• Title/Summary/Keyword: Battery housing

Search Result 24, Processing Time 0.022 seconds

A Study on Modeling of Leakage Current in ESS Using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 ESS의 누설전류 모델링에 관한 연구)

  • Kim, Ji-Myung;Tae, Dong-Hyun;Lee, Il-Moo;Lim, Geon-Pyo;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.810-818
    • /
    • 2021
  • A leakage current of ESS is classified mainly by the occurrence from a PCS(Power Conditioning System) section and an unbalanced grid current. The reason for the leakage current from the PCS section is a voltage change by IGBT (Insulated Gate Bipolar Transistor) switching and stray capacitance between the IGBT and heatsink. The leakage current caused by the grid unbalanced current flows to the ESS through the neutral line of grid-connected transformer for the ESS with a three limb iron type of Yg-wire connection. This paper proposes a mechanism for the occurrence of leakage current caused by stray capacitance, which is calculated using the heatsink formula, from the aspect of the PCS section and grid unbalance current. Based on the proposed mechanisms, this study presents the modeling of the leakage current occurrence using PSCAD/EMTDC S/W and evaluates the characteristics of leakage currents from the PCS section and grid unbalanced current. From the simulation result, the leakage current has a large influence on the battery side by confirming that the leakage current from the PCS is increased from 7[mA] to 34[mA], and the leakage current from an unbalanced load to battery housing is increased from 3.96[mA] to 10.76[mA] according to the resistance of the housings and the magnitude of the ground resistance.

Thermal and Electrical Energy Mix Optimization(EMO) Method for Real Large-scaled Residential Town Plan

  • Kang, Cha-Nyeong;Cho, Soo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.513-520
    • /
    • 2018
  • Since Paris Climate Change Conference in 2015, many policies to reduce the emission of greenhouse gas have been accelerating, which are mainly related to renewable energy resources and micro-grid. Presently, the technology development and demonstration projects are mostly focused on diversifying the power resources by adding wind turbine, photo-voltaic and battery storage system in the island-type small micro-grid. It is expected that the large-scaled micro-grid projects based on the regional district and town/complex city, e.g. the block type micro-grid project in Daegu national industrial complex will proceed in the near future. In this case, the economic cost or the carbon emission can be optimized by the efficient operation of energy mix and the appropriate construction of electric and heat supplying facilities such as cogeneration, renewable energy resources, BESS, thermal storage and the existing heat and electricity supplying networks. However, when planning a large residential town or city, the concrete plan of the energy infrastructure has not been established until the construction plan stage and provided by the individual energy suppliers of water, heat, electricity and gas. So, it is difficult to build the efficient energy portfolio considering the characteristics of town or city. This paper introduces an energy mix optimization(EMO) method to determine the optimal capacity of thermal and electric resources which can be applied in the design stage of the real large-scaled residential town or city, and examines the feasibility of the proposed method by applying the real heat and electricity demand data of large-scale residential towns with thousands of households and by comparing the result of HOMER simulation developed by National Renewable Energy Laboratory(NREL).

An Experiment Study on Electric Vehicle Fire and Fire Response Procedures (전기차 화재 실험 및 대응방안에 관한 연구)

  • Ki-Hun Nam;Jun-Sik Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.1
    • /
    • pp.63-70
    • /
    • 2024
  • Lithium-ion batteries (LIB) are widely used in various sectors, such as transportation (e.g., electric vehicles (EV)) and energy (e.g., energy storage facilities) due to their high energy density, broad operating temperature (-20 ℃ ~ 60 ℃), and high capacities. LIBs are powerful but fragile on external factors, including pressure, physical damage, overheating, and overcharging, that cause thermal runaway causing fires and explosions. During a LIB fire, a large amount of oxygen is generated from the decomposition of ionogenic materials. A water fire extinguisher that helps with cooling and suffocating must be essentially required at the same time. In fact, however, it is difficult to suppress LIB fires in the case of EVs because a LIB is installed with a battery pack housing that interrupts direct extinguishing by water. Thus, this study aims to investigate effective fire extinguishing measurements for LIB fires by using an EV. Relevant documents, including research articles and reports, were reviewed to identify effective ways of LIBs fire extinguishing. A real-scale fire experiment generating thermal runaway was carried out to figure out the combustion characteristics of EVs. This study revealed that the most effective fire extinguishing measurements for LIB fires are applying fire blankets and water tanks. However, there is still a lack of adequate regulation and guidelines for LIB fire extinguishment. Taking this into account, developing functional fire extinguishment measurements and available regulatory instruments is an urgent issue to secure the safety of firefighters and citizens.

