• Title/Summary/Keyword: BSTFA

Search Result 19, Processing Time 0.023 seconds

GC/MS Analysis of Ethylene Glycol in the Contaminated Lubricant Oil Through Solvent Extraction Followed by Derivatization using Bistrimethylsilyltrifluoroacetamide (BSTFA) (엔진윤활유 중 Ethylene Glycol의 용제추출후 bistrimethylsilyltrifluoroacetamide(BSTFA)를 이용한 GC/MS 분석에 관한 연구)

  • Lee, Joon-Bae;Kwon, O-Seong;You, Jae-Hoon;Shon, Shungkun;Sung, Tae-Myung;Paeng, Ki-Jung
    • Tribology and Lubricants
    • /
    • v.28 no.6
    • /
    • pp.315-320
    • /
    • 2012
  • For proper functioning, general machines usually need lubricant oil as a cooling, cleaning, and sealing agent at points of mechanical contact. The quality of lubricant oil can deteriorate during operation owing to various causes such as high temperature, combustion products and extraneous impurities. In this study, a heavy load stopped during operation, and the oil was analyzed to check whether any impurities were added. Extraction using acetonitrile followed by reaction with BSTFA(bistrimethylsilyl trifluoroacetamide) showed that, trimethylsilylated ethylene glycol was present in the lubricant oil. To quantify the ethylene glycol in the oil, deuterium-substituted ethylene glycol, which acted as an internal standard, was added to the sample and then extracted with the solvent. Next, the extract was reacted with the derivatizing agent(BSTFA) and then analyzed with GC/MS. The detection limit of this method was found to be $0.5{\mu}g/g$ and the recovery of oil containing $20,000{\mu}g/g$ of ethylene glycol was measured to be 94.8%. A damaged O-ring and eroded cylinder liner were found during the overhaul, which implied the leakage of coolant containing ethylene glycol into the lubricating system. The erosion of the cylinder liner was assumed to be due to cavitation of the coolant in the cooling system.

Comparison of the Analytical Method for 3-Monochloropropane-l,2-diol in Food (식품 중 3-monochloropropane-1,2-diol의 분석법 비교 연구)

  • Yoo, Seung-Seok;Oh, Chang-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.360-365
    • /
    • 2007
  • The studies for the derivatization of 3-monochloropropane-1,2-diol (3-MCPD) were performed mainly as acylation with HFBI (heptafluorobutyrylimidazole), alkylation with PBA (phenylboric acid) and silylation with BSTFA (N,O-bis[trimethylsilyl]trifluoroacetamide). Also silylation with MTBSTFA(N-methyl-N-[tert.-butyldimethylsilyl] trifluoroacetamide) and acylation with MBTFA (N-Methyl-bis[trifluoro-acetamide]) were also considered. Except the TBDMS derivative of 3-MCPD, all the derivatives were detected well. The derivatives of 3-MCPD with HFBI, PBA and BSTFA showed below 10 ${\mu}g/kg$ which was sensitive enough to satisfy Korea maximum residue limit 0.3 mg/kg. Among the tested adsorbents, Extrelut20 and Florisil were evaluated as the proper adsorbents to eliminate the soy sauce matrix for 3-MCPD. Ethyl acetate was the most efficient eluent with good recovery rate. The desired surrogate compound and internal standard were 1,2-butanediol and 1,2-dibromo-3-chloropropane, respectively. The limit of detection for PB-MCPD and TMS-MCPD were 10.16 and 7.06 ${\mu}g/kg$ on GC/MSD, respectively. HFB-MCPD derivative showed the lowest detection limits 2.98 and 5.32 ${\mu}g/kg$ by GC/ECD and GC/MSD, respectively.

