• Title/Summary/Keyword: Ball valve

Search Result 111, Processing Time 0.026 seconds

Implementation of Wireless Micro-Magnetic Detection System in the Conveyer Belt (컨베어 이송장치에서의 무선 미소자기감지 시스템 구현)

  • Lee, Young-Dong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.12
    • /
    • pp.2975-2981
    • /
    • 2014
  • Micro-magnetic detection system is used to detect small particles in an automatic transmission valve body, which signal noise and time-delay may occurs in process of signal transmitting and filtering. In this paper, we present the design and implement of a micro-magnetic detection system based on wireless sensor networks in conveyer belt. Micro-magnetic detection system consists of five modules which are magnetic sensor detector, signal processing unit, wireless sensor networks, system control unit and system monitoring unit. Our experimental results show that the proposed wireless micro-magnetic detection system improves both accuracy and time delay compared to the wired system; therefore, it may apply for wireless micro-magnetic detection system by analysis of packet reception rate.

A Design and Implementation of Process Controller for BMW (Bacteria Mineral Water) Plant (비엠 활성수 플랜트의 공정제어기 설계 및 구현)

  • Lee, Sang-Yun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.2
    • /
    • pp.74-82
    • /
    • 2015
  • In this study, a BMW plant process control system model which produces BMW is suggested and the BMW plant process controller with the following functions is developed. The first function is to operate the electronic overload relays to stop the blower for a certain period of time and to re-operate it again when the blower is overloaded. The second function is to close the motor operated valve automatically in case of power failure to prevent the circulation from the guided tank to the compost throwing tank and to block leak from the compost throwing tank due to the failure of ball valve. The third function is to transfer produced BMW from the concentration tank to 4 storage tanks for automatic managing of the BMW output. A device to measure the signal of the BMW plant process controller and a test equipment are developed. The designed BMW plant process controller is checked to see if it operates correctly according to the design specifications. The sequence control method based on BMW plant process controller is developed at a low cost in this study, so it is expected to bring improvements in the stability and the efficiency of system and to cause reductions in the operation and the management costs in the future.

NUMERICAL ANALYSIS ON INTERNAL FLOW OF OIL JET COOLING THE PISTON (피스톤 냉각용 Oil jet 유동해석)

  • Kwon J.H.;Jung H.Y.;Lee J.H.;Choi Y.H.;Lee Y.W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.219-222
    • /
    • 2005
  • Recently, the interest of the engine capacity and environment of the atmosphere is increasing, so the researches for the engine capacity have been conducted for a long time. But the internal environment of an automotive engine is very severe. A piston is exposed to combustion gas of over $2000^{\circ}C$ and strong friction is occurred by high speed motion in the cylinder. The fraction between piston and wall of the cylinder causes the increase of temperature in the engine. The temperature of the engine has an effect on the engine capacity. If the temperature is high, the capacity of the engine is low. So we have to maintain the optimum temperature. To maintain the optimum temperature, the enough flow rate of the engine oil is needed. The oil jet is used to control the flow rate of the engine oil and supply the engine oil to the piston and cylinder. The purpose of this study is to check the mass flow rate of the engine oil and the characteristics of internal flow of the oil jet. Flow pattern of the engine oil is very important because it concludes the loss in the oil jet. This study is the previous research about the oil jet and we will consider the movement of the ball check valve to get more accuracy result.

  • PDF

Design of POGO Supporession Device Performance Test System (POGO 억제장치 성능 시험기 설계)

  • Lee, Han-Ju;Kim, Ji-Hun;Jeong, Dong-Ho;O, Seung-Hyeop
    • Aerospace Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.181-187
    • /
    • 2006
  • The present study deals with the experimental facility for PSD (POGO Suppression Device) performance test systems. Basically there are two methods to pulsate the system; whole-feeding-system pulsation and working-fluid pulsation. The latter method adopts either a piston-type pulsator or a restrict-type pulsator. The working-fluid pulsation using a restrict-type pulsator was considered to be the most appropriate experimental system to study the effects of the primary parameters, and a practical design of the system was proposed. Also, the experimental facility adopts the ball valve type pulsator considering the leak problem of the plate type pulsator.

