• Title/Summary/Keyword: Ball-on-3-ball test

Search Result 331, Processing Time 0.022 seconds

The effect of particle size on the edge notched disk (END) using particle flow code in three dimension

  • Haeri, Hadi;Sarfarazi, Vahab;Zhu, Zheming;Marji, Mohammad Fatehi
    • Smart Structures and Systems
    • /
    • v.22 no.6
    • /
    • pp.663-673
    • /
    • 2018
  • In this study, the effect of particle size on the cracks propagation and coalescence or cracking pattern of the edge notched disc specimens are investigated. Firstly, calibration of PFC3D was performed using Brazilian experimental test output. Then micro parameters were used to build edge notched disc specimen. The horizontal wall of the assembly is let to move downward with a standard low speed of 0.016 m/s. The numerical results show that the tensile cracks are dominant failure pattern for the modeled discs. These tensile cracks initiate from the pre-existing notch tip and propagate parallel to the loading direction then interact with the upper boundary of the modeled specimen. As the size of the balls (ball diameter) decrease the number of tensile cracks increase. The tensile fracture toughness of the samples also decreases as the particle size increases. Understanding the crack propagation and crack coalescence phenomena in brittle materials such as concretes and rocks is of paramount importance in the stability analyses for engineering structures such as rock slopes, underground structures and tunneling.

Biotribological Properties of TZP/Al2O3 Ceramics for Biomechanical Applications

  • Lee, Deuk-Yong;Lee, Se-Jong;Jang, Ju-Woong;Kim, Hak-Kwan;Kim, Dae-Joon
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.6
    • /
    • pp.525-529
    • /
    • 2003
  • Biotribological properties, such as wear rate and friction coefficient, of 3Y-TZP and Low Temperature Degradation (LTD) free materials were investigated via a ball(SiC)-on-plate sliding wear test to evaluate the relationship between wear mechanism and phase transformation. Wear test was conducted with a sliding speed of 0.035 m/s at room temperature and at 25$0^{\circ}C$ in air under a normal load of 49 N, respectively. Although friction coefficient of 3Y-TZP was the lowest due to the fine grain size, the highest wear loss and rate were observed due to the debris of monoclinic grains introduced during sliding and their values increased drastically with raising temperature. However, the biotribological properties of LTD-free materials were insensitive to temperature due to the inertness of the phase transformation, suggesting that they may be applicable to the biomechanical parts.

Reliability of High Temperature and Vibration in Sn3.5Ag and Sn0.7Cu Lead-free Solders (Sn3.5Ag와 Sn0.7Cu 무연솔더에 대한 고온 진동 신뢰성 연구)

  • Ko, Yong-Ho;Kim, Taek-Soo;Lee, Young-Kyu;Yoo, Sehoo;Lee, Chang-Woo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.3
    • /
    • pp.31-36
    • /
    • 2012
  • In this study, the complex vibration reliability of Sn-3.5Ag and Sn-0.7Cu having a high melting temperature was investigated. For manufacturing of BGA test samples, Sn-3.5Ag and Sn-0.7Cu balls were joined on BGA chips finished by ENIG and the chips were mounted on PCB finished OSP by using reflow process. For measuring of resistance change during complex vibration test, daisy chain was formed in the test board. From the results of resistance change and shear strength change, the reliability of two solder balls was compared and evaluated. During complex vibration for 120 hours, Sn-0.7Cu solder was more stable than Sn-3.5Ag solder in complex vibration test.

