• Title/Summary/Keyword: Base-isolation

Search Result 485, Processing Time 0.024 seconds

A Shaking Table Test for Equipment Isolation in the NPP (I): Rubber Bearing (원전기기의 면진을 위한 진동대 실험 I : 고무베어링)

  • Kim, Min-Kyu;Choun, Young-Sun;Choi, In-Kil
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.5 s.39
    • /
    • pp.65-77
    • /
    • 2004
  • In this study, the base isolation systems for equipment in the NPP are presented and the responses of each isolation system are investigated. As for the base isolation systems, a natural rubber bearing (NRB) and a high damping rubber bearing (HDRB) are selected. As input motions, artificial time histories enveloping the US NRC RG 1.60 spectrum and the probability-based scenario earthquake spectra developed for the Korean nuclear power plant site as well as a typical near-fault earthquake record are used. Uniaxial, biaxial, and triaxial excitations are conducted with PGAs of 0.1, 0.2 and 0.25g. The reduction of the seismic forces transmitted to the equipment models are determined for different isolation systems and input motions.

Seismic Fragility Analysis of Base Isolated NPP Piping Systems (지진격리된 원전배관의 지진취약도 분석)

  • Jeon, Bub Gyu;Choi, Hyoung Suk;Hahm, Dae Gi;Kim, Nam Sik
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.29-36
    • /
    • 2015
  • Base isolation is considered as a seismic protective system in the design of next generation Nuclear Power Plants (NPPs). If seismic isolation devices are installed in nuclear power plants then the safety under a seismic load of the power plant may be improved. However, with respect to some equipment, seismic risk may increase because displacement may become greater than before the installation of a seismic isolation device. Therefore, it is estimated to be necessary to select equipment in which the seismic risk increases due to an increase in the displacement by the installation of a seismic isolation device, and to perform research on the seismic performance of each piece of equipment. In this study, modified NRC-BNL benchmark models were used for seismic analysis. The numerical models include representations of isolation devices. In order to validate the numerical piping system model and to define the failure mode, a quasi-static loading test was conducted on the piping components before the analysis procedures. The fragility analysis was performed by using the results of the inelastic seismic response analysis. Inelastic seismic response analysis was carried out by using the shell finite element model of a piping system considering internal pressure. The implicit method was used for the direct integration time history analysis. In addition, the collapse load point was used for the failure mode for the fragility analysis.

Uncertain-parameter sensitivity of earthquake input energy to base-isolated structure

  • Takewaki, Izuru
    • Structural Engineering and Mechanics
    • /
    • v.20 no.3
    • /
    • pp.347-362
    • /
    • 2005
  • The input energy to a base-isolated (BI) building during an earthquake is considered and formulated in the frequency domain. The frequency-domain approach for input energy computation has some notable advantages over the conventional time-domain approach. Sensitivities of the input energy to the BI building are derived with respect to uncertain parameters in the base-isolation system. It is demonstrated that the input energy can be of a compact form via the frequency integration of the product between the input component (Fourier amplitude spectrum of acceleration) and the structural model component (so-called energy transfer function). With the help of this compact form, it is shown that the formulation of earthquake input energy in the frequency domain is essential for deriving the sensitivities of the input energy to the BI building with respect to uncertain parameters. The sensitivity expressions provide us with information on the most unfavorable combination of the uncertain parameters which leads to the maximum energy input.

Effects of High Damping Rubber Bearing on Horizontal and Vertical Seismic Responses of a Pressurized Water Reactor

  • Bong Yoo;Lee, Jae-Han;Koo, Gyeong-Hoi
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.1021-1026
    • /
    • 1995
  • The seismic responses of a base isolated Pressurized Water Reactor (PWR) are investigated using a mathematical model which expresses the superstructure as lumped mass-spring model and the seismic isolator as an equivalent spring-damper. Time history analyses are performed for the 1940 E1 Centre earthquakes in both horizontal and vertical directions. In the analysis, structural damping of 5% is used for the superstructure. The isolator damping ratios of 12% for horizontal and 5% for vertical directions are used. The acceleration responses in base isolated PWR superstructure with high damping rubber bearings are much smaller than those in fixed base structure in horizontal direction. However, the vertical acceleration responses at the superstructure in the base isolation system are amplified to some extent. It is suggested that the vertical seismic responses at the superstructure should be reduced by introducing a soft vertical isolation device.

  • PDF

Optimum parameters and performance of tuned mass damper-inerter for base-isolated structures

  • Jangid, Radhey Shyam
    • Smart Structures and Systems
    • /
    • v.29 no.4
    • /
    • pp.549-560
    • /
    • 2022
  • The optimum damping and tuning frequency ratio of the tuned mass damper-inerter (TMDI) for the base-isolated structure is obtained using the numerical searching technique under stationary white-noise and filtered white-noise earthquake excitation. The minimization of the isolated structure's mean-square relative displacement and absolute acceleration, as well as the maximization of the energy dissipation index, were chosen as the criteria for optimality. Using a curve-fitting technique, explicit formulae for TMDI damping and tuning frequency for white-noise excitation are then derived. The proposed empirical expressions for TMDI parameters are found to have a negligible error, making them useful for the effective design of base-isolated structures. The effectiveness of TMDI and its optimum parameters are influenced by the soil condition and isolation frequency, according to the comparison made of the optimized parameters and response with different soil profiles. The effectiveness of an optimally designed TMDI in controlling the displacement and acceleration response of the flexible isolated structure under real and pulse-type earthquakes is also observed and found to be increased as the inertance mass ratio increases.

