• Title/Summary/Keyword: Baseline profile

Search Result 121, Processing Time 0.028 seconds

Improvement of H.264 Encoder Using MMX (MMX를 이용한 H.264 인코더 성능 개선)

  • Kim, Sang-Ho;Lee, June-Hwan;Rhee, Sang-Burm
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.729-730
    • /
    • 2006
  • multimedia applications has been targeted for exploiting single instruction multiple data extensions to instruction architectures for the most of the modern microprocessor. In this paper, the newest video coding standard, H.264/AVC baseline profile decoder has been implemented and optimized exploiting INTEL MMX technology to show the overall system speedup by the SIMD style coding

  • PDF

Establishing RAM Requirement based on BCS model for Weapon Systems (BCS 모델을 이용한 무기체계 RAM 요구조건 수립)

  • Eo, Seong-Phil;Kim, Sung-Jin;Kim, Dae-Yong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.67-76
    • /
    • 2010
  • RAM(Reliability, Availability, Maintainability) characteristics of weapon system is a part of Required Operational Capability, must be reasonable and achievable. In this study, we studied the criteria, important factors to establish RAM requirement and reviewed the current process. Then we propose the new process and method to establish the reasonable and achievable RAM requirement by BCS(Baseline Comparison System) model.

MPEG-5 EVC Encoder Improvement for V-PCC

  • Dong, Tianyu;Jang, Euee S.
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2021.06a
    • /
    • pp.78-80
    • /
    • 2021
  • In this paper, we proposed an improved method on the picture order of coding (POC) of MPEG-5 Essential video Coding (EVC) encoder to support a short intra period for Video-based Point Cloud Compression (V-PCC). As a codec-agnostically designed standard, V-PCC claimed to be able to work with a lot of codecs. Current EVC test model software shows that the baseline profile could not provide appropriate POC calculation. The proposed method offers a solution to this POC-related problem and provides up to 44.6% coding grains for EVC based V-PCC.

  • PDF

NUMERICAL STUDY OF A CENTRIFUGAL PUMP PERFORMANCE WITH VARIOUS VOLUTE SHAPE (볼루트의 형상 변화가 원심펌프 성능에 미치는 영향에 대한 수치해석)

  • Lee, J.H.;Hur, N.;Yoon, I.S.
    • Journal of computational fluids engineering
    • /
    • v.20 no.3
    • /
    • pp.35-40
    • /
    • 2015
  • Centrifugal pumps consume considerable amounts of energy in various industrial applications. Therefore, improving the efficiency of pumps machine is a crucial challenge in industrial world. This paper presents numerical investigation of flow characteristics in volutes of centrifugal pumps in order to compare the energy consumption. A wide range of volumetric flow rate has been investigated for each case. The standard k-${\varepsilon}$ is adopted as the turbulence model. The impeller rotation is simulated employing the Multi Reference Frames(MRF) method. First, two different conventional design methods, i.e., the constant angular momentum(CAM) and the constant mean velocity (CMV) are studied and compared to a baseline volute model. The CAM volute profile is a logarithmic spiral. The CMV volute profile shape is an Archimedes spiral curve. The modified volute models show lower head value than baseline volute model, but in case of efficiency graph, CAM curve has higher values than others. Finally for this part, CAM curve is selected to be used in the simulation of different cross-section shape. Two different types of cross-section are generated. One is a simple rectangular shape, and the other one is fan shape. In terms of different cross-section shape, simple rectangular geometry generated higher head and efficiency. Overall, simulation results showed that the volute designed using constant angular momentum(CAM) method has higher characteristic performances than one by CMV volute.

Application and Verification of Time-Division Watermarking Algorithm in H.264 (시간 분할 워터마킹 알고리즘의 H.264 적용 및 검증)

  • Youn, Jin-Seon;Choi, Jun-Rim
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.6
    • /
    • pp.68-73
    • /
    • 2008
  • In this paper, we propose watermark algorithm called TDWA(Time-Division Watermarking Algorithm) and we applied the proposed algorithm to H.264 video coding standard. We establish that a proposed algorithm is applied to H.264 baseline profile CODEC. The proposed algorithm inserts a watermark into the spatial domain of several frames. We can easily insert strong and invisible watermarks into original pictures using this method. For verification of the proposed algorithm we design hardware core using Verilog-HDL and Excalibur for JM 8.7 code with hardware & software co-simulation. As a result of verification, the PSNR between watermarked pictures and original pictures are more than 60dB and we found the watermark is kept more than 80% after encoding of H.264/AVC with quantization parameter of 28 in baseline profile.

