Centrifuge shaking table tests on a friction pendulum bearing isolated structure with a pile foundation in soft soil

  • Shu-Sheng, Qu;Yu, Chen;Yang, Lv
    • Earthquakes and Structures
    • /
    • 제23권6호
    • /
    • pp.517-526
    • /
    • 2022
  • Previous studies have shown that pile-soil interactions have significant influences on the isolation efficiency of an isolated structure. However, most of the existing tests were carried out using a 1-g shaking table, which cannot reproduce the soil stresses resulting in distortion of the simulated pile-soil interactions. In this study, a centrifuge shaking table modelling of the seismic responses of a friction pendulum bearing isolated structure with a pile foundation under earthquakes were conducted. The pile foundation structure was designed and constructed with a scale factor of 1:100. Two layers of the foundation soil, i.e., the bottom layer was made of plaster and the upper layer was normal soil, were carefully prepared to meet the similitude requirement. Seismic responses, including strains, displacement, acceleration, and soil pressure were collected. The settlement of the soil, sliding of the isolator, dynamic amplification factor and bending moment of the piles were analysed to reveal the influence of the soil structure interaction on the seismic performance of the structure. It is found that the soil rotates significantly under earthquake motions and the peak rotation is about 0.021 degree under 24.0 g motions. The isolator cannot return to the initial position after the tests because of the unrecoverable deformation of the soil and the friction between the curved surface of the slider and the concave plate.

수평 전단시험에 의한 납 삽입 적층고무베어링의 기계적 특성 평가 (Mechanical Characterization of Lead-Rubber Bearing by Horizontal Shear Tests)

  • 전영선;최인길;유문식
    • 한국지진공학회논문집
    • /
    • 제5권6호
    • /
    • pp.1-10
    • /
    • 2001
  • 본 연구에서는 수평전단시험을 통하여 LRB(lead-rubber hearing)의 동적 특성을 분석하였다. 10ton 및 200ton 용량의 LRB를 이용하여 수평전단시험을 수행한 결과 LRB의 동적 특성은 수평하중의 재하속도, 연직하중의 크기 및 전단변형률 등에 따라 크게 달라지는 것으로 나타났다. 세장비가 큰 면진장치에 과도한 변형을 가할 경우 내부 납심에 소성한지가 발생되어 납심이 파괴되는 것으로 나타났다. 따라서 면진구조물의 설계 및 해석 시에는 지진응답과 재하하중의 크기에 따라서 달라지는 LRB의 기계적 특성치를 적용하여 안전한 설계가 이루어질 수 있도록 하여야 한다.

  • PDF

탄성마찰포트받침을 적용한 교량의 내진성능에 관한연구 (A Study on Aseismatic Performance of Base Isolation Systems Using Resilient Friction Pot Bearing)

  • 오주;현기환;박연수;박성규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.127-134
    • /
    • 2008
  • 내진설계기준이 점차 강화되고 다경간 연속화에 대한 시도가 증가됨에 따라 기존의 내진설계로는 지진력의 처리가 곤란하여 다점고정장치와 감쇠를 통해 지진에너지를 소산시키는 장주기화, 분산, 감쇠를 통해 지진력을 효과적으로 감소시키는 면진장치의 사용이 날로 증가하고 있다. 그러나 내진장치 적용에 대한 다양성 부재와 장치를 적용한 설계경험의 부족 등의 이유로 특정교량에 적절한 내진장치를 선정하는데 상당한 어려움이 따르고 있다. 따라서 본 연구에서는 다양한 내진장치가 적용된 교량의 지진시 거동특성에 대한 연구를 수행하여 받침장치 선정시 활용할 수 있도록 하였다.

사장교의 지진 응답 제어를 위한 납고무 받침의 설계 기준 제안 (Guidelines of Designing Lead Rubber Bearing for a Cable-Stayed Bridge In Control Seismic Response)

  • 이성진;박규식;김춘호;이인원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.509-516
    • /
    • 2003
  • In tile design of base isolation system for building and short-span bridge, shift of the natural period of the structure is main objective. But, most long-span bridges such as a cable-stayed bridges have a number of long-period modes due to their flexibility and small structural damping. thus the design concept of base isolation system for building and short-span brigde may be difficult to use directly to these structures. However, the effectiveness of LRB for cable-stayed bridges is indicated by Ali and Abdel-Ghaffar. In this study, the design procedure and guidelines of LRB for a seismically excited cable-stayed bridge are investigated. The design properties of LRB are chosen that the design index(DI) is minimized or little changed for variation of properties. This result show that the stiffer rubber and bigger lead core size are need to cable-stayed bridges. And the seismic performance of designed LRB is also investigated. The consequences show that the perforamnce of designed LRB is better than that of Naeim-Kelly mettled designning LRB for general building structures. Moreover, the design properties of LRB are researched to several diffrent dominant frequency of earthquake. The results present that the plastic and elastic stiffness of LRB are affected by the dominant frequency of earthquake.

