• Title/Summary/Keyword: Base flow Rate

Search Result 226, Processing Time 0.025 seconds

Development of a Cell-based Long-term Hydrologic Model Using Geographic Information System(I) -Cell-based Long-term Hydrologic Modeling- (지리정보시스템을 이용한 장기유출모형의 개발(I) -장기유출의 격자 모형화-)

  • 최진용;정하우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.1
    • /
    • pp.64-74
    • /
    • 1997
  • A CELTHYM(CEll-based Long-term HYdrologic Model), a pre-processor and a post-processor that can be integrated with geographic information system(GIS) were developed to predict the stream flow from the small agricultural watershed on the daily basis. The CELTHYM calculates the direct runoff from a grid using SCS curve number method and then sum up all of cells with respect to a sub-catchment area belonged to a stream grid and integrated to an outlet. Base flow of a watershed outlet was computed by integrating of the base flow of each stream grid that was averaged the sub-catchment deep-percolation and calculated with the release rate. Two kind of water budget equation were used to compute the water balance in a grid that was classified into not paddy field and paddy field. One of the two equation is a soil water balance equation to account the soil moisture of the upland, forest and excluding paddy field grid. The other is a paddy water balance equation for the paddy field, calculating the ponding depth, the effective rainfall, the deep percolation and the evapotranspiration.

  • PDF

An Experiments Analysis of Comparison of Flow Gradients Across Disposable Arterial Perfusion Cannulas (일회용 각종 송혈관의 관류압차에 대한 비교실험)

  • Kim, Yo-Han;Kim, Hyeong-Muk
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.18-24
    • /
    • 1986
  • The mean perfusion pressure produced by 20 different design and size of disposable aortic perfusion cannulas [size range: 18F to 20F] at flow rates of 1 to 5 L/min was compared. A roller pump with perfusion tubing 10mm in inner diameter was used with a mixture of 0.9% normal saline and 100% glycerin [mixing ratio of 6.72:13.28] to make the viscosity as normal blood in 20oC as the test solution. Line pressure in these cannulas at a flow rate of 3L/min ranged from 13.2$\pm$4.47 to 157$\pm$1 34 mmHg in a case of absence of resistance, and from 11.4$\pm$1.14 to 227.2$\pm$4.47 mmHg in a case of presence of resistances 14 cannulas had gradients of less than 100Hg at a flow rate of 3L/min and 9 cannulas less than 100mmHg at 4L/min. The following results were obtained from this experimental study: .1] A wide range of line pressure was observed in disposable aortic perfusion cannulas currently in clinical use; 2] Some cannulas currently used for cardiopulmonary bypass in adults generated excessive line pressure; 3] Both the material and design affect function, with some designs safer than others. Cardiac surgeons should base the choice of aortic perfusion cannula on the best performance and safest design available to avoid cannula-related problems during operation.

  • PDF

A Study on the Heat Transfer in Radial Fin of Rectangular Profile (사각형(四角形) 단면(斷面)을 가진 반경(半徑)핀에서의 열전달(熱傳達)에 관(關)한 연구(硏究))

  • Kim, Kwang-Soo;Yim, Jang-Soon;Seoh, Jeong-Il
    • Solar Energy
    • /
    • v.2 no.1
    • /
    • pp.24-32
    • /
    • 1982
  • In this paper, temperature distributions in radial fin of rectangular profile for steady-state with no heat generation are obtained by one-dimensional analytical method, finite difference method and experiment respectively. Heat flow rate and fin efficiency from the fin model are obtained by analytical method. Consequently, temperature distributions in radial fin can certify that are similar to exact solution. From theoretical analysis, the effects according to heat flow rate and fin efficiency are related to variation of parameters which are fin thickness ${\delta}_o$, fin base temperature $T_o$, thermal conductivity K with same basic dimensions and the effects are studied and compared.

