• 제목/요약/키워드: Ball-on-3-ball test

검색결과 331건 처리시간 0.031초

플립 칩 BGA 솔더접합부의 열사이클링 피로해석 (Thermal Cycling Fatigue Analysis of Flip-Chip BGA Solder Joints)

  • 김경섭;유정희;김남훈;장의구;임희철
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2002년도 추계기술심포지움논문집
    • /
    • pp.27-32
    • /
    • 2002
  • In this paper, global full 3D finite element analysis fatigue models are constructed for flip-chip BGA on board to predict the creep fatigue life of solder joints during the thermal cycling test. The fatigue model applied is based on Darveaux's empirical equation approach with non-linear viscoplastic analysis of solder joints. It was estimated by the creep life as the variations of the four kinds of thermal cycling test conditions, pad structure, composition and size of solder ball. The shortest fatigue life of results was obtained at the thermal cycling testing condition of -65℃ ∼ 150℃. It was increased about 3.5 times in comparison with that of 0℃ ∼ 100℃. As the change of pad structure at the same other conditions, the fatigue life of SMD structure increased about 5.7% as compared with NSMD structure. Consequently, it was confirmed that the fatigue life became short as the creep strain energy density increased in solder joint.

  • PDF

음용수중의 중금속흡착과 항균성용 세라믹 볼의 제조 및 특성평가 (Preparations and characteristics of the ceramic balls for heavy metals absorption and antibacterial activities in the drinking water)

  • 박춘원;박라영;박선민
    • 한국결정성장학회지
    • /
    • 제15권6호
    • /
    • pp.263-268
    • /
    • 2005
  • [ $20{\sim}40nm$ ] 크기의 Ag 콜로이드가 첨가된 세라믹 볼을 이용하여 음용수중의 중금속 흡착 및 항균성에 대한 특성을 평가하였다. 다공성이 우수한 세라믹 볼을 제조하기 위한 조건은 다음과 같다. 즉, 출발원료: 85wt%의 $Ca_{10}(PO_4)_6(OH)_2$, 바인더: 5wt%의 PVA 및 15wt%의 $\alpha-Ca_3(PO_4)_2$, 열처리온도: $1000^{\circ}C$, 반응시간: 3시간 이었다. 이와 같은 조건에서 얻어진 세라믹 볼은 비표면적이 $110m^2/g$ 이었으며, $120{\mu}m$의 기공크기와 80%의 기공율을 나타내었다. 그리고 AAS를 이용하여 음용수중의 중금속 흡착 제거율에 대한 성능시험을 행한 결과, Zn, Mn, Cu, Fe와 같은 중금속이 담지 1일 후 0.03mg/l 이하로 제거 되었으며, 침적시간 3시간 후에는 대장균이 모두 멸균되는 우수한 살균력을 나타내었다.

RS-SiC 세라믹 재료의 강구 입자충격 손상 거동 (A Steel Ball Impact Damage Behavior of RS-SiC Ceramic Materials)

  • 오상엽
    • 대한기계학회논문집A
    • /
    • 제34권8호
    • /
    • pp.1015-1021
    • /
    • 2010
  • 본 연구에서는 반응소결 탄화규소(RS-SiC)의 제조공정 중에서 C/SiC 복합 비율(0.1, 0.3, 0.4, 0.5, 0.6, 0.7, 1.0)이 외부입자충격 손상 거동에 미치는 영향을 평가하였다. 충격시험은 공기총(air-gun)을 사용하였으며, 직경 2 mm 강구를 113 m/s, 122 m/s, 180 m/s의 충격속도로 RS-SiC 판재($20\times20\times3$ mm)에 충격시켜 발생된 링크랙의 직경 변화 및 콘크랙의 발생 거동을 SEM 영상으로 평가하였다. 결과적으로 RS-SiC에 발생한 링크랙의 최대직경이 충격속도가 증가함에 따라 대체로 증가하였지만, C/SiC 복합 비율에 따라서는 급격한 변화를 보였다. 이는 C/SiC 복합 비율에 따라 잔류 Si 함량 및 굽힘강도 변화의 영향으로 볼 수 있다. 특히 C/SiC 복합 비율이 0.4~0.5 범위에서 콘크랙이 발생됨에 따라 링크랙에서 콘크랙의 발생으로 변화되는 충격손상 메커니즘의 임계영역으로 판단할 수 있다. 아울러 콘크랙의 발생 임계영역을 고려할 때, RS-SiC 최적 제조 공정으로서 C/SiC 혼합 비율을 최대 0.3으로 하는 것이 효과적이다.

