• 제목/요약/키워드: Ball valve

검색결과 111건 처리시간 0.031초

극한지 자원이송망 볼밸브 수치모델 및 성능평가장치 개발 (Development of Numerical Model and Experimental Apparatus for Analyzing the Performance of a Ball Valve used for Gas Pipeline in Permafrost Area)

  • 이상문;장춘만
    • 한국수소및신에너지학회논문집
    • /
    • 제25권5호
    • /
    • pp.550-559
    • /
    • 2014
  • Hydraulic performance of the 1 inch ball valve have been analyzed based on the three-dimensional Reynolds-averaged Navier-Stokes analysis and an experiment. The experimental test rig of the 1 inch ball valve has been developed to investigate pressure drop for the 1 inch ball valve. The numerical model, which has reliability and effectiveness, has been constructed through the grid dependency test and validation with the results of the experiment. Shear stress transport turbulence model has been used to enhance an accuracy of the turbulence prediction in the pipeline and ball valve, respectively. Effects of the ball valve angle on the flow characteristics and friction performance have been evaluated.

개도율에 따른 가스파이프라인용 볼 밸브 후류유동의 수치평가 (Numerical Evaluation of Flow Nature at the Downstream of a Ball Valve Used for Gas Pipelines with Valve Opening Rates)

  • 김철규;이상문;장춘만
    • 한국수소및신에너지학회논문집
    • /
    • 제29권4호
    • /
    • pp.370-377
    • /
    • 2018
  • Ball valve has been widely used in the field of high-pressure gas pipeline as an important component because of its low flow resistance and good leakage performance. The present paper focuses on the flow nature at the downstream of the ball valve used for gas pipelines according to valve opening rates. Steady 3-D RANS equations, SC/Tetra, have been introduced to analyze the flow characteristics inside the ball valve. Numerical boundary conditions at the inlet and outlet of the valve system are imposed by mass flow-rate and pressure, respectively. Velocity distributions obtained by numerical simulation are compared with respect to the valve opening rates of 30, 50, and 70%. Cavity distributions, asymmetry flow velocity and the flow stabilization point at each opening rate are also compared. When the valve opening rates are 30 and 50%, the flow stabilization requires the sufficient length of 10D or more due to the influence of the recirculation flow at the downstream of the valve.

유동상사를 이용한 10인치 볼밸브 내부유동 분석 (Internal Flow Analysis for a 10 inch Ball Valve using Flow Similarity)

  • 이상문;장춘만
    • 한국수소및신에너지학회논문집
    • /
    • 제26권4호
    • /
    • pp.386-392
    • /
    • 2015
  • Flow characteristics inside a 10 inch ball valve have been analyzed using three-dimensional numerical analysis and experiments. Continuity and three-dimensional Reynolds-averaged Navier-Stokes equations have been used as governing equations for the numerical analysis. The numerical model has been constructed through the grid dependency test and validation with the results of experiments to ensure reliability and numerical effectiveness. The shear stress transport (SST) model has been used as the turbulence closure. The experimental test-rig has been constructed to measure pressure, temperature and flow rate along the pipeline. Some valve opening angles have been tested to evaluate the flow characteristics inside the ball valve and pipeline. The results show that the rapid pressure variations is observed while the valve opening angle decreases, which caused by flow separation at the downstream of the ball valve.

수소 충전소용 초고압 볼밸브 설계에 관한 연구 (A Study on Design of Ultra-High-Pressure Ball Valve for Hydrogen Station)

  • 최지아;지상원;장지성
    • 드라이브 ㆍ 컨트롤
    • /
    • 제18권3호
    • /
    • pp.23-29
    • /
    • 2021
  • Hydrogen energy is the clean energy source of the future. Ultra-high-pressure hydrogen is used in hydrogen stations, with its parts being developed. On the other hand, ultra-high-pressure ball valve, which is one of its parts, depends on overseas, with the level of domestic research on this being only about 10% of advanced technology research on this abroad. In this study, the shape of an ultra-high-pressure ball valve for a hydrogen station was designed to improve its structural strength. The valve body was designed according to distance between both processed body holes along inlet and outlet ports. The designed vale body was then analyzed using ANSYS to check whether points with stress were concentrated. In addition, the valve with improved body was analyzed to confirm that the valve satisfied the design condition.

화울링 저감을 위한 분체용 볼 밸브의 개발 (Development of the Fouling-Controlled Ball Valve Used for Gas-Solid Flow)

  • 이찬;원영식
    • 청정기술
    • /
    • 제11권4호
    • /
    • pp.181-188
    • /
    • 2005
  • 밸브 내부의 입자들의 화울링 현상의 제어 및 저감을 위해 공기분사 방식을 적용하는 새로운 분립체용 볼 밸브를 개발하였다. 밸브 내부의 분립체와 분사공기 흐름간의 상호작용 및 화울링 현상에 대한 규명을 위해 전산유체역학적 해석을 수행하였고, 해석결과들을 밸브 형상 및 공기분사 조건 설계에 반영하였다. 설계된 분립체용 볼 밸브의 실제 시험을 통해, 본 볼 밸브가 여러 운전 조건들에 대해서 우수한 화울링 저감효과를 가짐을 알 수 있었다.

