• 제목/요약/키워드: BOD-SS loading

검색결과 95건 처리시간 0.018초

주성분분석에 의한 $A_{2}O$공법의 처리성 평가 (Treatability Evaluation of $A_{2}O$ System by Principal Component Analysis)

  • 김복현;이재형;이수환;윤조희
    • 한국환경보건학회지
    • /
    • 제18권2호
    • /
    • pp.67-74
    • /
    • 1992
  • The lab-scale biological A$_{2}$O system was applied from treating piggery wastewater highly polluted organic material which nitrogen and phosphorous are much contained relatively in conversion with other wastewater. The objective of this study was to investigate the effect of variance parameters on the treatability of this system according to operation conditions. An obtained experimental data were analysed by using principal component analysis (PCA) method. The results are summarized as follows: 1. From Varimax rotated factor loading in raw wastewater, variance of factor 1 was 36.8% and cumulative percentage of variance from factor 1 to factor 4 was 81.5% and of these was related to BOD, TKN and BOD loading. 2. In anaerobic process, variance of factor 1 was 33.5% and cumulative percentage of variance from factor I to factor 4 was 81.8% and of these was related to PO$_{4}$-P, BOD, DO and Temperature. 3. In anoxic process, variance of factor 1 was 30.1% and cumulative percentage of variance from factor i to factor 4 was 84.3% and of these was related to pH, DO, TKN and temperature. 4. In aerobic process, variance of factor 1 was 43.8% and cumulative percentage of variance from factor 1 to factor 4 was 81.5% and of these was highly related to DO, PO$_{4}$-P and BOD. 5. It was better to be operated below 0.30 kg/kg$\cdot$day F/M ratio to keep over 90% of BOD and SS, 80% of TKN, and 60% of PO$_{4}$-P in treatment efficiencies. 6. Treatment efficiencies was over 93% of BOD and SS, 81% of TKN and 60% of PO$_{4}$-P at over 20$^{\circ}$C, respectively.

  • PDF

강우시 저농도 고수리부하가 회분식 반응조 제거효율에 미치는 영향 (Effects of Inflow Fluctuation on the Removal Efficiency in Low Strength Sewage Treatment using Sequencing Batch Reactor Process during Rainfall)

  • 어성욱;김건하;손봉호
    • 한국물환경학회지
    • /
    • 제22권1호
    • /
    • pp.91-96
    • /
    • 2006
  • Many small scale Sewage Treatment Plants (STPs) are currently being constructed at many rural areas. The STPs in rural area suffer from low concentration and large inflow quantity fluctuation during wet weather mainly due to illicit combined sewer system. Sequencing Batch Reactor (SBR) is a process effectively coping with these obstacles. The main objective of this study was to evaluate SBR with high hydraulic loading and low inflow concentration. The operating conditions tested were: organic loading rate = $0.17-0.42KgBOD/m^3/d$, hydraulic loadings = $12.1-61.5m^3/m^2/d$, average MLSS concentration = 2500 mg/L, F/M ratio = 0.026-0.17 KgBOD/Kg MLSS, HRT = 9-12 hr HRT, and SRT = 5.6-33.6 days. Organic loading rate on SBR did not impact significantly on BOD and SS removal efficiencies. To increase treatment efficiencies, low hydraulic loading rate with low concentration was required. The results suggested that low influent concentration with high inflow rates during wet weather requires extended time for settling.

유량변동에 따른 소양강유역 수질의 통계학적 해석 (A Stochastic Analysis of the Water Quality on the Basin of Soyang River with Discharge Variation)

  • 최한규;백경원;최용묵;최진우
    • 산업기술연구
    • /
    • 제21권B호
    • /
    • pp.233-240
    • /
    • 2001
  • This research was conducted with the aim of efficiently managing large scale of rivers such like Songyang-river through predicting water quality change with analyzing the characteristics of the flowing in nutrients and pollutants. The main result will be used as basic data for effectively operating reservoirs through controling water quality and quantity. The relationship between quantity of flow and water quality was analyzed and pollution loading into the basin was estimated. Three areas of Soyang-river upstream and one area of Suip-cheon in Yanggu-gun were selected as research sites. Flow and water quality were measured simultaneously. The relation between quantity of discharge and pollution concentration and between quantity of discharge and pollution loading were analyzed by statistical method, respectively. We provided a rating curve through measuring quantity of discharge(collecting quantity of discharge) and pollutograph and pollution loading curve through water quality data. Also, we analyzed the correlation between quantity of discharge per unit area and pollution loading per unit area in each basin. As resurt of this research, Buk-cheon spot revealed an excellent first grade water quality for the items including $BOD_5$, DO, and SS. The correlation coefficient between Buk-cheon spot's quantity of discharge and pollution loading was 0.896~0.996, showing the validity of analysis applying correlation curve formula of quantity of discharge and pollution loading in the same spot. Also, pollution loading per unit area of the items including $BOD_5$, COD, DO, SS, T-N, T-P increased as the area of basins get increased following the sequence of Buk-cheon, Suip-cheon, Naelin-cheon spots.