  • PDF

교량용 내진 받침의 동특성 실험 결과를 이용한 교량의 해석 (Dynamic Analysis far Bridge Using the Experimental Results of Hysteretic Damping Bearing and Dynapot)

  • 박동욱;윤정방;이인원;강용우;손만길
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.320-328
    • /
    • 2001
  • Base Isolation system is an effective design strategy that provides a practical substitute for the seismic design of bridge. In this study, the dynamic tests were performed on two kinds of aseismic bridge bearings : Hydampot (hysteretic damping bearing) and Dynapot . Then, the dynamic analysis was carried out far a bridge using the experimental results to estimate the seismic performance of the bearings. Analysis was performed for four types oi earthquake loadings. The results of the dynamic test and theoretical analysis indicate that the performance of both bridge bearings is appropriate fur the earthquake loading.

  • PDF

A SEISMIC DESIGN OF NUCLEAR REACTOR BUILDING STRUCTURES APPLYING SEISMIC ISOLATION SYSTEM IN A HIGH SEISMICITY REGION -A FEASIBILITY CASE STUDY IN JAPAN

  • Kubo, Tetsuo;Yamamoto, Tomofumi;Sato, Kunihiko;Jimbo, Masakazu;Imaoka, Tetsuo;Umeki, Yoshito
    • Nuclear Engineering and Technology
    • /
    • 제46권5호
    • /
    • pp.581-594
    • /
    • 2014
  • A feasibility study on the seismic design of nuclear reactor buildings with application of a seismic isolation system is introduced. After the Hyogo-ken Nanbu earthquake in Japan of 1995, seismic isolation technologies have been widely employed for commercial buildings. Having become a mature technology, seismic isolation systems can be applied to NPP facilities in areas of high seismicity. Two reactor buildings are discussed, representing the PWR and BWR buildings in Japan, and the application of seismic isolation systems is discussed. The isolation system employing rubber bearings with a lead plug positioned (LRB) is examined. Through a series of seismic response analyses using the so-named standard design earthquake motions covering the design basis earthquake motions obtained for NPP sites in Japan, the responses of the seismic isolated reactor buildings are evaluated. It is revealed that for the building structures examined herein: (1) the responses of both isolated buildings and isolating LRBs fulfill the specified design criteria; (2) the responses obtained for the isolating LRBs first reach the ultimate condition when intensity of motion is 2.0 to 2.5 times as large as that of the design-basis; and (3) the responses of isolated reactor building fall below the range of the prescribed criteria.

Research on no coal pillar protection technology in a double lane with pre-set isolation wall

  • Liu, Hui;Li, Xuelong;Gao Xin;Long, Kun;Chen, Peng
    • Geomechanics and Engineering
    • /
    • 제27권6호
    • /
    • pp.537-550
    • /
    • 2021
  • There are various technical problems need to be solved in the construction process of pre-setting an isolation wall into a double lane in the outburst prone mine. This study presents a methodology that pre-setting an isolation wall into a double lane without a coal pillar. This requires the excavation of two small section roadways to dig a wide section roadway, followed by construction of the separation wall. During this process the connecting lane is reserved. In order to ensure the stability of the separation wall, the required bearing capacity of the isolation wall is 4.66 MN/m and the deformation of the isolation wall is approximately 25 cm. To reduce the difficulty of implementing support the roadway is driven by 5 m/d. After the construction of the separation wall, the left side coal wall is brushed 1.5 m to make the width of the gas roadway reach 2.5 m and the roadway support utilizes anchor rod, ladder beam, anchor cable beam and net configuration. During construction, the concrete pump and removable self-propelled hydraulic wall mold are used to pump and pour the concrete of the isolation wall. In the process of mining, the stress distribution of coal body and isolation wall is detected and measured on site. The results demonstrate that the deformation of the surrounding rock of roadway and separation of roof in the roadway is small. The stress of the bolt and anchor cable is within equipment tolerance validating their selection. The roadway is well supported and the intended goal is achieved. The methodology can be used for reference for similar mine gas control.

