• Title/Summary/Keyword: Background counts

Search Result 210, Processing Time 0.031 seconds

Immunological mechanism of Aging : T & B cell changes (면역학적 노화 기전에 관한 연구: T 및 B 세포의 변화)

  • Kim, Jay Sik;Lee, Won Kil;Suh, Jang Soo;Song, Kyung Eun;Lee, Joong Won;Lee, Nan Young;Weksler, Marc E.
    • IMMUNE NETWORK
    • /
    • v.1 no.3
    • /
    • pp.236-243
    • /
    • 2001
  • Background: An immunological approach for aging mechanism appears to be important. Lymphocyte subsets analysis in peripheral blood is widely performed to assess the immune status and to diagnose and monitor various diseases. Some lymphocyte subsets are known to change with age, but only few data about age-related reference ragnes for these subsets in healthy individuals have been reported. So we attempted to report reference ranges for these subsets in each age group and review changes of the results with age for the secondary studies about immune cell function as lymphocyte blast transformation and immunoglobulin gene rearrangement (VDJ) including recombination activating genes (RAG-1 and RAG-2). Methods: Lymphocyte subset analysis was performed on 302 subjects, 189 males and 113 females with age group of all decades of life. Two color direct immunofluorescene flow cytometry (FCM) was done using $Simultest^{TM}$ IMK-Lymphocyte kit (Becton Dickinson, USA), $FACScan^{TM}$ (Becton Dickinson, USA) and $FACSCalibur^{TM}$ (Becton Dickinson, USA). Lymphocyte subsets analysed were T ($CD3^+$) and B cells ($CD19^+$), helper/inducer T ($CD4^+$) and suppressor/cytotoxic T cells ($CD8^+$), helper/suppressor ($CD4^+/CD8^+$) ratio and natural killer (NK) cells ($CD3^-CD16^+/CD56^+$). The absolute numbers of each subset were calculated from total lymphocyte counts. Data collected was analysed using SAS 6.12. A P-value of < 0.05 was considered significant. Results: We reported the counts and percentages of lymphocyte and these subsets in each age group. There were no statistically significant differences between male and female subjects. The percentage of $CD4^+$ T cells, and the count of NK cells did not show the significant difference among the various age groups. The age-related changes observed in our study were as following: 1) a decrease in the percentages of T cells, B cells and $CD8^+$ T cells ; 2) a decrease in the counts of B cells and $CD8^+$ T cells ; 3) an increase in the percentage and count of NK cells ; and 4) an increase in the $CD4^+/CD8^+$ ratio. Conclusion: The characteristics of aging process appeared to be showing a marked decrease of lympocyte subsets T and B cells as well as T8 ($CD8^+$). The age-related increase of the percentage of cells bearing NK marker can be interpreted as a compensatory consequence to cope with the decrease of T cells related to the thymic involution. These changes with age appeared to be for the secondary study about immune cell function as lymphocyte blast transformation and immunoglobulin gene rearrangement.

  • PDF

Lung cancer, chronic obstructive pulmonary disease and air pollution (대기오염에 의한 폐암 및 만성폐색성호흡기질환 -개인 흡연력을 보정한 만성건강영향평가-)

