Jung, Seok;Kim, Jung-Seok;Paik, Jong-Hoo;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.400-403
    • /
    • 2008
  • We have investigated the electro-optical characteristics of AC-PDP with different MgO protective layers, which have been deposited by electron beam evaporation from various sintered pellets with different temperatures. We have measured the secondary electron emission coefficient ($\gamma$) by using the Gamma Focused Ion Beam ($\gamma$-FIB) system, the static margin, and the address delay time. Also, we have investigated photoluminescence (PL) characteristics for understanding the energy levels of MgO pellets and protective layers.

  • PDF