The Development of Performance Analysis Code for Conceptual Design of Jet Fighters (전투기의 개념설계를 위한 성능해석 프로그램 개발)

  • Kim, Taewoo;Choi, Hyunmin;Choi, Byungryul;Lee, Sungjin;Nam, Hwajin;Choi, Donghoon;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.5
    • /
    • pp.404-414
    • /
    • 2013
  • In the conceptual design phase of jet fighters, the trade study is performed repeatedly for a selection of the baseline configuration. The automation of repeated trade study makes possible to select efficiently the baseline configuration. In this study, the performance analysis code was developed for the automation of trade study. The code was consists of the module of shape generation, the module of weight estimation, the module of mission performance analysis. 3D CAD Model can be generated by the module of shape generation and Weight can be estimated by using the empirical equation in the module of weight estimation. The module of mission performance analysis was able to calculate the mission performance about the arbitrary mission profile. In addition, the optimal mission performance can be calculated by using optimization method. By performing the validation, the code was confirmed to be able to apply to the conceptual design phase.

No short-term effects of calorie-controlled Mediterranean or fast food dietary interventions on established biomarkers of vascular or metabolic risk in healthy individuals

  • Parcina, Marijo;Brune, Maik;Kaese, Vareska;Zorn, Markus;Spiegel, Rainer;Vojvoda, Valerija;Fleming, Thomas;Rudofsky, Gottfried;Nawroth, Peter Paul
    • Nutrition Research and Practice
    • /
    • v.9 no.2
    • /
    • pp.165-173
    • /
    • 2015
  • BACKGROUND/OBJECTIVES: This study addressed the question whether the composition of supposedly 'healthy' or 'unhealthy' dietary regimes has a calorie-independent short-term effect on biomarkers of metabolic stress and vascular risk in healthy individuals. SUBJECTS/METHODS: Healthy male volunteers (age $29.5{\pm}5.9years$, n = 39) were given a standardized baseline diet for two weeks before randomization into three groups of different dietary regimes: fast food, Mediterranean and German cooking style. Importantly, the amount of calories consumed per day was identical in all three groups. Blood samples were analyzed for biomarkers of cardiovascular risk and metabolic stress after two weeks of the baseline diet and after two weeks of the assigned dietary regime. RESULTS: No dietary intervention affected the metabolic or cardiovascular risk profile when compared in-between groups or compared to baseline. Subjects applied to the Mediterranean diet showed a statistically significant increase of uric acid compared to baseline and compared to the German diet group. Plasma concentrations of urea were significantly higher in both the fast food group and the Mediterranean group, when compared to baseline and compared to the German diet group. No significant differences were detected for the levels of vitamins, trace elements or metabolic stress markers (8-hydroxy-2-deoxyguanosine, malondialdehyde and methylglyoxal, a potent glycating agent). Established parameters of vascular risk (e.g. LDL-cholesterol, lipoprotein(a), homocysteine) were not significantly changed in-between groups or compared to baseline during the intervention period. CONCLUSIONS: The calorie-controlled dietary intervention caused neither protective nor harmful short-term effects regarding established biomarkers of vascular or metabolic risk. When avoiding the noxious effects of overfeeding, healthy individuals can possess the metabolic capacity to compensate for a potentially disadvantageous composition of a certain diet.

