• Title/Summary/Keyword: Background subtraction

Search Result 236, Processing Time 0.025 seconds

A Brazing Defect Detection Using an Ultrasonic Infrared Imaging Inspection (초음파 열 영상 검사를 이용한 브레이징 접합 결함 검출)

  • Cho, Jai-Wan;Choi, Young-Soo;Jung, Seung-Ho;Jung, Hyun-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.426-431
    • /
    • 2007
  • When a high-energy ultrasound propagates through a solid body that contains a crack or a delamination, the two faces of the defect do not ordinarily vibrate in unison, and dissipative phenomena such as friction, rubbing and clapping between the faces will convert some of the vibrational energy to heat. By combining this heating effect with infrared imaging, one can detect a subsurface defect in material in real time. In this paper a realtime detection of the brazing defect of thin Inconel plates using the UIR (ultrasonic infrared imaging) technology is described. A low frequency (23 kHz) ultrasonic transducer was used to infuse the welded Inconel plates with a short pulse of sound for 280 ms. The ultrasonic source has a maximum power of 2 kW. The surface temperature of the area under inspection is imaged by an infrared camera that is coupled to a fast frame grabber in a computer. The hot spots, which are a small area around the bound between the two faces of the Inconel plates near the defective brazing point and heated up highly, are observed. And the weak thermal signal is observed at the defect position of brazed plate also. Using the image processing technology such as background subtraction average and image enhancement using histogram equalization, the position of defective brazing regions in the thin Inconel plates can be located certainly.

Vehicle License Plate Detection Based on Mathematical Morphology and Symmetry (수리 형태론과 대칭성을 이용한 자동차 번호판 검출)

  • Kim, Jin-Heon;Moon, Je-Hyung;Choi, Tae-Young
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.2
    • /
    • pp.40-47
    • /
    • 2009
  • This paper proposes a method for vehicle license plate detection using mathematical morphology and symmetry. In general, the shape, color, size, and position of license plate are regulated by authorities for a better recognition by human. Among them, the relatively big intensity difference between the letter and the background region of the license plate and the symmetry about the plate are major discriminating factors for the detection. For the first, the opened image is subtracted from the closed image to intensify the region of plate using the rectangular structuring element which has the width of the distance between two characters. Second the subtraction image is average filtered with the mask size of the plate. Third, the column maximum graph of the average filtered image is acquired and the symmetry of the graph is measured at every position. Fourth, the peaks of the average filtered image are searched. Finally, the plate is assumed to be positioned around the one of local maxima nearest to the point of the highest symmetry. About 1,000 images taken by speed regulation camera are used for the experiment. The experimental result shows that the plate detection rate is about 93%.

A clinical study of Soyangin Yangkyuksanwhatang (양격산화탕(凉膈散火湯) 활용(活用)에 대(對)한 임상적(臨床的) 연구(硏究))

  • Park, Seong-sik;Kim, Ji-yong;Choi, Jae-young
    • Journal of Sasang Constitutional Medicine
    • /
    • v.10 no.2
    • /
    • pp.455-471
    • /
    • 1998
  • Background and Purpose : We intended to be helpful to understand constitutional symptoms of a disease and an application of the prescription through a clinical study of Soyangin Yangkyuksanwhatang. Methods : We studied 65 patients(40 men and 25 women) treated with Soyangin Yangkyuksanwhatang in constitutional clinic of Dongguk Pundang Oriental Hospital. And then we investigated the characteristics of Yangkyuksanwhatang treated patients, remedial values, onset of action and side effects. Results: Soyangin Yangkyuksanwhatang was used in all age groups both men and women. There were 37 kinds of chief complaints including chest discomfort, numbness of hands and feet, motor disturbance and skin disease etc. The distributions of remedial values were slightly improved(58.5%), much improved(12.3%), no improved(29.3%) and there was no aggravated patient. Using the prescription, mostly I prescribed only Soyangin Yangkyuksanwhatang without any changing, and added some herbs to the prescription according to the symptoms of a disease. Soyangin Yangkyuksanwhatang was affected in remedial values by the addition and subtraction of herbs. The onset of action in young age group was shorter than old age group. Side effects were palpitation, abdominal pain and indigestion etc.

  • PDF

A Study on Orchestration in "Battle for The Glory" out of the Background Music in the Animation "Dragon Quest IV" (애니메이션 "드래곤 퀘스트 IV"의 배경음악 중 "Battle for The Glory"에 나타난 관현악법 연구)

