• Title/Summary/Keyword: BQ

Search Result 437, Processing Time 0.026 seconds

Evaluation of Radon Levels in Various Public-acess Buildings or Underground Facilities, and Their Temporal Variation in Underground Facilities (다중 이용 건물 또는 지하 실내 공간의 용도에 따른 라돈 오염도 비교와 지하 공간의 시간대별 라돈 농도 변화)

  • Choi, Im-Cho;Shin, Seung-Ho;Jo, Wan-Kuen
    • Environmental Analysis Health and Toxicology
    • /
    • v.24 no.3
    • /
    • pp.203-211
    • /
    • 2009
  • A lesser degree of research is available with respect to indoor radon characteristics associated with occupants' exposure. The present study evaluated the radon levels in several public-access buildings or underground facilities, and their temporal variation in underground facilities. Radon measurements were conducted in 2005 and 2006, utilizing a continuous radon detector. A solid alpha detector (RAD7) was utilized to measure indoor radon levels. The mean radon concentrations obtained from the building or facilities were in a descending order: platforms of Daegu subway line 2, 2005 (32 $Bq/m^3$), hot-air bathroom (14 $Bq/m^3$), basement of office building (14 $Bq/m^3$), underground parking garage (14 $Bq/m^3$), underground shop (12 $Bq/m^3$), nursery (10 $Bq/m^3$), platforms of Daegu subway line 2, 2006 (9.0 $Bq/m^3$), platforms of Daegu subway line 1, 2006 (8.9 $Bq/m^3$), supermarket (7.9 $Bq/m^3$), hospital (7.3 $Bq/m^3$), and second-floor of office building (5.7 $Bq/m^3$). In general, underground-level facilities exhibited higher radon levels as compared with ground-level facilities. It was suggested that ventilation is an important parameter regarding the indoor levels of a subway. There was a decreasing or increasing trend in hourly-radon levels in a subway, whereas no trend were observed in a basement of office building. In addition, the radon levels in the subway lines 1 and 2 varied according to the platforms. The radon levels in the present study were much lower than those of previous studies. The average annual effective dose (AED) of radiation from indoor radon exposure was estimated to be between 0.043 and 0.242 mSv/yr, depending on facility types. These AEDs were substantially lower than the worldwide average AED (2.4 mSv/yr).

BQ-123, $ET_{A}$ antagonist, decreases clinical sign and inflammatory region on EAE.

  • Kang, Bong-Su;Park, Young-Shim;In hoi Huh
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.191-191
    • /
    • 1996
  • BQ-123, a selective $ET_{A}$ receptor antagonist, reverses various responses induced by Endothelin-1 and it has been reported that BQ-123 ameliorates the cerebrovascular constriction, hypertension, and decrease of blood flow. Previously, we announced that the level of Endothelin-2 increase in the brain and spinal cord of EAE-induced lewis rat and showed the origin of ET-1 is activated macrophages. Intracisternal injection of $ET_{A}$ receptor antagonist, BQ-123(10nmol) was done for visualizing the role of endothelin-1 on the pathogenesis of EAE. BQ-123 apparently blocked the severity of clinical score of EAE and decreased the histologically observed inflammatory region. The blocking effect on the progression of EAE model following BQ-123, suggests that BQ-123 is a physiological antagonist in terms of development of the sign of multiple sclerosis.

  • PDF

대전지역 지열별 지하수중의 라돈 및 우라늄 분포 특성연구

  • Yun Yun-Yeon;Jo Su-Yeong;Lee Gil-Yong;Kim Yong-Je
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.300-303
    • /
    • 2005
  • 대전지역 화강암지대에 존재하는 75개 지하수를 5개 지역구에서 채취하였으며, 상ㅁ하반기 동안 2차례 시료를 채취하여 건기와 우기후의 라돈 및 우라늄 농도를 분석하였다. 5개 지역에 대한 라돈과 우라늄의 평균 농도는 유성구에서 270.9 Bq/L, $43.8{\mu}g/L$ 였으며, 동구의 경우 41.3 Bq/L, $4.9{\mu}g/L$, 대덕구는 131.8 Bq/L, $54.3{\mu}g/L$, 중구의 경우 44.0 Bq/L, $8.1{\mu}g/L$ 그리고 서구는 112.9 Bq/L, $0.4{\mu}g/L$ 이었다. 라돈과 우라늄의 함량은 건기가 우기후에 비해 대체로 높게 나타났으며 건기시의 평균값은 라돈은 $253{\pm}14\;Bq/L$ 우라늄은 $63{\mu}g/L$ 이었으며, 우기시는 $195{\pm}11\;Bq/L,\;45.4{\mu}g/L$ 이었다.

