• Title/Summary/Keyword: Baseline Detection

Search Result 252, Processing Time 0.034 seconds

Liquid chromatographic enantioseparation of several amino acids as nitrobenzoxadiazole derivatives on polysaccharide trisphenylcarbamate derived chiral stationary phases

  • Suraj Adhikari;Alisha Bhandari;Wonjae Lee
    • Analytical Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.143-151
    • /
    • 2023
  • Considering the greater role of α-amino acids in our daily lives, the enantiomer resolution of seven α-amino acids derivatized with fluorogenic reagent (4-fluoro-7-nitro-2,1,3-benzoxadiazole, NBD-F) by chiral HPLC on amylose or cellulose trisphenylcarbamate derived chiral stationary phases (CSPs) under simultaneous ultraviolet (UV) and fluorescence (FL) detection was performed. The degree of enantioseparation and resolution was affected by nature and selector backbones of the CSPs as well as the kind of amino acids. Baseline enantiomer separation and resolutions were observed for the enantiomers of all analytes as NBD derivatives especially on coated type amylose tris(3,5-dimethylphenylcarbamate) derived CSPs (Chiralpak AD-H and Lux Amylose-1). The other CSPs also showed good enantioselectivity except for the CSPs (Chiralpak IB, Chiralcel OD-H and Lux Cellulose-1) having cellulose tris(3,5-dimethylphenylcarbamate) as chiral selectors. The developed analytical chiral method was applied to determine the enantiomeric purity of seven commercially available L-α-amino acids and the impurities as D-forms were found to be in the range 0.08-0.87 %, respectively. The intra- and interday accuracy and precision assays showed high accuracy and precision of the developed analytical method. This chiral HPLC method for the enantiomer resolution of amino acids using fluorescent derivatization could be useful for the determination of enantiomeric purity of pharmaceuticals and biological study for amino acid type compounds among chiral drugs.

KVNCS: 2. The Fringe Survey of New Candidates for VLBI Calibrators in the K Band

  • Jeong Ae Lee;Taehyun Jung;Bong Won Sohn;Do-Young Byun
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.2
    • /
    • pp.159-168
    • /
    • 2023
  • The main goal of the Korean VLBI Network Calibrator Survey (KVNCS) is to expand the VLBI calibrators catalog for KVN, KaVA (KVN and VERA Array), EAVN (East-Asian VLBI Network), and other extended regions. The second KVNCS (KVNCS2) aimed to detect VLBI fringes of new candidates for calibrators in the K band. Out of the 1533 sources whose single-dish flux density in the K band was measured with KVN telescopes (Lee et al. 2017), 556 sources were observed with KVN in the K band. KVNCS2 confirmed the detection of VLBI fringes of 424 calibrator candidates over a single baseline. All detected sources had a high Signal-to-Noise Ratio (SNR) of >25. Finally, KVNCS2 confirmed 347 new candidates as VLBI calibrators in the K band, resulting in a 5% increase in the sky coverage compared to previous studies. The spatial distribution was quasi-uniform across the observable region (Dec. > -32.5°). In addition, the possibility as calibrator candidates for the detected sources was checked, using an analysis of the flux-flux relationship. Ultimately, the KVNCS catalog will not only become the VLBI calibrator list but is also useful as a database of compact radio sources for astronomical studies.

Non-iterative pulse tail extrapolation algorithms for correcting nuclear pulse pile-up

  • Mohammad-Reza Mohammadian-Behbahani
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4350-4356
    • /
    • 2023
  • Radiation detection systems working at high count rates suffer from the overlapping of their output electric pulses, known as pulse pile-up phenomenon, resulting in spectrum distortion and degradation of the energy resolution. Pulse tail extrapolation is a pile-up correction method which tries to restore the shifted baseline of a piled-up pulse by extrapolating the overlapped part of its preceding pulse. This needs a mathematical model which is almost always nonlinear, fitted usually by a nonlinear least squares (NLS) technique. NLS is an iterative, potentially time-consuming method. The main idea of the present study is to replace the NLS technique by an integration-based non-iterative method (NIM) for pulse tail extrapolation by an exponential model. The idea of linear extrapolation, as another non-iterative method, is also investigated. Analysis of experimental data of a NaI(Tl) radiation detector shows that the proposed non-iterative method is able to provide a corrected spectrum quite similar with the NLS method, with a dramatically reduced computation time and complexity of the algorithm. The linear extrapolation approach suffers from a poor energy resolution and throughput rate in comparison with NIM and NLS techniques, but provides the shortest computation time.