  • Sung, Joo-Hon;Cho, Soo-Hun;Kang, Dae-Hee;Yoo, Keun-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.3 s.58
    • /
    • pp.585-598
    • /
    • 1997
  • Background : Although there are growing concerns about the adverse health effect of air pollution, not much evidence on health effect of current air pollution level had been accumulated yet in Korea. This study was designed to evaluate the chronic health effect of ai. pollution using Korean Medical Insurance Corporation (KMIC) data and air quality data. Medical insurance data in Korea have some drawback in accuracy, but they do have some strength especially in their national coverage, in having unified ID system and individual information which enables various data linkage and chronic health effect study. Method : This study utilized the data of Korean Environmental Surveillance System Study (Surveillance Study), which consist of asthma, acute bronchitis, chronic obstructive pulmonary diseases (COPD), cardiovascular diseases (congestive heart failure and ischemic heart disease), all cancers, accidents and congenital anomaly, i. e., mainly potential environmental diseases. We reconstructed a nested case-control study wit5h Surveillance Study data and air pollution data in Korea. Among 1,037,210 insured who completed? questionnaire and physical examination in 1992, disease free (for chronic respiratory disease and cancer) persons, between the age of 35-64 with smoking status information were selected to reconstruct cohort of 564,991 persons. The cohort was followed-up to 1995 (1992-5) and the subjects who had the diseases in Surveillance Study were selected. Finally, the patients, with address information and available air pollution data, left to be 'final subjects' Cases were defined to all lung cancer cases (424) and COPD admission cases (89), while control groups are determined to all other patients than two case groups among 'final subjects'. That is, cases are putative chronic environmental diseases, while controls are mainly acute environmental diseases. for exposure, Air quality data in 73 monitoring sites between 1991 - 1993 were analyzed to surrogate air pollution exposure level of located areas (58 areas). Five major air pollutants data, TSP, $O_3,\;SO_2$, CO, NOx was available and the area means were applied to the residents of the local area. 3-year arithmetic mean value, the counts of days violating both long-term and shot-term standards during the period were used as indices of exposure. Multiple logistic regression model was applied. All analyses were performed adjusting for current and past smoking history, age, gender. Results : Plain arithmetic means of pollutants level did not succeed in revealing any relation to the risk of lung cancer or COPD, while the cumulative counts of non-at-tainment days did. All pollutants indices failed to show significant positive findings with COPD excess. Lung cancer risks were significantly and consistently associated with the increase of $O_3$ and CO exceedance counts (to corrected error level -0.017) and less strongly and consistently with $SO_2$ and TSP. $SO_2$ and TSP showed weaker and less consistent relationship. $O_3$ and CO were estimated to increase the risks of lung cancer by 2.04 and 1.46 respectively, the maximal probable risks, derived from comparing more polluted area (95%) with cleaner area (5%). Conclusions : Although not decisive due to potential misclassication of exposure, these results wert drawn by relatively conservative interpretation, and could be used as an evidence of chronic health effect especially for lung cancer. $O_3$ might be a candidate for promoter of lung cancer, while CO should be considered as surrogated measure of motor vehicle emissions. The control selection in this study could have been less appropriate for COPD, and further evaluation with another setting might be necessary.

  • PDF

The Evaluation of Resolution Recovery Based Reconstruction Method, Astonish (Resolution Recovery 기반의 Astonish 영상 재구성 기법의 평가)

  • Seung, Jong-Min;Lee, Hyeong-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Kim, Joong-Hyun;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.58-64
    • /
    • 2011
  • Objective: The 3-dimensional reconstruction method with resolution recovery modeling has advantages of high spatial resolution and contrast because of its precise modeling of spatial blurring according to the distance from detector plane. The aim of this study was to evaluate one of the resolution recovery reconstruction methods (Astonish, Philips Medical), compare it to other iterative reconstructions, and verify its clinical usefulness. Materials and Methods: NEMA IEC PET body phantom and Flanges Jaszczak ECT phantom (Data Spectrum Corp., USA) studies were performed using Skylight SPECT (Philips) system under four different conditions; short or long (2 times of short) radius, and half or full (40 kcts/frame) acquisition counts. Astonish reconstruction method was compared with two other iterative reconstructions; MLEM and 3D-OSEM which vendor supplied. For quantitative analysis, the contrast ratios obtained from IEC phantom test were compared. Reconstruction parameters were determined by optimization study using graph of contrast ratio versus background variability. The qualitative comparison was performed with Jaszczak ECT phantom and human myocardial data. Results: The overall contrast ratio was higher with Astonish than the others. For the largest hot sphere of 37 mm diameter, Astonish showed about 27.1% and 17.4% higher contrast ratio than MLEM and 3D-OSEM, in short radius study. For long radius, Astonish showed about 40.5% and 32.6% higher contrast ratio than MLEM and 3D-OSEM. The effect of acquired counts was insignificant. In the qualitative studies with Jaszczak phantom and human myocardial data, Astonish showed the best image quality. Conclusion: In this study, we have found out that Astonish can provide more reliable clinical results by better image quality compared to other iterative reconstruction methods. Although further clinical studies are required, Astonish would be used in clinics with confidence for enhancement of images.

