• 제목/요약/키워드: Balloon Catheter

검색결과 107건 처리시간 0.033초

경동맥 절제술 및 치환술 1례 (A Case of Carotid Artery Resection and Replacement)

  • 김대식;오천환
    • 대한기관식도과학회지
    • /
    • 제5권2호
    • /
    • pp.202-206
    • /
    • 1999
  • A carotid artery resection and replacement including neck dissection are used as a method of treatment for head and neck cancer with infiltration into the carotid artery. The recent development of imaging technique makes it easy to estimate the detailed anatomical relationship between the tumor infiltration into the carotid artery, it's resection and replacement are indicated at radical neck dissection. To detect any possibility of cerebral ischemia at the time of ligation of carotid artery, a temporary occlusion test of internal carotid artery with a ballon catheter (balloon occlusion test) is performed. Recently, we performed a carotid artery resection and replacement using an artificial vessel Gore-Tex) in a case of neck cancer with infiltration into the carotid artery.

  • PDF

Clinical Experiences of Transforaminal Balloon Decompression for Patients with Spinal Stenosis

  • Kim, Sung-Hoon;Koh, Won-Uk;Park, Soo-Jin;Choi, Woo-Jong;Suh, Jeong-Hun;Leem, Jeong-Gil;Park, Pyung-Hwan;Shin, Jin-Woo
    • The Korean Journal of Pain
    • /
    • 제25권1호
    • /
    • pp.55-59
    • /
    • 2012
  • Lumbar spinal stenosis is a commonly treated with epidural injections of local anesthetics and corticosteroids, however, these therapies may relieve leg pain for weeks to months but do not influence functional status. Furthermore, the majority of patients report no substantial symptom change over the repeated treatment. Utilizing balloon catheters, we successfully treated with three patients who complained persistent symptoms despite repeated conventional steroid injections. Our results suggest that transforaminal decompression using a balloon catheter may have potential in the nonsurgical treatment of spinal stenosis by modifying the underlying pathophysiology.

인터벤션에서 Calibration Mode에 대한 오차율 비교 (Comparison on the Error Rates of Calibration Modes in Intervention)

  • 공창기;류영환
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.619-626
    • /
    • 2020
  • 이 연구의 목적은 경피적 혈관내 풍선 확장술이나 스텐트 삽입술에서 Balloon이나 Stent의 직경 및 길이를 예측 할 때 사용되는 정량적인 평가 도구인 Calibration Mode중 Catheter Calibration Mode, Auto Calibration Mode 그리고 Segment Calibration Mode에서의 오차율에 대해 알아보고자 하였다. Calibration의 정량적인 평가를 위해 정교하게 제작된 직경 × 길이(2 mm × 80 mm) Copper Wire와 5, 10, 15, 30, 40 mm의 Metal Ball을 이용하여 실험하였고, 아크릴 팬텀은 25 mm, 50 mm, 75mm, 100 mm, 125 mm, 150mm, 175 mm, 200 mm로 하여 각각의 높이에서 혈관조영 촬영장치로 Subtraction 영상을 획득하여 장비 회사에서 제공하는 소프트웨어인 Stenosis Analysis Tools을 이용하여 측정하였다. Catheter Calibration Mode에서의 오차율을 평가하기 위한 방법으로 Copper Wire를 각각의 아크릴 팬텀위에 올려놓고 촬영하였으며, Copper Wire 직경 2 mm를 Catheter의 직경으로 Setting하였고, 길이 8 mm Copper Wire의 길이를 Multi-segments로 측정하여 분석한 결과 1.13 ~ 5.63%의 오차율이 나타났다. Auto Calibration Mode에서의 오차율을 평가하기 위한 방법으로 각각의 아크릴 팬텀을 높이에서 아크릴 높이에 대한 수치를 입력하고, 8 mm Copper Wire의 길이를 Multi-segments 측정하여 분석한 결과 0 ~ 0.26%의 오차율이 나타났다. Segment Calibration Mode에서의 오차율을 평가하기 위한 방법으로 테이블 바닥에 있는 각각의 Metal Ball을 각각 Calibration하고, 각각의 아크릴 팬텀 위에 올려 있는 8 mm Copper Wire의 길이를 측정하여 아크릴 팬텀 높이 변화에 대한 8 mm Copper Wire 길이를 Mutli-segments 측정하여 분석한 결과 1.05 ~ 19.04%의 오차율이 나타났다. 그리고 Auto Calibration Mode에서 OID 변화에 대한 실험은 아크릴 팬텀의 높이는 100mm로 고정하고 OID만 450 mm ~ 600 mm로 변화를 하였을때 오차율은 0.13 ~ 0.38%로 나타났다. 결론적으로 소프트웨어에서 제공하는 정량적인 혈관의 치수평가를 하기 위한 이들 Calibration Mode 중 Auto Calibration Mode에서 높이 값을 입력하는 것이 오차율이 가장 적은 Calibration 방법임을 확인하였으며, Metal ball이나 기타 다른 물체를 이용하여 Calibration을 하기 위해서는 시술부위와 동등한 높이에 놓고 Calibration을 하는 방법이 오차율을 가장 줄일 수 있는 방법으로 사료된다.