Novel upper gastrointestinal bleeding sensor capsule: a first human feasibility and safety trial

  • Lukas Bajer;Marvin Ryou;Christopher C. Thompson;Pavel Drastich
    • Clinical Endoscopy
    • /
    • v.57 no.2
    • /
    • pp.203-208
    • /
    • 2024
  • Background/Aims: Upper gastrointestinal bleeding (UGIB) is the most common GI condition requiring hospitalization. The present study aimed to evaluate the safety and feasibility of using the PillSense system (EnteraSense Ltd.), a novel diagnostic tool designed for the rapid in vivo detection of UGIB, in human volunteers. Methods: In the present study, 10 volunteers swallowed a PillSense capsule, followed by 2 servings of an autologous blood preparation. Participants were monitored for capsule passage, overall tolerability of the procedure, and adverse events. Results: The procedure was completed per the protocol established in the present study in 9/10 cases. In 9 of the subjects, after capsule ingestion, the device indicated the absence of blood with sensor output values of 1. After the ingestion of the first blood mixture, the sensor outputs of all devices increased to a range from 2.8 to 4, indicating that each sensor capsule detected blood. The sensor output remained within that range after the ingestion of the second mixture; however, in one case, the baseline capsule signal was positive, because of a preexisting condition. The passage of the capsule was verified in all patients, and no adverse events were reported. Conclusions: The first trial of the PillSense system in human subjects demonstrated the feasibility, safety, and tolerability of utilizing this product as a novel, noninvasive, and easy-to-use triage tool for the diagnosis of patients suspected of having UGIB.

Nitroglycerin-Challenged Tc-99m MIBI Quantitative Gated SPECT to Predict Functional Recovery After Coronary Artery Bypass Surgery (니트로글리세린 투여 Tc-99m-MIBI 정량 게이트 심근SPECT를 이용한 관상동맥우회로술 후 심근 기능 회복 예측)

  • Lee, Dong-Soo;Kim, Yu-Kyeong;Cheon, Gi-Jeong;Paeng, Jin-Chul;Lee, Myoung-Mook;Kim, Ki-Bong;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.5
    • /
    • pp.278-287
    • /
    • 2003
  • Purpose: The performance of nitroglycerin-challenged Tc-99m-MIBI quantitative gated SPECT for the detection of viable myocardium was compared with rest/24-hour redistribution Tl-201 SPECT Materials and Methods: In 22 patients with coronary artery disease, rest Tl-20l/ dipyridamole stress Tc-99m-MIBI gated/24-hour redistribution Tl-201 SPECT were peformed, and gated SPECT was repeated on-site after sublingual administration of nitroglycerin (0.6 mg). Follow-up gated SPECT was done 3 months after coronary artery bypass graft surgery. For 20 segments per patient, perfusion at rest and 24-hour redistribution, and wall motion and thickening at baseline and nitroglycerin-challenged state were quantified. Quantitative viability markers were evaluated and compared;(1) rest thallium uptake, (2) thallium uptake on 24-hour redistribution SPECT, (3) systolic wall thickening at baseline, and (4) systolic wall thickening with nitroglycerin-challenge. Results: Among 100 revascularized dysfunctional segments, wall motion improved in 66 segments (66%) on follow-up gated myocardial SPECT after bypass surgery. On receiver operating characteristic (ROC) curve analysis, the sensitivity and specificity of rest and 24-hour delayed redistribution Tl-201 SPECT were 79%, 44% and 82%, 44%, respectively, at the optimal cutoff value of 50% of Tl-201 uptake. The sensitivity and specificity of systolic wall thickening at baseline and nitroglycerin-challenge were 49%, 50% and 64%, 65% at the optimal cutoff value of 15% of systolic wall thickening. Area under the ROC curve of nitroglycerin-challenged systolic wall thickening was significantly larger than that of baseline systolic wall thickening (p=0.004). Conclusion: Nitroglycerin-challenged quantitative gated Tc-99m-MIBI SPECT was a useful method for predicting functional recovery of dysfunctional myocardium.

