• Title/Summary/Keyword: Backup System

Search Result 314, Processing Time 0.034 seconds

Effective Index and Backup Techniques for HLR System in Mobile Networks (이동통신 HLR 시스템에서의 효과적인 색인 및 백업 기법)

  • 김장환;이충세
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.9 no.1
    • /
    • pp.33-46
    • /
    • 2003
  • A Home Location Register(HLR) database system manages each subscriber's location information, which continuously changes in a cellular network. For this purpose, the HLR database system provides table management, index management, and backup management facilities. In this thesis, we propose using a two-level index method for the mobile directory number(MDN) as a suitable method and a chained bucket hashing method for the electronic serial number(ESN). Both the MDN and the ESN are used as keys in the HLR database system. We also propose an efficient backup method that takes into account the characteristics of HLR database transactions. The retrieval speed and the memory usage of the two-level index method are better than those of the R-tree index method. The insertion and deletion overhead of the chained bucket hashing method is less than that of the modified linear hashing method. In the proposed backup method, we use two kinds of dirty flags in order to solve the performance degradation problem caused by frequent registration-location operations. For a million subscribers, proposed techniques support reduction of memory size(more than 62%), directory operations (2500,000 times), and backup operations(more than 80%) compared with current techniques.

Consistency and Prformance Evaluation of Duplication Function for Backup Systems (백업시스템을 위한 복제기능의 정합성과 성능평가)

  • Seong, HaeKyung;Lee, Moongoo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.147-153
    • /
    • 2012
  • As IT circumstance is complicated and the scale of infra increase, a recognition of security information system and data availability are raised. At this point, a value of information assets regards important, a study of high performance backup system for disaster recovery countermeasure is a field to impact on business directly. Therefore, this study executes duplication of high performance backup system and data consistency verification. And, a performance of comparison to DB table recovery process, a transaction process speed of duplication according to network bandwidth, and performance evaluation were executed.

IBC-Based Entity Authentication Protocols for Federated Cloud Systems

  • Cao, Chenlei;Zhang, Ru;Zhang, Mengyi;Yang, Yixian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.5
    • /
    • pp.1291-1312
    • /
    • 2013
  • Cloud computing changes the service models of information systems and accelerates the pace of technological innovation of consumer electronics. However, it also brings new security issues. As one of the important foundations of various cloud security solutions, entity authentication is attracting increasing interest of many researchers. This article proposes a layered security architecture to provide a trust transmission mechanism among cloud systems maintained by different organizations. Based on the security architecture, four protocols are proposed to implement mutual authentication, data sharing and secure data transmission in federated cloud systems. The protocols not only can ensure the confidentiality of the data transferred, but also resist man-in-the-middle attacks and masquerading attacks. Additionally, the security properties of the four protocols have been proved by S-pi calculus formal verification. Finally, the performance of the protocols is investigated in a lab environment and the feasibility of the security architecture has been verified under a hybrid cloud system.

Real-time Environmental Radiation Monitoring System with Automatic Restoration of Backup Data in Site Detector via Communication using Radio Frequency (현장검출기에 저장된 백업데이터를 무선통신방식으로 자동 복원하는 실시간 환경선량 감시 시스템)

  • Lee, Wan-No;Kim, Eun-Han;Chung, Kun-Ho;Cho, Young-Hyun;Choi, Geun-Sik;Lee, Chang-Woo;Park, Ki-Hyun;Kim, Yun-Goo
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.255-261
    • /
    • 2003
  • An environmental radiation monitoring system based on high pressurized ionization chamber has been used for on-line gamma monitoring surrounding the KAERI (Korea Atomic Energy Research Institute), which transmits the dose data measured from ion chamber on the site via radio frequency to a central processing computer and stores the transmitted real-time data. Although communication using radio frequency has several advantages such as effective and economical transmission, storage, and data process, there is one main disadvantage that data loss during transmission often happens because of unexpected communication problems. It is possible to restore the loss data by off-line such as floppy disk but the simultaneous process and display of current data as well as the backup data are very difficult in the present on-line system. In this work, a new electronic circuit board and the operation software applicable to the conventional environmental radiation monitoring system are developed and the automatical synchronization of the ion chamber unit and the central processing computer is carried out every day. This system is automatically able to restore the backup data within 34 hours without additional equipments and also display together the current data as well as the transmitted backup data after checking time flag.

A Web-Based Data Backup Method (웹 기반의 데이터 백업 방안)

  • Lee Bong-Seob;Han Kun-Hee;Choi Shin-Hyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.6
    • /
    • pp.486-490
    • /
    • 2005
  • The web is used widely and the users of the majority are depending to get the information on web, the necessity of the data management by web is increasing. The sudden system failure frequently occurs from network environment, we must protect data from this danger. In this paper, we present web based data management method, which is composed of two type backup and restoration. This method support data management through web browser and provides systematic, efficient and stable data management on web.