  • PDF

Assessment of Magnetic Resonance Image Quality For Ferromagnetic Artifact Generation: Comparison with 1.5T and 3.0T. (강자성 인공물 발생에 대한 자기공명영상 질 평가: 1.5T와 3.0T 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.193-199
    • /
    • 2018
  • In this research, 15 patients were diagnosed with 1.5T and 3.0T MRI instruments (Philips, Medical System, Achieva) to minize Ferromagnetic artifact and find the optimized Tesla. Based on the theory that the 3.0T, when compared to 1.5T, show relatively high signal-to-ratio(SNR), Scan time can be shortened or adjust the image resolution. However, when using the 3.0T MRI instruments, various artifact due to the magnetic field difference can degrade the diagnostic information. For the analysis condition, area of interest is set at the background of the T1, T2 sagittal image followed by evaluation of L3, L4, L5 SNR, length of 3 parts with Ferromagnetic artifact, and Histogram. The validity evaluation was performed by using the independent t test. As a result, for the SNR evaluation, mere difference in value was observed for L3 between 1.5T and 3.0T, while big differences were observed for both L4, and L5(p<0.05). Shorter length was observed for the 1.5T when observing 3 parts with Ferromagnetic artifact, thus we can conclude that 3.0T can provide more information on about peripheral tissue diagnostic information(p<0.05). Finally, 1.5T showed higher counts values for the Histogram evaluation(p<0.05). As a result, when we have compared the 1.5T and 3.0T with SNR, length of Ferromagnetic artifact, Histogram, we believe that using a Low Tesla for Spine MRI test can achieve the optimal image information for patients with disk operation like PLIF, etc. in the past.

Study a Technique for Reducing the Influence of Scattered Rays from Surrounding Organs to the Heart during Gated Cardiac Blood Pool scan (Gated Cardiac Blood Pool scan에서의 심장 주위 배후방사능 관심영역 설정시 산란선의 영향을 감소시키기 위한 연구)

  • Kim, Jung-Yul;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.33-38
    • /
    • 2008
  • Purpose: The Gated cardiac blood pool scan is non-invasive method that a quantitative evaluation of left ventricular function. Also this scan have shown the value of radionuclide ejection fraction measurements during the course of chemotherapy as a predictor of cardiac toxicity. Therefore a reliable method of monitoring its cardiotoxic effects is necessary. the purpose of this study is to minimize the overestimate of left ventricular ejection fraction (LVEF) by modified body position to reduce the influence of scattered rays from surrounding organs of the heart in the background region of interest. Materials and Methods: Gated cardiac blood pool scan using in vivo $^{99m}Tc$-red blood cell (RBC) was carried out in 20 patients (mean $44.8{\pm}8.6$ yr) with chemotherapy for a breast carcinoma. Data acquisition requires about 600 seconds and 24 frames of one heart cycle by the multigated acquisition mode, Synchronization deteriorates toward the end of the cycle and with the distance from the trigger signal (R-wave) by ECG gating. Gated cardiac blood pool scan was studied with conventional method (supine position and the detector head in $30-45^{\circ}$ left anterior oblique position and caudal $10-20^{\circ}$ tilt) and compared with modified method (left lateral flexion position with 360 mL of drinking water). LVEF analysis was performed by using the automatically computer mode. Results: The ROI counts of modified scan method were lower than LV conventional method ($1429{\pm}251$ versus $1853{\pm}243$, <0.01). And LVEF of modified method was also decrease compared with conventional method ($58.3{\pm}5.6%$ versus $65.3{\pm}6.1%$, <0.01). Imaging analysis indicated that stomach was expanded because of water and spleen position was changed to lateral inferior compared with conventional method. Conclusion: This study shows that the modified method in MUGA reduce the influence of scattered rays from surrounding organs. Because after change the body position to left lateral flexion and drinking water, the location of spleen, left lobe of liver and stomach had changed and they could escaped from background ROI. Therefore, modified method could help to minimize the overestimate LVEF (%).

