• Title/Summary/Keyword: BPF noise

Search Result 98, Processing Time 0.025 seconds

Development of Low-Noise Cooling Fan Using Uneven Fan Blade Spacing (비등간격 블레이드를 이용한 저소음 쿨링팬 개발)

  • Lee, Jeong-Han;Nam, Kyung-Ook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1109-1114
    • /
    • 2007
  • When unifying the functions of widely used two-fan, engine cooling system into a single unit, the noise and power issues must be addressed. The noise problem due to the increased fan radius is a serious matter especially as the cabin noise becomes quieter for sedans. Of the fan noise components, discrete noise at BPF's (Blade Passing Frequency) seriously degrades cabin sound quality. Unevenly spaced fan is developed to reduce the tones. The fan blades are spaced such that the center of mass is placed exactly on the fan axis to minimize fan vibration. The resulting fan noise is $3{\sim}11$ dBA quieter in discrete noise level than the even bladed fan.

  • PDF

A Study on the Noise Reduction of the Engine cooling Fan used an Express Bus (고속 버스용 엔진 냉각 팬의 저소음화 연구)

  • Oh, Jae-Eung;Sim, Hyoun-Jin;Lee, Jung-Youn
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.279-284
    • /
    • 2002
  • In this study, it has been developed the program for predicting the noise spectrum of axial flow fan. The radiated acoustic pressure is expressed the discrete frequency noise peaks at BPF(Blade passage frequency) and its harmonics by Wu's method and the line spectrum at the broad band by Wright's method. And this paper presents the characteristics of a fan noise due to modify the design parameters. Accordingly, it is obtained the design parameter values for noise reduction of fan.

  • PDF

A Study on the Reduction of Discrete Frequency Tones of a Cross-Flow Fan of Air-Conditioners -Studies on the Random Distribution of Fan Blades and the Skewed Stabilizers- (에어컨 용 횡단류 홴의 특정 주파수 소음 성분의 저감 대책에 관한 연구 -날개의 랜덤 배열과 경사진 스태빌라이저에 대한 연구-)

  • 구형모
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.870-878
    • /
    • 1998
  • The cross-flow fan which constitutes a fan-duct system with a stabilizer and a scroll casing is widely used in many air-ventilating and air-conditioning devices. Its ooperating points of high efficiency and loading conditions frequently induce a annoying sharp tonal component of discrete frequency on the noise spectrum, which is open called as a BPF(Blade-Passing-Frequency) noise and degrades the sound quality of the devices. this BPF tone has been one of the defects of the cross-flow fan. This study proposes two methods in order to reduce this tonal noise component, which are the random distributions of the fan blades and the skewed shapes of the stabilizer. The proposed methods are verified by a simple analytical model and are applied in manufacturing the cross-flow fan and the stabilizer samples. Some experiments are carried out to verify the reduction capability of BPF tones of above two schemes and the experimental results are analyzed. The comparison between two method is also carried out.

  • PDF

Numerical analysis on the flow noise characteristics of 300W Savonius-type vertical-axis wind turbines (300W급 Savonius 형 수직축 풍력발전기의 유동소음특성에 관한 수치적 연구)

  • Kim, Sanghyoen;Lee, Gwangse;Cheong, Cheolung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.725-730
    • /
    • 2012
  • In this paper, flow noise characteristics of Savonius-type vertical-axis wind turbines are numerically investigated using hybrid CAA techniques. High frequency harmonics as well as BPF components are identified in the predicted noise spectra from a Savonius wind turbine. As the BPF components belong to infrasound, the higher harmonic components affects human response dominantly. Further analysis is performed to investigate the reason causing the higher frequency harmonic noise by changing operational conditions of a Savonius wind turbine. Based on this result, it is revealed that the frequency of higher harmonic components is determined by the radius of blades and angular velocity of Savonius wind turbine.

  • PDF

Aeroacoustics Analysis and Noise Reduction of Dual Type Combined Fan using Lattice-Boltzmann Method (Lattice-Boltzmann Method를 이용한 이중구조팬의 공력소음 해석 및 저감)

  • Kim, Wootaek;Ryu, Minhyung;Kim, Jinwook;Ho, Sunghwan;Cho, Leesang;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.5
    • /
    • pp.381-390
    • /
    • 2016
  • In this study, aeroacoustic characteristics of combined fan are investigated and noise was reduced by applying Serrated Trailing Edge which is known as the method to reduce fan noises. Unsteady CFD (Computational Fluid Dynamics) analysis was carried out using Lattice Boltzmann Method(LBM) to figure out the combined fan's aeroacoustics and experimental results was used to verify simulation results. Results show that different BPFs are generated at the each inner fan and outer fan on the different frequency while Blade Passing Frequency(BPF) of general fans is constant on the entire frequency range. Boundary vortex and vortex shedding are suppressed or dispersed by applying the Serrated Trailing Edge to the inner fan. Furthermore, broadband noise and fan's torque are reduced.

