• Title/Summary/Keyword: Balloon Catheter

Search Result 107, Processing Time 0.026 seconds

A Case of Postintubation Tracheal Stenosis Treated by Endoscopic Nd-YAG Laser and Balloon Catheter (Nd-YAG 레이저와 풍선도관을 이용하여 치료한 기관내 삽관 후 발생한 기관협착 1예)

  • Park, Jeong-Woong;Park, Sang-Jun;Suh, Gee-Young;Kim, Ho-Cheol;Chung, Man-Pyo;Kim, Ho-Joong;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.3
    • /
    • pp.624-629
    • /
    • 1998
  • The complications of endotracheal intubation are inevitable, of which postintubation tracheal stenosis may be required for surgical resection with primary reconstruction. Before surgery, several less invasive therapeutic modalites including bougie dilatation, stenting, and Nd-YAG laser incision are still available in use. Especially, good results were noted in selected patients with lengthy scars of less than 1cm and without tracheomalacia using endoscopic laser incision and dilatation. We report a case of a 54 yr-old woman with postintubation tracheal stenosis who was successfully treated by endoscopic Nd-YAG laser incision and esophageal balloon catheter.

  • PDF

Surgical Treatment for Rupture of the Right Common Iliac Artery Caused by Transcatheter Balloon Aortic Valvuloplasty in a Baby with Congenital Aortic Stenosis - A case report - (선천성 대동맥 판막 협착증에서 풍선 판막 성형술 중 발생한 총장골 동맥 파열의 외과적 치료 -1예 보고 -)

  • Han, Jong-Hee;Kim, Yong-Ho;Yu, Jeong-Hwan;Kim, Si-Wook;Kil, Hong-Ryang;Yu, Jae-Hyeon
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.116-119
    • /
    • 2008
  • Transcatheter interventions are widely used for diagnosis and treatment of congenital heart disease. Complications associated with transcatheter interventions are uncommon. However, when they occur they are most often self-limited. Rarely, however, serious catheter related complications occur that may require emergent surgical intervention. In this case, the right common iliac artery was disrupted during transcatheter balloon valvuloplasty during the treatment of congenital aortic stenosis in a 2-week-old baby. After immediate surgical intervention with bleeding control using two balloon catheters the baby did well. Here we report this case and review the medical literature.

Neck Clipping of Giant Aneurysm in ICA Using Intra-Operative Temporary Balloon Occlusion and Suction Decompression Technique - A Case Report - (술중 풍선 확장을 이용한 일시적 근위부 결찰과 흡입, 감압술을 실시한 내경동맥의 거대동맥류 결찰 - 증례보고 -)

  • Weon, Keun Soo;Shin, Yong Sam;Park, Han Jun;Lee, Seung Un;Yun, Su Han;Cho, Ki Hong;Cho, Kyung Gi
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.165-169
    • /
    • 2001
  • Apatient, 51 years old woman, had suffered form headache and decrease of visual acuity. She had $3{\times}3cm$ sized giant aneurysm originated in cavernous and clinoid portion of left ICA(C4,C5) in the cerebral angiography. Before craniotomy, left CCA was exposed and 6F double lumen catheter was inserted in left ICA through the sheath. Pre-operative angiography was done. balloon catheter was positioned at the petrous portion of ICA. Eyebrow approach was done and giant aneurysm was exposed. The proximal blood flow was controlled with balloon dilatation and suction and decompression was tried, then multiple clips were applied. The loss of distal blood flow under intra-operative angiography was notified after clipping. The position of clips were repositioned to preserve blood flow & the rich flow was confirmed at distal part of clipping. In the post-operative cerebral angiography, the same finding was shown.

  • PDF

Transcervical Embryo Recovery in Korean Black Goats: A Preliminary Experiment

  • Lee, Doo-Soo;Kim, Dong-Woo;Shin, Sang Tae
    • Journal of Embryo Transfer
    • /
    • v.30 no.3
    • /
    • pp.171-174
    • /
    • 2015
  • Four pluriparous Korean black goat does were superovulated with FSH and mated with fertile bucks. Anesthetized animals were placed in lateral recumbency, then size 8 Foley catheter was inserted into the uterus through the cervix under the vaginal speculum and the balloon was inflated to fix the catheter in the uterine body. The opposite end of the catheter was connected to a 3-way and a flushing medium was infused into the uterus. Modified Dubecco's PBS with 1% FBS was used as the flushing medium. Four goats were allocated in two groups depending on the type of medium infusion into uterus. Injection group; the flushing medium was injected into uterus and the infused medium was collected by to-and-fro method using a syringe. Gravity-flow group; the flushing medium was allowed to enter the uterus by gravity flow by lifting the medium bottle and drained out of the uterus into a collecting tube. All four goats had catheter inserted through the cervix and uteri flushed successfully. The volume (recovery rate) of recovered medium varied considerably from 87 ml/200 ml (43.5%) to 148 ml/160 ml (92.5%). Nine embryos/ova in total were recovered from Gravity-flow group goats. Although the embryo recovery rate was low, the possibility of a transcervical embryo recovery in Korean black goat had been proven in this preliminary experiment.

