• 제목/요약/키워드: Base-isolation

검색결과 482건 처리시간 0.026초

Seismic isolation of hospital buildings

  • Soldatova, Liudmila;Jumukov, Sulaiman
    • Smart Structures and Systems
    • /
    • 제2권4호
    • /
    • pp.329-337
    • /
    • 2006
  • This paper illustrates an analytical investigation of the vibration parameters of buildings on sliding seismic isolation bearings with elastic limiters of the relative displacement. The installation scheme of sliding bearings and elastic limiters for the separate unit of a 4 storey hospital building with brick walls is designed. The analysis of the vibrations of the hospital building is conducted for harmonic base excitation.

Seismic protection of LNG tanks with reliability based optimally designed combined rubber isolator and friction damper

  • Khansefid, Ali;Maghsoudi-Barmi, Ali;Khaloo, Alireza
    • Earthquakes and Structures
    • /
    • 제16권5호
    • /
    • pp.523-532
    • /
    • 2019
  • Different types of gas reservoir such as Liquid Natural Gas (LNG) are among the strategic infrastructures, and have great importance for any government or their private owners. To keep the tank and its contents safe during earthquakes especially if the contents are of hazardous or flammable materials; using seismic protection systems such as base isolator can be considered as an effective solution. However, the major deficiency of this system can be the large deformation in the isolation level which may lead to the failure of bearing system. In this paper, as a solution, the efficacy of an optimally designed combined vibration control system, the combined laminated rubber isolator and rotational friction damper, is investigated to evaluate the enhancement of an existing metal tank response under both far- and near-field earthquakes. Responses like impulsive and convective accelerations, base shear, and sloshing height are studied herein. The probabilistic framework is used to consider the uncertainties in the structural modeling, as well as record-to-record variability. Due to the high calculation cost of probabilistic methods, a simplified structural model is used. By using the Mont-Carlo simulation approach, it is revealed that this combined isolation system is a highly reliable system which provides considerable enhancement in the performance of reservoir, not only leads to the reduction of probability of catastrophic failure of the tank but also decrease the reservoir damage during the earthquake. Moreover, the relative displacement of the isolation level is controlled very well by this combined system.

한국산 Thalictrum속 식물의 성분연구(II) 자주꿩의 다리 뿌리의 성분 (Isolation and Identification of Phenolic Tertiary and Quaternary Alkaloids from Thalictrum uchiyamai)

  • 이인란
    • 약학회지
    • /
    • 제28권3호
    • /
    • pp.185-190
    • /
    • 1984
  • Protothalipine colorless needle crystal, mp $195-6^{\circ}$, $C_{21}H_{25}NO_{5}$) and jatrorrhizine chloride (Base A, orange needle crystal, mp $198^{\circ}$) are identified by chemical, spectral analysis, and comparison with authentic sample. Base B (reddish crystal, mp $192-4^{\circ}$) might be a artifact substance, which was changed from the jatrorrhizine chloride. Base C (yellowish needle crystal, mp $228~230^{\circ}$) and Base D (reddish needle crystal, mp $211~213^{\circ}$) were assumed to be thalifendine chloride, desoxythalidastine chloride by phytochemical and spectral analysis respectively.

  • PDF

Bouc-Wen 모델을 이용한 면진장치의 최적설계 (Optimum Design of Base Isolators Using Bouc-Wen Model)

  • 문석준;정정훈;김병현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.395-402
    • /
    • 2003
  • Characteristics of base isolators including frictional and hysteretic types may be described by Bouc-Wen model. A probabilistic optimum design method of the base isolation system using Bouc-Wen model is presented in this paper. For optimum design, the objective function and constraints are derived based on the stochastic responses of the system. As a numerical example, the optimum design problem of a three-story base isolated shear type structure is formulated and solved by the sequential quadratic programming method.

