• 제목/요약/키워드: Back-to-back converter

검색결과 218건 처리시간 0.049초

Output Power Control of Wind Generation System by Machine Loss Minimization

  • Abo-Khalil Ahmed;Lee Dong-Choon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.51-54
    • /
    • 2005
  • Generator efficiency optimization is important for economic saving and environmental pollution reduction. In general, the machine loss can be reduced by the decreasing the flux level, resulting in the significant reduction of the core loss. This paper proposesan model-based controller is used to decrement the excitation current component on the basis of measured stator current and machine parameters and the q-axis current component controls the generator torque, by which the speed of the induction generator iscontrolled according to the variation of the wind speed in order to produce the maximum output power. The generator reference speed is adjusted according to the optimum tip-speed ratio. The generated power flows into the utility grid through the back-to-back PWM converter. The grid-side converter controls the dc link voltage and the line-side power factor by the q-axis and the d-axis current control, respectively. Experimental results are shown to verify the validity of the proposed scheme.

  • PDF

36-펄스 전압원 컨버터로 구성된 Back-to-Back HVDC 시스템의 실험적 분석 (Experimental Analysis of Back-to-Back HVDC System Composed of 36-pulse Voltage Source Converter)

  • 박용희;조윤호;이두영;이동근;한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.66-68
    • /
    • 2006
  • 본 논문은 펄스 삽입 보조 회로를 갖고 있는 12-펄스 브리지 4대를 사용한 36-펄스 back-to-back 전압원 컨버터를 제안한다. 제안된 back-to-back 전압원 컨버터는 교류 연계점에서 유효전력과 무효전력의 독립적인 제어가 가능하다. 펄스 수를 증가하는 원리는 이론적 접근을 사용하여 분석되었다. 제안된 시스템의 동작 타당성은 PSCAD/EMTDC 소프트웨어의 시뮬레이션을 통해 검증되었다. 하드웨어 구현 타당성을 검증하기 위해 축소모형을 제작하고 실험에 의해 분석하였다. 제안된 back-to-back 전압원 컨버터는 HVDC와 FACTS 장치로 널리 사용될 수 있다.

  • PDF

펄스다중화 보조회로를 이용한 36-펄스 Back-to-Back 전압원 컨버터 (36-pulse Back-to-Back Voltage Source Converter with Pulse-Interleaving Auxiliary Circuit)

  • 최준영;백승택;배병열;한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.6-8
    • /
    • 2005
  • 본 논문은 펄스 삽입 보조 회로를 갖고 있는 12-펄스 브리지 4대를 사용한 36-펄스 back-to-back 전압원 컨버터를 제안한다. 제안된 back-to-back 전압원 컨버터는 교류 연계점에서 유효전력과 무효전력의 독립적인 제어가 가능하다. 펄스 수를 증가하는 원리는 이론적 접근을 사용하여 분석되었다. 제안된 시스템의 동작 타당성은 PSCAD/EMTDC 소프트웨어의 시뮬레이션을 통해 검증되었다. 제안된 back-to-back 전압원 컨버터는 HVDC와 FACTS 장치로 널리 사용될 수 있다.

  • PDF

Back to bock 컨버터를 갖는 가변속 풍력터빈 시스템의 모델링과 해석 (Modeling and Analysis of Variable Wind Speed Turbine System Using Back to Back Converter)

  • 김일환;강경보;김재홍;문상호;오성보;김세호
    • 조명전기설비학회논문지
    • /
    • 제19권8호
    • /
    • pp.150-157
    • /
    • 2005
  • 본 논문에서는 이중여자 유도발전기의 회전자에 back to back 컨버터가 채용된 가변속 풍력터빈 시스템의 모델링과 해석을 나타내었다. 제어시스템의 특성을 파악하기 위해서 시뮬레이션에서는 Psim 프로그램을 사용하여 660[kW] 의 출력정격을 갖는 시스템을 모델로 하였다. 모델링에서는 블레이드 제어 시스템 모델과 회전자와 계통선에 연결된 컨버터 시스템을 모델링 하였다. 풍속의 변화에 따라 원하는 출력을 얻을 수 있도록 피치각을 제어하여 정격풍속 이하에서도 최대출력이 발생하도록 하였고, 정격풍속 이상에서는 회전자 속도를 일정하게 하여 정격출력을 유지할 수 있도록 하였다. 또한 무효전력을 제어하여 출력의 역률을 제어하였다. 제안한 해석방법의 타당성을 검증하기 위하여 풍속변화에 따른 모델 시스템의 시뮬레이션 결과 값들과 제주행원 풍력발전 단지에서 운용되고 있는 V47 660[kW] 시스템의 실측 결과들과 서로 비교 검증하여 제안한 해석 방법의 타당성을 입증하였다.

