• 제목/요약/키워드: Battery Diagnosis

검색결과 58건 처리시간 0.03초

배터리 수명진단을 위한 LabView 기반 임피던스 측정 시스템 (Battery Diagnosis by using Impedance Measurement System based on Labview)

  • 김선혁;이형민;권구영;조우진;박인준;최우준;채영철;신용준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.605-606
    • /
    • 2015
  • 본 논문에서는 배터리의 상태 진단을 위한 임피던스 측정시스템을 제시한다. Labview를 이용한 임피던스 측정 시스템은 저가에서 구성할 수 있고, 변화되는 임피던스를 확인이 가능해 수명을 진단하는 지표로 이용 가능하다. 제시된 임피던스 측정 방법은 용량에 상관없이 측정이 가능하고, 기존의 장치보다 측정과 값을 계산하기가 간단하다. 또한, 고가의 장비를 이용하지 않고도, Labview와 DAQ를 이용하여 정확성 높은 결과를 구할 수 있다.

  • PDF

한국형 고속전철 보조전원장치 고장진단과 성능평가 (Fault Diagnosis and Performance Evaluation of Auxiliary Block for Korean High-Speed Train)

  • 한영재;김기환;김석원;김종영;김현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1449-1454
    • /
    • 2004
  • For the research, we developed the hardware and software of the measurement system for on-line test and evaluation. The software controls the hardware of the measurement data and acts as a interface between users and the system hardware. In this paper, we studied performances of the auxiliary block for high-speed railway vehicle. In order to performance these works, the conversion system was developed. Using this system, we obtained the important results, such as voltage values for the battery charger and auxiliary block. Also, we diagnosed the faults and performed the evaluation for auxiliary block using the measurement system and data.

  • PDF

성대 Bowing의 술전.후 음성기능 (Vocal Function After Surgical Correction of the Bowing Vocal Cords)

  • 정광윤;최종욱;한동수
    • 대한후두음성언어의학회지
    • /
    • 제6권1호
    • /
    • pp.9-15
    • /
    • 1995
  • Bowing of the vocal cords may be due to aging. atrophy. bilateral superior laryngeal nerve paralysis. injudicious vocal cord surgery, of an idiopathic cause. The bowing usually produces a dysphonia characterized by breathiness due to air escape : however, it can produce aphonia. This report reviews vocal function after surgical correction of bowing of the vocal cords for diagnosis and management. The vocal function of 13 patients with sulcus vocalis and 12 patients with vocal cord atrophy was evaluated with the use of a test battery of multidimensional evaluation items. The voice was improved postoperatively in most patients. The voice improvement was reflected objectively in maximum phonation time, mean air flow rate during phonation, stroboscopic findings. sound pressure level range and fundamental frequency range of phonation, and results of acoustic analyses of tape-recorded voice. The vocal function after surgical correction of the sulcus vocalis and vocal cord atrophy was improved postoperatively in most patient, but the results were not satisfactory.

  • PDF

LabVIEW를 이용한 자동차 발전기 전압 계측시스템 (Measurement System for Vehicle Electric Power using LabVIEW)

  • 소순선;양수진;이성철
    • 한국산학기술학회논문지
    • /
    • 제15권10호
    • /
    • pp.5899-5905
    • /
    • 2014
  • 본 차량에 장착되는 전자장비의 증가로 인해 교류발전기와 배터리를 이용하여 전기에너지를 공급하고 있으며, 자동차 교류발전기의 수명단축은 교류발전기를 구성하고 있는 부속품들 중에 수명이 한정적이거나, 어떠한 조건에서 사용되느냐에 따라 수명에 영향을 끼치게 된다. 이러한 수명단축의 원인들을 파악하기 위해서는 교류발전기의 전압을 측정하여 분석하는 시스템이 필요하다. 따라서 본 연구에서는 자동차 교류발전기의 수명과 성능을 유지하기 위한 점검 및 정비에 필요한 정밀한 계측 시스템을 개발하였다. PC기반의 모니터링 시스템과 측정데이터를 저장할 수 있는 시스템을 설계하고, LabVIEW SW를 이용하여 계측 시스템을 구동하기 위한 프로그램을 개발하였다. 차동 OP-AMP회로를 이용하여 교류발전기의 발전전압, 여자전압, 램프전압, 배터리 전압, 크랭크 각 센서에 의한 엔진 회전수를 NI DAQ를 통하여 전압을 측정하고 LabVIEW 프로그램을 이용하여 측정데이터를 분석하였다. 기존에 개별적으로 이루어졌던 측정을 5개 채널까지 복합적이고 이동성이 용이한 측정이 가능하였고, 실시간으로 모니터링하며 분석하기 때문에 이상동작 유무 및 고장상태를 예측하기 위한 자료로 활용될 수 있을 것으로 기대된다.

