• Title/Summary/Keyword: Barrier filter

Search Result 46, Processing Time 0.026 seconds

Combination of Infrared Light Source and Barrier Filter for Suction Bruise Photography (음압에 의해 생성된 멍 촬영을 위한 적외선 광원과 필터 조합에 관한 연구)

  • Kim, Ju-Eun;Kim, Ji-Yeon;Jeon, So-Young;Kim, Eun-A;Yu, Je-Seol
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.11
    • /
    • pp.693-698
    • /
    • 2016
  • Bruise caused by damages through physical compression and suction is one of evidences that can prove abuse or assault. It is essential for taking photography to prove a crime. Some studies about the Infrared (IR) light source have limitations that only one IR light source and one barrier filter were used. To find the best combination of filters and IR light sources, we produced suction bruise artificially and used three IR light sources and five barrier filters. Consequently, we found that the best combination is using a tungsten lamp and Kodak Wratten #18A barrier filter.

Collision CFD Analysis of Noise Barrier of Road-Generated Particulate (도로 발생 분진의 방음벽 충돌 CFD 분석)

  • Lee, Jaiyeop;Kim, Ilho
    • International Journal of Highway Engineering
    • /
    • v.19 no.6
    • /
    • pp.31-36
    • /
    • 2017
  • PURPOSES : The computational fluid dynamics of flow and fine particles in a road were set to determine the insert flow and occurrence characteristics. METHODS : The road extension was 100 m with two lanes. A one-ton truck traveled a 50-m distance. After a noise barrier was installed on one side of the road, the flow and a collision analysis were tested. RESULTS : The flow that occurred was 5 m/s beside the vehicle, and fine particulate was $5.0{\times}10^2{\mu}g/m^3$ after 20 m from the exhaust vent. CONCLUSIONS : After a collision analysis of the fine particulate on the noise barrier to find the most suitable position of the filter panel in height, the bottom 1 m was the most optimum position because 88.1% of the distribution was concentrated there.

A study on nanoparticle filtration characteristics of multilayer meltblown depth filters

  • Lee, Kang-San;Hasolli, Naim;Jeon, Seong-Min;Lee, Jae-Rang;Kim, Kwang-Deuk;Park, Young-Ok;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.12 no.3
    • /
    • pp.51-56
    • /
    • 2016
  • Due to recent development in nanotechnology and increasing usage and production of nanomaterials, numerous studies related to environment, sanitation and safety handling of nanoparticle are being conducted. Since nanoparticles can be easily absorbed into human bodies through breathing process, based on their toxic substances and their large specific surface, these particles can cause serious health damage. Therefore, to reduce nanoparticle emissions, nanofiltration technology is becoming a serious issue. Filtration is a separation process during which a fluid passes through a barrier by removing the particles from the stream. Barrier filters can be made of various materials and shapes. One of the most common type of barrier filter is the fibrous filter. Fibrous filters are divided in two types: nonwoven and woven fabrics. Polypropylene is a thermoplastic material, used as a base material for melt blown nonwoven fabric. In this study, we examined filtration property of KCl nanoparticles with a mean particle diameter of 75 nm using multilayer meltblown filter samples. These experiments verify that the penetration of nanoparticle in the filter correlate with pressure drop; the meltblown layer MB1 has the greatest effect on dust collection efficiency of the filter. Among all tested samples, dust collection efficiency of 2-layer filter was best. However, when considering the overall pressure drop and dust collection efficiency, the 4-layer filter has the highest quality factor for particles smaller than 70 nm.

Inactivation of Ralstonia Solanacearum using Filtration-Plasma Process (여과-Plasma 공정을 이용한 Ralstonia Solanacearum 불활성화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.23 no.6
    • /
    • pp.1165-1173
    • /
    • 2014
  • For the field application of dielectric barrier discharge plasma reactor in nutrient solution culture, a filtration-DBD (dielectric barrier discharge) plasma reactor was investigated for the Ralstonia solanacearum which causes bacterial wilt in aquiculture. The filtration-DBD plasma reactor system of this study was consisted of filter, plasma reactor, reservoir. The DBD plasma reactor consisted of a quartz dielectric tube, discharge electrode (inner) and ground electrode (outer). The experimental results showed that the inactivation of R. solanacearum with filter media type in filter reactor ranked in the following order: anthracite > fiber ball > sand > ceramic ball > quartz ceramic. In filtration + plasma process, disinfection effect with the voltage was found to small. In disinfection time of 120 minutes, residual R. solanacearum concentration was 1.17 log (15 CFU/mL). When the continuous disinfection time was 120 minute, disinfection effect was thought to keep the four days. In sporadic operation mode of 30 minutes disinfection - 24 hours break, residual R. solanacearum concentration after five days was 0.3 log (2 CFU/mL). It is considered that most of R. solanacearum has been inactivated substantially.

