• Title/Summary/Keyword: Ballast Exchange

Search Result 16, Processing Time 0.021 seconds

Optimized Ballast Water Exchange Management for Bulk Carrier (BULK 선용자동 Ballast Water Management Plan 개발)

  • HONG CHUNG YOU;PARK JE WOONG
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.67-72
    • /
    • 2004
  • Many port states such as New Zealand, the USA, Australia and Canada have strict regulations to prevent ships which arrive in their port from discharging polluted ballast water which contain harmful aquatic organism and pathogens. They are notified that transfer of polluted ballast water can cause serious injury to public health and damage to property and environment. For this reason, they perceived that the ballast exchange in deep sea is the most effective method, together with submitting the ballast management plan which contains the effective exchange method, ballast system and safety consideration. In this study, we pursued both nautical engineering analysis and optimization of algorithm in order to generate the sequence of stability and rapidity. Heuristic Algorithm was chosen on the basis of optimality and applicability to a sequential exchange problem. We have built an optimized algorithm, for automatic exchange of ballast water, by redefining core elements of the $A^\ast$ algorithm, such as node, operator and evaluation function. Final version of the optimized algorithm has been applied to existing bulk carrier and the performance of the algorithm has been verified successfully.

  • PDF

Optimized Ballast Water Exchange Management for Bulk Carriers (벌크 화물선용 자동 밸러스트수 교환계획 시스템 개발)

  • HONG CHUNG-YOU;PARK JE-WOONG
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.4 s.59
    • /
    • pp.65-70
    • /
    • 2004
  • Many port states, such as New Zealand, U.S.A., Australia, and Canada, have strict regulations to prevent arriving ships from discharging polluted ballast water that contains harmful aquatic organisms and pathogens. They are notified that transfer of polluted ballast water can cause serious injury to public health and damage to property and environment. For this reason, ballast exchange in deep sea is perceived as the most effective method of emptying ballast water. The ballast management plan contains the effective exchange method, ballast system, and safety considerations. In this study, we pursued both nautical engineering analysis and optimization of the algorithm, in order to generate the sequence of stability and rapidity. A heuristic algorithm was chosen on the basis of optimality and applicability to a sequential exchange problem. We have built an optimized algorithm for the automatic exchange of ballast water, by redefining core elements of the A$\ast$ algorithm, such as node, operator, and evaluation function. The final version of the optimized algorithm has been applied to existing bulk carrier, and the performance of the algorithm has been successfully verified.

The development of auto Ballast Water Management Plan For Bulk Carrier. (BULK선용 자동 Ballast Water Management Plan 개발)

  • Hong, Chung-You;Kwon, Young-Sub;Kwon, Sung-Jin;Hwang, Jin-Wook;Park, Je-Woong
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.266-271
    • /
    • 2003
  • Many port states such as New Zealand. the USA. Australia and Canada have strict regulations to prevent ships which arrive in their port from discharging polluted ballast water which contain harmful aquatic organism and pathogens. They are notified that transfer of polluted ballast water can cause serious injury to public health and damage to property and environment. For this reason. they perceived that the ballast exchange in deep sea is the most effective method. together with submitting the ballast management plan which contains the effective exchange method. ballast system and safety consideration. In this study, we make an effort to develop optimum ballast water exchange management and in result of that. it provide more convenient and stable process to prepare ballast water management plan for Bulk Carrier.

  • PDF

Optimized Ballast Water Exchange Management for Tanker (탱커선 전용의 최적화된 밸러스트수 교체 관리)

  • Hong, Chung-You;Chang, Hyeong-Joon;Kwon, Sung-Jin;Choi, Young-Dal;Kim, Dong-Eon;Park, Je-Woong
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.225-230
    • /
    • 2003
  • Many port states such as New Zealand, the USA, Australia and Canada have strict regulations to prevent ships which arrive in their port from discharging polluted ballast water which contain harmful aquatic organisms and pathogens. They are notified that transfer of polluted ballast water can cause serious injury to public health and damage to property and environment. For this reason, they perceived that the ballast exchange in deep sea is the most effective method, together with submitting the ballast management plan which contains the effective exchange method, ballast system and safety consideration. In this study, we make an effort to develop optimum ballast water exchange management and in result of that, it provide more convenient and stable process for preparing ballast water management plan.