  • PDF

A Study on the Heat Transfer in Radial Fin of Hyperbolic Profile (쌍곡선 단면을 가진 반경휜에서의 열전달에 관한 연구)

  • Kim, Kwang-Soo;Seoh, Jeong-Il
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.11 no.3
    • /
    • pp.9-17
    • /
    • 1982
  • In this paper, temperature distributions in radial fin of hyperbolic profile for steady -state with no heat generation are obtained by one-dimensional analytical method, finite difference method and experiment respectively. Heat flow rate and fin efficiency from the fin model are obtained by analytical method. To compare the exact solutions obtained by theoretical analysis with the results obtained by finite difference method, cylindrical shape is selected. Particularly, equations of finite difference method for cylindrical shape with irregular boundary are rearranged and formulated. Consequently, temperature distributions in radial fin can certify that are similar to exact solutions. From theoretical analysis, the effects according to heat flow rate and fin efficiency are related to variation of parameters which are fin thickness ${\delta}_o$, fin base temperature $T_o$, thermal conductivity K with same basic dimensions and the fleets are studied and compared.

  • PDF

Heat Exchange Element Made of Plastic for Cooling of Telecommunication Cabinet (통신 함체 냉각용 플라스틱 재질의 열교환 소자)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.702-708
    • /
    • 2017
  • The heat generation rate in a telecommunications cabinet keeps increasing due to the increased usage of mobile devices. Insufficient removal of the heat increases the cabinet temperature, which results in the malfunction of the electronic devices. In this study, tests were conducted on aluminum and plastic heat exchangers for cooling a telecommunications cabinet, and the results were compared with theoretical predictions. The aluminum heat exchanger comprised counter flow parallel channels with 4.5-mm pitch, and the plastic heat exchangers comprised cross or cross-counter flow triangular channels with 2.0-mm pitch. The volume of the cross flow heat exchanger was the same as that of the aluminum heat exchanger, and the volume of the cross-counter heat exchanger was 33% larger than that of the aluminum heat exchanger. The results show that the heat transfer rate is the highest for the cross-counter heat exchanger and lowest for the aluminum one. The temperature efficiency of the cross-counter heat exchanger was 56% higher than that of the aluminum one and 20% higher than that of the cross flow heat exchanger. The pressure drop of the cross-counter heat exchanger was approximately the same as that of the aluminum one. The heat exchange efficiency was the highest for the cross-counter heat exchanger and lowest for the cross flow heat exchanger. The theoretical analysis somewhat overestimated or underestimated the data.

Alternatives for The Stable Operation of Wastewater Treatment Plant in Combined Sewer System during Wet Weather (합류식 하수관거 지역에서 강우시 하수처리장 적정운영방안에 관한 연구)

  • Lee, Doo-jin;Shin, Eung-Bai;Hong, Chul-ui;Ahn, Se-young
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.2
    • /
    • pp.132-144
    • /
    • 2004
  • The purpose of this study was to evaluate alternatives for stable operation of WWTP(Wastewater Treatment Plant) with a higher rate of inflows and a higher concentration of pollutants during wet weather to minimize the pollution loads being discharged into receiving waters. 3Q(Q: dry weather flow) of a base flow is normally intercepted and flows into WWTP as it was current practice. It is revealed by simulation that the bypassing alternative of 1Q through secondary treatment and 2Q into the stream after primary treatment was as good as it is expected. The bypass pollution loads were in the range of 23.9 ~ 38.5 % of the total loads flowing into the WWTP indicating that the bypassed flows need an extra treatment such as stormwater detention reservoir, high-rate coagulation with sedimentation, and step-feed. The high-rate coagulation with sedimentation was the most effective with respect to removal of the pollution loads.

An Adaptive Proportional Integral Active Queue Management Algorithm based on Self-Similar Traffic Rate Estimation in WSN

  • Liu, Heng;Wang, Yan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.11
    • /
    • pp.1946-1958
    • /
    • 2011
  • Wireless Sensor Network (WSN) is made up of a number of sensor nodes and base stations. Traffic flow in WSN appears self-similar due to its data delivery process, and this impacts queue length greatly and makes queuing delay worse. Active queue management can be designed to improve QoS performance for WSN. In this paper, we propose self-similar traffic rate estimating algorithm named Power-Law Moving Averaging (PLMA) to regulate packet marking probability. This algorithm improves the availability of the rate estimation algorithm under the self-similar traffic condition. Then, we propose an adaptive Proportional Integral algorithm (SSPI) based on the estimation of the Self-Similar traffic rate by PLMA. Simulation results show that SSPI can achieve lower queue length jitter and smaller setting time than PI.

