• Title/Summary/Keyword: Background fracture

Search Result 321, Processing Time 0.027 seconds

Biomechanical investigation of arm position on deforming muscular forces in proximal humerus fractures

  • Christen E. Chalmers;David J. Wright;Nilay A. Patel;Hunter Hitchens;Michelle McGarry;Thay Q. Lee;John A. Scolaro
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.4
    • /
    • pp.282-287
    • /
    • 2022
  • Background: Muscular forces drive proximal humeral fracture deformity, yet it is unknown if arm position can help mitigate such forces. Our hypothesis was that glenohumeral abduction and humeral internal rotation decrease the pull of the supraspinatus and subscapularis muscles, minimizing varus fracture deformity. Methods: A medial wedge osteotomy was performed in eight cadaveric shoulders to simulate a two-part fracture. The specimens were tested on a custom shoulder testing system. Humeral head varus was measured following physiologic muscle loading at neutral and 20° humeral internal rotation at both 0° and 20° glenohumeral abduction. Results: There was a significant decrease in varus deformity caused by the subscapularis (p<0.05) at 20° abduction. Significantly increasing humeral internal rotation decreased varus deformity caused by the subscapularis (p<0.05) at both abduction angles and that caused by the supraspinatus (p<0.05) and infraspinatus (p<0.05) at 0° abduction only. Conclusions: Postoperative shoulder abduction and internal rotation can be protective against varus failure following proximal humeral fracture fixation as these positions decrease tension on the supraspinatus and subscapularis muscles. Use of a resting sling that places the shoulder in this position should be considered.

Automatic Fracture Detection in CT Scan Images of Rocks Using Modified Faster R-CNN Deep-Learning Algorithm with Rotated Bounding Box (회전 경계박스 기능의 변형 FASTER R-CNN 딥러닝 알고리즘을 이용한 암석 CT 영상 내 자동 균열 탐지)

  • Pham, Chuyen;Zhuang, Li;Yeom, Sun;Shin, Hyu-Soung
    • Tunnel and Underground Space
    • /
    • v.31 no.5
    • /
    • pp.374-384
    • /
    • 2021
  • In this study, we propose a new approach for automatic fracture detection in CT scan images of rock specimens. This approach is built on top of two-stage object detection deep learning algorithm called Faster R-CNN with a major modification of using rotated bounding box. The use of rotated bounding box plays a key role in the future work to overcome several inherent difficulties of fracture segmentation relating to the heterogeneity of uninterested background (i.e., minerals) and the variation in size and shape of fracture. Comparing to the commonly used bounding box (i.e., axis-align bounding box), rotated bounding box shows a greater adaptability to fit with the elongated shape of fracture, such that minimizing the ratio of background within the bounding box. Besides, an additional benefit of rotated bounding box is that it can provide relative information on the orientation and length of fracture without the further segmentation and measurement step. To validate the applicability of the proposed approach, we train and test our approach with a number of CT image sets of fractured granite specimens with highly heterogeneous background and other rocks such as sandstone and shale. The result demonstrates that our approach can lead to the encouraging results on fracture detection with the mean average precision (mAP) up to 0.89 and also outperform the conventional approach in terms of background-to-object ratio within the bounding box.