  • PDF

퍼지관리제어기법을 이용한 스마트 면진 벤치마크 건물의 제어 (Control of Smart Base-isolated Benchmark Building using Fuzzy Supervisory Control)

  • 김현수
    • 한국지진공학회논문집
    • /
    • 제9권4호
    • /
    • pp.55-66
    • /
    • 2005
  • 본 논문에서는 스마트 면진장치를 효과적으로 제어하기 위하여 퍼지관리제어기를 개발하였고 그 효율성을 검토하였다. 이를 위하여 1세대 스마트 면진 벤치마크 건물을 이용하여 수치해석을 수행하였다. 대상 벤치마크 구조물은 부정형의 평면을 가지고 있는 8층 건물이고 탄성베어링과 MR 감쇠기로 이루어진 스마트 면진장치가 설치되어 있다. 본 논문에서는 다목적 유전자 알고리즘을 이용하여 원거리 지진과 근거리 지진에 대하여 각각 면진구조물을 효과적으로 제어할 수 있는 하위 퍼지제어기를 개발한다. 최적화과정에서는 구조물의 최대 및 RMS 가속도와 면진층 변위의 저감이 목적으로 사용된다. 벤지마크 건물에 지진하중이 가해지면 두 개의 하위 퍼지제어기에서는 각각 다른 명령전압이 제공되는데 이 명령전압들은 퍼지관리제어기의 추론과정에 기반하여 실시간으로 참여율이 조절되어 하나의 명령전압으로 조합된다. 수치해석을 통하여 제안된 퍼지관리제어기법을 사용함으로써 상부구조물의 응답과 면진층의 변위를 효과적으로 줄일 수 있음을 확인할 수 있다.

Piecewise exact solution for analysis of base-isolated structures under earthquakes

  • Tsai, C.S.;Chiang, Tsu-Cheng;Chen, Bo-Jen;Chen, Kuei-Chi
    • Structural Engineering and Mechanics
    • /
    • 제19권4호
    • /
    • pp.381-399
    • /
    • 2005
  • Base isolation technologies have been proven to be very efficient in protecting structures from seismic hazards during experimental and theoretical studies. In recent years, there have been more and more engineering applications using base isolators to upgrade the seismic resistibility of structures. Optimum design of the base isolator can lessen the undesirable seismic hazard with the most efficiency. Hence, tracing the nonlinear behavior of the base isolator with good accuracy is important in the engineering profession. In order to predict the nonlinear behavior of base isolated structures precisely, hundreds even thousands of degrees-of-freedom and iterative algorithm are required for nonlinear time history analysis. In view of this, a simple and feasible exact formulation without any iteration has been proposed in this study to calculate the seismic responses of structures with base isolators. Comparison between the experimental results from shaking table tests conducted at National Center for Research on Earthquake Engineering in Taiwan and the analytical results show that the proposed method can accurately simulate the seismic behavior of base isolated structures with elastomeric bearings. Furthermore, it is also shown that the proposed method can predict the nonlinear behavior of the VCFPS isolated structure with accuracy as compared to that from the nonlinear finite element program. Therefore, the proposed concept can be used as a simple and practical tool for engineering professions for designing the elastomeric bearing as well as sliding bearing.

대칭섹터 간 주파수 간섭 감소를 위한 편파분리 및 자원 제어 방법 (Antenna Polarization Isolation and Resource Control for Frequency Interference Reduction Between Opposite Sectors)

