• Title/Summary/Keyword: Banwol-Sihwa industrial complex

Search Result 14, Processing Time 0.039 seconds

The Concentrations of Sulfur Compounds and Sensation of Odor in the Residential Area Around Banwol-Sihwa Industrial Complex (반월.시화공단 주변 주거지역의 악취현황 및 황화합물의 체감도)

  • Kim, Jong-Bo;Jeong, Sang-Jin;Song, Il-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.2
    • /
    • pp.147-157
    • /
    • 2007
  • This study was carried out to investigate the characteristics of fourteen odor compounds from a total of 10 sampling sites in residential areas around Banwol-Sihwa industrial complex. The measurement data are analyzed and compared with sensation of odor unit. Only a hydrogen sulfide out of four sulfur compounds was quantified above the detection limit (0.06 ppb) in the residential area around Banwol industrial complex with leather companies and a sewage treatment plant. The concentrations of VOCs were higher than those measured from a big city, and styrene showed the relatively high concentration from all sampling sites ($2.1{\sim}37.8\;ppb$). In the case of carbonyl compounds, acetaldehyde was found most frequently with the mean of 3.97 ppb, and its concentration difference was not significant between Banwol and Sihwa industrial complex. Of the nitrogen compounds, ammonia was measured at the relatively high concentration from all the sampling sites ($12{\sim}707\;ppb$), and a trimethylamine was found at the odor threshold level (0.1 ppb). The concentrations of styrene and ammonia showed relatively seasonal variation, the concentration of styrene in summer was five times higher than that in autumn, the concentration of ammonia in autumn was two times higher than that in summer. However other odorous compounds did not show such strong seasonal variation. Odor-concentration relationship between odor unit and $H_{2}S$ concentrations from industrial sources was examined and used as odor sensation evaluation, and thus the neighbourhood odor complaints maybe caused during the four seasons from the results.

A Study on the Atmospheric Dispersion of Odor Emitted from Banwol/Sihwa Industrial Complex in Ansan Area (반월, 시화공단 악취물질의 안산지역 확산 연구)

  • Song, Dong-Woong;Song, Chang-Keun;Kim, Cheol-Hee
    • Journal of Environmental Impact Assessment
    • /
    • v.12 no.5
    • /
    • pp.323-340
    • /
    • 2003
  • There have been persistent civil appeals in Ansan area against the odor and aerosols emitted from nearby Banwol/Sihwa industrial complex. A fundamental solution for the good air quality has not been addressed yet in spite of the continuous counterplan to reduce odor emission. A systematic and scientific study is needed to examine the reason for the odor episode and to predict the impact coverage of odor pollution. An approach by computational simulation is considered to be adequate to investigate the transportation and the dispersion processes of air pollutants blown by sea breeze toward the coastal city, Ansan. This study has employed various dispersion models to simulate the transportation and the dispersion processes of odor pollutants by a local circulation between land/sea breeze using the data set of emission rates of odorous species from the Banwol/Sihwa industrial complex.

A study for the design of EIP and by-product exchange network (한국형 생태산업단지 구축 및 자원화 순환망 구축에 관한 연구)

  • Lim, Chang-ho;Rhee, Dong-Seok
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.95-100
    • /
    • 2009
  • Recently, SID (Sustainable Industrial Development) or green growth is the major concern of industries. EIP (Eco Industrial Park) is one of the important part of SID which aims to improve eco-efficiency of resources such as material, energy and water. In this study, current status of Banwol & Sihwa industrial complex relating EIP was investigated and the plan to design of Banwol & Sihwa EIP was suggested.

