• Title/Summary/Keyword: Background removal

Search Result 458, Processing Time 0.024 seconds

Robot-Assisted Cardiac Surgery Using the Da Vinci Surgical System: A Single Center Experience

  • Kim, Eung Re;Lim, Cheong;Kim, Dong Jin;Kim, Jun Sung;Park, Kay Hyun
    • Journal of Chest Surgery
    • /
    • v.48 no.2
    • /
    • pp.99-104
    • /
    • 2015
  • Background: We report our initial experiences of robot-assisted cardiac surgery using the da Vinci Surgical System. Methods: Between February 2010 and March 2014, 50 consecutive patients underwent minimally invasive robot-assisted cardiac surgery. Results: Robot-assisted cardiac surgery was employed in two cases of minimally invasive direct coronary artery bypass, 17 cases of mitral valve repair, 10 cases of cardiac myxoma removal, 20 cases of atrial septal defect repair, and one isolated CryoMaze procedure. Average cardiopulmonary bypass time and average aorta cross-clamping time were $194.8{\pm}48.6$ minutes and $126.1{\pm}22.6$ minutes in mitral valve repair operations and $132.0{\pm}32.0$ minutes and $76.1{\pm}23.1$ minutes in myxoma removal operations, respectively. During atrial septal defect closure operations, the average cardiopulmonary bypass time was $128.3{\pm}43.1$ minutes. The median length of stay was between five and seven days. The only complication was that one patient needed reoperation to address bleeding. There were no hospital mortalities. Conclusion: Robot-assisted cardiac surgery is safe and effective for mitral valve repair, atrial septal defect closure, and cardiac myxoma removal surgery. Reducing operative time depends heavily on the experience of the entire robotic surgical team.

A Framework for Object Detection by Haze Removal (안개 제거에 의한 객체 검출 성능 향상 방법)

  • Kim, Sang-Kyoon;Choi, Kyoung-Ho;Park, Soon-Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.5
    • /
    • pp.168-176
    • /
    • 2014
  • Detecting moving objects from a video sequence is a fundamental and critical task in video surveillance, traffic monitoring and analysis, and human detection and tracking. It is very difficult to detect moving objects in a video sequence degraded by the environmental factor such as fog. In particular, the color of an object become similar to the neighbor and it reduces the saturation, thus making it very difficult to distinguish the object from the background. For such a reason, it is shown that the performance and reliability of object detection and tracking are poor in the foggy weather. In this paper, we propose a novel method to improve the performance of object detection, combining a haze removal algorithm and a local histogram-based object tracking method. For the quantitative evaluation of the proposed system, information retrieval measurements, recall and precision, are used to quantify how well the performance is improved before and after the haze removal. As a result, the visibility of the image is enhanced and the performance of objects detection is improved.

Safe and Simplified Salvage Technique for Exposed Implantable Cardiac Electronic Devices under Local Anesthesia

  • Jung, Chang Young;Kim, Tae Gon;Kim, Sung-Eun;Chung, Kyu-Jin;Lee, Jun Ho;Kim, Yong-Ha
    • Archives of Plastic Surgery
    • /
    • v.44 no.1
    • /
    • pp.42-47
    • /
    • 2017
  • Background Skin erosion is a dire complication of implantable cardiac pacemakers and defibrillators. Classical treatments involve removal of the entire generator and lead systems, however, these may result in fatal complications. In this study, we present our experience with a simplified salvage technique for exposed implantable cardiac electronic devices (ICEDs) without removing the implanted device, in an attempt to reduce the risks and complication rates associated with this condition. Methods The records of 10 patients who experienced direct ICED exposure between January 2012 and December 2015 were retrospectively reviewed. The following surgical procedure was performed in all patients: removal of skin erosion and capsule, creation of a new pocket at least 1.0-1.5 cm inferior to its original position, migration of the ICED to the new pocket, and insertion of closed-suction drainage. Patients with gross local sepsis or septicemia were excluded from this study. Results Seven patients had cardiac pacemakers and the other 3 had implantable cardiac defibrillators. The time from primary ICED placement to exposure ranged from 0.3 to 151 months (mean, 29 months. Postoperative follow-up in this series ranged from 8 to 31 months (mean follow-up, 22 months). Among the 10 patients, none presented with any signs of overt infection or cutaneous lesions, except 1 patient with hematoma on postoperative day 5. The hematoma was successfully treated by surgical removal and repositioning of the closed-suction drainage. Conclusions Based on our experience, salvage of exposed ICEDs is possible without removing the device in selected patients.