감각통합에 기초한 임상 관찰 평가의 AI 측정 기술 적용 필요성을 위한 국내 작업치료사 인식 조사 (Domestic Occupational Therapist Awareness Survey for the Need to Apply Artificial Intelligence Measurement Technology for Clinical Observation Evaluation Based on Sensory Integration)

  • 조선영;정영진;김정란
    • 재활치료과학
    • /
    • 제12권1호
    • /
    • pp.23-35
    • /
    • 2023
  • 목적 : 본 연구는 국내 감각통합치료의 임상 관찰 평가 사용실태와 세부 항목별 결과 측정의 어려움 및 중요도를 알아보고 이를 통해 임상 관찰 측정에 있어 AI 측정 기술의 적용 유용성과 세부 항목별 적용 필요도를 확인하고자 하였다. 연구 방법 : 연구 과정은 국내 작업치료사 31명에서 온라인 설문지 배포를 통해 조사 연구를 실시하였다. 설문지는 일반적 정보, 감각통합 평가 도구 사용 실태, 임상 관찰의 세부 항목별 측정의 어려움, AI 측정 기술의 유용성, 세부 항목별 평가의 중요성 및 AI 측정 기술 개발의 필요성을 조사하는 내용으로 구성되었다. 조사의 결과를 빈도분석과 기술통계를 사용하여 분석하였다. 결과 : 조사에 참여한 작업치료사들은 Sensory Profile(96.8%)을 가장 많이 사용하였고 그다음으로 임상 관찰(90.3%)을 많이 사용하였다. 임상 관찰 시 측정이 어려운 세부 항목은 Finger-to-nose Test와 Postural Control(on the 이었으며, 다음으로 Eye Movement와 Protective Extension Test(67.7%)였다. 임상 관찰 시 AI 측정 기술 적용은 83.9%의 연구 대상자들이 모두 유용할 것으로 응답하였다. AI 측정 기술 적용이 필요하다고 응답한 가장 높은 항목은 Postural Control(on the ball)(90.3%)이었고, 다음으로 Eye Movement(83.9%), Prone Extension과 Protective Extension Test(77.4%) 순으로 나타났다. 결론 : 본 연구의 결과는 국내 아동 작업치료 현장에서 임상 관찰이 중요한 평가도구이며 임상 관찰 평가의 측정 정확성을 향상하기 위해서 AI 기술 적용이 필요하다는 작업치료사들의 인식을 확인할 수 있었다.

리플로우 횟수가 ENIG/Sn-3.5Ag/ENIG BGA 솔더 조인트의 기계적, 전기적 특성에 미치는 영향 (Effect of Multiple Reflows on Mechanical and Electrical Properties of ENIG/Sn-3.5Ag/ENIG Ball Grid Array (BGA) Solder Joint)

  • 성지윤;표성은;구자명;윤정원;노보인;원성호;정승부
    • 마이크로전자및패키징학회지
    • /
    • 제16권1호
    • /
    • pp.7-11
    • /
    • 2009
  • 본 연구에서는 electroless nickel / immersion gold (ENIG) 처리된 printed circuit board (PCB)를 무연 솔더인 Sn-3.5(wt%)Ag로 접합하였다. 리플로우 횟수를 1회부터 10회까지 다양하게 하여 리플로우 횟수가 증가함에 따른 솔더 접합부의 기계적, 전기적 특성의 변화에 대해 연구하였다. 접합부의 미세 조직 관찰을 위해 접합부 단면을 폴리싱 하여 금속간 화합물의 두께를 측정하고 종류를 분석하였다. 접합부의 기계적 특성을 평가하기 위해서 die 전단 시험을 하였는데, 리플로우 횟수가 4-5회일 때까지 전단 강도 값이 증가하다가 5회 이후로 감소하였다. 전기적 특성을 알아보기 위해 전기 저항 값을 측정하였는데, 리플로우 횟수가 증가할수록 접합부의 전기 저항 값은 점점 증가하였다.