Wear Mechanism of CrN Coating on Aluminum Alloys Deposited by AIP Method

  • Kim, Seock-Sam;Suh, Chang-Min;Murakami, Ri-ichi
    • KSTLE International Journal
    • /
    • v.3 no.1
    • /
    • pp.43-48
    • /
    • 2002
  • Dry sliding wear and friction test of CrN coaling on two types of aluminum alloy substrates,6061 Al and 7075 Al deposited by arc ion plating, was peformed with a ball-on-disk tribometer. The effects of normal Bead and the mechanical properties of substrate on the friction coefficient and wear-resistance of CrN coating were investigated. The worn surfaces were observed by SEM. The results show that surface micro-hardness of CrN- coated 7075 Al is higher than that of CrN-coated 6061 Al. With an increase in normal lead, wear volume increases, while the friction coefficient decreases. The friction coefficient of CrN-coated 6061 Al is higher than that of CrN-coated 7075 Al, while the wear-resistance of CrN-coated 6061 Al is lower than the CrN-coated 7075 Al's, which indicates that the substrate mechanical properties have strong inf1uences on the friction coefficient and wear of CrN coating. The main wear mechanism was fragments of CrN coating, which were caused by apparent plastic deformation of substrate during wear test.

Study and Survey of Operating Efficiency with Cool Storage System (빙축열냉방시스템의 운전효율에 관한 조사연구)

  • 손학식;심창호;김강현;김재철
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.1-9
    • /
    • 2002
  • The purpose of this study is to maintain high efficiency and reasonable use of cool thermal storage systems operated in the domestic building sector. As the result of efficiency test from the five types of operated cool storage systems on the condition that COP ranges are 2.6 to 3.4 during the day time and 2.1 to 3.0 during the night time and it decreased by more than 30% of rated COP given 3.8 to 3.0. The Analysis of cool storage rate shows that only 3 (21.4%) systems out of 15 buildings hold to over 40% capacity for its total capacity. To prevent the decrease in operating efficiency, it should correct the malfunction of 3-way valve and expansion valve and the mistake of control values for schedule program and increase cooling tower capacity. In order to improve piping line, it needs bypass brine line off refrigerator, separation of chilled water line with Ice Slurry system at day and night time and speed control of chilled and warm water pumps. This study does require the more studies on improving difficulty of increasing cooling load with Ice on Coil system, waterproofing with Ice Ball system, COP drop during the night time with Ice Lens, low operating temperature during the day time with Ice Slurry and increasing of Power loss due to hot gas de-icing with Ice Harvest in the future.

Effects of a Rehabilitation Nursing Program on Muscle Strength, Flexibility, Self efficacy and Health Related Quality of Life in Disabilities (장애인을 위한 재활간호프로그램이 근력, 유연성, 자기 효능감과 건강관련 삶의 질에 미치는 효과)

  • Lee Hea-Young
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.3
    • /
    • pp.484-492
    • /
    • 2006
  • Purpose: The purpose of this study was to investigate the effects of a rehabilitation nursing program(RNP) for persons with disabilities. Method: a quasi-experimental pretest and post test study was used to examine the changes of patient's muscle strength, flexibility, self efficacy and health related quality of life at the completion of an 8-week education and physical exercise with a Thera-Band and Exercise Ball course. The subjects consisted of 40 adults who were disabled. Twenty-two experimental and 18 control subjects completed pre and post-test measures. Outcome variables were flexibility, hand grip, elbow flexor and extensor, knee flexor and extensor, self efficacy and quality of life. Independent t-test and ANCOVA were used to examine group differences by using SPSS 12.0 Result: Mean comparisons of the change scores revealed that the experimental group increased significantly in knee extremity flexor(p=0.035), extensor(p=0.039), flexibility(p=0.008), self efficacy(p=0.000), and quality of life(p=0.000). No significant group differences were found in each patient's hand grip, elbow flexor and extensor. Conclusion: RNP can improve lower extremity flexibility, muscle strength, self efficacy and health related quality of life in people with disabilities. The intervention to tailor exercise and education to the unique needs of the disability was suggested for further study.

A Study on the Performance Characteristics and Reuse Effect for Recycled Parts of CV Joint and Steering Gear Box in the Vehicles (자동차 중고재생 등속조인트와 스티어링 기어박스의 성능과 활용효과에 대한 연구)

  • 조휘창;박인송
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.199-205
    • /
    • 2002
  • The scale of repair parts market reached 0.1 billion won. Above all, it is remarkable that the automotive insurance business world is paying f3r 40 ~5o% of the whole repair cost. The repair parts consist of a genuine parts, non-genuine parts, recycling used parts. It is the recent trend that recycled parts are more popular than the genuine parts f3r repairing crashed cars due to the cost. Performance of recycled continuous velocity(CV) joints and power steering(PS) gear box as replacement parts was tested and analysed in this study. To examine the durability of the recycled parts, the replaced CV joints and PS gear box after repair were tested and analysed periodically. The results were showed that basic performance of the recycled parts was normal. However the ball cage of CV joints was more frequently damaged than genuine parts. We concluded that a test standard and amendment of related laws for recycled parts is required to get a safe and durable parts.