Shape memory alloy (SMA)-based Superelasticity-assisted Slider (SSS): an engineering solution for practical aseismic isolation with advanced materials

  • Narjabadifam, Peyman;Noori, Mohammad;Cardone, Donatello;Eradat, Rasa;Kiani, Mehrdad
    • Smart Structures and Systems
    • /
    • 제26권1호
    • /
    • pp.89-102
    • /
    • 2020
  • Shape memory alloy (SMA)-based Superelasticity-assisted Slider (SSS) is proposed as an engineering solution to practically exploit the well-accepted advantages of both sliding isolation and SMA-based recentering. Self-centering capability in SSS is provided by austenitic SMA cables (or wire ropes), recently attracting a lot of interest and attention in earthquake engineering and seismic isolation. The cables are arranged in various novel and conventional configurations to make SSS versatile for aseismic design and retrofit of structures. All the configurations are detailed with thorough technical drawings. It is shown that SSS is applicable without the need for Isolation Units (IUs). IUs, at the same time, are devised for industrialized applications. The proof-of-concept study is carried out through the examination of mechanical behavior in all the alternative configurations. Force-displacement relations are determined. Isolation capabilities are predicted based on the decreases in seismic demands, estimated by the increases in effective periods and equivalent damping ratios. Restoring forces normalized relative to resisting forces are assessed as the criteria for self-centering capabilities. Lengths of SMA cables required in each configuration are calculated to assess the cost and practicality. Practical implementation is realized by setting up a small-scale IU. The effectiveness of SSS under seismic actions is evaluated using an innovative computer model and compared to those of well-known Isolation Systems (ISs) protecting a reference building. Comparisons show that SSS seems to be an effective IS and suitable for earthquake protection of both structural and non-structural elements. Further research aimed at additional validation of the system are outlined.

Seismic behavior of structures isolated with a hybrid system of rubber bearings

  • Chen, Bo-Jen;Tsai, C.S.;Chung, L.L.;Chiang, Tsu-Cheng
    • Structural Engineering and Mechanics
    • /
    • 제22권6호
    • /
    • pp.761-783
    • /
    • 2006
  • The enlargement of interest in base isolators as an earthquake-proof design strategy has dramatically accelerated experimental studies of elastomeric bearings worldwide. In this paper, a new base isolator concept that is a hybrid system of rubber bearings is proposed. Uniaxial, biaxial, and triaxial shaking table tests are also performed to study the seismic behavior of a 0.4-scale three-story isolated steel structure in the National Center for Research on Earthquake Engineering in Taiwan. Experimental results demonstrate that structures with a hybrid system of rubber bearings composed of stirruped rubber bearings and laminated rubber bearings can actually decrease the seismic responses of the superstructure. It has been proved through the shaking table tests that the proposed hybrid system of rubber bearings is a very promising tool to enhance the seismic resistance of structures. Moreover, it is demonstrated that the proposed analytical model in this paper can predict the mechanical behavior of the hybrid system of rubber bearings and seismic responses of the base-isolated structures.

형상기억합금을 이용한 고속도로 강교량의 면진 (Seismic base isolation for highway steel bridges using shape memory alloys)

  • 최은수;전준창
    • 한국강구조학회 논문집
    • /
    • 제16권1호통권68호
    • /
    • pp.145-153
    • /
    • 2004
  • 기존교량의 내진성능개선 및 신설교량의 지진보호에 납-고무 베어링은 좋은 효과를 보여주고 있다. 그러나 납-고무 베어링은 사용상에 있어 문제점이 있으며, 이를 개선하기 위하여 형상기억합금(shape memory alloy)을 이용한 면진장치를 본 연구에서 제시하였다. 3경간 연속 고속도로 강교량의 지진해석을 통하여 납-고무베어링과 고무베어링 및 형상기억합금 와이어와의 조합 면진장치의 지진거동을 비교하였다. 해석결과 형상기억합금 와이어+고무베어링 시스템이 납-고무베어링과 거의 유사한 거동을 보여주었으며, 특히 제시된 면진장치는 상대변위의 제어 및 잔류변형에 있어 기존의 납-고무 베어링에 비해 성능이 우수했다.