A Study on the Flow Characteristics and Noise Predictions around the Shroud Fan using the Aero-acoustic Noise Model (공력소음 모델을 이용한 슈라우드 팬 주위의 유동특성 및 소음예측에 관한 연구)

  • Mo, Jang-Oh;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.3
    • /
    • pp.19-25
    • /
    • 2009
  • InThe purpose of this work is to analyze the flow characteristics and aerodynamic noise generated from a shroud fan at a constant 2,100 rpm using LES and FW-H noise model provided in the commercial code, FLUENT. Velocity distributions around the shroud fan obtained by using FLUENT code show good agreement with experimental results. The sound pressure level is decreased by about 6 dB as the distance from the fan increases twice. The directivity at 1st BPF shows a tendency of increasing SPL toward the axis of rotation.

Design of Unequally-Spaced Blade Arrangement for Tonal Noise Reduction (순음성 소음의 분산을 위한 부등간격 블레이드 설계 연구)

  • Kim, Wan-Gi;Yun, Jong-Hak;Han, Seong-Su;Jeon, Se-Jong;Seong, Hyeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.4 s.175
    • /
    • pp.1047-1054
    • /
    • 2000
  • A numerical simulation was made to delineate the re-distribution of tonal noise generated from the equally-spaced blade passing frequency (BPF). A pressure-wave model was employed to analyze the tonal noise. An optimal solution for diversifying the tonal peak noise was obtained by rearranging the unequally-spaced blade angles. This was based on the fact that the noise energy is transferred from BPF to the neighboring frequency band. A limit condition for the minimum blade angle spacing was imposed. The unbalancing problem was also considered to avoid the weight bias.

Analysis of Discrete Noise Characteristics for the Cross Flow Fan with Uniform/Random hitch Blades (횡류홴 등/부등피치 블레이드의 이산소음 특성 분석)

  • Cho Yong;Kim Jong-Jin;Moon Young J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.141-148
    • /
    • 2000
  • The discrete noise of the cross-flow fan with uniform/random pitch blades is predicted by computational methods. With the time dependent surface pressure data obtained by solving the Wavier-Stokes equation, the acoustic pressure is calculated by the Ffowcs Williams-Hawkings equation. The positions of the blade noise source are identified through investigation of the acoustic pressure history induced by one blade, and it is confirmed that the dominant noise source is near the stabilizer. Since the acoustic pressure of the random pitch fan fluctuates according to blade passing, the dominant BPF noise for the uniform pitch fan is modified into some reduced discrete noises which have a 50Hz difference from BPF.

  • PDF

A Study on the Identification of Aeroacoustic Noise and Noise Reduction for a Vacuum Cleaner (청소기의 공력소음 특성 파악 및 저소음화에 관한 연구)

  • 전완호;백승조;김창준
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.6
    • /
    • pp.460-466
    • /
    • 2003
  • The aeroacoustic characteristics and noise reduction method of a centrifugal fan for a bagless vacuum cleaner were studied. The major noise source of vacuum cleaner is the centrifugal fan. The impeller of the fan rotates over 30000 rpm and generates very high-level piercing noise. It was found that the dominant noise source of the fan is generated from the aerodynamic interaction between the highly rotating impeller and stationary diffuser. In order to reduce the high tonal sound generated from the aerodynamic interaction between the impeller and diffuser, tapered impeller was carefully designed and tested. The trailing edge of the tapered impeller was inclined and this reduces the flow interactions between the rotating impeller and the stationary diffuser because of some phase shift. The static efficiency of the new impeller is slightly lower than the conventional one. The overall SPL is reduced about 3.6 dBA. The SPL of blade passing frequency(BPF) is reduced about 6 dBA and the $2^{nd}$ BPF is reduced about 20 dBA. The vacuum cleaner with the tapered impeller has lower noise level than that of the previous impeller and the strong tonal sound was dramatically reduced.

Design for Frequency Tripler Using Novel Bandpass Filter with Low Insertion Loss (낮은 삽입손실을 갖는 새로운 대역통과 필터를 이용한 주파수 3체배기 설계)

  • Min, Jun-Ki;Cho, Seung-Yong;Kim, Hyun-Jin;Kim, Yong-Hwan;Lee, Kyoung-Hak;Kim, Dae-Hee;Yun, Ho-Seok;Hong, Ui-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.10A
    • /
    • pp.1031-1036
    • /
    • 2006
  • This paper proposes a novel BPF structure with less insertion loss and small size instead of the existing coupled line BPF for the output of the tripler using APDP (Anti-Parallel Diode Pair). This proposed BPF consists of the interdigital capacitor and spiral open stub. The proposed BPF has the insertion loss of less than 0.7dB within the band $(16.41{\sim}19.23GHz)$. The conversion loss of the tripler is about $16.6{\sim}18.5dB$ $(flatness<{\pm}1dB)$ at $5.72{\sim}6.28GHz$ of fundamental frequency. Its fundamental frequency and the fifth harmonic suppression characteristic at 6GHz are -32.16dBc and -44.6dBc, respectively And its phase noise attenuation characteristic is about 9.5dB at 100kHz.