• Title/Summary/Keyword: Back Panel

Search Result 184, Processing Time 0.024 seconds

Validation of the Korean Version of the St. George's Respiratory Questionnaire for Patients with Chronic Respiratory Disease (한국어판 세인트조지 호흡기설문의 타당도와 신뢰도 검정)

  • Kim, Young Sam;Byun, Min Kwang;Jung, Wou Young;Jeong, Jae Hee;Choi, Sang Bong;Kang, Shin Myung;Moon, Ji Ae;Han, Jung Suk;Nam, Chung-Mo;Park, Moo Suk;Kim, Se Kyu;Chang, Joon;Ahn, Chul Min;Kim, Sung Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.2
    • /
    • pp.121-128
    • /
    • 2006
  • Background: The "health-related quality of life" (HRQL) for patients with chronic respiratory disease has been emphasized, because chronic respiratory disease (CRD) is chronic and progressive, and it finally causes disability. HRQL instruments may be useful for monitoring patients' progress or for determining the most appropriate choice of treatment. We describe the adapting St George's Respiratory Questionnaire (SGRQ), which is a self-administered questionnaire developed by Jones et al. (1991), into the Korean version for covering three domains of health for the patients suffering with airways disease. Method: We obtained the original SGRQ from the author after gaining permission. For adaptation, we created an expert panel and translated the original questionnaire into Korean language. The translated questionnaire was then back-translated by bilingual experts and we compared it with the original questionnaire. After correction and feasibility testing, 74 patients with chronic respiratory disease (COPD, asthma, destroyed lung) completed the Korean version of the SGRQ. The clinical status of each patients was evaluated concurrently with measurement of their health status. Result: The Korean version of the SGRQ was acceptable and easy to understand. Cronbach's alpha reliability coefficient was 0.92 for the overall scale and 0.63 for the "Symptoms", subscale, 0.87 for the "Activity", subscale, and 0.89 for the "Impacts" subscales. The correlation coefficients between the overall score and the Borg scale score, oxygen saturation, and forced expiratory volume in one second ($FEV_1$) were 0.52, -0.32 and -0.26, respectively. These results support that the Korean SGRQ was correlated with other measurements. Conclusion: The Korean SGRQ was reliable and valid for patients with chronic respiratory disease, such as COPD, asthma, and destroyed lung. The SGRQ score was well correlated with other respiratory measurements as well. Although further studies should complete the adaptation work, our results suggest that the SGRQ may be used in Korea and also for international studies involving Korean CRD patients.

Study on Comparison of Growth Performance, Feed Efficiency and Carcass Characteristics for Holstein and F1(Holstein ♀ x Hanwoo ♂) Steers and Heifers (Holstein과 교잡종 거세우 및 처녀우의 성장발육, 사료이용성 및 도체특성 비교 연구)

  • Kang, S.W.;Oh, Y.K.;Kim, K.H.;Choi, C.W.;Son, Y.S.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.593-606
    • /
    • 2005
  • Present study was conducted to investigate the optimal feeding levels for producing the high quality meat on the basis of the information deriving from the comparison of the growth performance and carcass characteristics among breeds(Holstein vs F1, Holstein♀×Hanwoo♂), sex(steer vs heifer) and interaction between breed and sex. Thirty two animals on 4 treatments(i.e. eight head each) were used for 540 days from seven to 24 months of age. The results obtained are summarized as follows; the range of average daily gains was 0.733 to 1.018, 0.994 to 1.255, 0.947 to 1.259 and 0.736 to 0.824kg for the growing, the early-fattening, the mid- fattening and the finishing periods, respectively. The range of average daily gains for the entire period was 0.882 to 1.061kg. The gains were higher for Holstein(7.3%) and the steers(10.5%) than F1 and the heifers, respectively. Concentrates and total digestible nutrients intakes per kg gain were higher for Holstein and the heifers than F1 and the steers, respectively. These findings may indicate that feed utilization is higher for Holstein than F1, and higher for the steers than the heifers. In carcass characteristics, back fat thickness was thicker for Holstein than F1, and rib-eye area was smaller for Holstein than F1. The rib-eye area per kg carcass weight was larger for F1 and the heifers than Holstein and the steers, respectively. Meat color was better for Holstein than F1, but the sex distinction did not show any differences. In physicochemical properties of longissimus dorsi, shear force, cooking loss, water holding capacity and the panel test scores of juiciness, tenderness and flavor for F1 and the heifers were better than those for Holstein and the steers, respectively. According to the above results, we may conclude that F1 and heifers rather than Holstein and steers are recommended for high quality meat production. In steers and heifers of Holstein and F1, the optimal feeding levels may be 1.9% of apparent body weight for concentrates and 25% of concentrates intake for rice straw.

