• Title/Summary/Keyword: Balance weight device

Search Result 27, Processing Time 0.018 seconds

Postural Control in Brain Damage Patients According to Moving Surround (뇌기능 장애 환자의 가상영상(Moving Sorround) 자극에 따른 자세 균형 제어)

  • 김연희;최종덕;이성범;김종윤;이석준;박찬희;김남균
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.11a
    • /
    • pp.233-244
    • /
    • 2002
  • The purpose of this study is to assess the ability of balance control in moving surround using head mount device and force platform and to examine the clinical usefulness of COP parameters. Fifteen patients with stroke and healthy persons were participated. COP parameters were obtained as total path distance, frequency of anterior-posterior and medial-lateral component by FFT analysis, weight-spectrum analysis in the two different conditions; (1) in comfortable standing with opened or closed eyes, (2) in virtual moving surround delivered using HMD to four different moving pattern. In virtual moving surround setting, moving pattern was composed of close-far, superior-inferior tilting(pitch), right-left tilting(roll) and horizontal rotation(yaw) movement. In all parameters, the reliebility of COP analysis system was significantly high. Also, the construct validity compared between fifteen patients with stroke and normal persons was excellent in virtual moving surround condition(p

  • PDF

Children서s Understanding on Scientific Units in Elementary School Science Textbooks (초등학교 과학 교과서에서 사용되는 단위에 대한 아동들의 이해도)

  • 김성규;서승조;조태호;백남권;박강은;공정선
    • Journal of Korean Elementary Science Education
    • /
    • v.21 no.2
    • /
    • pp.201-212
    • /
    • 2002
  • This paper aims to find out how did elementary students understand scientific units in science textbooks. The subjects were 191 students of the 6th grade from 7 elementary schools in 3 different areas, consisting of 70 from 4 village schools of, 64 from 2 town schools of Gyeongnam province, and 57 from one city school in Ulsan Metro City. A test was developed based on the analysis of scientific units in the science textbooks and teacher's manuals constructed according to the 6th and 7th National Science Curriculum. The understanding of elementary students' on the scientific units(Temperature, Length, Weight, Volume, Speed, Plane Angle) were surveyed. The result are as follows: Regarding the temperature unit, the students generally well understand why to measure and how to read temperature, but had some problem in recording it, in confusion with the plane angle sign. As for the length unit, they obtained high scores in understanding the purpose of measuring length as well as recording and reading it. Which indicates that they are well aware of and use the unit appropriately. With respect to the weight unit, they got high scores in reading and recording weight, which means most students have no problem using the unit. However, it was found that they do not understand why to use the plate balance scale. The volume unit was one in which the students got relatively lower scores. They do not perceive the object of using a scale cylinder and confuse it with a device of length measurement. The unit of speed is the most difficult one for children's of science to understand, presumably, because it is an derived unit from two basic units. It is also assumed that the students got the highest score in the plane angle unit because they studied the unit immediately before the test. From the children's understanding of science units above the teacher's understanding and teaching methods presumed to play a major role for children to understand and use the science units properly.

  • PDF

The Study on Analysis of Muscle Activity during Sling Squat Exercise according to Rope Type (로프 타입에 따른 슬링을 이용한 스쿼트 운동 시 근육의 활성화 비교 분석)