  • PDF

Emergency Neuroendoscopic Management of Third Ventricular Neurocysticercosis Cyst Presented with Bruns Syndrome : Report of Two Cases and Review of Literature

  • Teegala, Ramesh;Rajesh, K. Ghanta;Raviprasad, V. Yerramsetty;Chennappa, Yemba
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.3
    • /
    • pp.173-177
    • /
    • 2014
  • Neurocysticercosis is the commonest parasitic disease of the human central nervous system. The incidence of intra ventricular form of neurocysticercosis (NCC) is less common accounting 10-20% that of total central nerve system cysticercosis. Intra ventricular NCC is complicated due, to its high incidence of acute hydrocephalus caused by ball valve mechanism. The only reliable tool for diagnosis of NCC is by neuroimaging with CT or MRI. MRI preferred over CT because of its high specificity and sensitivity. In emergency situations like acute hydrocephalus one can proceed with emergency endoscopic surgery. Through the endoscopic view, intra ventricular NCC (IVNCC) has distinguished morphological features like the full moon sign. This feature not only helps in identification of IVNCC, but also guides in further endoscopic treatment strategy. Authors report two cases of 3rd ventricular NCC with acute hydrocephalus managed with emergency endoscopy. Authors have discussed the clinical features, intra operative endoscopic findings and role of endoscopy in emergency surgery for NCC with acute hydrocephalus.

The Resistance Characteristics and Reliability Evaluation of an Insulation Ring Type of Corrugated Stainless Steel Tubing(CSST) (절연링형 금속플렉시블호스(CSST)의 저항 특성 및 신뢰성 평가)

  • Lee, Jang-Woo;Kim, Jeom-Sik;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.25-31
    • /
    • 2016
  • This paper has analyzed the structure, applicable regulations and the resistance characteristics of insulation ring type of CSST (Corrugated Stainless Steel Tubing for Gas). With the flammability test conducted in accordance with KS C IEC 60811-1-1, the evaluation of insulation resistance, temperature characteristics, and reliability has been conducted. An insulation ring type CSST consists of protective coating, tube, nut, insulation ring, packing, socket, and ball valve. Connecting an insulation ring type CSST to gas tubings for gas appliance is not permitted, moreover, the product shall be installed inside a sleeve pipe in case of buried installation such as the ceiling. Damages on protective coating and tube were detected when fire was applied to the test sample with a portable torch for 60 seconds. The insulation resistance of a normal product was $49.59M{\Omega}$, while that of the product completed the flammability test reduced to $9.21M{\Omega}$. The mean insulation resistance within the confidence Interval of 95% using the mini tap program 17 was $49.59M{\Omega}$ and the mean insulation resistance within the confidence interval reduced to $9.21M{\Omega}$. In the normal distribution analysis of 95% confidence interval, the value-P of the normal product was stable at 0.075 and AD(Anderson-Darling) statistic value was turned out to be 0.063, which is very normal, and the standard deviation was analyzed as 0.2586. The value P of the product completed the flammability test resulted in 0.005, the AD was 1.355 and the standard deviation reduced to 0.07908.

Development of an electronic sow liquid feeding system using RFID (1) - Development and performance test of the prototype - (RFID이용 전자식 모돈 개체별 액상급이기 개발(1) - RFID를 이용한 모돈 액상급이기 제작 및 성능시험 -)

  • Kim, Hyuck Joo;Hong, Jong Tae;Yu, Byeong Kee;Kim, Sang Cheol;Choi, Kyu Hong;Chang, Hong Hee
    • Journal of Biosystems Engineering
    • /
    • v.37 no.6
    • /
    • pp.373-384
    • /
    • 2012
  • Purpose: In EU, the animal welfare regulations are strengthening. Also, in Korea, for strengthening of animal protection laws, animal welfare farm certification scheme is being prepared to enforce. To get the certification of animal welfare farm, especially for sows, individual specific feeding in sow group is necessary in accordance with the animal welfare regulation. Also, liquid feeding is reported to be more effective for farrowing as well as dry sow. Therefore, in this study, a electronic liquid sow feeder using RFID which could be fed to farrowing sow simultaneously is developed. Methods : We manufactured a prototype of appropriate elements which were evaluated in the preliminary test for selecting RFID tag, supply pump, mixing type, etc. With the prototype, the performance test for liquid feeding gilt was done in group raising training barn. Results : The performance test result shows the C.V.(coefficient of variation) of liquid mixing and feeding is 0.77~1.97% and 2.4~5.3%, respectively, which means the system could feed sows uniformly. The feeding time of pneumatically activated ball valve is 2 seconds per 0.9 kg of liquid feed. The eating time for gilt were 65 seconds in average. Conclusions : The prototype could feed sow uniformly, and deliver the liquid feed 9 times for a sow continuously. Also, total eating time for a sow was 18 minutes in one visit to the prototype of feeding station.