  • PDF

Gross-β Level in Dental Ceramic Materials (치과용 세라믹 재료의 전β 방사능 준위)

  • Kim, Sung-Hwan;Jeong, Hyun-Ja
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4819-4825
    • /
    • 2010
  • In all of dental ceramics, these materials contained the radio-isotopes with natural abundance ratio. After dental treatment, remained dental ceramics in the oral cavity is caused for human internal dose. In this study, the gross beta activity levels were measured in dental materials including 22 dental ceramics, 1 resin, and 2 cements for estimation of human internal dose. In dental ceramic samples, the obtained results showed that the gross beta activity level varied between 1.317 ~ 2.935 Bq/g and the gross beta activity level was 2.379 Bq/g. And the same level for dentine, opacious dentine, translucent and enamel were 2.479 Bq/g, 2.491 Bq/g, 2.470 Bq/g and 2.069 Bq/g, respectively. The gross beta activity level of temporary resin and cements were negligible, compare to the same level of dental ceramics. The high gross beta activity level observed in opacious dentine code OD-A4 is 2.935 Bq/g thus mainly ascribable to 40K. The reduction of the radiation level of natural radio-isotopes and the improvement of the dental ceramic materials should be required for internal dose reduction.

Analysis of Seasonal Airborne Radon Concentration Characteristics in Public-Use Facilities

  • Young-Do KIM;Woo-Taeg KWON
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.6 no.2
    • /
    • pp.1-7
    • /
    • 2023
  • Purpose: The purpose of this study is to investigate the characteristics of airborne radon concentration by season in public-use facilities in South Korea. Research design, data and methodology: The data is provided by the public data portal, and public-use facilities nationwide where radon in the air is measured are specialized sanatorium for senior citizens, libraries, childcare facilities, postpartum care centers, medical institutions, funeral halls, underground shopping malls, and underground subway stations. Results: The facility with the highest radon concentration in public-use facilities was childcare facilities with an average of 50.2 ± 21.7 Bq/m3, while the average of medical institutions was the lowest at 24.8 ± 5.7 Bq/m3. The season with the largest difference in average radon concentration between childcare facilities and medical institutions was in the order of fall (28.6 Bq/m3), followed by winter (28.1 Bq/m3), spring (23.0 Bq/m3), and summer (22.0 Bq/m3). Conclusions: The main concentration levels of each public-use facility shown in this study are all below domestic and international standards, but there is a significant concentration difference between facilities. By season, winter showed the highest average concentration (40.6 ± 21.3 Bq/m3) and summer showed the lowest average concentration (23.8 ± 14.0 Bq/m3).

Radiochemical Analysis of Filters Used During the Decommissioning of Research Reactors for Disposal

  • Kyungwon Suh;Jung Bo Yoo;Kwang-Soon Choi;Gi Yong Kim;Simon Oh;Kanghyun Yoo;Kwang Eun Lee;Shinkyoung Lee;Young Sang Lee;Hyeju Lee;Junhyuck Kim;Kyunghun Jung;Sora Choi;Tae-Hong Park
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.4
    • /
    • pp.489-500
    • /
    • 2022
  • The decommissioning of nuclear facilities produces various types of radiologically contaminated waste. In addition, dismantlement activities, including cutting, packing, and clean-up at the facility site, result in secondary radioactive waste such as filters, resin, plastic, and clothing. Determining of the radionuclide content of this waste is an important step for the determination of a suitable management strategy including classification and disposal. In this work, we radiochemically characterized the radionuclide activities of filters used during the decommissioning of Korea Research Reactors (KRRs) 1 and 2. The results indicate that the filter samples contained mainly 3H (500-3,600 Bq·g-1), 14C (7.5-29 Bq·g-1), 55Fe (1.1- 7.1 Bq·g-1), 59Ni (0.60-1.0 Bq·g-1), 60Co (0.74-70 Bq·g-1), 63Ni (0.60-94 Bq·g-1), 90Sr (0.25-5.0 Bq·g-1), 137Cs (0.64-8.7 Bq·g-1), and 152Eu (0.19-2.9) Bq·g-1. In addition, the gross alpha radioactivity of the samples was measured to be between 0.32-1.1 Bq·g-1. The radionuclide concentrations were below the concentration limit stated in the low- and intermediatelevel waste acceptance criteria of the Nuclear Safety and Security Commission, and used for the disposal of the KRRs waste drums to a repository site.