Effect of seismic pounding on buildings isolated by triple friction pendulum bearing

  • Amiri, Gholamreza Ghodrati;Shakouri, Ayoub;Veismoradi, Sajad;Namiranian, Pejman
    • Earthquakes and Structures
    • /
    • v.12 no.1
    • /
    • pp.35-45
    • /
    • 2017
  • The current paper investigates the effect of the seismic pounding of neighboring buildings on the response of structures isolated by Triple Friction Pendulum Bearing (TFPB). To this end, a symmetric three-dimensional single story building is modeled for analysis with two specified levels of top deck and base deck, to capture the seismic response of the base isolators and building's roof. Linear elastic springs with different level of gaps are employed to calculate the impact between the buildings. Nonlinear Dynamic Time History Analyses (NDTHA) are conducted for seismic evaluation. Also, five different sizes with four different sets of friction coefficients are assumed for base isolators to cover a whole range of base isolation systems with various geometry configurations and fundamental period. The results are investigated in terms of base shear, buildings' drift and top deck acceleration of the superstructure. The results also indicate the profound effect of the stiffness of the adjacent buildings on the value of the impact they impose to the superstructure. Also, in situations of potential pounding, the increment of the fundamental period of the TFPB base isolator could intensify the impact force up to nearly five-fold.

Pounding-involved response of isolated and non-isolated buildings under earthquake excitation

  • Mahmoud, Sayed;Jankowski, Robert
    • Earthquakes and Structures
    • /
    • v.1 no.3
    • /
    • pp.231-252
    • /
    • 2010
  • Previous research on pounding between seismically isolated buildings during earthquakes has been focused on impacts at the bases of structures and the effect of simultaneous interactions at the bases and at the superstructures has not been studied in details. In this paper, the seismic responses of adjacent buildings supported on different or similar base systems considering impacts between bases and superstructures are numerically investigated. The study is carried out in three parts for the two types of adjacent buildings: (i) both structures have fixed bases; (ii) one structure has fixed base and the other is seismically isolated and (iii) both structures have base isolation systems. The results of the study indicate that the pounding-involved responses of the buildings depend mainly on the type of structural base systems and on the structural parameters of both buildings. For the base-isolated building, the variation of the peak accelerations and displacements of the storeys have been found to be relatively low. On the other hand, significant differences have been observed for the fixed base building. The results of the parametric study conducted for different values of the gap size between colliding structures show the reduction in the peak base displacements as the gap distance decreases.

Estimation of Equivalent Viscous Damping of Structure with Base Isolation Devices (면진장치를 가지는 구조물의 등가점성감쇠비 산정)

  • 김태호;이동근
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.359-366
    • /
    • 2002
  • Direct Integration method(D.I) and Mode Superposition method(M.S) are used widely in dynamic analysis method for structure with isolation devices. D.I is used firstly because it is consider to nonlinearity of isolation device. M.S is applied in elastic region, but it is difficult to apply M.S because coincidence with othogonality condition in the case of adding the damping of isolation device. In this study, the method for calculation of damping ratio of isolated structure is proposed, and proposed method is verified with analysis for example structure.

  • PDF

Design approach of high damping rubber bearing for seismic isolation

  • Tiong, Patrick L.Y.;Kelly, James M.;Or, Tan T.
    • Smart Structures and Systems
    • /
    • v.20 no.3
    • /
    • pp.303-309
    • /
    • 2017
  • Structural control through seismic isolation using elastomeric rubber bearing, which is also known as High Damping Rubber Bearing (HDRB), has seen an increase in use to provide protective from earthquake, especially for new buildings in earthquake zones. Besides, HDRB has also been used in structural rehabilitation of older yet significant buildings, such as museums and palaces. However, the present design approach applied in normal practice has often resulted in dissimilar HDRB dimension requirement between structural designers and bearing manufacturers mainly due to ineffective communication. Therefore, in order to ease the design process, most HDRB manufacturers have come up with catalogs that list all necessary and relevant product lines specifically for structural engineers to choose from. In fact, these catalogs contain physical dimension, compression property, shear characteristic, and most importantly, the total rubber thickness. Nonetheless, other complicated issues, such as the relationship between target isolation period and displacement demand (which determines the total rubber thickness), are omitted due to cul-de-sac fixing of these values in the catalogs. As such, this paper presents a formula, which is derived and extended from the present design approach, in order to offer a simple guideline for engineers to estimate the required HDRB size. This improved design formula successfully minimizes the discrepancies stumbled upon among structural designers, builders, and rubber bearing manufacturers in terms of variation order issue at the designing stage because manufacturer of isolator is always the last to be appointed in most projects.

Dynamic Response of Seismically Isolated High-Story Buildings according to Earthquake Records (지진기록 사용에 따른 고층 면진건물의 동적 응답)

  • Lee, Hyun-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.5
    • /
    • pp.643-651
    • /
    • 2008
  • The purpose of this study is to evaluate seismic capacity of seismically isolated building according to the earthquake motion record selection method. To analyze the seismic behavior, 20-story building is designed, which has base isolation system. The using earthquake motion record were selected by two categories. The one is a proposed earthquake record according to soil type and response spectrum shape, and the other is a well known earthquake events such as El Centro (1940). The time history analysis results of base isolation buildings be induced difference results according to each ground motion records. Therefore detailed guidelines for the ground motion records selection method must be prepared. And the response of isolation story displacement and shear force show good seismic performance in consideration of the proposed earthquake records.