DETECTION AND MASKING OF CLOUD CONTAMINATION IN HIGH-RESOLUTION SST IMAGERY: A PRACTICAL AND EFFECTIVE METHOD FOR AUTOMATION

  • Hu, Chuanmin;Muller-Karger, Frank;Murch, Brock;Myhre, Douglas;Taylor, Judd;Luerssen, Remy;Moses, Christopher;Zhang, Caiyun
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.1011-1014
    • /
    • 2006
  • Coarse resolution (9 - 50 km pixels) Sea Surface Temperature satellite data are frequently considered adequate for open ocean research. However, coastal regions, including coral reef, estuarine and mesoscale upwelling regions require high-resolution (1-km pixel) SST data. The AVHRR SST data often suffer from navigation errors of several kilometres and still require manual navigation adjustments. The second serious problem is faulty and ineffective cloud-detection algorithms used operationally; many of these are based on radiance thresholds and moving window tests. With these methods, increasing sensitivity leads to masking of valid pixels. These errors lead to significant cold pixel biases and hamper image compositing, anomaly detection, and time-series analysis. Here, after manual navigation of over 40,000 AVHRR images, we implemented a new cloud filter that differs from other published methods. The filter first compares a pixel value with a climatological value built from the historical database, and then tests it against a time-based median value derived for that pixel from all satellite passes collected within ${\pm}3$ days. If the difference is larger than a predefined threshold, the pixel is flagged as cloud. We tested the method and compared to in situ SST from several shallow water buoys in the Florida Keys. Cloud statistics from all satellite sensors (AVHRR, MODIS) shows that a climatology filter with a $4^{\circ}C$ threshold and a median filter threshold of $2^{\circ}C$ are effective and accurate to filter clouds without masking good data. RMS difference between concurrent in situ and satellite SST data for the shallow waters (< 10 m bottom depth) is < $1^{\circ}C$, with only a small bias. The filter has been applied to the entire series of high-resolution SST data since1993 (including MODIS SST data since 2003), and a climatology is constructed to serve as the baseline to detect anomaly events.

  • PDF

Development of a Stress ECG Analysis Algorithm Using Wavelet Transform (웨이브렛 변환을 이용한 스트레스 심전도 분석 알고리즘의 개발)

  • 이경중;박광리
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.269-278
    • /
    • 1998
  • This paper describes a development of efficient stress ECG signal analysis algorithm. The algorithm consists of wavelet adaptive filter(WAF), QRS detector and ST segment detector. The WAF consists of a wavelet transform and an adaptive filter. The wavelet transform decomposed the ECG signal into seven levels using wavelet function for each high frequency bank and low frequency bank. The adaptive filter used the signal of the seventh lowest frequency band among the wavelet transformed signals as primary input. For detection of QRS complex, we made summed signals that are composed of high frequency bands including frequency component of QRS complex and applied the adaptive threshold method changing the amplitude of threshold according to RR interval. For evaluation of the performance of the WAF, we used two baseline wandering elimination filters including a standard filter and a general adaptive filter. WAF showed a better performance than compared filters in the noise elimination characteristics and signal distortion. For evaluation of WAF showed a better performance than compared filters in the noise elimination characteristics and signal distortion. For evaluation of results of QRS complex detection, we compared our algorithm with existing algorithms using MIT/BIH database. Our algorithm using summed signals showed the accuracy of 99.67% and the higher performance of QRS detection than existing algorithms. Also, we used European ST-T database and patient data to evaluate measurement of the ST segment and could measure the ST segment adaptively according to change of heart rate.