  • Woo, Hyun Ji;Kwon, Tae Kyu
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.4
    • /
    • pp.311-319
    • /
    • 2020
  • Objective: The purpose of this study was to examine of this study is to study the effect of squat exercise on muscle activation in a sling device using various types of ropes and to propose an effective sling exercise method for strengthening the lower extremity strength. Method: 20 adult male subjects (age: 25.2±2.4 yrs, height: 176.5±3.2 cm, weight: 77.2±4.5 kg) participated in this study. In the experiment, a total of four squats were conducted: squat [SE], sling squat using inelastic rope [IR], sling squat using elastic rope [ER], and sling squat using two elastic ropes [TER]. Squats were performed 5 times for each condition, and a 60-second break was given for each condition to minimize muscle fatigue. The activation of biceps brachii, rectus femoris, gastrocnemius, and tibialis anterior muscles was measured. Results: It was found that the activation of all muscles was the lowest during the squat exercise [SE]. During the sling squat using inelastic rope [IR], the muscle activation of the biceps brachii was the highest. During the sling squat using elastic rope [ER], the activation of the rectus femoris, gastrocnemius, and tibialis anterior muscles was found to be the highest. In the sling squat using two elastic ropes [TER], most of the muscle activation was similar to that of the sling squat using inelastic rope [IR]. Conclusion: Our results of the experiment, it was found that sling squat exercise using elastic rope had a positive effect on the activation of all muscles. It is thought that performing a squat exercise under moderate weight load and unstable conditions, such as sling squat exercise using elastic rope, can increase the muscle activity of the lower limbs and perform more effective exercise effect than performing a conventional squat exercise under stable conditions. In the future, if research is conducted not only on adult men, but also on various ages and patients, it will be able to provide positive help in improving balance, stability and stamina through squat exercise.

Activity and Safety Recognition using Smart Work Shoes for Construction Worksite

  • Wang, Changwon;Kim, Young;Lee, Seung Hyun;Sung, Nak-Jun;Min, Se Dong;Choi, Min-Hyung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.2
    • /
    • pp.654-670
    • /
    • 2020
  • Workers at construction sites are easily exposed to many dangers and accidents involving falls, tripping, and missteps on stairs. However, researches on construction site monitoring system to prevent work-related injuries are still insufficient. The purpose of this study was to develop a wearable textile pressure insole sensor and examine its effectiveness in managing the real-time safety of construction workers. The sensor was designed based on the principles of parallel capacitance measurement using conductive textile and the monitoring system was developed by C# language. Three separate experiments were carried out for performance evaluation of the proposed sensor: (1) varying the distance between two capacitance plates to examine changes in capacitance charges, (2) repeatedly applying 1 N of pressure for 5,000 times to evaluate consistency, and (3) gradually increasing force by 1 N (from 1 N to 46 N) to test the linearity of the sensor value. Five subjects participated in our pilot test, which examined whether ascending and descending the stairs can be distinguished by our sensor and by weka assessment tool using k-NN algorithm. The 10-fold cross-validation method was used for analysis and the results of accuracy in identifying stair ascending and descending were 87.2% and 90.9%, respectively. By applying our sensor, the type of activity, weight-shifting patterns for balance control, and plantar pressure distribution for postural changes of the construction workers can be detected. The results of this study can be the basis for future sensor-based monitoring device development studies and fall prediction researches for construction workers.

Experimental Study Of Supersonic Coanda Jet

  • Kim, Heuydong;Chaemin Im;Sunhoon, Woo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.33-33
    • /
    • 1999
  • The Coanda effect is the tendency for a fluid jet to atach itself to an adjacent surface and follow its contour without causing an appreciable flow separation. The jet is pulled onto the surface by the low pressure region which develops as entrainment pumps fluid from the region between the jet and the surface. Then the jet is held to the wall surface by the resulting radial pressure gradient which balance the inertial resistance of the jet to turning. The jet may attach to the surface and may be deflected through more than 180 dog, when the radius of the Coanda surface is sufficiently large compared to the height of the exhaust nozzle. However, if the radius of curvature is small, the jet turns through a smaller angle, or may not attach to the surface at all. In general, the limitations in size and weight of a device will limit the radius of the deflection surface. Thus much effort has been paid to improve the jet deflection in a variety of engineering fields. The Coanda effect has long been applied to improve aerodynamic characteristics, such as the drag/lift ratio of flight body, the engine exhaust plume thrust vectoring, and the aerofoil/wing circulation control. During the energy crisis of the seventies, the Coanda jet was applied to reduce vehicle drag and led to drag reductions of as much as about 30% for a trailer configuration. Recently a variety of industrial applications are exploiting another characteristics of the Coanda jets, mainly the enhanced turbulence levels and entrainment compared with conventional jet flows. Various industrial burners and combustors are based upon this principle. If the curvature of the Coanda surface is too great or the operating pressure too high, the jet flow will break away completely from the surface. This could have catastrophic consequences for a burner or combustor. Detailed understanding of the Coanda jet flow is essential to refine the design to maximize the enhanced entrainment in these applications.

