• Title/Summary/Keyword: Basic Metals

Search Result 274, Processing Time 0.047 seconds

Evaluation of Basic Unit for Non-point Pollutants in Runoff of West Coast Highway - Maesong Area (서해안 고속도로 매송지역 비점오염원 원단위 산정 연구)

  • Park, Seyong;Mo, Kyung;Kim, Leehyung;Kang, Heeman;Kim, Moonil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.8
    • /
    • pp.33-40
    • /
    • 2010
  • In this study, evaluation of basic unit of non-point pollutant, which is fundamental evaluation of non-point loading, was conducted using both road point and angle of intersection point in Maesong area, West coast highway by utilizing Event Mean Concentrations(EMC). Concentration of pollutants except heavy metals at these two points rapidly decreased in 30 minutes after start of runoff. According to the results of EMC, for both sampling points, it was determined that the concentrations of TSS(Total Suspended Solid), $BOD_5$(Biological Oxygen Demand), and DOC(Dissolved Organic Carbon) were higher than those of wastewater effluent standard in Korea, however, the concentrations of T-N(Total Nitrogen) and T-P(Total Phosphorus) were lower than those of the standard. In terms of heavy metals, Fe, Pb, and Zn showed higher concentrations than others. When compared with the units established by the Ministry of Environment in Korea, the basic units of $BOD_5$ and T-N in this study were lower. On the other hand, when compared with foreign units, Cu, Pb, and Zn showed approximately 10 times higher concentrations. It was estimated that a long term monitoring should be conducted for obtaining additional data and more reliable basic units for the non-point pollutnats based on the results from this study.

Factors Affecting the Magnitude of the Metal-Insulator Transition Temperature in AMo4O6 (A=K, Sn)

  • Jung, Dong-Woon;Choi, Kwang-Sik;Kim, Sung-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.7
    • /
    • pp.959-964
    • /
    • 2004
  • A low-dimensional metal frequently exhibits a metal-insulator transition through a charge-density-wave (CDW) or a spin-density-wave (SDW) which accompany it's structural changes. The transition temperature is thought to be determined by the amount of energy produced during the transition process and the softness of the original structure. $AMo_4O_6$ (A=K, Sn) are known to be quasi-one dimensional metals which exhibit metalinsulator transitions. The difference of the transition temperatures between $KMo_4O_6$ and $SnMo_4O_6$ (A=K, Sn) is examined by investigating their electronic and structural properties. Fermi surface nesting area and the lattice softness are the governing factors to determine the metal-insulator transition temperature in $AMo_4O_6$ compounds.

Latest analysis methods for the next generation of nano devices using multi-disciplinary in situ Nano-Surface Analytical System (표면분석 장비를 활용한 차세대 나노소자 물성분석)

  • Lee, Jouhahn
    • Vacuum Magazine
    • /
    • v.1 no.1
    • /
    • pp.21-26
    • /
    • 2014
  • The new materials such as graphene and other nano scale structured materials are attracting great attention due to its expandability for the future electronic devices. In this presentation, a variety of analysis techniques will be introduced for the latest new material applications such as graphene and organic materials with number of metals. The basic properties of next generation device should be carefully analyzed without being exposed to ambient surrounding since the physical and chemical properties of new material or interface states are easily and drastically changed by ambient condition. With the combination of the fabrication process and precise analysis instruments, it is expected to set the facilities supporting the nanotechnology industry and other research groups. This system will give strong support nanotechnology and other complex science with qualified data and information on basic knowledge on the new-forthcoming materials for the future.

The Quality Characteristics of Artificial Aggregates Using Bottom ash from Industrial Waste Incinerator (산업쓰레기 소각재를 이용한 인공골재의 품질특성)

  • 김재신;고대형;문경주;백명종;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.257-262
    • /
    • 2000
  • The purpose of this study is grasping quality aggregate using Bottom Ash of Industrial Waste Incinerator, and is evaluating possibility of application as construction materials. Cement and Fly ash is used with binder of aggregates using bottom ash. It is tested for basic property and strength of artificial aggregates, and the results are compared with crushed stone and elution tests is done for environmental safety. In the results of tests, it is confirmed that basic property and strength are lowe than crushed stone but the aggregates have possibility of application as artificial lightweight aggregates. When it is manufactured with aggregates, it is sage environmentally because of protecting elution of harmful heavy metals.