  • PDF

Analysis of 226Ra in the Groundwater Using the Gamma-ray Spectroscopy (감마선 분광법을 이용한 지하수 중의 226Ra 분석)

  • Seo, Bum-Kyoung;Lee, Kil-Yong;Yoon, Yoon-Yeol;Lee, Kune-Woo
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.39-47
    • /
    • 2003
  • The measurement of radium ($^{226}Ra$) in the groundwater was established using ${\gamma}$-ray spectroscopy without sample preparation. The background interference by air borne radon daughter nuclides was reduced by $N_2$ gas flow into the counting chamber. Leakage of radon gas produced in the radioactive equilibrium with radium and its daughter nuclides was prevented by use of the air-tighted aluminium container. We investigated the effect of air layer in the counting container. Radioactivity variation due to emanation of radon into the air layer was within the counting error range 5%. When the nitrogen gas was flowed around the detector, peak counts of ${\gamma}$-rays from the daughters of airborne radon was decreased and detection limit was decreased to 0.02 Bq/L. The detection limit of detector was lower than 0.74 Bq/L, the $^{226}Ra$ Maximum Contaminant Level (MCL) in the groundwater proposed by US Environmental Protection Agency (EPA). It was confirmed that $^{226}Ra$ radioactivity in the groundwater could be determined by the ${\gamma}$-ray spectroscopy.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

The Consideration of the Region of Interest on $^{99m}Tc$-DMSA Renal Scan in Pediatric Hydronephrosis Patients (수신증을 진단 받은 소아 환자의 DMSA 신장 검사에서 정확한 관심영역 설정에 대한 고찰)

  • NamKoong, Hyuk;Lee, Dong-Hyuk;Oh, Shin-Hyun;Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2012
  • Purpose: Most of diagnosis in the pediatric hydronephrosis patients have been performed $^{99m}Tc$-DMSA renal scan. Then the region of interest (ROI) is set for comparative analysis of uptake ratio in left-right kidney after acquiring the image. But if the equipment set an automatic ROI, the ROI could include expanded renal pelvis due to hydronephrosis and the uptake ratio of left-right kidney will be incorrect result. Therefore this study compared both ROIs including expanded renal pelvis and excluding renal pelvis through experiment using normal kidney phantom and expanded renal pelvis phantom and suggested setting method of improved ROI. In addition, this study have been helped by readout doctor for investigate distinction radiopharmaceutical uptake between renal cortex and remained urine by expanded renal pelvis. Materials and Methods: The both of renal phantoms were filled with water and shacked with $^{99m}TcO_4$ 111 MBq. In order to describe the expanded renal pelvis, the five latex balloon were all filled with 10 mL water and each of balloon was mixed with $^{99m}TcO_4$ 18.5, 37, 55.5, 74, 92.5 MBq. And we made phantom with fixed $^{99m}TcO_4$activity of 37 MBq and mixed water 5, 10, 15, 20, 25 mL in each balloon. The left kidney was fixed its shape and the right kidney was modified like as hydronephrosis kidney by attached the latex balloons. And the acquiring counts were 2 million. After acquisition, we compared the image of ROI with Expanded renal pelvis and the image of ROI without renal pelvis for analyzing difference in the uptake ratio of left-right kidney and for reproducibility, set the ROI 5 times in the same images. Patients were injected $^{99m}Tc$-DMSA 1.5~1.9 MBq/kg and scanned 3 to 4 hours after injection. The each of 3 skillful radio technologists performed the comparing estimation by setting ROI. To determine statistical significance between two data, SPSS (ver. 17) Wilcoxon Signed Ranks Test was used. Results: As a result of renal phantom's experiment, we compared with average of counts Background (BKG) ratios in the setting of ROI including expanded renal pelvis and setting of excluding expanded renal pelvis. Therefore, they can obtain changed counts and changed ratios. Patient also can obtain same results. In addition, the radiopharmaceutical uptake in expanded renal pelvis was come out the remained urine that couldn't descend to ureter by the help of readout doctor. Conclusion: As above results, the case of setting ROI including expanded renal pelvis was more abnormally increasing uptake ratio than the case of setting ROI excluding expanded renal pelvis in analysis the uptake ratio in left-right kidney of hydronephrosis. Because of the work convenience and prompted analysis, the automatic ROI is generally used. But in case of the hydronephrosis study, we should set the manual ROI without expanded renal pelvis for an accurate observation of the uptake ratio of left-right kidney since the radiopharmaceutical uptake in expanded renal pelvis is the remained urine.

