• 제목/요약/키워드: Base Isolation Bearing

검색결과 115건 처리시간 0.023초

Effects of thermal aging on mechanical properties of laminated lead and natural rubber bearing

  • Kim, Dookie;Oh, Ju;Do, Jeongyun;Park, Jinyoung
    • Earthquakes and Structures
    • /
    • 제6권2호
    • /
    • pp.127-140
    • /
    • 2014
  • Laminated rubber bearing is very popular base isolation of earthquake engineering pertaining to the passive structural vibration control technologies. Rubber used in fabricating NRB and LRB can be easily attacked by various environmental factors such as oxygen, heat, light, dynamic strain, and organic liquids. Among these factors, this study carried out thermal aging test to investigate the effect of thermal aging on the mechanical properties of laminated rubber bearings in accelerated exposure condition of $70^{\circ}C$ temperature for 168 hours. The compressive-shear test was carried out to identify the variation of compressive and shear properties of the rubber bearings before and after thermal aging. In contrast to tensile strength and elongation tests, the hardness of rubber materials showed the increasing tendency dependent on exposure temperature and period. Based on the test results, the property changes of rubber bearing mainly aged by heat are quantitatively presented.

Comparing the dynamic behavior of a hospital-type structure with fixed and isolated base

  • Nasery, Mohammad Manzoor;Ergun, Mustafa;Ates, Sevket;Husem, Metin
    • Earthquakes and Structures
    • /
    • 제9권3호
    • /
    • pp.657-671
    • /
    • 2015
  • The level of ductility is determined by depending on the intended use of the building, the region's seismic characteristics and the type of structural system when buildings are planned by engineers. Major portion of seismic energy is intended to be consumed in the plastic zone in structural systems of high ductility, so the occurrence of damages in load bearing and non-load bearing structural elements is accepted in planning stage under severe earthquakes. However, these damages must be limited among specific values in order not to endanger buildings in terms of the bearing capacity. Isolators placed between the basement and upper structure make buildings behave elastically by reducing the effects of seismic loads and improving seismic performance of building significantly. Thus, damages can be limited among desired values. In this study, the effectiveness of seismic isolation is investigated on both fixed based and seismic isolated models of a hospital building with high ductility level with regard to lateral displacements, internal forces, structural periods and cost of the building. Layered rubber bearings are interposed between the base of the structure and foundation. Earthquake analysis of the building are performed using earthquake records in time domain (Kocaeli, Loma Prieta and Landers). Results obtained from three-dimensional finite element models are presented by graphs and tables in detail. That seismic isolation reduces significantly the destructive effects of earthquakes on structures is seen from the results obtained by seismic analysis.

자동복원 및 보강 시스템과 결합된 면진받침의 지진거동과 평가 (Seismic Behavior and Estimation for Base Isolator Bearings with Self-centering and Reinforcing Systems)

  • 허종완
    • 대한토목학회논문집
    • /
    • 제35권5호
    • /
    • pp.1025-1037
    • /
    • 2015
  • 지반과 상부 구조물 사이의 경계에서 유연성이 확보된 지진동 격리 받침 시스템을 설치한 후에 전체 구조물의 고유 주기를 연장하고 구조물에 전달되는 지진 가속도를 저감하여 구조물을 보호하는 면진 설계 방식이 최근 건설 현장에서 널리 활용되고 있다. 하지만 도심지의 현대 구조물이 점차 대형화 및 고층화 되면서 기존의 면진 받침을 그대로 사용하기에는 지진 발생시 저항 능력의 부족으로 인한 전단파괴 혹은 잔류변형이 발생하여 구조물의 사용성 향상을 위한 보수 및 붕괴 위험에 따른 철거의 문제점을 발생시킨다. 따라서 본 연구에서는 기존에 주로 사용되는 면진 받침의 저항 강도와 복원성을 향상시키기 위하여 부가적인 개장 시스템을 설치하고 지진 하중에 대한 성능을 평가하고자 한다. 초탄성 형상기억합금 소재의 보강 봉을 납 적층 고무 받침에 설치한 면진 시스템을 설계하고 단자유도 스프링 모델로 모형화하여 지진 데이터를 활용하고 비선형 동적 해석을 실시하였다. 본 연구에서 제안된 면진 시스템이 성능적인 우수성을 입증하기 위하여 기존에 사용된 면진 받침과 여기에 추가로 강재 봉으로 보강된 면진 시스템과의 극한 전단 저항력, 복원성 및 잔류변형 발생 등을 해석을 통하여 비교 평가하였다. 그 결과 초탄성 형상기억합금 소재의 제어 봉으로 보강된 면진 받침이 다른 면진 받침과 비교하여 지진저항 성능에 있어서 우수함을 확인하였다.