입력전원의 변화에 따른 X선 기기의 특성평가 (Characteristic of X-ray Equipment according to the Input Power Condition)

  • 김영표;김태곤;천민우;박용필
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 추계학술대회
    • /
    • pp.773-775
    • /
    • 2010
  • 의료용 X-선 고전압발생장치는 작동 시 높은 용량의 입력전원이 필요하며, 만약 전원환경이 적합하지 않을 경우 X-선 고전압발생장치를 사용하지 못하거나 불안정한 작동으로 인해 원활한 작동이 불가능해 진다. 전원환경에 따라 제품이 불안정 할 경우 환자 진료에 지장이 생길 수 있는 것을 감안하여 상용전원을 사용하지 않고 의료용 X-선 고전압발생장치를 작동 할 수 있는 전원장치를 배터리를 활용하도록 하였다. 전원회로를 설계한 후 시제품을 제작하여 본 논문에 제시된 방법에 따라 상용전원과 배터리 전원을 각각 비교하여 의료용 X-선 고전압발생장치가 입력전원방식에 따라 어떤 특성과 효율을 가지고 있는지 확인하였다.

  • PDF

통상적 혈액화학 결과에서 전반적 퇴화 척도의 영향성 (Influences of the Global Deterioration Scale according to Routine Blood Chemistry Results)

  • 김선규;박창은
    • 대한임상검사과학회지
    • /
    • 제51권3호
    • /
    • pp.351-359
    • /
    • 2019
  • 신경인지검사는 외래에서 전반적인 인지기능 정도를 평가하는 MMSE (Mini-Mental State Examination)가 가장 보편적이지만, 최근에는 SNSB II (Seoul Neuropsychological Screening Battery II)를 통해 심층적으로 진단에 활용된다. 2017년부터 2018년까지 경기도 남부지역 일개 의료원에 내원한 보건소에서 정밀검사 의뢰된 노인층 120명의 통상적인 신경인지검사 결과와 혈액검사 항목을 후향적으로 조사하였다. GDS의 하위 영역의 평가에서는 시공간 능력이 높게 나타났다. 그리고 혈액 전해질 중 Na이 GDS 수준이 증가함에 따라 통계적으로 유의한 감소를 보였다. 또한 GDS 수준에 따른 집중력, 언어 시공간능력, 기억력, 전두엽 실행 기능이 통계적으로 유의한 감소를 보였다(P<0.001). ALT와 크레아티닌이 정상군과 비정상군에서 전두엽 실행 기능 영역이 통계적으로 유의한 차이를 보였다(P<0.001). 또한 GDS와 ALT는 음의 상관성을 보였다(P<0.01). 결론적으로 본 연구를 통해 선별 및 진단에 유의한 검사 항목을 개발하는데 기초정보를 제공하고, 통상적인 혈액화학검사가 인지장애 환자의 진단 및 진행에 대한 기본 정보를 제공할 것으로 사료된다.

사회심리적 스트레스 및 작업특성 요인이 직업성요통에 미치는 영향 (The Effects of Psychosocial Stress and Job Characteristics on Low Back Injury)