Reconstruction of Large Facial Defects via Excision of Skin Cancer Using Two or More Regional Flaps

  • Lee, Dong Min;Bae, Yong Chan;Nam, Su Bong;Bae, Seong Hwan;Choi, June Seok
    • Archives of Plastic Surgery
    • /
    • v.44 no.4
    • /
    • pp.319-323
    • /
    • 2017
  • Background Free-flap surgery and skin grafting can be used to reconstruct large facial defects that may result after skin cancer removal by Mohs micrographic surgery (MMS). However, these two methods may produce low postsurgical patient satisfaction with aesthetics, and free-flap surgery may produce an undue burden for the majority of skin cancer patients, who are of advanced age. Hence, the authors examined outcomes of large facial defect reconstruction using multiple flaps. Methods Among patients undergoing MMS for skin cancer at Pusan National University Hospital between January 2013 and December 2015, we evaluated 7 patients (2 males, 5 females; average age, 73.14 years) treated for large facial defects from basal cell carcinoma. Based on operative and follow-up records, we investigated the number and type of flaps used, postsurgical complications, and patients' post-surgical satisfaction. Results Two and 3 types of flaps were used for 5 and 2 patients, respectively. Most frequently used were nasolabial flaps (7 times in 6 patients) and forehead flaps (once in each of 4 patients). The average follow-up period was 14 months, with no complications-including necrosis, hematoma, or wound dehiscence-observed. Post-surgical satisfaction averaged 4.4 out of a maximum of 5 points. Conclusions Reconstruction using two or more flaps for large facial defects after skin cancer removal using MMS produced satisfactory outcomes while preventing aesthetic problems. Practitioners should consider using multiple flaps when choosing a reconstruction method for large facial defects following skin cancer removal.

Muscle-Sparing Blepharoplasty: A Prospective Left-Right Comparative Study

  • Kiang, Lee;Deptula, Peter;Mazhar, Momal;Murariu, Daniel;Parsa, Fereydoun Don
    • Archives of Plastic Surgery
    • /
    • v.41 no.5
    • /
    • pp.576-583
    • /
    • 2014
  • Background Standard upper blepharoplasty involves removal of both the skin and a portion of the underlying orbicularis oculi muscle. The senior author had observed sluggishness of eyelid closure, lagophthalmos as well as varying degrees of eye irritation in certain patients during the early postoperative period. He postulated that these findings could be due to orbicularis muscle excision. He therefore undertook a prospective study 27 years ago comparing standard blepharoplasty on one eyelid to skin-only excision on the fellow eyelid. Methods A randomized, prospective, single-blinded study was designed using the fellow eye as an internal control. 22 patients undergoing upper blepharoplasty procedure requiring greater than 5 mm of skin resection and with no history of ophthalmologic disease, dry eye, or previous eyelid surgery were selected. Upper blepharoplasty was performed with skin-only removal on one side, and combined skin-muscle removal on the other side. Patients were evaluated until six months after surgery except for two patients who were lost to follow-up after three months. Sluggish eyelid closure, lagophthalmos, dry eye and aesthetic result were outcome measures scored by patient survey, the operating surgeon, and a blinded expert panel. Results There were comparable aesthetic outcomes in both eyelids. The incidence of sluggish eyelid closure, lagophthalmos and dry eye syndrome were significantly higher in eyelids where wide segments of muscle had been resected. Conclusions Muscle-sparing upper blepharoplasty produces similar aesthetic outcomes as conventional blepharoplasty, while significantly reducing the complications of sluggish eyelid closure, lagophthalmos and dry eye disease. The authors therefore recommend muscle-sparing upper blepharoplasty.