  • PDF

Applicability Investigation for the Odor Source Tracking Approach using the Wind Field and the Fingerprinting (바람장 및 Fingerprint를 이용한 악취추적기법 활용가능성 평가)

  • Na, Kyung-Ho;Bak, Yong-Chul;Jang, Young-Gi
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.1
    • /
    • pp.1-13
    • /
    • 2007
  • This study was carried out to evaluate the applicability of the odor source tracking using wind field and fingerprint as a solution tool. First of all, CALMET and HYSPLIT modeling system, and database of odor discharge companies were utilized to track odor from industrial complexes. Secondly, industrial odor fingerprint was made by listing on the 19 domestic industries, and compared with foreign data to assess the representative, and thus the similarity was 86.7%. On the modeling experiment, Sihwa industrial complex did not show any difference because the matching rates of day and night were 49.5% and 50.0%, respectively. However, the Banwol and Sihwa industrial complexes did show some differences due to odor facility density. Separately, in this study, odor samples were obtained from 10 odor discharging companies, located in the Sihwa and Banwol industrial complexes, They were compared with the results of odor tracking modeling. The matched companies were 4 of 10 by three cases of tracking, while the fingerprint and industry of odor monitoring networks and companies matched each other. Therefore, this study confirmed the approach applicability of source tracking system using the fingerprint.

Distribution Characteristics of Volatile Organic Compounds (VOCs) in an Industrial Complex and in Affected Areas in Siheung and Ansan (시흥·안산 산단 및 영향지역의 휘발성유기화합물질(VOCs) 분포 특성)

  • Kim, Dong-Gi;Woo, Jung-Sik;Han, Hyun-Su;Kim, Yong-Jun;Kim, Woong-Soo;Hong, Soon-Mo;Kim, Jong-Soo;Yoon, Mi-Hye
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.3
    • /
    • pp.256-266
    • /
    • 2020
  • Objectives: The concentrations and distribution characteristics of volatile organic compounds (VOCs) in an industrial complex and surrouding affected residential areas were investigated in an effort to support the efficient management of VOCs. Methods: The atmospheric concentrations of VOCs were analyzed at sites around the Sihwa-Banwol complex located in the cities of Siheung and Ansan and in the surrounding affected residential areas. The appearance of VOCs and the characteristics of their temporal and spatial distribution were evaluated. Results: The total VOC concentrations in the industrial complex were detected at 1.9-2.3 times higher than in the affected areas, but the daily VOCs distributions showed similar patterns in both sites. In particular, it was confirmed that the composition ratio of the VOCs and concentration fluctuations over time in the affected areas are similar to those in the adjacent industrial complex. VOC levels in the affected areas were higher than in residential areas in cities without an industrial complex. Conclusions: VOCs in residential areas near an industrial complex were highly distributed due to the influence of continuous pollutant emissions from the industrial complex. Therefore, the management of VOCs in the atmosphere of the affected area is important for identifying and managing the sources of VOCs detected in high concentrations in the industrial complex.

A Study on the Concentration Distribution of Airborne Heavy Metals in Major Industrial Complexes in Korea (국내 주요 산업단지 대기 중 중금속농도 분포에 관한 연구)

  • Kang, Byung-Wook;Kim, Min-Ji;Baek, Kyung-Min;Seo, Young-Kyo;Lee, Hak Sung;Kim, Jong-Ho;Han, Jin-Seok;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.2
    • /
    • pp.269-280
    • /
    • 2018
  • This paper reports the results of field evaluation to determine the levels of heavy metals in major industrial complexes in Korea over a seven year period (2007~2013). The measurement of heavy metal was conducted using quartz fiber filter sampling and ICP-AES analysis. In order to validate the analytical performance of these methods, studies were also carried out to investigate data quality control(QC) parameters, such as the method detection limit (MDL), repeatability, and recovery efficiencies. The average concentrations of total suspended particulates (TSP) for the nine industrial complexes in Korea were $104{\sim}169{\mu}g/m^3$, which was higher than other industrial complexes and urban areas. The Sihwa and Banwol industrial complexes were shown to be the biggest contributing sources to high TSP emission ($159{\mu}g/m^3$ and $169{\mu}g/m^3$, respectively). The concentrations of heavy metals in TSP were higher in the order of Fe>Cu>Zn, Pb, Mn>Cr, Ni, As and Cd. It was observed that Fe was the highest in the Gwangyang and Pohang steel industrial complexes. The concentrations of Zn and Pb were high in Onsan, Sihwa and Banwol industrial complexes, and this was attributed to the emission from the nonferrous industry. Additionally, Cr and Ni concentrations were high in the Sihwa and Banwol industrial complexes due to plating industry. On the other hand, Ulsan and Onsan industrial complexes showed high Cr and Ni concentrations as a response to the emission of metal industry related to automobile. The correlation analysis revealed the high correlation between Cr and Ni in plating industry from Sihwa and Banwol industrial complexes. Adding to this, components related to coal combustion and road dust showed high correlation in Pohang and Gwangyang industrial complexes. Then Onsan and Ulsan industrial complexes showed high correlation among components related to the nonferrous metals.