  • PDF

탄소강의 펄라이트 분율에 따른 미끄럼 마멸속도 편차 분석 (Analysis of Mean Deviation in Sliding-wear-rate of Carbon Steel with Various Pearlite Volume Fractions)

  • 김명곤;권혁우;허하리;김용석
    • 소성∙가공
    • /
    • 제24권3호
    • /
    • pp.205-211
    • /
    • 2015
  • The current investigation was performed to study sliding-wear-rate deviation (wear-rate data scatter) in carbon steels with various microstructures. Pure iron, 0.2 wt. % C steel, 0.45 wt. % C steel, and bearing steel (AISI52100) were used for the investigation. These steels possess different microstructures. Microstructures of the pure iron, two carbon steel and the bearing steel were full ferrite, ferrite + pearlite and full pearlite, respectively. Depending on the carbon content, the carbon steel had different pearlite-volume fractions. Dry sliding wear tests of the steel were conducted using a ball-on-disk wear tester at a sliding speed of 0.1 m/s using a bearing ball (AISI52100) as a counterpart. Applied load and sliding distance were 100 N and 300 m, respectively. More than three (up to twelve) tests were conducted for each steel under the same conditions, and the mean deviations in the wear rate of the steel (microstructure) were compared. The wear-rate deviation in the steel with ferrite + pearlite microstructure was higher than that with ferrite microstructure, and the deviation decreased with the increase of pearlite volume fraction. The pure iron and the bearing steel specimens showed much less deviation. The high deviation observed from the ferrite + pearlite steel was attributed to irregular subsurface-crack nucleation and growth at the interface between the two micro constituents (ferrite and pearlite) during the wear test.

성인 여성의 발 형태 분석에 관한 연구 (A Study on Foot Shape of Women)

  • 서추연;석은영
    • 대한가정학회지
    • /
    • 제41권6호
    • /
    • pp.1-12
    • /
    • 2003
  • The purpose of this study were to analyze the anthropometric data of feet of Korean women with aging, to categorize the women's foot shapes, and to compare the shoe size according to the foot shapes in order to provide the basic information for more comfortable shoes. Subjects of this study were 181 women over age 20. They were measured with the direct measurement method and the indirect measurement method. 26 items were measured from the right foot and 6 items were taken on foot outline. Factor analysis, cluster analysis, analysis of variance, post-hoc test, and cross tabs were peformed for statistical analysis of the data by SPSS program. There were significant differences in height items, breadth items, girth items, and angle items by subjects' age. The older subjects' feet were wide and thick with big deformity on toes. The arch height of the older ones was low. This implicates that the degree of deformity on toes, the foot ratio, the foot girth, the foot breath and the arch height as well as the foot length are needed to be considered in developing comfortable shoes. Nine foot construction factors were extracted by the factor analysis of anthropometric measurements; foot size factor, heel and instep factor, malleolus lateralis factor, malleolus medialis factor, foot shape factor, shape of toes factor, heel height factor, big toe height factor, and internal factor. On the basis of the cluster analysis, three different foot shapes were categorized. Type 1 was large and wide foot with little deformity on little toe. Type 2 was medium foot with deformation of big toe, and with the lowest arch height. Type 3 was small and narrow foot with the highest arch height. Distribution of shoe size according to the foot shape was analyzed. The ball of foot breath was of wide distribution than the ball of foot girth. This implicates that girth items and breath items of the foot should be enclosed for the same foot length in the shoe sizing system.