Reduction of Nasal Bone Fracture using Ultrasound Imaging during Surgery

  • Hwang, So-Min;Pan, Hao-Ching;Kim, Hong-Il;Kim, Hyung-Do;Hwang, Min-Kyu;Kim, Min-Wook;Lee, Jong-Seo
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.1
    • /
    • pp.14-19
    • /
    • 2016
  • Background: Most nasal bone fractures are corrected using non-invasive methods. Often, patients are dissatisfied with surgical outcomes following such closed approach. In this study, we compare surgical outcomes following blind closed reduction to that of ultrasound-guided reduction. Methods: A single-institutional prospective study was performed for all nasal fracture patients (n=28) presenting between May 2013 and November 2013. Upon research consent, patients were randomly assigned to either the control group (n=14, blind reduction) or the experimental group (n=14, ultrasound-guided reduction). Surgical outcomes were evaluated using preoperative and 3-month postoperative X-ray images by two independent surgeons. Patient satisfaction was evaluated using a questionnaire survey. Results: The experimental group consisted of 4 patients with Plane I fracture and 10 patients with Plane II fracture. The control group consisted of 3 patients with Plane I fracture and 11 patients with Plane II fracture. The mean surgical outcomes score and the mean patient dissatisfaction score were found not to differ between the experimental and the control group in Plane I fracture (p=0.755, 0.578, respectively). In a subgroup analysis consisting of Plane II fractures only, surgeons graded outcomes for ultrasound-guided reduction higher than that for the control group (p=0.007). Likewise, among the Plane II fracture patients, those who underwent ultrasound-guided reduction were less dissatisfied than those who underwent blind reduction (p=0.043). Conclusion: Our study result suggests that ultrasound-guided closed reduction is superior to blind closed reduction in those patients with Plane II nasal fractures.

Usefulness of Indirect Open Reduction and External Fixation in Algorithm Oriented Treatment of Nasal Fracture (비골골절 치료 시 간접 관혈적 정복술 및 외고정술의 유용성)

  • Park, Ki Rin;Chung, Kyu-Jin;Kim, Yong-Ha
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.2
    • /
    • pp.81-88
    • /
    • 2013
  • Background: To suggest the need of more aggressive reduction techniques than closed reduction (CR) technique in nasal fracture treatment, we identified the usefulness of algorithm oriented treatment of nasal fracture that includes indirect open reduction (IOR) and external fixation (EF) as well as the CR. Methods: We compared the clinical course of the group A (n=128) where only the CR was performed regardless of the pattern of the nasal fracture and the group B (n=127) where algorithm oriented treatment including IOR and EF as well as CR was performed depending on the pattern of nasal fracture. And the degree of postoperative pain after CR and IOR technique was compared through the dose of analgesics and pain scores. Results: More than 80% of patients were satisfied the result of reduction in both group A and B. Good contour of nasal bone after reduction was showed 71% of group A and 81% of group B without significant difference. Minor (p>0.05) and major (p<0.05) deformity after reduction were less occurred in the group B than group A. Postoperatively, the dose of analgesics was significantly lower after IOR technique than CR technique (53 mg vs. 142 mg) (p<0.05). Conclusion: Algorithm oriented treatment of nasal fracture including IOR and EF as well as CR reduce major deformity after reduction than treatment of CR alone. It is useful to perform the more aggressive reduction techniques such as IOR and EF according to the pattern of fracture in treatment of nasal fracture.

The Correlation between the Degree of Enophthalmos and the Extent of Fracture in Medial Orbital Wall Fracture Left Untreated for Over Six Months: A Retrospective Analysis of 81 Cases at a Single Institution

  • Sung, Yun Sik;Chung, Chan Min;Hong, In Pyo
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.335-340
    • /
    • 2013
  • Background In patients with medial orbital wall fracture, predicting the correlation between the degree of enophthalmos and the extent of fracture is essential for deciding on surgical treatment. We conducted this retrospective study to identify the correlation between the two parameters. Methods We quantitatively analyzed the correlation between the area of the bone defect and the degree of enophthalmos on computed tomography scans in 81 patients with medial orbital wall fracture who had been left untreated for more than six months. Results There was a significant linear positive correlation between the area of the medial orbital wall fracture and the degree of enophthalmos with a formula of E=0.705A+0.061 (E, the degree of enophthalmos; A, the area of bone defect) (Pearson's correlation coefficient, 0.812) (P<0.05). In addition, that there were no cases in which the degree of enophthalmos was greater than 2 mm when the area of the medial orbital wall fracture was smaller than $1.90cm^2$. Conclusions Our results indicate not only that 2 mm of enophthalmos corresponds to a bone defect area of approximately $2.75cm^2$ in patients with medial orbital wall fracture but also that the degree of enophthalmos could be quantitatively predicted based on the area of the bone defect even more than six months after trauma.