THE EFFECT OF PRE-OPERATIVE STEROID INJECTION ON THE RELIEF OF COMPLAINT AFTER THIRD MOLAR SURGERY (술 전 스테로이드 투여가 하악 매복 제 3 대구치 발치 후 예상되는 불편감에 미치는 영향)

  • Kim, Sung-Dae;Kim, Kyung-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.3
    • /
    • pp.157-162
    • /
    • 2003
  • Background : The surgical removal of impacted mandibular third molar can result in considerable pain, swelling, and dysfunction that patient are incapable of work for several days. Factors contributing to post operative swelling, trismus and pain are complex. There is no question but that the procedure of surgically removing an impacted mandibular third molar is inherently a traumatic one and that some sequelae related to the inflammation response are expected. Meticulous surgical technique will minimize the sequelae of inflammation but will not prevent them. In an effort to minimize these sequelae the use of steroid was instituted. Patients and Methods : Present study was to investigate the effect of one preoperative steroid injection in the masseter muscle to the patients(male 9, female 11) who needed prophylactic removal of bilateral, symmetrical, impacted wisdom teeth in the mandible on the complaint like swelling, trismus and pain. through Double-Blind test. Results : 1. After 24 hours investigation, preoperative steroid injection had significantly reduced swelling with 39% and trismus with 57.5%. 2. $7^{th}$ post operative day investigation, reduced swelling and trismus had shown, however, not significant. 3. There wasn't major difference from the group who took preve-ntive steroid in the visual analogue scale, the first analgesic intake time and the pain period. 4. There wasn't any adverse reaction of steroid for 20 patient From the above result, If the patients are not contraindication to steroid and pronounced post operative reaction can be expected the use of steroid to the surgical removal of impacted mandibular third molar is recommended.

Development of a Fission Product Transport Module Predicting the Behavior of Radiological Materials during Severe Accidents in a Nuclear Power Plant

  • Kang, Hyung Seok;Rhee, Bo Wook;Kim, Dong Ha
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.237-244
    • /
    • 2016
  • Background: Korea Atomic Energy Research Institute is developing a fission product transport module for predicting the behavior of radioactive materials in the primary cooling system of a nuclear power plant as a separate module, which will be connected to a severe accident analysis code, Core Meltdown Progression Accident Simulation Software (COMPASS). Materials and Methods: This fission product transport (COMPASS-FP) module consists of a fission product release model, an aerosol generation model, and an aerosol transport model. In the fission product release model there are three submodels based on empirical correlations, and they are used to simulate the fission product gases release from the reactor core. In the aerosol generation model, the mass conservation law and Raoult's law are applied to the mixture of vapors and droplets of the fission products in a specified control volume to find the generation of the aerosol droplet. In the aerosol transport model, empirical correlations available from the open literature are used to simulate the aerosol removal processes owing to the gravitational settling, inertia impaction, diffusiophoresis, and thermophoresis. Results and Discussion: The COMPASS-FP module was validated against Aerosol Behavior Code Validation and Evaluation (ABCOVE-5) test performed by Hanford Engineering Development Laboratory for comparing the prediction and test data. The comparison results assuming a non-spherical aerosol shape for the suspended aerosol mass concentration showed a good agreement with an error range of about ${\pm}6%$. Conclusion: It was found that the COMPASS-FP module produced the reasonable results of the fission product gases release, the aerosol generation, and the gravitational settling in the aerosol removal processes for ABCOVE-5. However, more validation for other aerosol removal models needs to be performed.

The effect of early arm exercise on drainage volume after total mastectomy and tissue expander insertion in breast cancer patients: a prospective study

  • Joo, Oh Young;Moon, Seung Jin;Lee, Dong Won;Lew, Dae Hyun;Lee, Won Jai;Song, Seung Yong
    • Archives of Plastic Surgery
    • /
    • v.48 no.6
    • /
    • pp.583-589
    • /
    • 2021
  • Background In prosthesis-based breast reconstruction patients, the drain tends to be kept in place longer than in patients who undergo only mastectomy. Postoperative arm exercise also increases the drainage volume. However, to preserve shoulder function, early exercise is recommended. In this study, we investigated the effect of early exercise on the total drainage volume and drain duration in these patients. Methods We designed a prospective randomized trial involving 56 patients who underwent immediate breast reconstruction following mastectomy using tissue expanders. In each group, the patients were randomized either to perform early arm exercises using specific shoulder movement guidelines 2 days after surgery or to restrict arm movement above the shoulder height until drain removal. The drain duration and the total amount of drainage were the primary endpoints. Results There were no significant differences in age, height, weight, body mass index, or mastectomy specimen weight between the two groups. The total amount of drainage was 1,497 mL in the early exercise group and 1,336 mL in the exercise restriction group. The duration until complete removal of the drains was 19.71 days in the early exercise group and 17.11 days in the exercise restriction group. Conclusions Exercise restriction after breast reconstruction did not lead to a significant difference in the drainage volume or the average time until drain removal. Thus, early exercise is recommended for improved shoulder mobility postoperatively. More long-term studies are needed to determine the effect of early exercise on shoulder mobility in prosthesis-based breast reconstruction patients.