  • PDF

화력발전소용 1인치 볼 밸브 유량계수 Cv에 관한 유동해석 및 실험에 관한 연구 (Experiment and Flow Analysis of the Flow Coefficient Cv of a 1 inch Ball Valve for a Thermal Power Plant)

  • 강창원;이중섭;이치우
    • 한국기계가공학회지
    • /
    • 제18권3호
    • /
    • pp.109-115
    • /
    • 2019
  • The purpose of this study was to analyze and test the flow rate of a 1-inch ball valve used in a thermal power plant. To identify the flow-rate characteristics, numerical analysis was conducted and an experimental apparatus of the valve flow rate coefficient was used to compare the flow coefficient Cv values. To determine the internal pressure distribution, the sites of opening ball valves and flow fields were investigated. In particular, a smaller the valve opening resulted in a more complicated the flow field of the ball. The valve flow characteristic test showed that the Cv value and flow rate increased with increasing valve-opening rate and the secondary function was performed. The pressure drop increased as the valve opening rate decreased. In addition, the experimental results for the flow analysis are similar to the numerical analysis results.

상류곡관에 의한 볼밸브 내부유동 영향성 연구 (A Study on Influence of Ball Valve and Upstream Curved Pipe on Internal Flow of Pipeline)

  • 조철희;김명주;조석진;황수진
    • 한국수소및신에너지학회논문집
    • /
    • 제26권5호
    • /
    • pp.463-468
    • /
    • 2015
  • This study describes the effect of upstream curved pipe on internal flow characteristics ball valve. Continuity and three-dimensional Reynolds-averaged Navier-Stokes equation have been used as governing equations for the numerical analysis. The upstream curved pipe - ball valve model was assumed that it is used for Alaska pipeline project which was planned to provide reliable transportation of natural gas from ANS to Alaska-Yukon border. Therefore the characteristics of pipe and operating condition of pipeline were from report of Alaska pipeline project. The three curvature and three location of upstream curved pipe were analyzed. The results shows that there are typical flow patterns at ball valve and the upstream curved pipe makes some differences to the internal flow of ball valve.

개폐각도에 따른 PFA 라이닝 볼밸브의 유동특성 및 유랑계수 전산해석 (CFD Analysis on the Flow Characteristics with Flow Coefficient in a PFA Lined Ball Valve for Different Opening Degrees)

  • 전홍필;김동열;이종철
    • 한국유체기계학회 논문집
    • /
    • 제17권4호
    • /
    • pp.76-80
    • /
    • 2014
  • PFA fluoropolymer lined technology revolutionized ball valve development and design decades ago and continues to be pivotal for many products and valve solutions in diverse industries and applications, such as chemical process, semiconductor/LCD manufacturing processes, pharmaceutical and others. Because of the extreme operating conditions such as high-temperature (${\sim}120^{\circ}C$) and high-pressure (~10 bar), the reliability of the valve is very important for minimizing in-line leakage and fugitive emissions of strong corrosive chemicals (hydrochloric acid, hydrofluoric acid, nitric acid, etc.) transported through the lines. In this study, we investigated the flow characteristics with flow coefficient in a PFA lined ball valve for different opening degrees using CFD analyses. The results should be the guidance for a new PFA lined ball valve design that will incorporate all the acclaimed and demonstrated benefits of the current design approaches.

석유화학용 Ball Valve 유동 및 강도 수치해석 (A Numerical Analysis on Flow and Strength of Ball Valve for petrochemistry)

  • 이중섭;정휘원;장성철;남태희;박중호;윤소남
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.357-362
    • /
    • 2008
  • This study have goal with reverse engineering for petrochemistry of high pressure ball valve for localization. Ball valve for development accomplished with flow analysis based on provision of ANSI B16.34, ANSI B16.10, ANSI B16.25 In order to localize the petrochemistry high pressure control valve. Numerical simulation using CFD(Computational Fluid Dynamic) in order to predict a mass flow rate and a flow coefficient form flow dynamic point of view. The working fluid assumed the water($H_2O$). The valve inlet and outlet setup a pressure boundary condition. The outlet pressure was fixed by atmospheric pressure and calculated inlet velocity 5m/s. CFD solver used STAR-CCM+ which is commercial code. The result shows change of mass flow rate according to opening and closing angle of valve. Flow decrease observed open valve that equal percentage flow paten which is general inclination of ball valve. The structural analysis used ANSYS which is a commercial code. Stress analysis result of internal pressure in valve showed lower than yield strength. This is expect to need more detail design and verification for stem and seat structure.

  • PDF

개폐 각도에 따른 볼 밸브에서의 유동 해석에 관한 연구 (A Study on Flow Analysis at Ball Valve according to Opening and Shutting Angle)

  • 조재웅;한문식
    • 한국기계가공학회지
    • /
    • 제10권2호
    • /
    • pp.46-51
    • /
    • 2011
  • This study result is obtained by flow analysis according to opening and shutting angle of ball valve. As opening and shutting angle becomes larger, vortex flow becomes smaller and flow rate becomes increased. And the pressure drop is shown to be smaller at the inlet and outlet of ball. As this angle becomes larger, mass flow rate becomes increased. Its rate becomes increased abruptly in case of opening and shutting angle at more than $60^{\circ}$.This analysis result can be applied usefully with no leak at pipe system field by the optimum control of mass flow rate according to opening and shutting of ball valve.