  • PDF

The Influences of Perfusion Temperature on Inflammatory and Hematologic Responses during Cardiopulmonary Bypass (체외순환시 염증과 혈액학적 반응에 대한 관류온도의 영향)

  • 김상필;최석철;박동욱;한일용;이양행;조광현;황윤호
    • Journal of Chest Surgery
    • /
    • v.37 no.10
    • /
    • pp.817-826
    • /
    • 2004
  • Background: Several studies have demonstrated that conventional hypothermic cardiopulmonary bypass (CPB) causes cellular injury, abnormal responses in peripheral vascular beds and increased postoperative bleeding, whereas normothermic CPB provides protection of the hypothermic-induced effects and better cardiac recovery. The present study was prospectively performed to compare the effects of normothermic CPB to those of hypothermic CPB on the inflammatory and hematologic responses during cardiac surgery. Material and Method: Thirty-four adult patients scheduled for elective cardiac surgery were randomly assigned to hypothermic CPB (nasopharyngeal temperature $26~28^{\circ}C,$ n=17) or normothermic CPB (nasopharyngeal $temperature>35.5^{\circ}C,$ n=17) group. In both groups, cold $(4^{\circ}C)$ crystalloid cardioplegia was applied for myocardial protection. Blood samples were drawn from radial artery before (Pre-CPB), 10 minutes after starting (CPB-10) and immediately after ending (CPB-OFF) CPB. Total leukocyte and platelet counts, interleukin-6 (IL-6) level(expressed as percent to the baseline of Pre-CPB), D-dimer level, protein C and protein S activity were measured with the blood samples. The amount of bleeding for postoperative 24 hours and blood transfusion after operation were also assessed. All parameters were compared between the two groups. Result: The total leukocyte counts $(10,032\pm65/mm^3)$ and the increased ratio of IL-6 $(353\pm7.0%)$ at CPB-OFF in the normothermic group were higher than that $(7,254\pm48/mm^3$ and $298\pm7.3%)$ of the hypothermic group(p=0.02 and p=0.03). In the normothermic group, protein C activity $(32\pm3.8%)$ and protein S activity $(35\pm4.1%)$ at CPB-OFF were significantly lower than that $(45\pm4.3%$ and $51\pm3.8%)$ of the hypothermic group (p=0.04 and p=0.009). However, there were no differences in platelet counts and D-dimer concentration. In the normothermic group, the amount of bleeding for postoperative 24 hours $(850\pm23.2$ mL) and requirements for blood transfusion after operation such as packed cell $(1,402\pm20.5$ mL), fresh frozen plasma $(970\pm20.8$ mL) and platelet $(252\pm6.4$ mL) were higher than that $(530\pm21.5$ mL, $696\pm15.7$ mL, $603\pm18.2$ mL and $50\pm0.0$ mL) of the hypothermic group. Conclusion: These results indicate that normothermic CPB with cold crystalloid cardioplegia was associated with higher increase in inflammatory response, hemostatic abnormalities and postoperative bleeding problem than moderate hypothermic CPB.