  • PDF

Biosorption Model and Factors for Removing Lead to Aureobasdium pullulans being Imperfect Fungus (불완전 균류 Aureobasdium pullulans으로 납을 제거하기 위한 인자들과 흡착모델)

  • Suh, Jung-Ho;Suh, Myung-Gyo;Chung, Kyung-Tae;Lee, Yong-Hee
    • Journal of Life Science
    • /
    • v.16 no.6
    • /
    • pp.877-883
    • /
    • 2006
  • An alternative method to remove and recover heavy metals is biosorption based on metal-sequestering properties of natural or biological origin. In this study, the effects of factors such as temperature, pH, initial concentration of lead, and initial amount of biomass on biosorption of lead using Aureobasdium pullulans were investigated. A. pullulans has an excellent selectivity to remove lead than other heavy metals such as cadmium, chromium, nickel in pure and mixed solution. The optimum temperature of biosorption with A. pullulans was $40^{\circ}C$ and the amount of removal increased at high pH. The higher initial lead concentration or the lower cell dry weight, the higher amount of lead was adsorbed. The adsorption isotherm of lead was accorded with Freundlich model. The adsorption capacity and initial adsorption rate of living A. pullulans were about twice higher than that of dead one.

A basic study on the recovery of Ni, Cu, Fe, Zn ions from wastewater with the spent catalyst (폐산화철촉매에 의한 폐수중 Ni, Cu, Fe, Zn이온 회수에 관한 기초연구)

  • Lee Hyo Sook;Oh Yeung Soon;Lee Woo Chul
    • Resources Recycling
    • /
    • v.13 no.2
    • /
    • pp.3-8
    • /
    • 2004
  • A basic study on the recovery of heavy metals such as Zn, Ni, Cu and Fe ions from wastewater was carried out with the spent iron oxide catalyst, which was used in the Styrene Monomer(SM) production company. The heavy metals could be recovered more than 98% with the spent iron oxide catalyst. The alkaline components of the spent catalyst could be precipitated the metal ions of the wastewater as metal hydroxides at the higher pH 10.6 in Ni, pH 8.0 in Cu, pH 6.5 in Fe, pH 8.5 in Zn. But the metal ions are adsorbed physically on the surface of the spent catalyst in the range of the pH of the metal hydroxides and pH 3.0, which is the isoelectric point of the iron oxide catalyst.

Effect of Flux Composition on Weld Metal Toughness and Workability in Submerged Aye Welding with 60kgf/$\textrm{mm}^2$ Grade C-Mo Type Wires (60kgf/$\textrm{mm}^2$급 C-MO계 와이어를 사용한 서브머지드 아크 용접금속 인성 및 작업성에 미치는 플럭스 조성의 영향)

  • 방국수;안영호
    • Journal of Welding and Joining
    • /
    • v.14 no.6
    • /
    • pp.93-100
    • /
    • 1996
  • Effect of a flux composition on weld metal toughness in submerged arc welding with 60kgf/$\textrm{mm}^2$ grade C-Mo type wires was investigated and interpreted in terms of weld metal microstructure and hardenability. Flux workability was also studied by characterizing a weld bead profile. Compared to other weld metals, .weld metal used alumina basic flux with nickel showed lowest oxygen content, highest hardenability and the most acicular ferrite. The highest impact toughness of that weld metal, however, was attributed to the tough matrix due to the nickel rather than to the larger amount of acicular ferrite. Manganese silicate flux had better workability than alumina basic flux, showing broader welding conditions resulting in a depth-to-width ratio of 0.5. The composition of oxides in the weld metal was dependent on the flux composition, showing MnO-SiO$_2$-TiO in manganese silicate flux and MnO-SiO$_2$-Al$_2$O$_3$-TiO in alumina basic flux. MnO-SiO$_2$composition in both oxides was similar to a tephroite.