  • PDF

Fault Tolerant of IED in IEC61850 based Substation Automation System (IEC 61850기반 변전소 자동화 시스템에서 IED의 결함 극복 방법)

  • Lee, Dong-Wook;Jin, Yong-Woo;Lee, Duck-Su;Lim, Seong-Il;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.152-154
    • /
    • 2005
  • This paper proposes new methods which are used for trouble detecting and tolerance of IED in IEC61850 based Substation Automation System. There are three point devices for construction of this system: Trouble Detection IED, Backup IED and Engineering Unit. Trouble Detection IED tests trouble of Bay IED and sends the result to Engineering Unit. And then Engineering Unit is able to control the system. When fault occurs in Bay IED, Backup IED will be substitute the troubled Bay IED. If this proposed scheme can be used in this system, the reliability of the Power System would be greatly improved.

  • PDF

A Study of Active Hardware Redundancy Module Management for Brake-by-wire using In-vehicle-network (차량용 네트워크를 이용한 Brake-by-wire 시스템의 Active hardware redundancy 모듈 운영에 관한 연구)

  • Yoon, Jong-Woon;Kim, Ki-Eung;Kim, Tae-Yeol;Kim, Jae-Gu;Lee, Seok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.111-111
    • /
    • 2000
  • The research of network system, being used to reduce automotive wiring harness, is reaching to the development of by-wire system. It is by-wire system that apply IVN(In-Vehicle-Network) to steering, braking system, and it has the advantage of mass-decreasing, easy to diagnose fault and so on. But until now, many developed device can't satisfied with reliability that system have ever had. So redundancy of each network module, i.e., It is only way to make backup module. This paper researches development of network module and redundancy management of backup module when error occurred for implementation of brake-by-wire system.

  • PDF

Optimal Savepoint in a Loosely-Coupled Resilient Database System (느슨히 결합된 데이타베이스 시스템에서 최적의 저장점 유도)

  • Choe, Jae-Hwa;Kim, Seong-Eon
    • Asia pacific journal of information systems
    • /
    • v.6 no.1
    • /
    • pp.21-38
    • /
    • 1996
  • This paper investigates the performance improvement opportunities through a resiliency mechanism in the distributed primary/backup database system. Recognizing that a distributed transaction executes at several servers during its lifetime, we propose a resiliency mechanism which allows continuous transaction processing in distributed database server systems in the presence of a server failure. In order to perform continuous transaction processing despite failures, every state change of a transaction processing can be saved in the backup server. Obviously, this pessimistic synchronization may give more burdens than benefits to the system. Thus, the tracking needs not be done synchronously with the transaction progress. Instead, the state of all transaction processing in a system is saved periodically. This activity is referred to as a savepoint. Then, the question is how often the savepoint has to be done. We derive the optimal savepoint to identify the optimization parameters for the resilient transaction processing system.

  • PDF

Safety Review Experience of Computerized Logic System for YGN 3 and 4

  • Yun, Won-Young;Kim, Dae-Il;Koh, Jong-Soo;Kim, Bok-Ryul;Oh, Sung-Hun;Lim, Jang-Hyun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.602-607
    • /
    • 1995
  • This article presents safety review experience of microprocessor-based Interposing Logic System(ILS) of Engineering Safety Feature Actuation System(ESFAS). The ILS is the first application of computerized logic design to safety system in Korean nuclear power plants without verification of the system reliability by proven technology concept. As a result of evaluation for the ILS, Korea Institute of Nuclear Safety(KINS) concluded that the microprocessor-based ILS is not acceptable in some features detailed enough to defend against software common mode failures(CMF). Therefore, we required licensee to install hardwired interlock signal configuration and a Hardwired Backup Panel to control safety-related equipment. We believe that the microprocessor-based ILS with the hardwired backup panel and inter-connection of interlock signal by hardwired configuration will improve the plant safety.

  • PDF

A Study for Detection of the Kernel Backdoor Attack and Design of the restoration system (커널 백도어 공격 탐지 및 복구시스템 설계에 관한 연구)

  • Jeon, Wan-Keun;Oh, Im-Geol
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.12 no.3
    • /
    • pp.104-115
    • /
    • 2007
  • As soon as an intrusion is detected by kernel backdoor, the proposed method can be preserve secure and trustworthy evidence even in a damaged system. As an experimental tool, we implement a backup and analysis system, which can be response quickly, to minimize the damages. In this paper, we propose a method, which can restore the deleted log file and analyze the image of a hard disk, to be able to expose the location of a intruder.

  • PDF