• Title/Summary/Keyword: BOK-WIRE

Search Result 74, Processing Time 0.024 seconds

The Roadblocks and Chances of Component-Based Development Business in Korea SI Industry: a Case of BOK-WIRE System (한국 SI산업에서 CBD사업의 장애 요인과 발전 가능성: 한은 금융망 시스템 구축 사례)

  • Kim, Kang-Suk
    • Journal of Information Technology Services
    • /
    • v.3 no.2
    • /
    • pp.105-118
    • /
    • 2004
  • Since Component-Based Development, or CBD, struck Korea SI industry a heavy blow several years ago, many major SI companies in Korea have implemented the CBD practices in real world, leveraging supports from the government and academic world. The result, however, falls short of their expectations. The major reason is that they have mainly focused on CBD processes and technical issues around it, although it is necessary as well to deal with other non-technical issues in order to make business values from CBD. This paper begins with reminding us what CBD tries to achieve indeed in terms of software development processes, then recognizes what we have achieved so far introducing a recent CBD project case, BOK-WIRE system. Thereafter, it reveals the chances that SI companies must take in order to make their CBD efforts succeed, pointing out what are the roadblocks really.

Korea's countermeasures based on a Comparison of the policy of large-value funds payment system between Korea and the US (한·미 거액결제시스템 정책비교로 본 우리나라의 대응방안)

  • Jeong, Boon-Do;Hong, Mi-Seon
    • Korea Trade Review
    • /
    • v.44 no.3
    • /
    • pp.191-202
    • /
    • 2019
  • Despite innovative efforts to accommodate changes in the payment environment, the new types of settlement risks that are emerging require preemptive and proactive responses. Therefore, Korea should complement and develop large-value funds payment system operation and risk management policies by introducing international standards and linking with advanced financial institutions. This study examines the major issues such as the development process and characteristics of the large-value funds payment system of the two countries, the operation policy of the central bank, and the risk management policy by comparing the US Fedwire with the Korea Bok-Wire+. In addition, policy implications are suggested for efficient operation and development of Bok-Wire+.

Evaluation on the Efficiency of Cored Wire Feeding in Addition of Alloying Elements into Cu Melt (코어드 와이어 피딩에 의한 Cu 용탕에의 합금 첨가 시 효율 평가)

  • Kang, Bok-Hyun;Kim, Ki-Young
    • Journal of Korea Foundry Society
    • /
    • v.33 no.6
    • /
    • pp.248-253
    • /
    • 2013
  • To add alloying elements into a pure copper melt, the wire-feeding efficiency of cored (alloy containing) wire was evaluated using a commercial, computational fluid-dynamics program. The model design was based on an industrial-scale production line. The variables calculated included wire feed rate, melt temperature, wire diameter, melt flow rate and wire temperature. Efficiency was evaluated after a series of calculations based on the penetration depth of the alloy-wire into the molten copper bath. Of the five variables investigated, the wire feed rate and wire diameter were the most influential factors affecting the feeding efficiency of the cored-wire.

The Effectiveness due to fixed position change of fault protective wire on catenary system (전차선로에서 보호선 설치 위치변경에 따른 효과 검토)

  • Ryoo, Hyang-Bok;Ahn, Young-Hoon;Hyun, Chung-Il;Kang, Seung-Wook
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1456-1459
    • /
    • 2007
  • Protective equipments have a very important protection role in power accident on catenary line. These equipments are installed on electrical pole. The poles have complicated with many bands(moveable bracket, branch wire anchor, shield wire, etc). So we have improved bands and installed bands on pole to test technical condition. The Result has showed effectiveness due to fixed position change of fault protective wire and to improve band shape. For example, reduction of band made cost, simplification of installing, correct position of protective wire and shield wire.