  • 허국강;박동현
    • 대한인간공학회지
    • /
    • 제19권2호
    • /
    • pp.15-31
    • /
    • 2000
  • The aim was to evaluate the prevailing ergonomic and psychosocial conditions regarding low back injury in an automobile assembly system. This study consisted of two parts. In the first part of the study, analytic biomechanical model and NIOSH guidelines were applied to evaluate risk levels of low back injury for automobile assembly jobs. Total of 246 workers were analysed. There were 20 jobs having greater back compressive forces than 300kg at L5/S1. Also, there were 44 jobs over Action Limit with respect to 1981 NIOSH guidelines. This might in part be explained by the ergonomic conditions of the company analysed generally being good, with a relatively low duration of 'combined' extreme work posture. The relationship between psychosocial factors and low back injury was examined in the second part of the study. It has recently been recognized that overall reaction to working conditions was influenced by a range of factors, some of which were physical and some psychosocial. The psychosocial environment surrounding the work place may contribute to the perception of risk and eventual ill-health. A battery of questionnaires concerning the psychosocial stress based on PWI(Psychosocial Well-being Index) and musculoskeletal pain symptoms at low back was completed by 246 workers at the same plant. Results showed that 207 out 246 workers experienced the symptoms and 27 workers were diagnosed as patients. Two groups(low stressed, high stressed) based on PWI score had no significant relationships with both symptoms and results of diagnosis. However, sensitivities for symptoms and diagnosis by PWI were 91.3% and 92.6% respectively. Finally, relationships between physical work load and psychosocial stress were analysed. Specifically, some postural factors {vertical deviation angle of forearm, horizontal deviation angle of upperarm, vertical deviation angle of thigh, etc) were highly correlated with psychosocial stress. The results illustrated that PWI scores were associated with some physical workloads. However, psychosocial stress levels couldn't be well related with the pain symptom as well as the actual incidence of low back injury since pain or discomfort regarding low back injury were more complex than that of other musculoskeletal disorders.

  • PDF

SVDD 기법을 이용한 하이브리드 전기자동차의 고장검출 알고리즘 (Fault Detection Algorithm of Hybrid electric vehicle using SVDD)

  • 나상건;전종현;한인재;허훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.224-229
    • /
    • 2011
  • In this paper, in order to improve safety of hybrid electric vehicle a fault detection algorithm is introduced. The proposed algorithm uses SVDD techniques. Two methods for learning a lot of data are used in this technique. One method is to learn the data incrementally. Another method is to remove the data that does not affect the next learning. Using lines connecting support vectors selection of removing data is made. Using this method, lot of computation time and storage can be saved while learning many data. A battery data of commercial hybrid electrical vehicle is used in this study. In the study fault boundary via SVDD is described and relevant algorithm for virtual fault data is verified. It takes some time to generate fault boundary, nevertheless once the boundary is given, fault diagnosis can be conducted in real time basis.

  • PDF

Optimized Charging in Large-Scale Deployed WSNs with Mobile Charger

  • Qin, Zhenquan;Lu, Bingxian;Zhu, Ming;Sun, Liang;Shu, Lei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권12호
    • /
    • pp.5307-5327
    • /
    • 2016
  • Restricted by finite battery energy, traditional wireless sensor networks (WSNs) can only maintain for a limited period of time, resulting in serious performance bottleneck in long-term deployment of WSN. Fortunately, the advancement in the wireless energy transfer technology provides a potential to free WSNs from limited energy supply and remain perpetual operational. A mobile charger called wireless charging vehicle (WCV) is employed to periodically charge each sensor node and keep its energy level above the minimum threshold. Aiming at maximizing the ratio of the WCV's vocation time over the cycle time as well as guaranteeing the perpetual operation of networks, we propose a feasible and optimal solution to this issue within the context of a real-time large-scale deployed WSN. First, we develop two different types of charging cycles: initialization cycles and renewable cycles and give relevant algorithms to construct these two cycles for each sensor node. We then formulate the optimization problem into an optimal construction algorithm and prove its correctness through theoretical analysis. Finally, we conduct extensive simulations to demonstrate the effectiveness of our proposed algorithms.

u-Health 서비스를 위한 스마트폰용 스펙트럼 측정 시스템 개발 (Development of Smart Phone Application With Spectrometer for u-Health Service)

  • 김동수;이서준;이태로
    • 디지털융복합연구
    • /
    • 제11권7호
    • /
    • pp.261-269
    • /
    • 2013
  • u-Health는 최근 기술이며 의료 진단과 건강관리를 위한 새로운 방법론이다. 그러나 이를 실현하려면 몇 가지 기술적 장벽들(이동성, 소형화, 배터리 수명 문제 등)을 넘어서야 한다. 본 논문에서는 u-Health 서비스에 적합한 스마트폰용 스펙트럼 측정 시스템을 개발하였다. 실험 결과 기존 솔루션에 비해 무선이면서 크기가 매우 작지만 성능 면(재현성 비교실험에서 Spectrum, Calibration Curve, Prediction)에서 거의 일치한다는 것을 확인하였다. 따라서 개발된 솔루션은 u-Health 분야에서 널리 활용되어질 것으로 기대된다.