Interface Engineering in Quasi-Magnetic Tunnel Junctions with an Organic Barrier

  • Choi, Deung-Jang;Lee, Nyun-Jong;Kim, Tae-Hee
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.185-189
    • /
    • 2010
  • Spin polarized tunneling through a hybrid tunnel barrier of a Spin filter (SF) based on a EuO ferro-magnetic semiconductor and an organic semiconductor (OSC) (rubrene in this case) was investigated. For quasi-magnetic tunnel junction (MTJ) structures, such as Co/rubrene/EuO/Al, we observed a strong spin filtering effect of the EuO layer exhibiting I-V curves with high spin polarization (P) of up to 99% measured at 4 K. However, a magnetoresistance (MR) value of 9% was obtained at 4.2 K. The low MR compared to the high P could be attributed to spin scattering caused by structural defects at the interface between the EuO and rubrene, due to nonstoichiometry in the EuO.

Evaluation of Filter Capacity for Sea Dyke Slope Filter Layer by In-situ Rainfall Test (현장 강우재현시험을 통한 방조제 사면필터층의 필터성능분석)

  • Oh, Young-In;Kim, Seo-Ryong;Yoo, Jeon-Yong;Kim, Hyun-Tae
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.828-837
    • /
    • 2006
  • Geotextiles consist of three major types of geosynthetic material (woven, non-woven and composite) and the functions of geotextiles are separation, reinforcement, filtration, drainage and as a moisture barrier. Although the many research scholar and engineer developed and established the design criteria and construction methodology, sustainable research still needed for optimum design methodology to the complicate field conditions. In this study, in-situ rainfall test performed to develop suitable filter system for sea dyke upper slope filter layer. In-situ rainfall test conducted for seven different filter system and measured the infiltration flux and pore pressure at various filter layer. Based on the test results, the double layered geotextile filter and sand transition system is most suitable for sea dyke upper filter layer because which system is effective for drainage of infiltration flow and minimize the deformation of sea dyke cover stone.

  • PDF

A laboratory study on synthetic fiber filter for further treatment of turbid stormwater from construction sites

  • Yuan, Qingke;Kim, Youngchul
    • Membrane and Water Treatment
    • /
    • v.10 no.2
    • /
    • pp.105-112
    • /
    • 2019
  • On the purpose of conform the more stringent government regulation for turbid stormwater from construction sites, the feasibility and availability of synthetic fiber placing after the conventional protection barrier were tested in this study. Initially, comparative work on the filtering performance of fiber media and conventional gravel filter was carried out, 27% higher filtration capacity was obtained under the similar operational conditions. The filter efficiency was about 20 to 52% with a varying filter depth of 5 to 15cm, presuming at extreme storm flow conditions (800-1500 m/day of filtration rates). Fiber filter was found to have a similar filtration prosperity as grain media; namely, the separation efficiency is directly and inversely proportional to filter depth and rate, respectively. The effects of filter aid (polyaluminium chloride) on filter performance was also investigated, it greatly affected the turbidity reduction at the dosage of 2 mg/L. At the time of breakthrough, a simple filter washing was carried out, herein, the solid recovery achieved over than 88% and greatly determined by operational parameters. Based on the operational data, the empirical models aimed for predicting filtration efficiency were established, which can effectively determine the required filter depth and filtration area in field.

A Highly Efficient Rectenna Using Harmonic Rejection Capability

  • Kim, Youg-Hwan;Lim, Sung-Joon
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.4
    • /
    • pp.257-261
    • /
    • 2011
  • A highly efficient 2.4 GHz rectenna is designed using a harmonic rejection bandpass filter. The rectenna is printed on Rogers Duroid 5880 substrate with ${\varepsilon}_r$=2.2 and a thickness of 1.6 mm. The rectenna consists of a microstrip antenna and high order harmonic rejection bandpass filter, microstrip lowpass filter, and Schottky barrier diode (HSMS2820). The use of a $2^{nd}$ and $3^{rd}$ harmonic rejection microstrip bandpass filter in the rectenna results in high conversion efficiency. The proposed rectenna achieves a RF to DC conversion efficiency of 72.17 % when the received RF power is 63.09 mW.

Non-Causal Filter의 PC-NC에의 응용

  • 장현상;최종률
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.1039-1042
    • /
    • 1995
  • In real time application such as motion control, it is hard to find the application of non-causal filtering due to its need for future position data, even though it shows wide usage in off-line digital signal processing. Recently, some of motion control areas such as learning and repetitive control use non-causal filtering technique in their application. these kinds of zero-lag non-causal filter application are very usful not only to reduce the machine vibration, but also to increase control accuracy with comparatively less work. In this paper, genuine method to implement zero-lag non-causal filter in a CNC is introduced. Also the variation of this implementation for the learning operation is suggested to give the NC better control performance for a specific job. By adopting the new NC architecture call Soft-NC, all these implementions are made possible here, and especially large memory requirement which hinders their usage for many years is no longer barrier in their real world application.

  • PDF