  • PDF

Evaluation of the Effectiveness of Surveillance on Improving the Detection of Healthcare Associated Infections (의료관련감염에서 감시 개선을 위한 평가)

  • Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.1
    • /
    • pp.15-25
    • /
    • 2019
  • The development of reliable and objective definitions as well as automated processes for the detection of health care-associated infections (HAIs) is crucial; however, transformation to an automated surveillance system remains a challenge. Early outbreak identification usually requires clinicians who can recognize abnormal events as well as ongoing disease surveillance to determine the baseline rate of cases. The system screens the laboratory information system (LIS) data daily to detect candidates for health care-associated bloodstream infection (HABSI) according to well-defined detection rules. The system detects and reserves professional autonomy by requiring further confirmation. In addition, web-based HABSI surveillance and classification systems use discrete data elements obtained from the LIS, and the LIS-provided data correlates strongly with the conventional infection-control personnel surveillance system. The system was timely, acceptable, useful, and sensitive according to the prevention guidelines. The surveillance system is useful because it can help health care professionals better understand when and where the transmission of a wide range of potential pathogens may be occurring in a hospital. A national plan is needed to strengthen the main structures in HAI prevention, Healthcare Associated Prevention and Control Committee (HAIPCC), sterilization service (SS), microbiology laboratories, and hand hygiene resources, considering their impact on HAI prevention.

Minimum Detectable Radioactivity Concentration of Atmospheric Particulate Measurement System for Nuclear Test Monitoring (핵활동 감시를 위한 대기 입자 측정시스템의 최소검출 방사능 농도 결정)

  • Kim, Jong-Soo;Yoon, Suk-Chul;Shin, Jang-Soo;Kwack, Eun-Ho;Choi, Jong-Seo
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.111-117
    • /
    • 1997
  • Recently, the conclusion of Comprehensive Test Ban Treaty(CTBT) is globally constructing a network system for nuclear test monitoring. The radionuclide experts of the Conference on Disarmament recommended that the detection of nuclear debris in the atmosphere was an essential factor of nuclear test monitoring and proposed the technical requirements. Based on those requirements, atmospheric radionuclide monitoring system to detect nuclear debris generated from the nuclear explosion test was composed. The system is comprised of high volume air sampler(HVAS), filter paper presser and high purity germanium detector(HPGe). Minimum detectable concentrations(MDCs) of the key nuclides requiring in CTBT monitoring strategies are determined by considering of decay time, counting time and flow rate of the high volume air sampler for the rapid explosion and the optimum measurement condition. The results were selected $10{\pm}$2h, $20{\pm}$2h and $850{\pm}50m^3$/h as parameters, respectively. The relation between the natural air-borne radionuclide concentration of $^{212}Pb$ and MDC were calculated which gave effect in the Compton continuum baseline due to those nuclides in the gamma-ray spectroscopy. These results can be used as an actually tool in the CTBT monitoring strategies.

  • PDF

Detection for the Resistance of Fusarium spp. Isolated from Rice Seeds to Prochloraz and Cross-resistance to Other Fungicides Inhibiting Sterol Biosynthesis (벼 종자에서 분리한 Fusarium속 균주들의 prochloraz에 대한 저항성 검정 및 교차 저항성 조사)

  • Shin, Myeong-Uk;Kang, Hyo-Jung;Lee, Yong-Hwan;Kim, Heung-Tae
    • The Korean Journal of Pesticide Science
    • /
    • v.12 no.3
    • /
    • pp.277-282
    • /
    • 2008
  • To assess the resistance to prochloraz, $EC_{50}$ values of Fusarium isolates obtained from rice seed were investigated through the agar dilution method. $EC_{50}$ value of 36 isolates of Fusarium spp. to prochloraz ranged from 0.020 to $1.78{\mu}g\;mL^{-1}$ with an average of $0.25{\mu}g\;mL^{-1}$. According to the species of Fusarium, the average $EC_{50}$ value was fluctuated; $0.091{\mu}g\;mL^{-1}$ for F. moniliformis, $0.11{\mu}g\;mL^{-1}$ for F. proliferatum and $0.31{\mu}g\;mL^{-1}$ for F. fujikuroi. The resistant baseline was decided at $0.5{\mu}g\;mL^{-1}$ to determine if the isolate was resistant to prochloraz or not. Based on the resistant baseline, the ratio of resistant isolates was 14%. There was no correlation between the resistance to prochloraz and the pathogenicity of Fusarium spp. on rice seedlings. The resistant isolates of F. fujikuroi did not show the cross-resistance to other sterol biosynthesis inhibiting fungicides, triflumizole, hexaconazole, difenoconazole and tebuconazole.