  • PDF

A Study on the Usefulness of Auto Dispenser and Optimized Dispensing Method (방사성 의약품 자동 분주장치의 유용성 및 최적화된 분주방법에 관한 고찰)

  • Lee, JeoungEun;Kim, Hosung;Ryu, Jaekwang;Jung, Wooyoung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.59-66
    • /
    • 2013
  • Purpose: Recently, there is an increase of the number of hospitals using auto dispenser to reduce occupational radiation exposure when drawing up of the $^{18}F-FDG$ dose (5.18 MBq/kg) in a syringe from the dramatic high activity of $^{18}F-FDG$ multidose vial. The aim of this study is to confirm that using auto dispenser actually reduces the radiation exposure for technologists. Also we analyzed the reproducibility of auto dispenser to find optimized dispensing method for the device. Materials and Methods: We conducted three experiments. Comparison of radiation exposure on chest and hands: The chest and hands exposure dose received by technologists during the injection were measured by electronic personal dosimeter (EPD) and ring TLD respectively. Reproducibility of dispensed volume: We draw up the normal saline into 5 and 2 mL syringe using auto dispenser by changing the volume from 1 to 15 mm for 5 times in the same setting of the volume. The weight of 5 normal saline dispensed from the device at same volume was measured using micro balance and calculated standard deviation and coefficient of variation. Reproducibility of dispensed radioactivity: We dispensed 362.6 $MBq{\pm}10%$ of $^{18}F-FDG$ in 5 and 2 mL syringes from the multidose vial of different specific activity. In the same setting of volume, we repeated dispensing for 4 times and compared standard deviation and coefficient of variation of radioactivity between 5 syringes. Results: There was significant difference in the average of chest exposure dose according to the dispensing methods (P<0.05). Also, when dispensing $^{18}F-FDG$ in manual method, exposure dose was 11.5 times higher in right hand and 4.8 times higher in left hand than in auto method. In the result of reproducibility of dispensed volume, standard deviation and coefficient of variation shows decline as the dispensing volume increases. As a result of reproducibility of dispensed radioactivity, standard deviation and coefficient of variation increases as the specific activity increases. Conclusion: We approved that the occupational radiation exposure dose of technologists were reduced when dispensing $^{18}F-FDG$ using auto dose dispenser. Secondly, using small syringes helps to increase reproducibility of auto dose dispense. And also, if you lower the specific activity of $^{18}F-FDG$ in multidose vial below 915-1,020 MBq/mL, you can use auto dispenser more effectively keeping the coefficient of variation lower than 10%.

  • PDF

Thermophysiological Responses of Wearing Safety Hat for Working at a Hot Environment (서열환경하에서 안전모 착용시의 인체생리학적 반응)

  • 박소진;김희은
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.1
    • /
    • pp.74-82
    • /
    • 2002
  • The present study is aimed to investigate the effect of the safety hat on the balance of body temperature by observation of the physiological response under hot working environment. The experiment was carried out in a climate chamber of 3$0^{\circ}C$, 50%RH for 70 minutes. To compare the two kinds of safety hat, 5 healthy male subjects worn safety hat without hole (called 'without hole') or safety hat with hole (called 'with hole') according to a randomized cross-over design. The main results of this study are as fellows: Rectal temperature and heart rate were significantly lower level in 'with hole'than in 'without hole'. The mean skin temperature was significantly higher in 'without hole'than in 'with hole'. Blood pressure were significantly low in 'with hole'. Sweat rate which was measured by weight loss before and after experiment was higher in 'without hole'. In subjective ratings, subjects replied more hot, more uncomfortable and more wet, they felt more fatigue in condition of 'without hole'. Work ability which was measured by a grip strength dynamometer was higher in 'with hole'. Safety hat which can be used for safety of the brain in work place is meaningful device of behavioral thermoregulatory response under the hot working environment. The safety hat which is designed for proper ventilation and hygiene can maintain the homeostasis of body temperature by releasing body temperature efficiently.