지진시 저층건물 면진구조의 비선형 동적 거동 (Dynamic Stability Analysis of Base-Isolated Low-level Nonlinear Structure Under Earthquake Excitation)

  • 문병영;강경주;강범수;김계수
    • 대한기계학회논문집A
    • /
    • 제25권11호
    • /
    • pp.1743-1750
    • /
    • 2001
  • This paper presents an analysis of nonlinear response of the seismically isolated structure against earthquake excitation to evaluate isolation performances of a rubber bearing. In the analysis of the vibration of building, the building is modeled by lumped mass system where the restoring force is considered as linear, bilinear and trilinear. Fundamental equations of motion are derived for the base isolated structure, and hysteretic and nonlinear-elastic characteristics are considered for a numerical calculation. The excitation levels are magnified fur the recorded strong earthquake motions in order to examine dynamic stability of the structure. Seismic responses (of the building are compared fur the each restoring force type. As a result, it is shown that the effect of the motion by the nonlinear response of the building is comparatively not so large from a seismic design standpoint. The responses of the isolated structures reduce sufficiently and controled the motion of the building well in a practical range. By increasing the acceleration of the earthquake, the yielding of the farce was occurred in the concrete and steel frame, which shows the necessity of the exact nonlinear dynamic analysis.

마찰진자 베어링의 동적 특성평가 (Dynamic Property Evaluation of Friction Pendulum Isolation Bearing)

  • 이경진;김갑순;서용표
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.465-472
    • /
    • 2003
  • The main concept of base isolation system is to reduce the member forces by decreasing the earthquake forces transmitted to superstructure instead of the conventional techniques of strengthening the structural members. There are two important advantages in friction pendulum systems. The functions of carrying the vertical load and of providing horizontal stiffness are effectively separated. This results in a more stable system that eliminates the need of a fail-safe mechanism. Friction pendulum systems are less sensitive to variations in the frequency content of ground excitation and tend to limit the intensity of the farce imparted to the superstructure. This study investigates the friction coefficients on the FPS test specimens according to the velocity, bearing pressure and test waveform.

  • PDF

Base isolation performance of a cone-type friction pendulum bearing system

  • Jeon, Bub-Gyu;Chang, Sung-Jin;Kim, Sung-Wan;Kim, Nam-Sik
    • Structural Engineering and Mechanics
    • /
    • 제53권2호
    • /
    • pp.227-248
    • /
    • 2015
  • A CFPBS (Cone-type Friction Pendulum Bearing System) was developed to control the acceleration delivered to a structure to prevent the damage and degradation of critical communication equipment during earthquakes. This study evaluated the isolation performance of the CFPBS by numerical analysis. The CFPBS was manufactured in the shape of a cone differenced with the existing FPS (Friction Pendulum System), and a pattern was engraved on the friction surface. The natural frequencies of the CFPBS were evaluated from a free-vibration test with a seismic isolator system consisting of 4 CFPBS. To confirm the earthquake-resistant performance, a numerical analysis program was prepared using the equation of the CFPBS induced from the equations of motion. The equation reported by Tsai for the rolling-type seismic isolation bearings was proposed to design the equation of the CFPBS. Artificial seismic waves that satisfy the maximum earthquake scale of the Korean Building Code-Structural (KBC-2005) were created and verified to review the earthquake-resistant performance of the CFPBS by numerical analysis. The superstructural mass of the CFPBS and the skew angle of friction surface were considered for numerical analysis with El Centro NS, Kobe NS and artificial seismic waves. The CFPBS isolation performance evaluation was based on the numerical analysis results, and comparative analysis was performed between the results from numerical analysis and simplified theoretical equation under the same conditions. The validity of numerical analysis was verified from the shaking table test.

Reliability-based design of semi-rigidly connected base-isolated buildings subjected to stochastic near-fault excitations

  • Hadidi, Ali;Azar, Bahman Farahmand;Rafiee, Amin
    • Earthquakes and Structures
    • /
    • 제11권4호
    • /
    • pp.701-721
    • /
    • 2016
  • Base isolation is a well-established passive strategy for seismic response control of buildings. In this paper, an efficient framework is proposed for reliability-based design optimization (RBDO) of isolated buildings subjected to uncertain earthquakes. The framework uses reduced function evaluations method, as an efficient tool for structural reliability analysis, and an efficient optimization algorithm for optimal structural design. The probability of failure is calculated considering excessive base displacement, superstructure inter-storey drifts, member stress ratios and absolute accelerations of floors of the isolated building as failure events. The behavior of rubber bearing isolators is modeled using nonlinear hysteretic model and the variability of future earthquakes is modeled by applying a probabilistic approach. The effects of pulse component of stochastic near-fault ground motions, fixity-factor of semi-rigid beam-to-column connections, values of isolator parameters, earthquake magnitude and epicentral distance on the performance and safety of semi-rigidly connected base-isolated steel framed buildings are studied. Suitable RBDO examples are solved to illustrate the results of investigations.