Comparison of the Effects of General and Pregnant Women's Dentifrices on the Removal of the Dental Plaque

  • Kim, Ye-Eun;Ko, Seong-Eun;Sa, Da-Eun;Lee, Ji-Eun;Jeon, Se-Yoon;Lim, Do-Seon
    • Journal of dental hygiene science
    • /
    • v.20 no.4
    • /
    • pp.245-251
    • /
    • 2020
  • Background: This study tries to compare and analyze the removal effect of dental plaque of general dentifrice and pregnant women's dentifrice and quantify the results to provide basic data so that consumers can make reasonable choices when purchasing dentifrice, and also increase interest in the dental plaque. Methods: After forming a dental plaque (carbohydrate porridge) on the labial surface of the bovine teeth, a disclosing agent was applied. Then the same experimenter brushed the surface of the bovine teeth using an electric toothbrush and took photographs using a DSLR camera. Thereafter, the residual amount of dental plaque was analyzed using the ImageJ program, and SPSS 26.0 was used for statistical processing. Results: The average residual amount of dental plaque using the general dentifrice was 11.71% for Perio, 9.45% for Cliden, and 8.47% for 2080, and the average residual amount for the three types was approximately 9.88%. The average residual amount of dental plaque of pregnant women's dentifrice was 13.95% for Jeninmothers, 12.53% for Tntnmoms, and 12.63% for Mommiracle, and the average residual amount of the three types was approximately 13.04%. On comparing the average residual amount of dental plaque between general and pregnant women's dentifrices, it was observed to be 3.16% higher for the latter. However, the results were not statistically significant. Conclusion: According to the research results, there was no significant difference in removal effects of general dentifrice and pregnant women's dentifrice. In addition, when a pregnant woman uses the right toothbrushing method with pregnant women's dentifrice, it can prevent or inhibit the progression of the gestational periodontal disease. Therefore, we recommend pregnant women to use pregnant women's dentifrices.

Comparative efficacy of bromelain and aceclofenac in limiting post-operative inflammatory sequelae in surgical removal of lower impacted third molar: a randomized controlled, triple blind clinical trial

  • Gupta, Aishwarya Ashok;Kambala, Rajanikanth;Bhola, Nitin;Jadhav, Anendd
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.1
    • /
    • pp.29-37
    • /
    • 2022
  • Background: Pain, edema, and trismus are predictable sequelae for surgical extraction of impacted mandibular third molars (M3M). The present study aimed to compare the anti-phlogistic potential of bromelain and aceclofenac in the reduction of post-surgical sequalae in the extraction of impacted M3M. Method: A randomized controlled, triple-blinded clinical study included 72 patients scheduled for surgical removal of impacted M3M under local anesthesia. Randomization was performed and subjects were equally allocated to groups A (control) and B (study), who intended to receive aceclofenac and bromelain, respectively. The primary outcome variables were pain, edema, and trismus evaluated on postoperative days 2 and 7 and compared with baseline values. The secondary variables evaluated were the quantity of rescue analgesics required and the frequency of adverse effects in both groups for 7 postoperative (PO) days. Data were analyzed with a level of significance of P < 0.05. Results: Group B demonstrated a significant decrease in the severity of edema and trismus compared to group A on both PO days 2 and 7 (P < 0.001). Bromelain demonstrated similar analgesic efficacy with an insignificant difference compared to aceclofenac (P > 0.05). Conclusion: The present study showed that the efficacy of bromelain was comparable to that of aceclofenac in reducing inflammatory complications following surgical removal of impacted M3M. Bromelain can be considered a safe and potent alternative to routinely used aceclofenac when addressing inflammatory outcomes after surgery.