A Comprasion of the Activation of Mirror Neurons Induced by Action Observation between Simple and Complex Hand Movement

  • Lee, Mi Young;Kim, Ju Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.3
    • /
    • pp.157-160
    • /
    • 2019
  • Purpose: We compared the activation pattern of the mirror neurons (MN) between two types of hand movement according to action observation using functional MRI. Methods: Twelve right-handed healthy subjects (5 male and 7 female, mean age $21.92{\pm}2.02years$) participated in the experiment. During fMRI scanning, subjects underwent two different stimuli on the screen: 1) video clips showing repeated grasping and releasing of the ball via simple hand movement (SHM), and (2) video clips showing an actor performing a Purdue Pegboard test via complex hand movement (CHM). paired t-test in statistical parametric mapping (SPM) was used to compare the activation differences between the two types of hand movement. Results: CHM as compared with the SHM produced a higher blood oxygen level dependent (BOLD) signal response in the right superior frontal gyrus, left inferior and superior parietal lobules, and lingual gyrus. However, no greater BOLD signal response was found by SHM compared with CHM (FWE corrected, p<0.05). Conclusion: Our findings provided that the activation patterns for observation of SHM and CHM are different. CHM also elicited boarder or stronger activations in the brain, including inferior parietal lobule called the MN region.

The effect of texture of an extruded OFHC Cu rod on its sliding wear characteristics (압출된 OFHC Cu 봉재의 집합조직과 마멸거동)

  • Yi, S.K.;Kim, Y.S.;Cho, J.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.354-357
    • /
    • 2009
  • The effect of texture of an extruded OFHC Cu rod on its sliding wear has been explored. Disk specimens with three different orientations were machined from the Cu rod for the wear test; surfaces of the disk were perpendicular ($0^{\circ}$), inclined with a specific angle ($45^{\circ}$), and parallel ($90^{\circ}$) to the extrusion axis of the rod. The texture was analyzed using an X-ray goniometer by measuring {111}, {200}, and {220} pole figures of each specimen. The analyzed texture was correlated with wear-test results of the Cu specimen. Dry sliding wear tests were performed at room temperature using a pin-on-disk wear tester against an Al2O3 ball. Applied load, sliding distance, sliding speed were fixed as 20 N, 200 m, and 0.5 m/sec, respectively. The $45^{\circ}$-inclined (to the extrusion axis) disk specimen showed the lowest wear resistance with the least data scatters. It has been found that distribution of cube texture strongly influences wear rate of the extruded Cu rod.

  • PDF

Influence of counter-bodies on the tribological behavior of diamond-like carbon coatings (상대 마찰재에 따른 DLC 코팅의 트라이볼로지적 특성평가)

  • Lee Dong Choon;Yi Jin-Woo;Kim Seock Sam
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.360-367
    • /
    • 2003
  • Diamond-like carbon(DLC) films are considerable research interest because of their widespread applications as protective coatings in areas such as optical windows, magnetic storage disks, car parts, biomedical coatings and as micro-electromechanical devices(MEMs). DLC films were deposited on WC-Co by PECVD using Ar, $C_2H_4$ gas. Tribological tests were conducted using a ball-on-disk type tribometer in dry air. Three kinds of counter-bodies balls were used. The counter-bodies balls are SM45C, SUJ2 and $ZrO_2$(3.17mm in diameter). Wear rate of the samples were calculated after measuring the worn-out volume of the wear track. As results wear test, the higher hardness of counter-bodies, friction coefficient low. As result of XPS estimation, wear debris generated as an oxide lower the friction coefficient.

  • PDF