Reduction of the Isolated Anterior Wall of the Maxillary Sinus Fracture with Double Urinary Balloon Catheters and Fibrin Glue

  • Kim, Jaehee;Yang, Ho Jik;Kim, Jong Hwan;Kim, Su Jin
    • 대한두개안면성형외과학회지
    • /
    • 제18권4호
    • /
    • pp.238-242
    • /
    • 2017
  • Background: Conservative treatment is performed for isolated anterior wall of the maxillary sinus fractures, in many cases when the fracture is clinically not severe and asymptomatic. Despite the absence of symptoms, complications such as sinusitis, rhinitis, and chronic purulent secretion may develop; therefore, successful reduction is required. We attempted to reduce the risk of complications using an alternative technique: reduction of the fracture with two urinary balloon catheters inserted through the maxillary ostium and fixation using fibrin glue, which minimizes the damage to the bony fragments and sinus mucosa. Methods: In this study, 38 patients who were diagnosed with an isolated anterior wall of the maxillary sinus fracture at our hospital between January 2014 and January 2017 were enrolled. The fracture site was exposed via the Caldwell-Luc approach followed by reduction through the insertion of two urinary balloon catheters using a nasal endoscope and fixation with fibrin glue. The sex, cause of fracture, physical examination, and presence of complications were examined and patient's medical records and facial bone computed tomography scans were analyzed. Results: Radiological evaluation showed that there was no evidence of collapsed reduction fragments. Although some patients had remaining symptoms of hypoesthesia (15%; 3 patients), there were no complications such as infection, rhinitis, sinusitis, and chronic purulent secretion at the surgical site. Conclusion: In this study, we present an alternative surgical technique using two urinary balloon catheters and fibrin glue for the successful reconstruction of an isolated anterior wall of the maxillary sinus fracture. This technique enables precise restoration with a reduced risk of complications.

비내 풍선 카테터 유도하 경안와 접근법을 이용한 안와 하벽 골절 정복 1예 (A Case of Transorbital Orbital Floor Fracture Repair Assisted Endonasal Balloon Catheter)

  • 김민준;김정석;박태정;정태영
    • 임상이비인후과
    • /
    • 제29권2호
    • /
    • pp.276-280
    • /
    • 2018
  • It is important to choose which approaches should be used to correct the fracture if the operation is indication for surgery in patients with orbital floor fracture. Transorbital, transantral, and endonasal approaches are methods for correcting the orbital floor fracture. The approach needs to be considered the location of the fracture, the degree, the severity of the fracture, the least remaining patient's disability, and preference of the surgeon. We report a case of orbital floor fracture using transorbital approach and endonasal catheter ballooning to resolve the limitations of transorbital approach alone.

Takayasu 씨 동맥염 - 치험 1례 (Takayasu`s Arteritis: A case Report)

  • 송진천
    • Journal of Chest Surgery
    • /
    • 제23권2호
    • /
    • pp.402-406
    • /
    • 1990
  • Recently we have experienced a case of Takayasu’s arteritis involving both common carotid artery, left subclavian artery, left renal artery, and the right pulmonary artery. The patients was 27 year-old female and she was admitted because of neck pain, dizziness and palpitation. Renal artery angioplasty with Griintzig balloon catheter was performed with successful result. And then bypass graft surgery using bifurcated Gore- Text graft was performed with satisfactory result.

  • PDF

개에서 항문낭 절제를 위한 폴리카테터의 이용 (Use of a Foley Catheter for Anal Sacculectomy in Dogs)

  • 한태성;김중현;조기래;이혜윤;김근형;최석화
    • 한국임상수의학회지
    • /
    • 제24권1호
    • /
    • pp.35-37
    • /
    • 2007
  • 개의 오른쪽 또는 왼쪽 항문낭에 화농성 삼출물이 있거나 항문낭이 개방된 8마리의 개를 대상으로 항문낭 적출술을 하였다. 환자의 체중은 3-8 kg이며. 항문낭을 쉽게 절제하기 위하여 폴리카테터(1.5 ml, 6호)를 이용하여 폐쇄법으로 항문 적출술을 하였다. 항문낭 적출술을 하는 동안 모든 환자에서 폴리카테터를 팽창하여 항문낭을 쉽게 식별할 수 있었다. 항문낭 적출술을 실시 한 환자들을 대상으로 1-3개월 동안 임상증상을 추적하였다. 항문낭 적출술이 만성 항문낭염 또는 항문 질환에 좋은 치료법이었다. 폴리카테터의 이용은 항문낭의 적출 시 항문낭을 쉽게 구별할 수 있었고 경제적이었다.