Lead Pollution and Lead Poisoning among Children in China

  • Zheng, Yuxin
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.24-25
    • /
    • 2003
  • Lead is ubiquitous in the human environment as a result of industrialization. China's rapid industrialization and traffic growth have increased the potential for lead emissions. Lead poisoning in children is one of the most common public health problems today, and it is entirely preventable. Children are more vulnerable to lead pollution and lead in their bodies can affect their nervous, circulatory, and digestive systems. Children are exposed to lead from different sources (such as paint, gasoline, and solder) and through different pathways (such as air, food, water, dust, and soil). Although all children are exposed to some lead from food, air, dust, and soil, some children are exposed to high dose sources of lead. Significant sources of lead for China's children include industrial emissions (often close to housing and schools), leaded gasoline, and occupational exposure that occurs when parents wear lead-contaminated clothing home from work, burning of coal for home heat and cooking, contaminated food, and some traditional medicines. To assess the blood lead level in children in China, a large-scale study was conducted in 19 cities among 9 provinces during 1997 to 2000. There were 6502 children, aged 3-5 years, were recruited in the study The result indicates that the mean blood lead level was 8.83ug/dl 3-5 year old living in city area. The mean blood lead level of boys was higher than that of girls (9.1l ug/dl vs 8.73ug/dl). Almost 30 percent childrens blood lead level exceeded 10ug/dl. The average blood lead level was higher than that of in 1985 (8.83ug/dl vs 8.lug/dl). An epidemiological study was carried on the children living around the cottage industries recycling the lead from battery. Nine hundreds fifty nine children, aged 5-12 years, living in lead polluted villages where the lead smelters located near the residential area and 207 control children live in unpolluted area were recruited in the study. The lead levels in air, soil, drinking water and crops were measured. The blood lead and ZnPP level were tested for all subjects. The results show that the local environment was polluted. The lead levels both in the air and crops were much higher than that of in control area. In the polluted area, the average blood level was 49.6ug/dl (rang 19.5-89.3ug/dl). Whereas, in the unpolluted area, the average blood level was 12.4ug/dl (rang 4.6-24.8ug/dl). This study indicates that in some countryside area, some cottage industries induce seriously lead pollution and cause children health problem. For the introducing of unleaded gasoline in some large cities, such as Beijing and Shanghai, the blood lead level showed a declined trend since 1997. By 2000, the use of leaded gasoline in motor vehicles has been prohibited in China. The most recent data available show that levels of lead in blood among children in Shanghai decreased from 8.3ug/dl in 1997 to 7.6ug/dl in 1999. The prevalence rate of children lead poisoning (blood lead >10ug/dl) was also decreased from 37.8% to 24.8%. In children living in downtown area, the blood lead level reduced dramatically. To explore the relationship between gene polymorphisms and individual susceptibility of lead poisoning, a molecular epidemiological study was conducted among children living in lead polluted environment. The result showed that the subjects with ALAD2 allele has higher ZPP level, and the subjects with VDR B allele has larger head circumference than only with b allele. In the present study, we demonstrated that ALAD genotypes modify lead effects on heme metabolism and VDR gene variants influence the skull development in highly exposed children. The polymorphism of ALAD and VDR genes might be the molecular inherited factor modifying the susceptibility of lead poisoning. Recently, Chinese government pays more attention to lead pollution and lead poisoning in children problem. The leaded gasoline was prohibited used in motor vehicles since 2000. The government has decided to have a clampdown on the high-polluted lead smelters for recycling the lead from battery in countryside. It is hopeful that the risk of lead poisoning in children will be decreased in the further

  • PDF