A double-knotted pulmonary artery catheter with large loop in the right internal jugular vein -A case report-

  • Yoon, Kyoung Sub;Kim, Jung A;Hong, Jeong In;Kim, Jeong Ho;Park, Sang Yoong;Choi, So Ron
    • Kosin Medical Journal
    • /
    • v.33 no.2
    • /
    • pp.240-244
    • /
    • 2018
  • Knotting of a pulmonary artery catheter (PAC) is a rare, but well-known complication of pulmonary artery (PA) catheterization. We report a case of a double-knotted PAC with a large loop in a patient with hepatocellular carcinoma (HCC) undergoing liver transplantation, which has been rarely reported in the literature. A PAC was advanced under pressure wave form guidance. PAC insertion was repeatedly attempted and the PAC was inserted 80 cm deep even though PAC should be normally inserted 45 to 55 cm deep. However, since no wave change was observed, we began deflating and pulling the balloon. At the 30-cm mark, the PAC could no longer be pulled. Fluoroscopy confirmed knotting of the PAC after surgery (The loop-formed PAC was shown in right internal jugular vein); thus, it was removed. For safe PA catheterization, deep insertion or repeated attempts should be avoided when the catheter cannot be easily inserted into the pulmonary artery. If possible, the insertion of PACs can be performed more safely by monitoring the movement of the catheter under fluoroscopy or transesophageal echocardiography.

Balloon Valvuloplasty for Congenital Pulmonary Valve Stenosis (풍선 카테터에 의한 폐동맥 판막 성형술)

  • Park, Kook-Yang;Kim, Chang-Ho
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1256-1262
    • /
    • 1990
  • Percutaneous pulmonary valvuloplasty was performed in 19 patients of congenital pulmonary valve stenosis. Pulmonary annulus diameter was estimated by cross sectional echocardiography and right ventricular cineangiography. The size of balloon dilatation catheter was chosen by the same size of the estimated pulmonary annulus in the first 3 patients and 20 \ulcorner30% greater than the annulus in the last 17 patients. After valvuloplasty a satisfactory results was obtained in most patients. Before dilatation, the right ventricular systolic pressure was 91.7 mmHg[range 58-150 mmHg] and it fell to 49.2mmHg[25-85 mmHg] after dilatation. The transvalvular gradient was 67.7 mmHg[33 \ulcorner120 mmHg] before dilatation and it fell to 23.7mmHg [5 \ulcorner62] after dilatation. Repeat cardiac catheterization has been scheduled in all patients 3 months after the initial valvuloplasty but follow up recatheterization was performed in only two patients; in one of them residual gradient of 50 mmHg was reduced to 30 mmHg by repeat valvuloplasty. The other patient showed no evidence of restenosis with transvalvular gradient of 20 mmHg The balloon used for valvuloplasty was single balloon for the first 10 cases and for the later 10 cases it was replaced by Trefoil balloon which was easier for inflation and deflation. There were no significant complications during and after the procedure. From our results, we conclude that balloon valvuloplasty for congenital pulmonary valve stenosis is the treatment of choice in most patients.

  • PDF

The Developing Trend of Cardiovacular Drug Coated Balloon Catheter (심장혈관용 약물코팅풍선카테터의 개발 동향)

  • Park, Junghun;Jo, Won-Il;Byeon, Dae-Heung;Kang, So Young;Nam, Choong-hyun;Seo, Kyoung-Woo;Park, Jun-Kyu
    • Applied Chemistry for Engineering
    • /
    • v.33 no.5
    • /
    • pp.545-550
    • /
    • 2022
  • As a result of the rapid entry into an aging society and westernized eating habits, the number of heart disease patients caused by angina pectoris, myocardial infarction, and high blood pressure has increased by more than 100,000 over five years. Heart disease has consistently ranked second in the cause of death in Korea over the past eight years, and medical expenses consumed annually reach 6 trillion won. While various treatments are being proposed for more patients, drug-coated balloon catheters have been developed and gradually commercialized to solve the disadvantages of stent implantation such as restenosis and increased risk of bleeding due to long-term double antiplatelet medication. In Korea, it began to use a drug-coated balloon catheter with the first release of it called "SeQuent Please (Bibrown Korea)" in 2010. Its demand increased gradually as insurance benefits were applied in 2012. Drug-coated balloon angioplasty is increasing in use not only in Korea but also around the world, especially in the Asia-Pacific region, including Japan. Until now, the demand for domestic products is increasing, and if the efficiency in vivo and clinical trials is proven in the future, it is expected to be an effective procedure compared to high-risk stent implantation.