Reduction of the Isolated Anterior Wall of the Maxillary Sinus Fracture with Double Urinary Balloon Catheters and Fibrin Glue

  • Kim, Jaehee;Yang, Ho Jik;Kim, Jong Hwan;Kim, Su Jin
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.4
    • /
    • pp.238-242
    • /
    • 2017
  • Background: Conservative treatment is performed for isolated anterior wall of the maxillary sinus fractures, in many cases when the fracture is clinically not severe and asymptomatic. Despite the absence of symptoms, complications such as sinusitis, rhinitis, and chronic purulent secretion may develop; therefore, successful reduction is required. We attempted to reduce the risk of complications using an alternative technique: reduction of the fracture with two urinary balloon catheters inserted through the maxillary ostium and fixation using fibrin glue, which minimizes the damage to the bony fragments and sinus mucosa. Methods: In this study, 38 patients who were diagnosed with an isolated anterior wall of the maxillary sinus fracture at our hospital between January 2014 and January 2017 were enrolled. The fracture site was exposed via the Caldwell-Luc approach followed by reduction through the insertion of two urinary balloon catheters using a nasal endoscope and fixation with fibrin glue. The sex, cause of fracture, physical examination, and presence of complications were examined and patient's medical records and facial bone computed tomography scans were analyzed. Results: Radiological evaluation showed that there was no evidence of collapsed reduction fragments. Although some patients had remaining symptoms of hypoesthesia (15%; 3 patients), there were no complications such as infection, rhinitis, sinusitis, and chronic purulent secretion at the surgical site. Conclusion: In this study, we present an alternative surgical technique using two urinary balloon catheters and fibrin glue for the successful reconstruction of an isolated anterior wall of the maxillary sinus fracture. This technique enables precise restoration with a reduced risk of complications.

The clinical usefulness of closed reduction of nasal bone using only a periosteal elevator with a rubber band

  • Park, Young Ji;Ryu, Woo Sang;Kwon, Gyu Hyeon;Lee, Kyung Suk
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.5
    • /
    • pp.284-288
    • /
    • 2019
  • Background: Closed reduction of nasal fracture with various instrument is performed to treat nasal fracture. Depending on the type of nasal fracture and the situation in which it is being operated, the surgeon will determine the surgical tool. The objective of this study was to investigate whether a periosteal elevator (PE) was a proper device to perform closed reduction for patients with simple nasal fractures. Methods: From March 2018 to December 2018, 50 cases of simple nasal bone fracture underwent closed reduction performed by a single surgeon. These patients were divided into two groups randomly: nasal bone reduction was performed using only PE (freer) and nasal bone reduction was performed using Walsham, Asch forcep, and Boies elevator (non-freer, non-PE). Results: The paranasal sinus computed tomography was performed on patients before and after operation to carry out an accurate measurement of reduction distance at the same level. According to the results, the interaction between instruments and fracture types had a significant influence on reduction distance (p = 0.021). To be specific, reduction distance was significantly (p= 0.004) increased by 2.157 mm when PE was used to treat patients with partial displacement compared to that when non-PEs were used. Conclusion: Closed reduction using PE and other elevator is generally an effective treatment for nasal fracture. In partial-displacement type of simple nasal fracture, closed reduction using PE can have considerable success in comparison with using classic instruments.