Buck-Flyback (fly-buck) Stand-Alone Photovoltaic System for Charge Balancing with Differential Power Processor Circuit

  • Lee, Chun-Gu;Park, Jung-Hyun;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.1011-1019
    • /
    • 2019
  • In this paper, a buck-flyback (fly-buck) stand-alone photovoltaic (PV) system for charge balancing with a differential power processor (DPP) circuit is proposed. Conventional feed-back DPP converters draw differential feed-back power from the output of a string converter. Therefore, the power is always through the switches and diodes of the string converter. Because of the returning conduction path, there are always power losses due to the resistance of the switch and the forward voltage of the diode. Meanwhile, the proposed feed-back DPP converter draws power from the magnetically-coupled inductor in a string converter. This shortens the power path of the DPP converter, which reduces the power losses. In addition, the extra winding in the magnetically-coupled inductor works as a charge balancer for battery-stacked stand-alone PV systems. The proposed system, which uses a single magnetically-coupled inductor, can control each of the PV modules independently to track the maximum power point. Thus, it can overcome the power loss due to the power path. It can also achieve charge balancing for each of the battery modules. The proposed topology is analyzed and verified using 120W hardware experiments.

3상 계통연계형 Back to Back 컨버터의 동특성 개선 방법 (A Compensation Method to Improve Dynamic Characteristic of Three-Phase Grid-Connected Back to Back Converter)

  • 조진호;최성촌;김범준;김정민;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 추계학술대회 논문집
    • /
    • pp.77-78
    • /
    • 2016
  • 본 논문에서는 양방향 전력공급이 가능한 3상 Back to Back 컨버터에 필요한 여러 가지 제어 기술들을 살펴보고 시뮬레이션을 통해 제어 알고리즘의 타당성을 분석하며, 입, 출력 전압, 전류 등 파형을 관찰하고 전력을 가변시킬 때 나타나는 3상 계통연계형 Back to Back 컨버터의 동특성을 개선하는 방법을 알아본다.

  • PDF

새로운 18-step 전압원 컨버터를 이용한 Back-to-Back 계통연계시스템 (Back-to-Back Interconnection System using New 18-step Voltage Source Converter)

  • 이혜연;이지헌;한병문;리위룽;김수열;장병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.62-64
    • /
    • 2008
  • 본 연구에서는 펄스다중화 보조회로론 이용한 18-step Back-to-Back 전압원 컨버터를 제안한다. 제안하는 Back--Back 전압원 컨버터는 교류연계점에서 유 무효전력의 독립적인 제어가 가능하다. 펄스수를 증가시키는 방법은 이론적인 접근을 통해 분석하였으며, 제안하는 시스템의 동작은 PSCAD/EMTDC 소프트웨어로 시뮬레이션 모델을 개발하여 확인하였고 실질적인 성능검증은 하드웨어 축소모형을 제작하고 실험을 통해 실시 하였다.

  • PDF

3상/단상 BTB 전압형 컨버터 기반의 전기철도 급전 시스템의 전압제어 향상을 위한 BESS 적용 (BESS Application to Voltage Compensation of AC Railway System based on 3ϕ/1ϕ BTB Voltage Source Converter)

  • 유형준;신승권;정호성;김학만
    • 전기학회논문지
    • /
    • 제63권11호
    • /
    • pp.1588-1593
    • /
    • 2014
  • The scott transformer changes three-phase power to two single-phase power. However, this method causes unbalance and fluctuation of voltage by the change of electric railload. Recently, the AC railway system based on $3{\Phi}/1{\Phi}$ back-to-back (BTB) voltage source converter (VSC) has been proposed to solve these problems. Meanwhile, battery energy storage system (BESS) is used to compensate voltage instantaneously in power system. In this paper, BESS application to the AC railway system based on $3{\Phi}/1{\Phi}$ BTB VSC is suggested to compensate voltage instantaneously. The application effect is shown through simulation using MATLAB/SIMULINK.

스텝모터 역기전력을 이용한 폐루프 시스템 구현에 관한 연구 (A study on the implementation of closed-loop system using the stepper motor back-EMF)

  • 임성빈;정상화
    • 대한안전경영과학회지
    • /
    • 제17권3호
    • /
    • pp.363-370
    • /
    • 2015
  • In this paper, the control technique of the stepping motor using back electromotive force(B-EMF) without encoder is investigated. The stepping motor generally uses the rotary encoder to detect the rotor position. Since this method increases the cost and the motor configuration size, the new closed-loop control method applied for the B-EMF was implemented by using current detect circuit, AD-converter, and micro controller unit(MCU). The control loop of stepping motor became very simplified. The current change of stepping motor measured by the amplifier was measured and analyzed, when the missing step is occurred. Based on the data from current feedback, position errors were compensated and confirmed by using AD-converter.