  • PDF

Numerical Simulation of Ballast Water Exchange

  • Kamada, Koichi;Minami, Kiyokazu;Shiotani, Shigeaki;Shoji, Kuniaki
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.10a
    • /
    • pp.157-165
    • /
    • 2006
  • In February,2004, at International Maritime Organization (IMO), LONDON, a new international convention 'International Convention fur the Control and Management of Ship's Ballast Water and Sediment 2004' was adopted. It is called 'Ballast Water Management Convention (BWM)'. Ballast water means charged seawater or fresh water in ship's special tanks (ballast tank) to keep safety navigation and ship's maneuverability. However, from 1980, it was point out the serious problem for marine ecosystem and human life that ballast water includes harmful marine species (and small organisms) and these species are also discharged along with ballast water. These species were released with discharged ballast water in water areas, where species are different from discharged ballast water. The problem is that released species increase when released species are more powerful than native species and consequently, marine ecological system is destroyed in released water area. Authors have inspected the validity of the ballast water exchange using pumping-through method that is one of the methods of ballast water management. In this paper, the numerical simulation of the motion and density of the fluid at the time of exchange of the fluid in a 2-dimensional tank using the pumping-through method was carried out by using two different type numerical methods. One method is MPS method that is one of the particle methods. Other one is Finite Different Method (FDM). Authors were compared with result of two numerical method calculations and experiment result and reported some knowledge from these results.

  • PDF

A Study of the Technical Treatment within an Environmental Appetency for the Ballast Water

  • Nam, Chung-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1313-1323
    • /
    • 2004
  • In accordance with adoption of new convention for the control of ship's ballast water at the diplomatic conference held in London Feb, 2004, every country has to regulate the ballast water and deposit matters. When this Resolution comes into effect in 2009, all vessels engaged in international voyage must have ballast water control program, ballast water records, equipments which are suitable to the standard of exchange and performance for the ballast water. This study estimates objectively their performances, merits and demerits of the ballast water treatment technique and exchanging techniques for safe operation of ships. It is desirable to design an equipment to control the ballast water using the brush-type vacuum suction nonstop reverse cleaning system to overcome the clogging phenomenon and the direct disc filtering to maximize filtering area for the optimum process considering biological availabilities. It will be expected to protect against marine pollution and to maintain clean sea if it is secured to develop new ballast water treatment techniques. And it will also be expected to cope with the Resolution and each regulation of the developed countries from the ballast water.

MONITORING THE BAY OF BENGAL AS A BALLAST WATER EXCHANGEABLE SEA USING MODIS/AQUA

  • Kozai, Katsutoshi;Ishida, Hiroshi;Okamoto, Ken;Fukuyo, Yasuyo
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.483-486
    • /
    • 2006
  • The study describes the monitoring of the Bay of Bengal as a ballast water exchangeable sea using MODIS/Aqua-derived diffuse attenuation coefficient (K(490)) synchronized with in situ ballast water sampling and analysis along the LNG carrier's route between Japan and Qatar from 2002 to 2005. Based on the relationship between K(490) and corresponding in situ plankton cell densities, the Bay of Bengal is recognized as a ballast water exchangeable sea to meet the regulation of ballast water performance standard of International Maritime Organization (IMO). Furthermore the Bay of Bengal with more than 200m depth and more than 200 nautical mile distance from shore is extracted based on the regulation of ballast water exchange area of IMO. However, an anomalously high K(490) area is found off the coast of Sri Lanka during the northeast monsoon in 2005, which corresponds higher cell densities than the criterion set by the regulation of IMO. The phenomenon of high cell density in the Bay of Bengal seems to be related with the phytoplankton bloom during the northeast monsoon. Seasonal and annual variability of phytoplankton bloom will be investigated to establish an early routing system for avoiding the high cell density area in advance.