Trend analysis of nasal bone fracture

  • Kim, Kwang Seog;Lee, Han Gyeol;Shin, Jun Ho;Hwang, Jae Ha;Lee, Sam Yong
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.4
    • /
    • pp.270-274
    • /
    • 2018
  • Background: Nasal bone fractures occur frequently because the nasal bone is located at the forefront of the face. The goal of this study was to examine the cause, change in severity, change in incidence, and demographics of nasal bone fracture according to today's lifestyle. Methods: A total of 2,092 patients diagnosed as having nasal bone fractures at our department between 2002 and 2017 were included in this study. We retrospectively examined patients' medical records to extract information regarding age, sex, cause of injury, combined facial bone fractures, and related injuries such as skull base fracture, spinal cord injury, brain hemorrhage, and other bone fractures. Fracture severity was classified by nasal bone fracture type. Results: No statistically significant difference was found in annual number of patients treated for nasal bone fracture. The proportion of patients who underwent closed reduction was significantly decreased over time for those with nasal bone fractures caused by traffic accidents. However, it was not significantly changed for those with nasal bone fractures due to other causes. The number of patients with combined facial bone fractures increased over time. Incidences of severe nasal bone fracture also increased over time. Conclusion: The study suggested that there is a decrease in the frequency and increase in the severity of nasal bone fracture due to traffic accident. Many protective devices prevent nasal bone fractures caused by a small amount of external force; however, these devices are not effective against higher amounts of external force. This study highlights the importance of preoperative thorough evaluation to manage patients with nasal bone fractures due to traffic accident.

Do closed reduction and fracture patterns of the nasal bone affect nasal septum deviation?

  • Choi, Jun Ho;Oh, Hyun Myung;Hwang, Jae Ha;Kim, Kwang Seog;Lee, Sam Yong
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.3
    • /
    • pp.119-124
    • /
    • 2022
  • Background: Many severe nasal bone fractures present with septal fractures, causing postoperative septal deviation and negatively affecting the patients' quality of life. However, when a septal fracture is absent, it is difficult to predict whether surgical correction can help minimize nasal septal deviation postoperatively. This study determined whether performing closed reduction on even mildly displaced nasal bone fracture could deter the outcome of septal deviation. Methods: We retrospectively reviewed the data of 116 patients aged 21-72 years who presented at the outpatient clinic and emergency room with fractures of nasal bones only without any involvement of the septum from January 2014 to December 2020. Patients were classified into three fracture type groups: A (unilateral), B (bilateral), and C (comminuted with depression). The degree of septal deviation was calculated by measuring the angle between the apex of the most prominent point and the crista galli in the coronal view on computed tomography images. The difference between the angles of the initial septal deviation and that of the follow-up was calculated and expressed as delta (Δ). Results: Closed reduction tended to decrease the postoperative septal deviation in all fracture types, but the values were significantly meaningful only in type A and B fractures. In the surgical group, with type A as the baseline, type B showed a significantly larger Δ value, but type C was not significantly different, although type C showed a smaller Δ value. In the conservative group, with type A as the baseline, the other fracture types presented significantly lower Δ values. Conclusion: For all fracture types, closed reduction significantly decreased the extent to which the nasal septum likely deviated. Therefore, when a patient is reluctant to undergo closed reduction, physicians should address the possible outcomes and prognosis of untreated nasal bone fractures.

A Study on the Fracture behavior in Silicon Wafer using the Ultra-Precision Micro Positioning System (초미세 위치결정시스템을 이용한 실리콘 웨이퍼의 파괴거동에 관한 연구)

  • 이병룡
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.1
    • /
    • pp.38-44
    • /
    • 2000
  • The background of this study lies in he investigation of the formation mechanism of ductile mode(nkanometer-size) chips of brittle materials such as fine ceramics glass and silicon. As the first step to achieve this purpose this paper intends to observe the micro-deformation behavior of these materials in sub${\mu}{\textrm}{m}$ depth indentation tests using a diamond indentor. In this study it was developed Ultra-Micro Indentation. Device using the PZT actuator. Experimentally by using the Ultra-Micro Indentation device the micro fracture behavior of the silicon wafer was investigated. It was possible that ductile-brittle transition point in ultimate surface of brittle material can be detected by adding an acoustic emission sensor system to the Ultra-Micro Indentation appartus.

  • PDF