Endoscopic Balloon Dilatation in Children with Congenital and Acquired Esophageal Anomalies (소아의 선천성 및 후천성 식도 질환에서 내시경적 풍선 확장술)

  • Kwak, Ju Yuong;Park, Jae Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.8 no.2
    • /
    • pp.137-142
    • /
    • 2005
  • Purpose: To evaluate the safety, efficacy and technical problems of the endoscopic balloon dilatation of esophageal anomalies in children. Methods: The medical records of 8 children treated by endoscopic balloon dilatation for esophageal anomalies over a 10-year period at Pusan National University Hospital were reviewed retrospectively. The balloon catheter (Maxforce TTS or CRE, Boston Scientific Co., USA) was positioned across the area of narrowing by direct visualization. The balloon was slowly inflated with normal saline to specified pressures for each balloon and maintained for 60 seconds and then deflated. After 60 seconds pause, the procedure was repeated with a larger sized balloon (increments of 1 mm for each subsequent dilation) till effective dilatation was confirmed by direct visualization without complications. Results: Three male and five female were included and their mean age was 4.2 years. A total of 27 (average of 3.2 per patient) dilatation were performed. Underlying diseases of patients are postoperative stricture of esophageal atresia in 3 cases, esophageal ring in 2 cases, achalasia, corrosive esophagitis and hypertensive LES in one case respectively. The size of initial dilating balloon was chosen on the basis of the diameter of the narrowing determined by endoscopy. The first dilation in patients with severe esophageal stricture was made with a 6 mm sized balloon. Complications observed were esophageal perforation and respiratory holding during the procedure in one case respectively. Successful outcome was seen in 6 patients (75%). Conclusion: Endoscopic balloon dilatation can provide a safe and effective mean of treating esophageal anomalies in children and should be considered the treatment of choice in the initial management of those cases.

  • PDF

Surgical Removal of Knotted Pulmonary Artery Catheter -A case report- (매듭지어진 폐동맥도관의 외과적 적출 -1례 보고-)

  • Kim, Byung-Il;Kim, Hyuk;Sohn, Sang-Tae;Jeong, Tae-Yeol;Chung, Won-Sang;Kim, Young-Hak;Kang, Jeong-Ho;Jee, Heng-Ok
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.315-317
    • /
    • 1999
  • The complications associated with the use of pulmonary artery catheter include dysrhythmias, heart block, pulmonary artery rupture, pulmonary infarction, endocardial damage, balloon rupture, arterial puncture, thromboembolism, air embolism, infection, pneumothorax, and knotting of the catheter. Knotting of the catheter is a rare complication and it should be anticipated if there is an excessive advancement of the pulmonary artery catheter beyond the normally expected distance. We report a successful surgical removal of knotted pulmonary artery catheter by sternotomy and cardiopulmonary bypass.

  • PDF

Effects of modified double balloon catheterization for prostatic fluid collection in dogs (개에서 전립선액의 채취를 위한 이중발룬 카테터의 효과)

  • Eom, Ki-dong;Yoon, Jung-hee
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.4
    • /
    • pp.929-935
    • /
    • 1998
  • 개에서 전립선액의 채취를 위한 이중발룬카테터의 효과를 알아보고자 새로이 고안한 이중발룬카테터를 이용하여 추출한 전립선액의 오염여부를 검증하였다. 총21두의 개를 이용하여 전립선액 오염여부에 대한 검증으로서 전립선액, 생검조직 및 요도 관류액중의 요크레아틴 농도측정과 배양검사를 실시하였다. 요크레아틴 농도를 측정한 결과 전립선액(0.028mg/dl)과 조직내(0.66mg/dl)에서 세척관류액(18.71mg/dl) 보다 유의성 있게(p < 0.001) 낮은 농도를 보여 뇨성분의 혼입을 최소화할 수 있는 것으로 평가되었다. 요도부 시료의 배양검사에서 양성결과를 나타낸 12마리중, 이중발룬카테터를 이용하여 전립선액을 채취한 결과 방광으로부터의 오염을 보인 1마리를 제외하고 독립적인 배양결과를 얻을 수 있었으며, 방광 및 요도로부터의 오염방지 효과는 92%를 나타냈다. 이중발룬카테터는 전립선 요도부의 카테터 장착의 용이성 및 요도로부터 오염방지 효과를 갖고 있어 손쉽게 전립선액을 추출할 수 있는 유용한 방법이라고 사료된다.

  • PDF