Determination of panthenol, cholecalciferol and tocopherol in cosmetic products by gas chromatography-mass spectrometry in SIM mode

  • Hye-Jin Jeong;Myo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.22 no.2
    • /
    • pp.153-160
    • /
    • 1996
  • A novel simple method to detect vitamins in cosmetic products by gas chromatography-mass spectrometry(GC-MS) has been developed. Three vitamins(panthenol, cholecalciferol and tocopherol) were used for this study. Vitamins were prepared by dissolving in tetrahydrofuran(THF), and silylated with bis-trimethylsilyltrifluoroacetamide-trichloromethylsilane(BSTFA). Silated vitamins were separated on a fuses-silica capillary column coated with DB-5. The identification of each vitamin was accomplished by retention time and mass spectrum library search with a computer, and the quantitation was made in the selected-ion monitoring(SIM) mode of GC-MS. SIM mode had given sensitivity to determine 50pg of panthenol, 285pg of cholecalciferol and 130pg of tocopherol. Linearity was maintained over the range 0.005-0.20% for each vitamin. Each cosmetic product(i.e. hair tonic and lotion) was found to contain amounts of the vitamins. This method was sensitive and gave 77.5-99.9% recovery of each vitamin from these cosmetic products. From these results, we concluded that silylation with BSTFA followed by GC-MS analysis allows the simple, covenient and exact determination of panthenol, cholecalciferol and tocopherol.

  • PDF

Thermodynamic Studies on the Adsorption of 4-Octylphenol on Carboxen by GC/MS Analysis (GC/MS 분석에 의한 4-Octylphenol의 Carboxen 흡착에 대한 열역학적 연구)

  • Lee, Joon-Bae;Park, Woo-Yong;Shon, Shungkun;Jung, Ji Eun;Jeong, Yong Ae;Gong, Bokyoung;Kim, Yu-Na;Kwon, O-Seong;Paeng, Ki Jung
    • Applied Chemistry for Engineering
    • /
    • v.29 no.3
    • /
    • pp.356-361
    • /
    • 2018
  • It is common to analyze volatile organic compound (VOC) or semi-VOC (SVOC) in a sample composed of a complex matrix consisting of multiple components such as bloods through a separation process. Adsorption is a physical phenomenon in which certain components accumulate on the surface of other phases. In order to overcome difficulties in the pretreatment process, an adsorption is frequently used. Solid phase microextraction (SPME) equipment with porous carbon carboxen (CAR) is an example of adsorption application. In this study, the adsorption of 4-octylphenol to carboxen was examined. To do so, the extraction efficiency for such solvents as dichloromethane ($CH_2Cl_2$, DCM), ethylacetate ($CH_3COOC_2H_5$, EA) and diethylether ($C_2H_5OC_2H_5$, $Et_2O$) was studied and also the derivatization reaction for 4-octylphenol with reagents of bistrimethylsilyltrifluoroacetamide (BSTFA), methylchloroformate (MCF) and pentafluorobenzylbromide (PFBBr) was compared. The combination of DCM and BSTFA showed good performance thus they were adopted for this study. Thermodynamic adsorption experiments showed that the adsorption process was endothermic and Freundlich isotherm equation was more suitable than Langmuir isotherm. It was also found that the adsorption followed a pseudo-$2^{nd}$ order kinetic model.

Determination of the PDE-5 Inhibitors and Their Analogues by GC-MS and TMS Derivatization

  • Pyo, Jae-Sung;Lee, Hee-Sang;Park, Yu-Jin;Jo, Ji-Yeong;Park, Yong-Hoon;Choe, Sang-Gil;Lee, Mi-Young;Lee, Jae-Sin
    • Mass Spectrometry Letters
    • /
    • v.3 no.1
    • /
    • pp.15-17
    • /
    • 2012
  • Eighteen of the PDE-5 inhibitors and their analogues were analyzed using GC-EI-MS. Fourteen of them could be identified by simple GC-MS method without derivatization, but hydroxyhongdenafil, hydroxyvardenafil, xanthoanthrafil and mirodenafil could not be identified without derivatization for the high polarity due to the presence of hydroxyl groups. N,O-bis(trimethylsilyl) trifluoroacetamide (BSTFA) and N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA), widely used trimethylsilyl (TMS) derivatizing reagents, were used to improve the sensitivity of the hydroxylated analogues. And the analytes could be identified by GC-MS after the derivatization.