Seismic protection of LNG tanks with reliability based optimally designed combined rubber isolator and friction damper

  • Khansefid, Ali;Maghsoudi-Barmi, Ali;Khaloo, Alireza
    • Earthquakes and Structures
    • /
    • 제16권5호
    • /
    • pp.523-532
    • /
    • 2019
  • Different types of gas reservoir such as Liquid Natural Gas (LNG) are among the strategic infrastructures, and have great importance for any government or their private owners. To keep the tank and its contents safe during earthquakes especially if the contents are of hazardous or flammable materials; using seismic protection systems such as base isolator can be considered as an effective solution. However, the major deficiency of this system can be the large deformation in the isolation level which may lead to the failure of bearing system. In this paper, as a solution, the efficacy of an optimally designed combined vibration control system, the combined laminated rubber isolator and rotational friction damper, is investigated to evaluate the enhancement of an existing metal tank response under both far- and near-field earthquakes. Responses like impulsive and convective accelerations, base shear, and sloshing height are studied herein. The probabilistic framework is used to consider the uncertainties in the structural modeling, as well as record-to-record variability. Due to the high calculation cost of probabilistic methods, a simplified structural model is used. By using the Mont-Carlo simulation approach, it is revealed that this combined isolation system is a highly reliable system which provides considerable enhancement in the performance of reservoir, not only leads to the reduction of probability of catastrophic failure of the tank but also decrease the reservoir damage during the earthquake. Moreover, the relative displacement of the isolation level is controlled very well by this combined system.

사장교를 위한 LRB-기반 복합 기초격리 시스템 (LRB-based hybrid base isolation systems for cable-stayed bridges)

  • 정형조;박규식;;이인원
    • 한국지진공학회논문집
    • /
    • 제8권3호
    • /
    • pp.63-76
    • /
    • 2004
  • 사장교에 발생하는 지진에 의한 진동을 감소시키기 위해 추가적인 능동/반능동 제어장치를 부착한 LRB-기반 복합 기초격리 시스템에 대한 논문이다. 복합 기초격리 시스템은 제어장치가 다중으로 작동하기 때문에 LRB가 설치된 교량 시스템과 같은 수동형 기초격리 시스템에 비해 제어 성능이 뛰어나다. 본 논문에서는, LQG 알고리듬에 의해 제어되는 능동형 유압식 가력기와 clipped 최적제어에 의해 제어되는 반능동형 자기유변 유체 (MR) 감쇠기를 추가적인 제어장치로 고려하여 추가적인 응답 감소 효과를 검토하였다. 이를 위해, 미국토목학회의 1단계 벤치마크 사장교에 LRB를 설치한 교량을 고려하였다. 수치해석 결과를 통해, 모든 LRB-기반 복합 기초격리시스템이 구조물의 응답을 효과적으로 감소시킴을 확인하였다. 또한, MR 감쇠기를 채택한 복합 기초격리 시스템은 구조물 강성의 불확실성에 대해 강인성을 보였지만 유압식 가력기를 채택한 경우에는 강인성이 부족함을 알 수 있었다. 따라서, 반능동형 추가 제어장치를 채택한 복합 기초격리 시스템의 대형 토목구조물에 대한 적용가능성이 제어 성능 및 강인성 면에서 분명하게 검증되었다.

고무 면진 베어링 몰딩과정의 열전달 해석 및 실험 (An Experimental Study of Heat Transfer Analysis in Molding the Rubber Bearing for Seismic Isolator)

  • 강경주;문병영;강범수;김계수;정경수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집C
    • /
    • pp.275-280
    • /
    • 2001
  • Seismic isolator system is one of the most widely used base isolation system in order to control the vibration of structure against earthquake excitation. The evaluation of vulcanization time in molding the rubber bearing is very important for both proper ability of isolator and efficiency of manufacture. This paper deals with experimental measurement of temperature of isolator with senor inside in it, and compared with the result of FEA in order to evaluate the vulcanization time. Properties of rubber bearing which is used in the FEA are obtained by controlling the specific heat of rubber. With the obtained properties of rubber, the isolator is analysed by FEA. As a result, an appropriate analytical vulcanization time is obtained. This time is regarded as an appropriate temperature, which is used to effective manufacture.

  • PDF