Global Shape Optimization of Airfoil Using Multi-objective Genetic Algorithm (다목적 유전알고리즘을 이용한 익형의 전역최적설계)

  • Lee, Ju-Hee;Lee, Sang-Hwan;Park, Kyoung-Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.10 s.241
    • /
    • pp.1163-1171
    • /
    • 2005
  • The shape optimization of an airfoil has been performed for an incompressible viscous flow. In this study, Pareto frontier sets, which are global and non-dominated solutions, can be obtained without various weighting factors by using the multi-objective genetic algorithm An NACA0012 airfoil is considered as a baseline model, and the profile of the airfoil is parameterized and rebuilt with four Bezier curves. Two curves, front leading to maximum thickness, are composed of five control points and the rest, from maximum thickness to tailing edge, are composed of four control points. There are eighteen design variables and two objective functions such as the lift and drag coefficients. A generation is made up of forty-five individuals. After fifteenth evolutions, the Pareto individuals of twenty can be achieved. One Pareto, which is the best of the . reduction of the drag furce, improves its drag to $13\%$ and lift-drag ratio to $2\%$. Another Pareto, however, which is focused on increasing the lift force, can improve its lift force to $61\%$, while sustaining its drag force, compared to those of the baseline model.

A retrospective comparison of 3 approaches of vestibuloplasty around mandibular molar implants: apically positioned flap versus free gingival graft versus modified periosteal fenestration

  • Lee, Won-Pyo;Lee, Kyoung-Hoon;Yu, Sang-Joun;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.5
    • /
    • pp.364-372
    • /
    • 2021
  • Purpose: This study aimed to clinically evaluate the efficacy of vestibuloplasty around lower molar implants using 3 different modalities: apically positioned flap alone (APF), APF with a free gingival graft (FGG), and APF with modified periosteal fenestration (mPF). Methods: Three different vestibuloplasty procedures during second-stage implant surgery were performed at the mandibular molar area in 61 patients with a shallow vestibule and insufficient keratinized tissue (KT). The clinical measurements of KT width were recorded at baseline, immediately after surgery (T0), 6 months after surgery (T6), and 12 months after surgery (T12). Soft tissue esthetic scores were measured. Results: An additional KT width gain from baseline to T12 of approximately 2 mm was obtained with FGG and mPF compared to that with APF. Shrinkage of the re-established tissue was lower with mPF and FGG than with APF, whereas the esthetic profile was better with APF and mPF than with FGG. Conclusions: Within the limitations of this study, mPF showed potential as a promising approach for vestibuloplasty around the lower molar implants compared to the traditional APF and FGG.

Force Assessment of Thermoformed and Direct-printed Aligners in a Lingual Bodily Movement of a Central Incisor Over Time: A 14-day In Vitro Study

  • Mary Linda Remley;Gabriel Ferreira Pessoa Carvalho Miranda ;Brent Bankhead;Julie McCray;Ki Beom Kim
    • Journal of Korean Dental Science
    • /
    • v.16 no.1
    • /
    • pp.23-34
    • /
    • 2023
  • Purpose: This study aims to investigate the force delivery profile of thermoformed aligners (TFA) compared with direct-printed aligners (DPA) and to explore the effect of different activation amounts on forces and moments of respective groups. A secondary objective is to observe the amount of stress relaxation that occurs over the 7~14 days when aligners are maintained in a simulated intraoral environment. Materials and Methods: An in vitro setup was created to quantify forces and moments. It consisted of a three dimensional-printed base plate and segmented maxillary teeth, placed in a semi-enclosed chamber to maintain a temperature of 37℃. Ninety clear aligners were divided into nine groups of ten aligners each based on material types (Zendura, ATMOS, TC-85) and activation amounts. Aligners were created with 0.00, 0.25- and 0.50-mm activations for lingual bodily movement of the upper left central incisor and kept on models in the "stressed" position in a 37℃ water bath. Three force components acting on the upper left lateral incisor, upper left central incisor, and upper right central incisor were measured for each time point, beginning from the initial baseline measurement, 8 hours, 16 hours, 24 hours, 2 days, 3 days, 4 days, 5 days, 6 days, 7 days, and lastly, 14 days. Result: TC-85 aligners in every activation group showed less force on teeth than Zendura and ATMOS. Significant force levels from 0.0 mm activation were present and stayed consistent over the course of 14 days. Comparisons made for baseline measurements to 7-days and 14-days showed statistically significant change from the baseline force level. Conclusion: TC-85 aligners demonstrated lower, more consistent forces with fewer side effects. Aligners can generate forces even when no activation is programmed. No major decreases in force levels over time were observed; the intra-oral clinical simulated environment and length of observation time could contribute to this.