An Appreciation of Functional Role of Macrophage in the Acute Lung Injury in the Neutropenic Rat. (호중구 감소증을 보이는 백서의 급성폐손상에서 대식세포의 기능적 역할)

  • Kim, Yong-Hoon;Ki, Sin-Young;Im, Keon-Il;Moon, Seung-Hyug;Cheong, Seung-Whan;Kim, Hyeon-Tae;Uh, Soo-Taek;Park, Choon-Sik;Jin, Byung-Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.379-390
    • /
    • 1997
  • Background : It has long been suggested that neutrophils and their products are implicated as the central mediators of the acute lung injuries. Contrary to the dominant role of neutrophils in ARDS, many cases of ARDS has occurred in the setting of severe neutropenia without pulmonary neutrophil infiltration. Therefore it is certain that effector cell(s) other than neutrophil play an important role in the pathogenesis of ARDS. This experiment was performed to define the mechanism of ARDS in the setting of neutropenia, 1) by comparing the severity of endotoxin-induced lung injury, 2) by measurement of hydrogen peroxide production and cytokine concentration in the bronchoalveolar lavage cells and fluids obtained from different rats with and without cyclophosphamide-pretreatment. Method : The male Sprague-Dawleys were divided into the normal control (NC)-, endotoxin (ETX)-, and cyclophosphamide (CPA)-group in which neutropenia was induced by injecting cyclophosphamide intraperitoneally. Acute lung injury was evoked by injecting lipopolysaccharide (LPS) into a tail vein. The bronchoalveolar lavage (BAL) was performed at 3 and 6 hour after administration of LPS to measure the change of cell counts and concentrations of protein and cytokines, tumor necrosis factor-alpha (TNF-alpha) and interleukin-6 (IL-6). Hydrogen peroxide (HPO) production from BAL cells was measured at 6 hour after LPS administration by phenol red microassay with and without zymosan stimulation. Results : The results were as follows. A change of leukocyte counts in the peripheral blood after treatment with CPA : More than 95% of total leukocytes and neutrophils were reduced after CPA administration, resulting in severe neutropenia. A change of BAL cells : In the ETX-group, the number of total cells (p < 0.01) and of macrophage and neutrophil (p < 0.05) were increased at 3 and 6 hour after LPS administration compared to those of NC-group. In the CPA-group, the number of total leukocyte and macrophage were not changed after LPS administration, but neutrophil counts were significantly reduced and it took part in less than 0.1% of total BAL cells (p < 0.01 vs NC-group). BAL cells in this group were almost all macrophages (99.7%). A change of protein concentration in the BALF : In the ETX-group, protein concentration was increased at 3 hour and was more increased at 6 hour after LPS administration (p < 0.05 and < 0.01 vs NC-group, respectively). In the CPA-group, it was also significantly elevated at 3 hour after LPS administration (p < 0.05 vs NC-group), but the value was statistically not different from that of ETX-group. The value measured at 6 hour after LPS administration in the CPA-group became lower than that of ETX-group (p < 0.05), but showed still a higher value compared to that of NC-group (p < 0.05). A change of cytokine concentration in the BALF : TNF -alpha and IL-6 were elevated in the ETX - and CPA-group compared to those of NC-group at both time intervals. There was no statistical difference in the values of both cytokines between the ETX- and CPA-groups. Measurement of hydrogen peroxide production from BAL cells : There was no intergroup difference of HPO production from resting cells. HPO production after incubation with opsonized zymosan was significantly elevated in all groups. The percent increment of HPO production was highest in the ETX-group (89.0%, p < 0.0008 vs NC-group), and was 42.85 in the CPA-group (p = 0.003 vs NC-group ). Conclusion : Acute lung injury in the setting of neutropenia might be caused by functional activation of resident alveolar macrophages.

  • PDF