Tritium Concentrations of Tritiated Water Vapor and Tritiated Hydrogen in the Atmosphere in Taejon (대전지역 대기중 수증기상태 (HTO) 및 가스상태 (HT) 삼중수소의 농도)

  • Kim, C.K.;Han, M.J.;Kim, K.H.
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.97-101
    • /
    • 1997
  • During the period of March 1995 to December 1995, tritium concentrations of tritiated water vapor (HTO) and tritiated hydrogen (HT) in the atmosphere in Taejon were measured to evaluate present background levels of tritium in the atmosphere. Air samples were collected continuously for three weeks with a sampling system for tritium in the atmosphere and were analyzed by a liquid scintillation counting system. The range of the atmospheric HTO concentrations was 3.2-36 mBq $m^{-3}$ with a mean value of 16.2 mBq $m^{-3}$. The atmospheric HTO concentrations were the highest in summer and the lowest in winter. This trend was similar to the variation of atmospheric absolute humidity. The specific activities of tritium in atmospheric water vapor in Taejon ranged from 0.62 Bq $L^{-1}$ to 3.82 Bq $L^{-1}$ with a mean value of 2.04 Bq $L^{-1}$. The atmospheric HT concentrations were in the range of 35.7 mBq $m^{-3}$ to 48.9 mBq $m^{-3}$ with a mean value of 41.1 mBq $m^{-3}$.

  • PDF

Radon Concentrations in Groundwater of the Goesan Area, Korea (괴산지역 지하수의 라돈 함량)

  • Cho, Byong-Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.5
    • /
    • pp.63-70
    • /
    • 2017
  • Radon concentrations were measured in 250 groundwater samples collected from the Goesan area where uraniferous black slate and granites abundantly occur in the formations. The measured radon levels ranged from 0.90 to 7,218.7 Bq/L with the median value of 54.3 Bq/L, similar to the value measured in the nationwide survey in 4,853 wells (52.1 Bq/L). The median value was highest in the Cretaceous granite area (390.0 Bq/L) while it was as low as 20.0~58.8 Bq/L in the Ogcheon meta-sedimentary rock areas. About 23.6% of the total samples exceeded the WHO guideline value of 100 Bq/L established in 2011. The exceeding rate was 69.0, 39.4, and 7.0~13.7% in the Cretaceous granite area, Jurassic granite area, and Ogcheon meta-sedimentary rock areas, respectively.

Electrochemical Degradation of Benzoquinone in a Flow through Cell with Carbon Fibers

  • Yoon, Jang-Hee;Yang, Jee-Eun;Shim, Yoon-Bo;Won, Mi-Sook
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.403-407
    • /
    • 2007
  • The anodic degradation of benzoquinone(BQ), a model compound for wastewater treatment was carried out using a home-made flow-through electrochemical cell with carbon fibers. To optimize the controlled current electrolysis condition of an aqueous BQ solution, the experimental variables affecting the degradation of BQ, such as the applying current, pH, reaction time, and flow rate of the BQ solution were examined. The degradation products of the oxidation reaction were identified by High Performance Liquid Chromatography and Inductively Coupled Plasma Atomic Emission Spectrometer. Low molecular weight aliphatic acids, and CO2 were the major products in this experiment. The removal efficiency of BQ from the solution increased with the applying current and time. 99.23% of 1.0 × 10-2 M BQ was degraded to aliphatic acids and CO2 when the applying current is 175 mA in a 12 hr electrolysis.

An Analysis on the Gaseous Radioactive Waste Occurrence Present Condition in HANARO (하나로에서 기체 방사성 폐기물 발생 현황 분석)

  • Choi, Ho-Yeong;Hwang, Seung-Ryeol;Kang, Tae-Jin;Lee, Mun
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.556-561
    • /
    • 2003
  • The quantity of the gaseous radioactive waste generated from HANARO operation for the years from 1996 to 2002 has been investigated. The amounts of Ar-41, H-3 and I-131 exhausted to the environment were 6.33E13 Bq, 5.10E12 Bq and 3.26EB Bq, respectively.

  • PDF