• 제목/요약/키워드: Balloon Catheter

검색결과 107건 처리시간 0.032초

ERCP 시술중 Balloon Cholangiography의 유용성에 관한 고찰 (A Study on Usefulness of Balloon Cholangiography in Operating ERCP)

  • 손순룡
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권1호
    • /
    • pp.43-49
    • /
    • 1997
  • Purpose of this paper is to extend help for clinical application in balloon cholangiography on patients who have undergone endoscopic sphincterotomy, impacted stones of intrahepatic duct, and missed bile duct because of other diseases in operating endoscopic retrograde cholangiopancreatography. This study was done for the patients who had clinical signs of biliary diseases from January to December In 1996. We studied 45 patients who had endoscopic sphincterotomy, re-examination after interventional treatment of the endoscopic retrograde cholangiopancreatography, and uncertain diagnosis due to common bile duct and intrahepatic duct those are not filled with contrast media. Balloon cholangiography was performed in case of uncertain diagnosis while operating endoscopic retrograde cholangiopancreatography. First of all, we insert balloon catheter Into the working channel of treatment jejunofiberscope and remove treatment Jejunofiberscope after ballooning, and lastly take biliary tract X-ray after Injection and changing position of patient. The results of this study were as follows. (1) In classification of diseases, stones of gall bladder, those of common bile duct, and those of intrahepatic duct were 30 cases, fistula was 1 case. (2) In total cases of 45, only diagnosis were 25 cases, interventional treatment were 20 cases. (3) In case of interventional treatment, endoscopic sphincterotomy and endoscopic nasobiliary drainage, and stone removal were about the same, 7, 7, 6 respectively. Balloon cholangiography will be useful to prevent patients from having repeated and unnecessary studies for the cases above explained. It is considered that this study will be useful for clinical application in terms of reducing medical expenses, pain while examination, and consultation hours.

  • PDF

Removal of a Left Upper Lobar Bronchial Foreign Body Using Fogarty Catheter and Rigid Bronchoscope

  • Woo, Hyunjun;Kim, Seo Young;Kwon, Seong Keun
    • 대한후두음성언어의학회지
    • /
    • 제33권1호
    • /
    • pp.37-41
    • /
    • 2022
  • Airway foreign body aspiration in children can lead to accidental death, due to the foreign body itself or the removal procedure. Depending on its location, removal of the foreign body can be challenging. Here, we present a case of successful removal of a foreign body from the left upper lobar bronchus via ventilating bronchoscopy with a rigid bronchoscope and Fogarty arterial embolectomy catheter. Tracheobronchial foreign bodies in locations that are difficult to reach with forceps, due to an acute angle or the small diameter of the pediatric bronchial tree, can be effectively removed with a Fogarty arterial embolectomy catheter.

GafChromic 필름을 이용한 Ho-166 의 혈관내 방사선조사를 위한 선량분포 측정 (The Measurement of Ho-166 Absorbed Dose for the Endovascular Irradiation with a Balloon Angio Catheter Using a GafChromic Film)

  • 강해진;조철우;박찬희;오영택;전미선;김영미;박경배
    • 한국의학물리학회지:의학물리
    • /
    • 제10권3호
    • /
    • pp.151-157
    • /
    • 1999
  • 심장 혈관 협착증 환자의 경우 수술후 재협착을 방지하기 위하여 혈관내 방사선 조사를 실시하여 혈관내벽의 세포증식을 억제하는 방법이 시도되고 있다. 이를 위해 여러 가지 방사성 동위원소가 사용되고 있지만 한국원자력연구소에서 생산되는 Ho-166 도 그 중의 하나의 원소이다. 따라서 이 Ho-166 을 이용하여 혈관내 방사선조사를 할 경우 선량분포를 측정해 보았다. 혈관 내벽을 방사선 조사하는 방법은 풍선 혈관 카테터를 혈관내에 위치시키고 풍선 안에 액체 상태인 Ho-l66 동위원소를 채우고 일정시간 머물게 함으로써 시행된다. 선량분포를 측정하기 위하여 Solid water phantom 과 방사선 흡수선량에 따라 현상기에 현상을 하지 않아도 바로 필름 흑화도 변화를 볼 수 있는 GafChromic Film 을 사용하였다. 필름 흑화도 측정은 Videodensitometer를 이용하였으며 Co-60 빔에 검교정된 GafChromic 필름의 흑화도로 부터 풍선 혈관 카테터 안에 있는 Ho-166 동위원소에 의한 선량분포플 측정하였다. 먼저 Co-60 빔을 이용한 GafChromic Film 의 calibration curve를 얻었다. 흡수선량 대 필름 흑화도 곡선 (H-D curve)은 직선을 이루지 않았으며 이는 densitometer에 쓰이는 광원으로 부터 짐작되는 결과이다. H-D 곡선을 이용하여 Ho-l66이 채워진 풍선 혈관 카테터로 부터의 거리에 따른 선량분포를 얻었으며 카테터 표면으로 부터 1 mm 떨어진 거리에서의 선량은 풍선 표면에서의 약 20% 정도 였으며 5mm 떨어진 거리에서는 풍선 표면 선량의 약 1% 정도로 급속히 떨어짐을 볼 수 있었다. 혈관내 방사선 조사시 중요한 것은 혈관 내 벽에는 원하는 만큼의 방사선량을 주어야 하지만 주변의 정상조직에는 최소한의 손상을 유지해야 하므로 선량분포가 동위원소로 부터 떨어졌을 때 급속히 감소해야 한다는 것이다 따라서 이와같은 이유 때문에 베타선 방출 핵종 들이 많이 시도되고 있으며 동위원소 Ho-l66 도 혈관내벽 방사선조사를 위한 하나의 좋은 핵종으로 이용할 수 있다.