  • Jung, Kil
    • Cartoon and Animation Studies
    • /
    • s.39
    • /
    • pp.321-348
    • /
    • 2015
  • The purpose of this study was to find a system and a progression principle in orchestral piece based on the outcome after comparatively analyzing the orchestral operation technique in "Battle for The Glory" out of the background music in the animation "Dragon Quest IV" by Koichi Sugiyama(1931~), who is a leading runner of Japan's animation music, based on functional parts daccord & Instrumentation Pattern, Rhythm Pattern, Voicing Pattern, and harmonic ratio by progression section devised by the writer. As a result, first, five themes in this music have specific instrumentation pattern, respectively. In a passage that is shown exposition, reprise, and representation in theme, the unity was emphasized by maintaining the same instrumentation pattern. On the contrary to this, a passage of being suggested new theme is being used the exchange method and addition & subtraction in musical instrument in order to strengthen diversity. Second, the voicing pattern is forming the vertical contrasting relationship of "thinness-thickness" on the whole. However, the diversity is being intensified that is changed into the structure of "thickness-thinness" in the third theme and of "thinness-thickness" that has two melodies in the fourth theme. Third, the rhythm pattern is forming the vertical contrasting relationship of "big-small" on the whole. However, the fifth theme is being given diversity with being changed into the structure of "small-big." Fourth, the harmony by progression section from the horizontal perspective is shown to be high in the proportion of unity in the section of being repeated and represented the theme and to be high in the proportion of diversity in the section of being suggested new theme. In this study, the balanced orchestral operation technique through the operation technique, which was used in this work, is what extracts the relationship of diverse proportions in the horizontal progression section based on the technique of vertical perspective. In this aspect, this analytical study is desired to be positioned as a new paradigm in establishing a theoretical system and an educational method in orchestration.

Role of the Inferior Thyroid Vein after Left Brachiocephalic Vein Division During Aortic Surgery

  • Park, Hyung-Ho;Kim, Bo-Young;Oh, Bong-Suk;Yang, Ki-Wan;Seo, Hong-Joo;Lim, Young-Hyuk;Kim, Jeong-Jung
    • Journal of Chest Surgery
    • /
    • v.35 no.7
    • /
    • pp.530-534
    • /
    • 2002
  • Background: In aortic surgery, division and ligation of the left brachiocephalic vein(LBV) may improve exposure of the aortic arch but controversy continues about the safety of this division and whether a divided vein should be reanastomosed after arch replacement was completed. The safety of LBV division and the fate of the left subclavian venous drainage after LBV division were studied. Material and Method: From November 1998 to January 2001, planned division and ligation of the LBV on the mid-line after median sternotomy was peformed in 10 patients during the aortic surgery with the consideration of local anatomy and distal aortic anastomosis. Assessment for upper extremity edema and neurologic symptoms, measurement of venous pressure in the right atrium and left internal jugular vein, and digital subtraction venography(DSV) of the left arm were made postoperatively. Result: In 10 patients there was improvement in access to the aortic arch for procedures on the ascending aorta or aortic arch. The mean age of patients was 62 years(range 24 to 70). Follow-up ranged from 3 weeks to 13 months. One patient died because of mediastinitis from methicilline-resistant staphylococcus aureus strain. All patients had edema on the left upper extremity, but resolved by the postoperative day 4. No patient had any residual edema or difficulty in using the left upper extremity during the entire follow-up period. No patient had postoperative stroke. Pressure difference between the right atrium and left internal jugular vein was peaked on the immediate postoperative period(mean peak pressure difference = 25mmHg), but gradually decreased, then plated by the postoperative day 4. In all DSV studies left subclavian vein flowed across the midline through the inferior thyroid venous plexus. Conclusion: We conclude that division of LBV is safe and reanastomosis is not necessary if inferior thyroid vein, which is developed as a main bridge connecting the left subclavian vein with right venous system, is preserved.

$^{99m}Tc-MAG_3$ Elimination Index on Normal Functioning Transplanted Kidney ($^{99m}Tc-MAG_3$ 제거지수를 이용한 이식신장의 기능평가)

  • Jeon, Woo-Jin;Kim, Ju-Heon;Park, Mi-Ok;Lee, Hee-Jung;Hyun, Jung-Ae;Zeon, Seok-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.79-83
    • /
    • 1995
  • Purpose : We analysed $^{99m}Tc-MAG_3$ renal scans to evaluate renal function of transplanted kidney and to detect various renal transplant complications, measuring the ratio of renal radioactivity at three minutes to that at 20 minutes(elimination index). Material and Methods : The fifty seven renal transplantation recipients were studied. There were 50 normal functioning transplanted kidneys as group I and 7 abnormal function-ing transplanted kidney, including 5 cases of acute renal rejection, 2 cases of acute tubular necrosis as group IIl. The protocol consisted of: (1) $^{99m}Tc-MAG_3$ 740MBq injection intravenously : (2) sequential imaging for 2min(60two-second images) followed by 30min(30 sixty-second images) : (3) drawing of region of interest(ROI) on renal imaging; (4) time-activity corves were generated from renal ROI after background subtraction, and time of maximum activity($T_{max}$) and half time of maximal peak radioactivity($T_{1/2}$) were produced in the renogram curve. (5) EI through Bischof-Delaloye method as determined on the renogram curve. Results : Normal group( I ) shows mean EI of 2.21(95.0% Confidence limit of 2.01-2.87), $T_{max}$ of 154 sec, $T_{1/2}$ of 1,139 sec. Abnormal group(II) shows mean EI of 0.74, $T_{max}$ of 1,466 sec, $T_{1/2}$ of 19,224 sec. The EI, $T_{max}$, $T_{1/2}$, BUN and serum creatinine values are significantly different between normal group(I) and abnormal group(II) (p<0.0001). Conclusion : By measuring EI with $^{99m}Tc-MAG_3$, renal function of transplanted kidney could be easily evaluated and various complications could be detected early.

  • PDF