  • PDF

A study on the development of ballast water management-related familiarization training pursuant to the STCW convention

  • Lee, Young-Chan;Ha, Weon-Jae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.2
    • /
    • pp.163-170
    • /
    • 2017
  • The International Convention for the Control and Management of Ships' Ballast Water and Sediments (hereafter "BWM Convention") will be enforced beginning on September 8, 2017. Even though the STCW Convention (International Convention on Standards of Training, Certification and Watchkeeping for Seafarers) and other international instruments require all ship personnel be qualified under certain competencies and standards, the International Maritime Organization (hereafter "IMO") has no unified requirements for training ship personnel on ballast water management. When the BWM Convention enters into force, all officers and crew on board ships should be intimately familiar with the guidelines and procedures outlined by the BWM Convention, regarding, among other topics, proper record keeping techniques and measures, the layout of the ballast control system, methods of ballast water exchange, and inspections by the port state control. To ensure that officers and crew members are adequately familiar, this paper proposes new competency requirements for ballast water management training and education to be added to the STCW Code. To support the introduction of these new competency requirements, this paper explores the evolution of the BWM Convention and examines how international regulations will be used to implement it.

Applicability Estimation of Ballast Non-exchange-type Quick-hardening Track Using a Layer Separation Pouring Method (층 분리주입을 이용한 도상자갈 무교환방식 급속경화궤도의 적용성 평가)

  • Lee, Il Wha;Jung, Young Ho;Lee, Min Soo
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.6
    • /
    • pp.543-551
    • /
    • 2015
  • Quick-hardening track (QHT) is a construction method which is used to change from old ballast track to concrete track. Sufficient time for construction is important, as the construction should be done during operational breaks at night. Most of the time is spent on exchanging the ballast layer. If it is possible to apply the ballast non-exchange type of quick-hardening track, it would be more effective to reduce the construction time and costs. In this paper, pouring materials with high permeability are suggested and a construction method involving a layer separation pouring process considering the void condition is introduced in order to develop ballast non-exchange type of QHT. The separate pouring method can secure the required strength because optimized materials are poured into the upper layer and the lower layer for each void ratio condition. To ensure this process, a rheology analysis was conducted on the design of the pouring materials according to aggregate size, the aggregate distribution, the void ratio, the void size, the tortuosity and the permeability. A polymer series was used as the pouring material of the lower layer to secure the void filling capacity and for adhesion to the fine-grained layer. In addition, magnesium-phosphate ceramic (MPC) was used as the pouring material of the upper layer to secure the void-filling capacity and for adhesion of the coarse-grained layer. As a result of a mechanics test of the materials, satisfactory performance corresponding to existing quick-hardening track was noted.

Risk Assessment for Retrofitting an Electrolysis Type Ballast Water Treatment System on an Exiting Vessel (현존선에 전기분해방식 선박평형수 처리장치 설치를 위한 위험도 평가 분석)

  • JEE, Jae-Hoon
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.3
    • /
    • pp.665-676
    • /
    • 2017
  • Over the past several years, sea trade have increased traffic by ships which highlighted a problem of unwanted species invading the surrounding seas through ship's ballast water discharge. Maritime trade volume has continuously increased worldwide and the problem still exists. The respective countries are spending billions of dollars in an effort to clean up the contamination and prevent pollution. As part of an effort to solve marine environmental problem, BWM(Ballast Water Management) convention was adopted at a diplomatic conference on Feb. 13 2004. In order to comply harmoniously this convention by each country. This convention will be effective after 12 months from the date which 30 countries ratified accounting for more than 35% of the world merchant shipping volume. On Sep. 8 2016, Finland ratified this convention and effective condition was satisfied as 52 states and world merchant vessel fleet 35.1441%. Thus, after Sep. 8 2017, all existing vessels shall be equipped with BWTS(Ballast Water Treatment System) in accordance with D-2 Regulation, which physically handles ballast water from ballast water exchange system(D-1 Regulation). In this study, we analyzed in detail the optimal design method using the Risk Analysis and Evaluation technique which is mainly used in the manufacturing factory or the risky work site comparing with the traditional design concept method applying various criteria. The Risk Assessment Method is a series of processes for finding the Risk Factors in the design process, analyzing a probility of the accident and size of the accident and then quantifying the Risk Incidence and finally taking measures. In this study, this method was carried out for Electrolysis treatment type on DWT 180K Bulk Carrier using "HAZOP Study" method among various methods. In the Electrolysis type, 63 hazardous elements were identified.