  • PDF

Absorbed Dose from Large Balloon Filled with Liquid Ho-166

  • Joh, Chul-Woo;Park, Chan H.;Lee, Myoung-Hoon;Yoon, Seok-Nam;Kim, Mi-Hwa;Jang, Ji-Sun;Park, Kyung-Bae
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.328-330
    • /
    • 2002
  • Large balloon angio catheter is used for Percutaneous Transluminal Angioplsty(TPA) of the iliac, femoral and renal arteries as well as after Transjugular Intrahepatic portosystemic shunt(TIPS). The use of angioplasty balloon filled with liquid form of radioisotope reduces the rate of restenosis after PTA. The purpose of this study was to evaluate the absorbed dose to the target vessels from various sized large balloon filled with liquid form of Ho-166-DTPA. Four balloons of balloon dilatation catheters evaluated were 5, 6, 8 and 10 mm in diameter. GafChromic film was used for the estimation of the absorbed dose near the surface of the balloon catheters. Absorbed dose rates are plotted in units of Gy/min/GBq/ml as a function of radial distance in mm from the surface of balloon. The absorbed dose rate was 1.1, 1.6, 2.2 and 2.3 Gy/min/GBq/ml at a balloon surface, 0.3, 0.4, 0.5 and 0.6 Gy/min/GBq/ml at 1 mm depth for various balloon diameter 5, 6, 8 and 10 mm in diameter respectively. The study was conducted to estimate the absorbed doses to the vessels from various sized large balloons filled with liquid form of Ho-166-DTPA for clinical trial of radiation therapy after the PTA. The absorbed dose distribution of Ho-166 appeared to be nearly ideal for vascular irradiation since beta range is very short avoiding unnecessary radiation to surrounding normal tissues.

  • PDF

Analysis of procedural performance after a pilot course on endovascular training for resuscitative endovascular balloon occlusion of the aorta

  • Sung Wook Chang;Dong Hun Kim;Dae Sung Ma;Ye Rim Chang
    • Journal of Trauma and Injury
    • /
    • 제36권1호
    • /
    • pp.3-7
    • /
    • 2023
  • Purpose: As resuscitative endovascular balloon occlusion of the aorta (REBOA) is performed in an extremely emergent situation, achieving competent clinical practice is mandatory. Although there are several educational courses that teach the REBOA procedure, there have been no reports evaluating the impact of training on clinical practice. Therefore, this study is aimed to evaluate the effects of the course on procedural performance during resuscitation and on clinical outcomes. Methods: Patients who were managed at a regional trauma center in Dankook University Hospital from August 2016 to February 2018 were included and were grouped as precourse (August 2016-August 2017, n=9) and postcourse (September 2017- February 2018, n=9). Variables regarding injury, parameters regarding REBOA procedure, morbidity, and mortality were prospectively collected and reviewed for comparison between the groups. Results: Demographics and REBOA variables did not differ between groups. The time required from arterial puncture to balloon inflation was significantly shortened from 9.0 to 5.0 minutes (P=0.003). There were no complications associated with REBOA after the course. Mortality did not show any statistical difference before and after the course. Conclusions: The endovascular training for REBOA pilot course, which uses a modified form of flipped learning, realistic simulation of ultrasound-guided catheter insertion and balloon manipulation, and competence assessment, significantly improved procedural performance during resuscitation of trauma patients.

하지 심부정맥 혈전의 외과적 제거 (Surgical Technique thor the Removal of Deep Vein Thrombi of the Lower Extremities)

  • 이상호;최준영;김성호;김병균;장인석;이정은;옥창대;김종우;나재범
    • Journal of Chest Surgery
    • /
    • 제35권5호
    • /
    • pp.402-406
    • /
    • 2002
  • 하지 정맥의 심부정맥 혈전 제거술의 통례적 수기는 포가티 풍선 카테타를 이용하는 것이었다. 풍선 카테타는 정맥 내에 존재하는 판막의 방해 때문에 수기 상 불편한 것이 단점이다. 겸자(겸자, stone-forceps, Fig. 1)를 사용하면 장골-대퇴정맥 내의 혈전을 판막의 방해를 받지 않고 용이히 제거할 수 있다. 이 기구가 혈전을 꺼내는 동안 판막을 열어 제쳐주기 때문이다. 판막이 열린 상태를 유지 해주므로 이 기구는 장골정맥으로부터의 역혈류(back-flow)를 판단하는 데에도 유용하다. 서혜부 절개 이하의 하지 정맥 내 혈전은 종아리와 허벅지 근육을 효과적으로 압박하는 것만으로 성공적으로 제거할 수 있다. 수술의 순서는 장골 정맥 쪽을 먼저 하는 것을 권한다.