Controlled growth of Carbon Nanotubes using thermal CVD

  • Lee, Tae-Jae;Lyu, Seung-Chul;Choi, Sang-Kyu;Lee, Cheol-Jin;Lee, Jin-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.674-677
    • /
    • 2002
  • Vertically aligned CNTs were grown on Fe-deposited $SiO_2$ substrates using thermal CVD of acetylene gas. The size of Fe particle is controlled by the flow rate of $NH_3$ and pretreatment time, which leads to control the diameter of CNTs. As the diameter of CNTs decreases, the growth rate is enhanced with an inverse dependence of the CNT diameter. The growth rate of CNTs increases linearly as the growth time increases until 30 min but is rapidly decreased over 40 min. We found an inverse relation between the diameter and growth rate of carbon nanotubes. As the diameter of CNTs increases, the compartment layers of bamboo-shaped CNTs appear more frequently. A base-growth model is suitable to explain the dependence of growth rate and structure of CNTs on the diameter size of catalytic particles.

  • PDF

Comparative Study on the Effectiveness of Pilocarpine in Xerostomia according to the Method of Administration (필로카핀 투여 방법에 따른 구강 건조증 환자의 치료 효과에 관한 연구)

  • Sun-Kyung Lee;Ki-Yong Hyun;Sung-Woo Lee
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.2
    • /
    • pp.25-45
    • /
    • 1994
  • The purposes of this study were to investigate the effect of pilocarpine-containing chewing gum for the treatment of xerostomia and to compare the effect of pilocarpine-containing chewing gum with that of pilocarpine oral administration. The 20 subjective and objective xerostomic patients were included in this study and divided into 3 groups. Five subjects were included in gum base chewing group, 10 in pilocarpine-containing gum chewing, and 5 in pilocarpine oral administration. The author measured unstimulated whole salivary flow rate, stimulated parotid salivary flow rate, pH of resting whole saliva, viscosity of stimulated whole saliva, and subjective symptoms and discomforts using VAS(visual analogue scale) at the beginning of the experiment. And the author investigated the changes of these factors at 1, 2, 3, and 4 week after. The obtained results were as follows : 1. There were significant increases in the unstimulated whole salivary flow rate in pilocarpine-containing gum chewing and pilocarpine oral administration groups. But there was no significant difference between pilocarpine-containing gum chewing and pilocarpine oral administration groups. 2. There was a significant increase in the stimulated parotid salivary flow rate in pilocarpine- containing gum chewing group. But there was no significant difference between pilocarpine- containing gum chewing and pilocarpine oral administration groups. 3. The change of salivary pH showed the increasing pattern in all groups. But there was no significant difference among groups. 4. There were no significant changes in the values of salivary viscosity in all groups through the experimental period. 5. There were significant decreases of VAS(visual analogue scale) in the degree of subjective symptoms and discomforts in pilocarpine-containing gum chewing and pilocarpine oral administration groups. But there was no significant difference between pilocarpine- containing gum chewing and pilocarpine oral administration groups.

  • PDF

Analytical Study on Unsteady Flow Characteristics of Urea-SCR Single Hole Injector depend on Nozzle Shape Change (Urea-SCR 단홀 Injector 노즐형상 변화에 따른 비정상유동특성의 해석적 연구)

  • Hwang, Jun Hwan;Park, Sung-Young
    • Journal of ILASS-Korea
    • /
    • v.24 no.3
    • /
    • pp.105-113
    • /
    • 2019
  • In this paper, a study of Urea-SCR System for Dosing Injector for responding to enhanced environmental regulations has been conducted. There is a limit to the experimental approach due to the structural characteristics of the injector. In order to overcome this problem, The analysis was performed assuming unsteady turbulent flow through computational fluid analysis and the internal flow characteristics of the injector were analyzed. By changing the nozzle shape of the injector, the performance factors of the swirl injector by shape were selected and compared. The design parameters were modified by changing the diameter of the nozzle at a constant ratio compared to the base model. Swirl coefficient, outlet mass flow, and sac volume were selected as performance parameters of the injector. The Conv. model to which the taper was applied showed the dominance in mass flow rate, discharge coefficient and swirl because of the smooth fluid flow by shape. Swirl coefficient, outlet mass flow, and sac volume were selected as performance parameters of the injector. As a result of the comparison coefficient derivation with those performance parameters for comparing the performance of the model-specific injector, the Conv-140 model with the nozzle diameter expanded by 140% showed the best value of the comparison coefficient.