Simultaneous Gas Chromatography-Mass Spectrometric Determination of Total and Individual Phthalic Esters Utilizing Alkaline Hydrolysis and Silyl Derivatization Technique

  • Kim, Min-Seon;Li, Dong-Hao;Shim, Won-Joon;Oh, Jae-Ryoung;Park, Jong-Man
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.432-438
    • /
    • 2007
  • Environmentally important phthalic esters have been analyzed by GC-MS in terms of individual phthalic esters or total phthalic esters directly or after derivatization. Derivatization improves the chromatographic characteristics of the highly polar phthalic esters. This study focused on the GC-MS determination of the total phthalic esters and the individual phthalic esters simultaneously. The phthalic esters were hydrolyzed to phthalate and corresponding alcohols in 1 M NaOH solution at 90 oC for 30 min followed by extraction with ethyl acetate after acidifcation. The phthalic acid and alcohols were simultaneously silyl derivatized using bis(trimethylsilyl)trifluoroacetamide (BSTFA) to their corresponding silyl ester and ethers in the mixture of 60% acetone and 40% ethyl acetate at room temperature within 30 min. Because of the high reactivity of BSTFA with the phthalic acid and alcohols effective silyl derivatization was possible simultaneously. GC-MS analysis of the silyl derivatives of phthalic acid and alcohols was performed. The total phthalic ester content was estimated from the analytical result of phthalic silyl ester, while the individual phthalic ester was quantified from the analytical results of alcoholic silyl ethers. This technique was applied to spiked tab water and real seawater samples from the Lake Shihwa in Korea. The results were checked against the results from the direct GC-MS analysis of the phthalic esters and reasonable recoveries with high sensitivity were achieved. The recoveries were higher than 75% with low relative standard deviation (below 10%).

울산지역 폐수 중 프탈레이트 에스테르 및 비스페놀 A(환경호르몬)의 GC/MS 분석

  • Han, Yeong-Ju;Park, Jin-Do;Lee, Hak-Seong
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2008.11a
    • /
    • pp.248-251
    • /
    • 2008
  • 일반적으로 phthalate esters의 전처리방법에는 액액추출법(liquid-liquid extraction), 고상추출법(Solid-phase Extraction, SPE), 고상미세추출법(Solid-phase micro extraction, SPME) 등의 분석방법이 있다. 그 중에서 본 연구에서는 SPE를 이용하여 간편하고 정확성이 높으며, 적은 양의 유기용제를 사용하여 전처리함으로써 2차적인 환경오염을 줄일 수 있다는 점에서 다른 전처리 방법보다 유용하다고 할 수 있다. 검출감도 측면에서 phthalate esters의 경우는 구조적으로 안정적인 편이나 페놀류의 경우 hydroxy group 때문에 GC/MS 분석시 유도체화 과정이 필수적인데 이번 연구에서 사용한 BSTFA/TMCS는 비교적 쉽고 빠르게 유도체 화할 수 있다는 이점이 있다. 더 많은 연구가 필요하겠지만 앞서서의 결과에서도 알 수 있듯이 전반적으로 검출한계가 0.05$\sim$0.5 $\mu$g/L 정도로 높고, 4-nonyl phenol을 제외하고 80% 이상의 양호한 회수율을 나타낸 것으로 미루어 보아 phthalate esters, phenols의 효율적인 동시분석이 가능함을 알 수 있다.