  • PDF

Technique of Maximum Span Length Calculation for 350km/h High Speed Catenary System (최고운행속도 350km/h급 전차선로 최대경간길이 계산 기법)

  • Chang, Sang-Hoon;Lee, Ki-Won;Ryoo, Hyang-Bok
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.924-931
    • /
    • 2011
  • This paper deal with maximum span calculation technique for 350km/h high speed catenary system. Considers a geometric interaction, possible maximum span length is between two pole. Wind condition and the train current collector is moving even to being pantograph does not escape while operating. Uses like this justice and possible maximum span length is follow next condition. (i) Operating range of pantograph fan head, (ii) The wind velocity which assumes from system, (iii) Width in pantograph from operation height moving, (iv) Type of processing Catenary system, specially tensile strength of overhead contact wire and messenger wire etc. When accurately calculates the maximum permission span, the dropper between of overhead contact wire and messenger wire and must consider the correlation.

  • PDF

Guide wire fracture during percutaneous coronary intervention (경피적 관상동맥 확장 성형술 도중 우관상동맥 뒤가쪽가지에서 발생한 유도철사 부러짐)

  • Kim, Hak Ro;Yim, Tae Hoon;Kim, Byung Chul;Lee, Ho Jun;Oh, Hong Geun;Ju, Hyun Sik;Kim, Tae Jin;Kim, Young Bok
    • Journal of Yeungnam Medical Science
    • /
    • v.33 no.1
    • /
    • pp.52-55
    • /
    • 2016
  • Guide wire fracture during percutaneous coronary intervention (PCI) is rare. It can cause fatal complications such as thrombus formation, embolization, and perforation. Guide wire fracture could occur during intervention for severely calcified stenotic lesions, and rarely from distal small branches of stenotic lesions. There are several methods for its management depending on the material character, position, length of the remnant, and the patient's condition. If percutaneous retrieval was not achieved, the surgical procedure should be considered for prevention of potential risks, although the remnant guide wire does not usually cause complications. We experienced a patient with a guide wire fracture during PCI, and managed to prevent its complications through surgical removal of the remnant wire. We report this case here.

Repetitive Over-current Characteristics of YBCO Coated Conductor for Applying to SFCL (초전도한류기에 적용하는 YBCO 박막형 선재의 반복적 과전류 특성)

  • Ahn, Min-Cheol;Seok, Bok-Yeol;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.3
    • /
    • pp.26-31
    • /
    • 2007
  • In recent years. YBCO coated conductor (CC) called as second generation HTS (high temperature superconducting) wire has been developed as a suitable material for resistive superconducting fault current limiter (SFCL). For designing the SFCL. the required length of superconducting wire is inverse proportional to the maximum temperature reached when a fault occurs. Since the required length strongly affects a manufacturing cost, it is the most important parameter to determine the maximum temperature reached. It is necessary to observe the repetitive over-current characteristics of HTS wire. This paper attempts to measure the variation of critical current of YBCO CC after repetitive over-current pulse. No degradation of the critical current of CC sample was observed by applying 100 times over-current pulse which makes temperature above 400 K after 100ms. This study can be useful in designing optimally resistive SFCL employing YBCO CC. The maximum permissible temperature can be set to 400K. so wire length could be reduced by 30% compared in case of 300K-criterion.

Microstructure and Hardness of 1st layer with Crystallographic Orientation of Solidification Structure in Multipass Weld using High Mn-Ni Flux Cored Wire (고(<24%)Mn 플럭스코어드와이어를 사용한 다층 용접 시 초층 응고조직의 결정면방위에 따른 미세조직과 경도)

  • Han, Il-Wook;Eom, Jung-Bok;Yun, Joong-Gil;Lee, Bong-Geun;Kang, Chung-Yun
    • Journal of Welding and Joining
    • /
    • v.34 no.5
    • /
    • pp.77-82
    • /
    • 2016
  • In this study, Microstructure and hardness of 1st layer with crystallographic orientation were investigated about solidification structure in multipass weld using high Mn-Ni flux cored wire. Microstructure of solidification consisted of austenite matrix and a little ${\varepsilon}-phase$ in grain boundaries. Orientation of grains was usually (001), (101), (111). According to crystallographic orientation, morphology of primary dendrite was different. The depletion of Fe and the segregation of Mn, C, Ni, Si, Cu, Cr, O were found along the grain boundaries. The area of segregation was wide with an order of (001), (101), (111) grains. And hardness of grains with crystallographic orientation increased with an order of (001), (101), (111) grains because of the segregation along dendrite boundary.