  • 서성원;이성민;김용신
    • 한국통신학회논문지
    • /
    • 제40권6호
    • /
    • pp.1014-1023
    • /
    • 2015
  • 본 논문은 대칭섹터 간 주파수 재사용에 따른 주파수 간섭 감소를 위한 편파 분리 및 자원 제어방법에 대한 것이다. 기지국 장비가 운용되면서 발생하는 대칭섹터 간 주파수 간섭을 감소시키기 위한 실험을 진행하였다. 기지국 장비는 대칭섹터에서 같은 주파수를 재사용 하는 구조로 In-Band 주파수 간섭이 야기된다. 따라서 주파수 간섭을 최소화하기 위해 본 논문에서는 2가지 방안을 제시하였다. 첫 번째로 대칭섹터의 안테나 편파 분리 방법이다. 편파 분리 방법을 사용함으로 CINR이 17dB에서 27dB로 약 10dB의 향상되었다. 두 번째 방법은 기지국 링크별 자원을 제어하는 방법으로 링크별 RF 송신출력을 정렬하여 자원을 할당하는 방법과 링크별 RF 송신출력 제어범위를 조정하는 방법이 있다. 본 논문에서는 제안된 두 가지 방안을 사용하여 주파수 재사용하는 구조에서 주파수 간섭을 줄일 수 있는 방안을 제시하였다.

원전기기의 면진을 위한 진동대 실험 II : FPS (A Shaking Table Test for Equipment Isolation in the NPP (II): FPS)

  • 김민규;전영선;최인길
    • 한국지진공학회논문집
    • /
    • 제8권5호통권39호
    • /
    • pp.79-89
    • /
    • 2004
  • 본 연구에서는 원전기기의 내진안전성을 증가시키기 위해 면진장치를 적용한 기기의 진동대 실험을 수행하였다. 원전구조물과 유사한 진동수 특성을 가지는 실험모형을 제작하여 실험에 사용하였으며 구조물 내부의 기기를 모형화 하기 위하여 400kg의 강체를 사용하였다. 탁월주파수 특성이 상이한 3종류 지진파를 이용하여 진동대 실험을 수행하였다. 면진장치로는 마찰진자형 베어링(FPS)을 사용하였다. 입력지진의 최대가속도를 0.1g, 0.2g, 0.25g의 3단계로 변화시키면서 실험을 수행하였고 또한 1방향, 2방향 및 3방향 가진에 의한 거동을 분석하였다. 실험결과 지진파의 연직성분이 FPS의 면진성능에 영향을 미치는 것을 알 수 있었으며 펄스타입의 속도성분이 큰 근거리 지진인 경우 면진효과가 감소하는 것을 알 수 있었다.

Comparison of seismic behavior of long period SDOF systems mounted on friction isolators under near-field earthquakes

  • Loghman, Vahid;Khoshnoudian, Faramarz
    • Smart Structures and Systems
    • /
    • 제16권4호
    • /
    • pp.701-723
    • /
    • 2015
  • Friction isolators are one of the most important types of bearings used to mitigate damages of earthquakes. The adaptive behavior of these isolators allows them to achieve multiple levels of performances and predictable seismic behavior during different earthquake hazard levels. There are three main types of friction isolators. The first generation with one sliding surface is known as Friction Pendulum System (FPS) isolators. The double concave friction pendulum (DCFP) with two sliding surfaces is an advanced form of FPS, and the third one, with fully adaptive behavior, is named as triple concave friction pendulum (TCFP). The current study has been conducted to investigate and compare seismic responses of these three types of isolators. The structure is idealized as a two-dimensional single degree of freedom (SDOF) resting on isolators. The coupled differential equations of motion are derived and solved using state space formulation. Seismic responses of isolated structures using each one of these isolators are investigated under seven near fault earthquake motions. The peak values of bearing displacement and base shear are studied employing the variation of essential parameters such as superstructure period, effective isolation period and effective damping of isolator. The results demonstrate a more efficient seismic behavior of TCFP isolator comparing to the other types of isolators. This efficiency depends on the selected effective isolation period as well as effective isolation damping. The investigation shows that increasing the effective isolation period or decreasing the effective isolation damping improves the seismic behavior of TCFP compared to the other isolators. The maximum difference in seismic responses, the base shear and the bearing displacement, for the TCFP isolator are calculated 26.8 and 13.4 percent less than the DCFP and FPS in effective isolation damping equal to10%, respectively.