• Title/Summary/Keyword: BVD model

Search Result 5, Processing Time 0.02 seconds

Analysis of the Effects According to Changes in Impedance and Electrical Equivalent Circuit Modeling of a SONAR Transducer Considering Dual Resonance (이중 공진을 고려한 소나 트랜스듀서의 전기적 등가회로 모델링 및 임피던스 변동에 따른 효과 분석)

  • Mok, Hyung-Soo;Choi, Jae-Hyuk;Han, Soo-Hee;Park, Sang-Zoon;Kim, Sung-Joo;Heo, Jun-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.2
    • /
    • pp.144-151
    • /
    • 2015
  • The present study proposes a method for modeling a SONAR transducer with dual resonance. The Butterworth van-Dyke (BVD) model, a conventional SONAR transducer modeling method, can model only one resonance point. Hence, to address its disadvantage and to model the dual resonance, a dual resonance BVD model consisting of two serial BVD models is proposed. The two BVD models are connected in a series, and each simulate resonance at low frequency and high frequency, which allows the modeling of two resonance points. Eight elements compose the equivalent circuit by connecting the BVD models in a series, which is twice as great as that of the existing BVD model. The element value of the dual resonance BVD model is extracted by using the particle swarm optimization method. Analysis was also performed to identify the effects of changes in the value of elements that compose the equivalent circuit on the impedance characteristics of the equivalent circuit through simulation in which element values varied.

Thin Film Bulk Acoustic Resonator(FBAR) Bandpass Filter Design Technique Using Genetic Algorithm (유전자알고리즘을 이용한 FBAR RF 대역통과여파기 설계기법)

  • 이정흠;김형동
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.3
    • /
    • pp.10-17
    • /
    • 2003
  • In this paper, genetic algorithm (GA)-based Thin Film Bulk Acoustic Resonator (FBAR) RF filter design technique is proposed. Since the BVD(Butterworth-Van Dyke) lumped element model is valid only around the resonance, FBAR filter design technique based on BVD circuit has an approximate error. Instead of using BVD model, optimizing filter design method utilizes an analytical electrical impedance equation of FBAR. The geometry of FBAR such as thickness of the piezoelectric layer and area which significantly affect the filter response is optimized by GA. US-PCS Rx Bandpass filter obtained by the proposed technique shows a better response comparing with the typical and BVD-based filter.

Analysis of Appropriate Parameters for Piezoelectric Ceramic Utilization by Using BVD Model

  • Jeerapan, Chalermchai;Sriratana, Witsarut;Julsereewong, Prasit;Kummool, Sart
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2067-2070
    • /
    • 2005
  • This paper presents an approach to evaluate the appropriate parameters for Piezoelectric ceramic utilization by adopting Impedance Method. Butterworth Van Dyke model (BVD) is considered to use as an equivalent circuit of Piezoelectric ceramic in case of no load. The experimental results from this model will be compared with the results from a circular Piezoelectric ceramic with 4.8 cm. diameter and 3 mm. thickness. The Thickness Mode vibration measured by Impedance Analyzer model 4192A can be analyzed from 1Hz to 13MHz for calculating and analyzing parameters at resonance frequency and anti-resonance frequency. These parameters are evaluated to design the efficient circuit for Piezoelectric ceramic utilization to obtain the optimal efficiency.

  • PDF

A histomorphometric study of dental implants with different surface characteristics

  • Pak, Hyun-Soon;Yeo, In-Sung;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.4
    • /
    • pp.142-147
    • /
    • 2010
  • PURPOSE. One of the major keys to achieve successful osseointegration of the implant is its surface properties. The aim of this study was to investigate the bone response to dental implants with different surface characteristics using the rabbit tibia model. Tricalcium phosphate (TCP) coated, anodic oxidized and turned (control) surfaces were compared. MATERIALS AND METHODS. Seventy two implants were placed in the tibia of eighteen rabbits. Nine rabbits were sacrificed at 3 weeks of healing and the remaining nine were sacrificed at 6 weeks of healing. The bone-to-implant contact (BIC) and the bone volume density (BVD) were assessed by light microscope after 3 and 6 weeks of healing. RESULTS. Statistical analysis showed that no significant differences in the BIC and BVD were observed between the different implant surfaces and the control group at 3 weeks and 6 weeks of healing. Data also suggested that the BVD of all the surfaces showed significant difference at 3 and 6 weeks. CONCLUSION. The present study has showed that osseointegration occurred in all investigated types of surface-treated implants. In the current study all of the threads of the implants were observed to calculate BIC and BVD values (instead of choosing some of the threads from the bone cortex for example), which didn't make BIC or BVD percentage values better than in the control group, therefore the clinical relevance of these results remains to be shown.

Reference Values of Whole Blood Viscosity and Its Correlation with Hematology and Serum Chemistry in Beagle Dogs

  • Koh, Jun;Lee, Dong-bin;Lee, Dong Han;Kim, Nam Soo
    • Journal of Veterinary Clinics
    • /
    • v.35 no.3
    • /
    • pp.77-82
    • /
    • 2018
  • The aim of this study was to measure whole blood viscosity (WBV) and then to establish its reference values and identify correlation between WBV and hematology or serum chemistry in beagle. The experiment was made up of 82 healthy beagle dogs. Jugular vein blood samples (10 ml) were collected. WBV (cP) measured within 4 hours after collection by U-shaped scanning capillary-tube viscometer ($BVD-PRO1^{(R)}$) which is capable of measuring yield stress and viscosity of whole blood continuously over a wide range of shear rates from $1s^{-1}$ to $1000s^{-1}$ is new type of capillary tube viscometer and calculates viscosity using Casson fluid model. Measured values of WBV, Complete blood cell count, serum chemistry were analyzed by RM-ANOVA test. Mean diastolic and systolic WBV (cP) were $29.032{\pm}6.137$ and $4.528{\pm}0.865$. Bodyweight (BW), Red blood cell count (RBC), Hemoglobin (HGB), Hematocrit (HCT), Alkaline phosphatase (ALP), Cholestetol (CHOL), Total protein (TP), Globulin, Chloride (Cl), Fibrinogen, were statistically correlated with WBV over whole range of shear rates (p < 0.05). This study newly evaluated reference values of WBV by U-shaped viscometer in beagle. Correlation between WBV and BW, RBC, HGB, HCT, ALP, CHOL, TP, Globulin, Cl, Fibrinogen was presented.