Production and Assessing Usefulness of the Moving Phantom for Respiration Gated Radiotherapy (호흡동조 방사선치료용 팬텀의 제작 및 유용성 평가)

  • Lee, Yang-Hoon;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.135-144
    • /
    • 2010
  • Purpose: The purpose of this study is that through production of phantom for respiration gated radiotherapy, assessing appropriacy of exposure dose for the therapy using RPM (Real-time Position Management). Materials and Methods: We located measurement object on the phantom for respiration gated radiotherapy made of 2 linear actuator, acrylic panel, stanchion, iron plate ets. to drive (up, down, front, back). Using 4D CT scan, we analyzed patient's respiration and reproduced the movement by computer. On the phantom, we located a 2D-Array (PTW) and an White water phantom (4.5 cm) and used DMLC (interval 2 cm) in the field size $10{\times}10\;cm$, then exposed 21EX X-ray 100 MU, in the case of phantom was (1) static (2) moving (3) gated using RPM respectively gantry $0^{\circ}$ and $90^{\circ}$ We measured with a 0.125 CC ionization chamber (PTW) on the phantom (7.5 cm) in the same condition. Results: Ionization chamber: There were within 0.3% of error with gating respiration and approximately 2% of error without gating in the same condition. 2D-Array: Gantry $90^{\circ}$, field size $10{\times}10\;cm$, using DMLC. There were within 3% of error with gating respiration and approximately 16% of error without gating. Conclusion: The phantom for respiration gated radiotherapy makes plans considering patient's movement, quantitative analysis of exposure dose and proper assessment therapy for IMRT patients using RPM possible.

  • PDF

Function of the Neuronal $M_2$ Muscarinic Receptor in Asthmatic Patients (천식 환자에서 $M_2$ 무스카린성 수용체 기능에 관한 연구)

  • Kwon, Young-Hwan;Lee, Sang-Yeup;Bak, Sang-Myeon;Lee, Sin-Hyung;Shin, Chol;Cho, Jae-Youn;Shim, Jae-Jeong;Kang, Kyung-Ho;Yoo, Se-Hwa;In, Kwang-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.4
    • /
    • pp.486-494
    • /
    • 2000
  • Background : The dominant innervation of airway smooth muscle is parasympathetic fibers which are carried in the vagus nerve. Activation of these cholinergic nerves releases acetylcholine which binds to $M_3$ muscarinic receptors on the smooth muscle causing bronchocontraction. Acetylcholine also feeds back onto neuronal $M_2$ muscarinic receptors located on the postganglionic cholinergic nerves. Stimulation of these receptors further inhibits acetylcholine release, so these $M_2$, muscarinic receptors act as autoreceptors. Loss of function of these $M_2$ receptors, as it occurs in animal models of hyperresponsiveness, leads to an increase in vagally mediated hyperresponsiveness. However, there are limited data pertaining to whether there are dysfunctions of these receptors in patients with asthma. The aim of this study is to determine whether there are dysfunction of $M_2$ muscarinic receptors in asthmatic patients and difference of function of these receptors according to severity of asthma. Method : We studied twenty-seven patients with asthma who were registered at Pulmonology Division of Korea University Hospital. They all met asthma criteria of ATS. Of these patients, eleven patients were categorized as having mild asthma, eight patients moderate asthma and eight patients severe asthma according to severity by NAEPP Expert Panel Report 2(1997). All subjects were free of recent upper respiratory tract infection within 2 weeks and showed positive methacholine challenge test ($PC_{20}$<16mg/ml). Methacholine provocation tests were performed twice on separate days allowing for an interval of one week. In the second test, pretreatment with the $M_2$ muscarinic receptor agonist pilocarpine($180{\mu}g$) through inhalation was performed be fore the routine procedures. Results : Eleven subjects with mild asthma and eight subjects with moderate asthma showed significant increase of $PC_{20}$ from 5.30$\pm$5.23mg/ml(mean$\pm$SD) to 20.82$\pm$22.56mg/ml(p=0.004) and from 2.79$\pm$1.51mg/ml to 4.67$\pm$3.53mg/ml(p=0.012) after pilocarpine inhalation, respectively. However, in the eight subjects with severe asthma significant increase of $PC_{20}$ from l.76$\pm$1.50mg/ml to 3.18$\pm$4.03mg/ml(p=0.161) after pilocarpine inhalation was not found. Conclusion : In subjects with mild and moderate asthma, function of $M_2$ muscarinic receptors was normal, but there was a dysfunction of these receptors in subjects with severe asthma. ηlese results suggest that function of $M_2$ muscarinic receptors is different according to severity of asthma.

  • PDF