  • PDF

Comparison of USEPA Digestion Methods for Trace Metal Analysis Using SRM

  • Shin, Mi-Young;Yoon, Hyeon;Kim, Youn-Tae;Yoon, Cheol-Ho;Woo, Nam-Chil
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.223-226
    • /
    • 2004
  • The importance of a proper sample preparation and analysis technique has getting attention due to the complicity of toxic elements of interest from environmental samples depend on analytical purposes. It is critical to use proper analytical method to evaluate trace elements concentration in many environmental samples especially for making remediation decisions. Therefore, it is critical to apply a proper sampling and analytical method such as EPA publication SW-846 (Test Methods for Evaluating Solid Waste, Physical/chemical Methods). The objective of this study was to compare the USEPA Methods 3050B, modified 3050B, 305 la, and KBSI method (modified EPA 3052 Method) in term of recovery rate of metals. The NIST SRM (Montana soil) was used to compare the extraction and digestion efficiency. After sample has been collected the analysis were achieved by ICP-MS (Elan 6100, Perkin Elmer) as well as ICP-AES (Ultima 2C, JY) for trace elements and major elements.

  • PDF

Determination of Ag(Ⅰ) Ion at a Modified Carbon Paste Electrode Containing N,N'-Diphenyl Oxamide

  • Won, Mi-Sook;Yeom, Jeong-Sik;Yoon, Jang-Hee;Jeong, Euh-Duck;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.7
    • /
    • pp.948-952
    • /
    • 2003
  • New approach for the determination of Ag(I) ion was performed by using a carbon paste electrode (CPE) containing N,N'-Diphenyl oxamide (DPO) with anodic stripping voltammetry. The CMEs have been prepared by making carbon paste mixtures containing an appropriate amount of DPO salt coated onto graphite particles to analyze trace metal ions via complexation followed by stripping voltammetry. Various experimental parameters affecting the response, such as pH, deposition time, temperature, and electrode composition, were carefully optimized. Using differential pulse anodic stripping voltammetry, the logarithmic linear response range for the Ag(I) ion was 1.0 × $10^{-7}$ - 5.0 × $10^{-9}$ M at the deposition time of 10 min, with the detection limit was 7.0 × $10^{-10}$ M. The detection limit adopted from anodic stripping differential pulse voltammetry was 7.0 × $10^{-10}$ M for silver and the relative standard deviation was ± 3.2% at a 5.0 × $10^{-8}$ M of Ag(I) ion (n = 7). The proposed electrode shows a very good selectivity for Ag(I) in a standard solution containing several metals at optimized conditions.

Electrolytic Deposition of Metal Ions Using A Liquid Cadmium Cathode

  • Shim, Joon-Bo;Ahn, Byung-Gil;Kwon, Sang-Woon;Kim, Eung-Ho;Yoo, Jae-Hyung
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.337-337
    • /
    • 2004
  • As one of researches for the P & T purposes, a basic experiment on the recovery of actinide elements from the mixture with rare earth elements by means of electrorefining using a liquid cadmium cathode in the LiCl-KC1 eutectic melt was carried out. In order to examine the behaviors of electrodeposition of metal ions on a liquid electrode, recovery experiments of rare earth metals resulting from forming electrodeposits were performed by a galvanostatic electrolysis method at various current densities. A cyclic voltammetric technique was applied to determine reduction-oxidation potential of each metal element in the melt and to detect the changes of the multi component melt composition for on-line monitoring. Also, a collaboration study with RIAR was completed to test the preliminary feasibility on a recovery of actinide elements from the mixture with rare earth elements using a liquid cadmium cathode and actinide metals. Experimental results showed that the ratio of actinides to rare earths, 9: 0.5∼1 led to the rare earth content of about 5∼10 wt% in the deposit.

  • PDF