풍선도자관의 Ho-166-DTPA 흡수선량 (Absorbed Dose for the Endovascular Ho-166-DTPA Brachytherapy Using a Balloon Angio Catheter)

  • 조철우;박찬희;윤석남;강해준;김미화;장지선;박경배
    • 한국의학물리학회지:의학물리
    • /
    • 제13권2호
    • /
    • pp.98-103
    • /
    • 2002
  • 관상동맥 성형술 시행시 재협착률을 줄이기 위하여 풍선도자에 Ho-166을 주입하였을 때 혈관 주위에 전달되는 방사선의 흡수선량을 여러 가지 풍선 직경에 따라 평가하였다. 액체 상태의 Ho-166은 한국원자력연구소에서 중성자핵반응인(n, ${\gamma}$)반응으로 얻었다. 혈관 내벽의 흡수선량을 구하기 위하여 GafChromic film과 개조한 마이크로 메터를 이용하여 거리에 따른 홉수선량을 구하였다. 풍선내의 방사능 농도와 조사시간을 고려하여 흡수선량율의 단위를 Gy/min/GBq/ml 로 구하였다. 이는 단위체적당의 방사능 즉 방사능농도(GBq/ml)에 따른 분당 흡수선량 즉 흡수선량률(Gy/min)이다. 직경이 2.5, 3.0, 3.5, 4.0 mm인 풍선도자의 풍선의 표면에서의 흡수선량율은 각각 0.86, 1.01, 1.11, 1.24 Gy/min/GBq/ml 로 측정 되었다. 풍선표면에서부터 거리에 따라 급격히 감소하는 흡수선량을 정확하게 측정 할 수 있는 방법을 제시하였다. 또한 진공펌프를 이용하여 풍선내의 공기방울을 제거하여 균일한 흡수선량이 되도록 하였다.

  • PDF

심폐바이패스를 사용하지 않는 관상동맥우회술 중 발생한 혈역학적 불안정에 대한 대동맥내 풍선펌프 치료 (Intra-aortic Balloon Pump Therapy for Hemodynamic Instability during Off-pump Coronary Artery Bypass Surgery)

  • 정동섭;김기봉;최은석
    • Journal of Chest Surgery
    • /
    • 제42권6호
    • /
    • pp.704-709
    • /
    • 2009
  • 배경: 본 연구는 심폐바이패스를 사용하지 않는 관상동맥우회술 중 발생한 혈역학적 불안정에 대한 대동맥내 풍선펌프 치료의 유용성을 평가하고자 하였다. 대상 및 방법: 2000년 1월부터 2006년 12월까지 심폐바이패스를 사용하지 않는 관상동맥우회술을 받은 796명의 환자를 대상으로 하였다. 수술중 대동맥내 풍선펌프 삽입이 필요했던 환자들을 I군(n=39), 삽입하지 않았던 환자들을 II군(n=757)으로 분류하였다. 결과: 두 군간에 수술 사망률(2.6%, 1/39 vs. 0.8%, 6/757; p=0.195)과 심방 세동(p=0.691), 뇌졸중(p=0.908), 종격동염(p=0.781) 이환율의 차이는 없었다. 인공호흡기 치료 시간, 중환자실 및 병원 재원 기간은 I군에서 II군보다 길었다 (p<0.05). 다변량 분석에서 수술 중 대동맥내 풍선 펌프 삽입이 수술 사망률을 유의하게 증가시키진 않았다(p=0.549). I군에서 대동맥내 풍선 펌프 치료와 관련하여 수술적 치료가 필요했던 합병증이 3예 있었으나(7.9%), 대동맥내 풍선 펌프 삽입 술기를 변형한 2003년 이후에는 발생하지 않았다. 결론: 심폐바이패스를 사용하지 않는 관상동맥우회술 중 혈역학적 불안정이 발생한 경우 대동맥내 풍선펌프를 이용하여 비교적 적은 합병증으로 관상동맥우회술을 시행할 수 있었다.

풍선판막성형술과 동맥관 스텐트를 이용하여 치료한 심실중격결손을 동반하지 않은 폐동맥 폐쇄 1례 (Intervention with Balloon Valvuloplasty followed by Patent Ductus Arteriosus Stent in a Patient with Pulmonary Atresia with Intact Ventricular Septum)

  • 임한혁;김영득;장미영;이재환;길홍량
    • Clinical and Experimental Pediatrics
    • /
    • 제48권11호
    • /
    • pp.1256-1256
    • /
    • 2005
  • 심실중격결손을 동반하지 않은 폐동맥 폐쇄(pulmonary atresia with intact ventricular septum)는 전체 선천적 심장병의 1%를 차지하는 드문 질환으로 형태학적 특성에 따라 다양한 치료적 접근이 필요하다. 이에 저자들은 정상 크기발달의 우심실을 가진 심실중격결손을 동반하지 않은 폐동맥 폐쇄가 있는 신생아에서 풍선판막성형술 후 지속적인 저산소증을 보여 동맥관 스텐트를 이용하여 거의 정상적인 심장구조와 기능으로 호전된 1례를 경험하였기에 보고하는 바이다.