The Relationship Between Odor Unit and Odorous Compounds in Control Areas Using Multiple Regression Analysis (다중회귀분석을 이용한 악취 관리지역에서의 복합취기강도와 개별악취물질들의 관계에 대한 연구)

  • Kim, Jong-Bo;Jeong, Sang-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.3
    • /
    • pp.191-200
    • /
    • 2009
  • We investigated a trait of odor and the relationship between odor unit and odorous compounds using multiple regression analysis based on data compiled from Sihwa (SIC), Banwol (BIC), Banwol plating (BPIC) and Poseung industrial complex (PIC). These areas are odor control areas in Gyeonggi province. It was revealed that $NH_3$ and styrene concentrations in SIC and BPIC were relatively higher and $H_2S$ concentration especially in mc was more than five times higher than other areas. As a result of regression analysis using SAS, intensity of odor unit was highly related to concentrations of $H_2S$, TMA, styrene and n-valeraldehyde in SIC, $H_2S$, acetaldehyde, and butyraldehyde in BPIC and $NH_3$ in BIC.

Concentration level of Volitile Organic Compounds about the Air of Source Boundary Site in Seongseo Industrial Complex (대구성서산업단지 발생원부지경계 대기 중 휘발성유기화합물질의 농도수준)

  • An Sang-Young;Choi Sung-Woo
    • Journal of Environmental Science International
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2005
  • The concentrations of volatile organic compounds(VOCs) in the ambient air were measured at various point(Source, source boundary) in Seongseo industrial complex during May to November 2003. Air samples were collected in Silcocan canister $(1{\ell},\;6{\ell})$ and analyzed using a cryogenic preconcentration system and GC/MSD. We identified 37 species by the US EPA(TO-14 method). The result showed a variety distribution of the con­centration, Higher concentrations of BTX, Styrene, 1,3,5-Trimethylbenzene, 1,2,4-Trimethylbenzene were observed at the sampling sites. They seemed to be emitted from the facility of wastewater treatment, reaction tank of chemistry factory and facility of Tenter. The concentrations of VOCs contents in Seongseo industrial complex were generally higher than those in Yeosu complex and Ulsan complex, although those were similar in Sihwa­Banwol complex.

A study for the recycling of dyeing sludge and by-product exchange network (염색슬러지 탄화물 재활용 및 자원화 순환망 구축 타당성에 관한 연구)

  • Lim, Chang-ho;Kim, Joo-cheong;Rhee, Dong-Seok
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.89-94
    • /
    • 2009
  • The dyeing sludge is the major waste generated in Banwol & Sihwa Industrial Complex. The Purpose of this study is to develop BAT (Best available technique) for the treatment and recycling of dyeing sludge. The dyeing sludge was carbonized and the product was tested physical properties and chemical chracterizations and also analyzed chemical compositions. From the test results we expect that the products can be used as adsorbent for the removal of order in the poultry farm and cattle shed. The feasibility of other methods such as manufature of RDF and cement etc. were also studied.

  • PDF