  • PDF

Methylation Methods on Identification of Phenolics in Chebulae Fructus (Chebulae Fructus중 페놀 물질 확인시의 Methylation법 비교)

  • 김정숙
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.4 no.1
    • /
    • pp.79-86
    • /
    • 1994
  • Food quality in food processing and storage were affected by the kinds of phenolics involved. To analyze phenolics of Chebulae Fructus by the way of GC-MSm methylation and trimethylsilyation(TMS) are necessary. The methods of methylation were dimethyl sulfate method and diazomethane method. so this study was undertaken to research the better methylation method before measuring GC-MS. But dimethyl sulfate method of methylation was not sufficient to analyze phenolics. So the phenolics of Chebulae Fructus were analyzed by the diazomethane methylation method and TMS with the pyridine, N-O-bis-trimethylsilyl-acetamide(BSTFA) and trimethylchlorosilane(TMCS). With the exception of pyrogallol and phloroglucinol in insoluble phenolics of Chebulae Fructus, the greater part of phenolics. analysis could be analyzed by GC-MS in company with diazomethane methylation method and TMS.

  • PDF

Chemometric A spects of Sugar Profiles in Fruit Juices Using HPLC and GC

  • 윤정현;김건;이동선
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.7
    • /
    • pp.695-702
    • /
    • 1997
  • The objective of this work is to determine the sugar profiles in commercial fruit juices, and to obtain chemometric characteristics. Sugar compositions of fruit juices were determined by HPLC-RID and GC-FID via methoxymation and trimethylsilylation with BSTFA. The appearance of multiple peaks in GC analysis for carbohydrates was disadvantageous as described in earlier literatures. Fructose, glucose, and sucrose were major carbohydrates in most fruit juices. Glucose/fructose ratios obtained by GC were lower than those by HPLC. Orange juices are similar to pineapple juices in the sugar profiles. However, grape juices are characterized by its lower or no detectable sucrose content. In addition, it was also found that unsweeten juices contained considerable level of sucrose. Chemometric technique such as principal components analysis was applied to provide an overview of the distinguishability of fruit juices based on HPLC or GC data. Principal components plot showed that different fruit juices grouped into distinct cluster. Principal components analysis was very useful in fruit juices industry for many aspects such as pattern recognition, detection of adulterants, and quality evaluation.

Determination of plasma ketone body following oximation-trimethylsily| derivatization using gas chromatography-mass spectrometry selected ion monitoring (혈장 중 케톤체의 옥심-TMS 유도체화 후 GC-MS/SIM을 이용한 분석)

  • Yoon, Hye-Ran
    • Analytical Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.49-55
    • /
    • 2016
  • A ketone body (acetoacetic acid, β-hydroxybutyric acid, and acetone) increases from blood or urine when bio-energy dependence pays more fatty acid than glucose. However, in case oxidation of fat is greater than the capacity of the citric acid cycle the fatty acid oxidation is made from acetoacetyl CoA to acetoacetate then, again form β-hydroxyburytic acid to acetone, the diffusion take place into the blood. Enzymes that oxidize ketone body in the brain and nerve tissue blood ketone dody is increased during prolonged fasting, brain used it as energy. In this study, we developed the rapid two step derivatization method for sensitive detection of the ketone body by GC-MS/SIM. The plasma was deproteinized and then the hydroxy and carboxyl groups of ketone body are subjected to extraction and drying then, keto-group were derivatized with hydoxylamine at 60℃ for 30 min for oximation. Then it was trimetyl-silylated with BSTFA at 80℃ for 30 min and analyzed using a GC-MS. The linear ranges were in between 0.001 μg/mL and 250 μg/mL for β-hydroxy butyrate, and acetoacetate. The method detection limits were below 0.1 pg over each target compound determined. The mean recoveries (%) of target compounds were ranged from 88.2 % to 92.3 % at 1 µg/mL, from 89.5 % to 94.8 % at 10 μg/mL, with RSD of 6.3-9.4 %. This method could be applied to quantification of ketone bodies which are seen in the keto-acidosis in children and adults from a variety of diseases that cause ketones in the blood and urine.