Successful Damage Control Resuscitation with Resuscitative Endovascular Balloon Occlusion of the Aorta in a Pediatric Patient

  • Heo, Yoonjung;Chang, Sung Wook;Kim, Dong Hun
    • Journal of Trauma and Injury
    • /
    • 제33권3호
    • /
    • pp.170-174
    • /
    • 2020
  • Resuscitative endovascular balloon occlusion of the aorta (REBOA) is considered an emerging adjunct therapy for profound hemorrhagic shock, as it can maintain temporary stability until definitive repair of the injury. However, there is limited information about the use of this procedure in children. Herein, we report a case of REBOA in a pediatric patient with blunt trauma, wherein the preoperative deployment of REBOA played a pivotal role in damage control resuscitation. A 7-year-old male patient experienced cardiac arrest after a motor vehicle accident. After 30 minutes of cardiopulmonary resuscitation, spontaneous circulation was achieved. The patient was diagnosed with massive hemoperitoneum. REBOA was then performed under ongoing resuscitative measures. An intra-aortic balloon catheter was deployed above the supraceliac aorta, which helped achieved permissive hypotension while the patient was undergoing surgery. After successful bleeding control with small bowel resection for mesenteric avulsion, thorough radiologic evaluations revealed hypoxic brain injury. The patient died from deterioration of disseminated intravascular coagulation. Although the patient did not survive, a postoperative computed tomography scan revealed neither remaining intraperitoneal injury nor peripheral ischemia correlated with the insertion of a 7-Fr sheath. Hence, REBOA can be a successful bridge therapy, and this result may facilitate the further usage of REBOA to save pediatric patients with non-compressible torso hemorrhage.

관상동맥 재협착 방지를 위한 치료에서 $^{32}$ P 핵종의 선원 형태에 따른 선량분포에 관한 연구 (A Study on the dose distribution produced by $^{32}$ P source form in treatment for inhibiting restenosis of coronary artery)

  • 김경화;김영미;박경배
    • 한국의학물리학회지:의학물리
    • /
    • 제10권1호
    • /
    • pp.1-7
    • /
    • 1999
  • 본 연구에서는 $\beta$선 방출 동위원소들 중에서 $^{32}$P으로부터 방출되는 $\beta$선에 의한 홉수선량 분포를 방사선원의 형태와 기하학적인 조건을 달리하여 컴퓨터를 이용한 모사실험을 통해 예측함으로써 balloon catheter 및 radioactive stent의 이용과 관련된 정보를 얻고자한다. $^{32}$p로부터 방출된 $\beta$선이 인체내에서 에너지를 전달하는 과정에 대한 모사실험은 EGS4 code system 을 이용하여 수행되었다. 인체내의 방사선 흡수선량은 선원의 형태와 위치를 고려하여 축방향과 반경방향으로 등간격으로 나누어 각 격자에서 계산되었다. $^{32}$P 에서 방출되는 $\beta$선 에너지는 Coulomb 포텐셜에 대한 Dirac방정식의 해를 이용하여 계산된 $\beta$선 스펙트럼의 결과를 사용하여 무작위로 선정되었다. 체적 선원과 표면선원에서 시료 표면으로부터 반경방향으로 깊이 0.5 mm내에 있는 표적체에서의 선량률은 각각 12.133 cGy/s per GBq (0.449 cGy/s per mCi, uncertainty: 1.51%)와 24.732 cGy/s per GBq (0.915 cGy/s per mCi, uncertainty: 1.01 %)이다. 선량률은 시료표면으로부터 축방향과 반경방향으로의 거리에 따라 감소한다. 본 연구 결과를 근거로하여 balloon catheter 및 radioactive stent에 $^{32}$P 핵종을 사용할 때 치료선량을 20 Gy로 할 경우 치료에 적합한 초기 방사능량은 각각 29.69 mCi(치료시간을 3분으로 제한할 때) 와 1.2278 $\mu$Ci (영구삽입)로 계산되었다. 또한 원통형 체적선원과 표면선원에 대하여 초기방사능의 크기를 1 mCi/ml의 방사능 체적 밀도와 0.1 mCi/$cm^2$의 방사능 면 밀도로 나타내었을 때 각 표적체에서의 흡수선량률을 계산하였다. 통일한 값의 방사능 체적 밀도와 방사능 면 밀도는 크기가 다른 모델에 대해서 비슷한 크기의 홉수선량을 유도하므로 $^{32}$p 방사선원의 초기 방사능 체적 밀도와 초기 방사능 면 밀도를 알고 있을 때 본 연구의 계산 결과를 이용하면 직경과 길이가 다른 $^{32}$P 핵종의 원통형 모델 주위의 홉수선량 분포를 쉽게 계산할 수 있다.

  • PDF