Prostatic Urethral Polyp Causing Lower Urinary Tract Obstruction: Report of A Case (하부요로폐쇄를 일으킨 전립선부 요도폴립 1례)

  • Lee, Dong-Heon;Suh, Jun-Kyu;Kim, Young-Soo;Park, Tong-Choon;Nam, Hae-Joo;Choi, Won-Hee;Lee, Tae-Sook;Lee, Kyung-Chul
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.249-252
    • /
    • 1985
  • Polyps of the male urethra are relatively uncommon lesions. They usually arise from the prostatic urethra mostly verumontanum or Just lateral to the verumontanum. Posterior urethral polyp often presents with hematuria, hemospermia and sometimes lower urinary tract obstruction. We recently experienced a pedunculated prostatic urethral polyp in a 63-year-old man who complained of gross total hematuria and difficult micturition for several years. On rectal examination the prostate was slightly enlarged with normal consistency. Excretory urogram showed a round filling defect in the right side of the bladder neck measuring about $2{\times}2cm.$ in size. Cystourethroscopy revealed trabeculation of the vesical wall, mild bilateral prostatic hypertrophy and a round cystic mass with a long stalk arising from the prostatic floor 1 cm. Proximal to the verumontanum which caused ball-valve obstruction in the bladder neck. This pedunculated polypoid mass was then resected at its base with resectoscope and was removed transurethrally using Lowsley's grasping forceps. The specimen was proved as fibrous polyp histologically.

  • PDF

Tele-operation System of Unmaned Fire Truck for Real-time Fire Suppression (실시간 화재진압을 위한 원격조종 무인소방 시스템)

  • Kang, Byoung Hun;Lee, Seung-Chol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.6
    • /
    • pp.1-6
    • /
    • 2022
  • In this research, we suggest a real-time tele-driving system for unmanned fire truck control using the LTE communication system. The operator located in the safe area could drive the unmaned fire truck by implementing the secure tele-operation in case of the emergencies and disaster situation. A prototype of the unmaned fire truck was developed with a fire canon, a high pressure pump, a ball valve and a horse reel. The effect of time delay and FPS was quantified depending on the image sizes and the effective system for realtime tele-operation was suggested. To verify the suggested system, the test was performed between an operator and an unmanned fire truck which is approximately 30km apart. In this research, the immersion tele-driving system is suggested for real-time fire suppression with a 120ms time delay using LTE communication.

A Study on the Properties Analysis of an Iron Fittings Type CSST Damaged by the PCITS (PCITS에 의해 소손된 강이음쇠형 CSST의 특성 해석에 관한 연구)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.121-127
    • /
    • 2016
  • This study analyzed the structural and electrical characteristics of an iron fittings type Corrugated Stainless Steel Tubing (CSST) damaged by the Primary Current Injection Test System (PCITS). CSST consists of cladding, tube, nuts, clamp ring, flare cap, socket, and ball valve. For an evaluation of the dielectric withstand voltage, the area between the live part and non-live part of the CCST shall withstand a voltage of 220 V AC for one minute. For an evaluation of the insulation performance by 500 V DC, it is required that the insulation exceed more than $1M{\Omega}$ before the temperature rise test, $0.3M{\Omega}$ after the test. Although the average resistance of the product was $11.5m{\Omega}$, that of the product damaged at a current of 130 A by the PCITS was $11.50m{\Omega}$. Furthermore, parts of the cladding were melted and black smoke appeared when a current of 130 A applied for 10 s. After 60 s, most parts were heated and turned red. At 120 s, the parts that turned red had widened. Although it did not form a normal distribution because the P value was 0.019 with a confidential interval of 95%, it revealed outstanding characteristics with an AD (Anderson-Darling) value of 0.896 and a standard deviation of 0.5573.