교반 볼밀에 의한 방해석, 납석, 활석의 분쇄 시 분쇄속도론에 관한 연구 - 선택함수의 고찰 (Grinding Kinetics of Calcite, Pyrophyllite and Talc During Stirred Ball Milling - Consideration of Selection Function)

  • 최희규;김성수;황진연
    • 한국광물학회지
    • /
    • 제20권2호
    • /
    • pp.135-145
    • /
    • 2007
  • 최근 서브미크론 영역의 초미분쇄는 세라믹, 전자재료 등 새로운 기능성 물질의 개발과 더불어 매우 중요하게 인식되고 있다. 특히, 초미립자에 대한 수요증가에 따라 분쇄기로서 교반볼밀의 중요성도 증가하고 있다. 본 연구에서는 1 mm의 볼을 사용하고 700 rpm의 회전속도로 조작한 교반볼밀을 이용하여 방해석, 납석, 활석 등의 무기분말을 시료로 분쇄실험을 행하였다. 무기분말의 분쇄 시, 분쇄 특성의 정량적인 규명을 위하여, 입자의 크기 및 그 분포특성의 분석을 통해 분쇄산물의 입도분포를 얻음과 동시에 중위경의 변화를 관찰하였다. 방해석의 경우 원시료의 중위경이 $6.49{\mu}m$에서 $0.47{\mu}m$로, 납석의 경우 $3.91{\mu}m$에서 $1.14{\mu}m$까지 입자크기가 크게 작아졌으나, 활석의 경우 $10.30{\mu}m$에서 $6.67{\mu}m$까지만 작아져서 많은 변화를 보이지 않았다. 또한, 분쇄산물의 여러 가지 측정 결과를 토대로 분쇄조작 시 분쇄산물의 특성이 분쇄조건에 따라 분쇄속도에 미치는 영향을 알고자 하였다. 같은 실험 조작 조건에서 선택함수를 관찰한 결과, 방해석과 납석은 비슷한 분쇄거동을 보이는 것을 알 수 있었으나, 본 실험범위 내에서 활석의 분쇄거동은 크게 변화하지 않는 것이 관찰되었다.

탄성파 충격공지법에 의한 기초 콘크리트의 두께 측정 (Thickness Measurements of the Base Concrete by the Impact-Resonance Test)

  • 김영환;이세경;김호철
    • 콘크리트학회지
    • /
    • 제3권3호
    • /
    • pp.121-128
    • /
    • 1991
  • 시험체의 공지모드를 분석하여 대형 기계용 기초 콘크리트의 두께를 측정하였다. 시험체에 강철구 자유낙하에 의한 기계적인 충격을 가하여 진동을 발생시키고, 이 진동신호를 광대역 원추형 압전 탑촉자로 수신하였다. 수신된 진동신호를 FFT를 사용하여 주파수로부터 시험체의 두께를 결정하였다. 여러 층으로 이루어진 콘크리트 블록의 경우, 이 방법으로 결정된 값은 실제의 두께와 잘 일치하였다. 또한 이 방법은 두께 측정 뿐만 아니라 경계면의 접합 상태 파악에 활용될 수 있다.

니켈기 경질 용사코팅의 마모거동에 미치는 공정조건의 영향 (Effects of Process Parameters on the Wear Behavior of Thermally Sprayed Ni-based Hard Coatings)

  • 김균택;김영식
    • Tribology and Lubricants
    • /
    • 제26권3호
    • /
    • pp.157-161
    • /
    • 2010
  • This study investigated the effects of spray parameters on wear behavior of the Ni-based hard coatings fabricated by thermal spray process. The experiment was designed by an orthogonal array, the Ni-based hard coatings were fabricated according to this experimental design. The wear test was performed on these coatings using ball-on-disk wear tester. The ANOVA was used to analyze the effects of spray parameters on the wear rate of these coatings, as a result, oxygen gas flow and acetylene gas flow were determined as main factors effected on the wear rate. The effects of these two factors on wear behavior were observed by using SEM and EDX.