  • PDF

비점오염원 처리를 위한 동복천 인공습지의 시기별 및 부하량별 수처리 효율 평가 (Evaluation of Wastewater Treatment Efficiency in Dongbokcheon Constructed Wetlands for Treating Non-point Source Pollution at Different Treatment Time and Wastewater Loading)

  • 이상규;서동철;강세원;최익원;임병진;박종환;김갑순;이준배;허종수;조주식
    • 한국토양비료학회지
    • /
    • 제44권5호
    • /
    • pp.929-936
    • /
    • 2011
  • 비점오염원 저감을 위해 설치된 동복천 인공습지의 효율적인 관리 방안을 제시하기 위하여, 동복천 인공습지의 시기별 및 부하량별 수처리 효율평가를 실시하였다. 유입수의 BOD, SS, T-N 및 T-P 함량은 각각 $0.85{\sim}3.14mg\;L^{-1}$, $3.33{\sim}9.70mg\;L^{-1}$, $0.64{\sim}5.33mg\;L^{-1}$$0.03{\sim}0.10mg\;L^{-1}$ 범위이었으며, 연평균 처리효율은 BOD, SS, T-N 및 T-P가 각각 34%, 5%, 31% 및 13%로서 BOD와 T-N의 처리효율이 SS와 T-P 처리효율 보다 높았다. 인공습지 구성시스템별 오염물질 부하량에 따른 오염물질 처리량은 BOD에서 침강지 > 습지조 > 침전지, SS에서 침전지 > 습지조 > 침강지, T-N에서 침전지 > 침강지 > 습지조 순이었으며, T-P의 경우에는 침전지와 침강지에서는 큰 차이가 없었으나 습지조에서는 다른 시스템에 비해 높은 효율을 보였다.

우오수분리벽을 이용한 합류식 하수관거의 오염물질 제어효과 (Pollutant Control using the Separation Wall between Stormwater and Sewage in a Combined Sewer System)

  • 이광춘;최봉철;임봉수
    • 상하수도학회지
    • /
    • 제18권4호
    • /
    • pp.461-469
    • /
    • 2004
  • This research is to determine the stormwater effects on sewer concentrations by measuring and comparing the flow and pollutant concentrations during dry and rainy periods in the existing BOX type combined sewer pipes. The monitoring was carried out in two sites, which are the Daesachen outfall having PE separation wall in BOX type combined sewer pipes and the Yongunchen outfall not having seperatioin wall. The average flow-weighted BOD concentraion in Yongunchen outfall is 2-fold lower than in Daesachen outfall because of the dilution effect from ravine water. However, the pollutant mass loading is 16 fold higher in Yongunchen outfall than in Daesachen outfall because of more flows. According to the research, the separation wall controls 52% pollutant mass during a storm period (11.5 mm/hr rainfall intensity). Therefore, the Yongunchen combined sewer system (CSS) need separation wall to control and to prevent more pollutant input in stream. In Daesachen area, the maximum sewer flow rate during a storm period measured about 10 fold bigger than average sewer flow during dry periods. Also the concentrations between rainy and dry periods increase approximately 33 fold for BOD and 120 fold for SS. In Yongunchen area, it increases about 9 fold for the maximum flow rate, 18 fold for BOD and 22 fold for SS during a storm. Therefore, the research is concluded that the separation wall between stromwater (or ravine water) and sewage can decrease the dilution effect in CSS and control the pollutant loading.

상향류식 바이오비드 공법을 이용한 오·폐수 처리특성 및 부착 생물막의 형태적 특징 (Treatment Kinetics of Wastewater and Morphological Characteristics of Biofilm in Upflow Biobead® Process)

  • 염규진;이정훈;김선미;최원석
    • 한국물환경학회지
    • /
    • 제18권2호
    • /
    • pp.201-212
    • /
    • 2002
  • The objective of this study was to investigate the treatment efficiency, kinetics, and morphological characteristics of biofilm in upflow $Biobead^{(R)}$ process, a kind of biological aerated filter(BAF). The $Biobead^{(R)}$ system showed high removal rates of $COD_{Mn}$(76~83%), $BOD_5$(67~88%) and SS(71~91%) for food wastewater with high salt concentration ($>4,000mg/{\ell}$) under short reaction times(2~3hrs). Even at aerobic condition, the system had high treatment efficiency for both T-N (51~63%) and T-P(62~81%). The removal kinetics of $COD_{Mn}$, $BOD_5$, T-N, T-P, and $Cl^-$ in the $Biobead^{(R)}$ system showed a plug-flow pattern with reaction rate constants($hr^{-1}$) of 0.58, 0.63, 0,30, 0.48, and 0.38 respectively. A backwashing process to remove excess biomass and filtered solids was needed at least once during 22-hour operation at $0.5kg\;BOD\;m^{-3}{\cdot}d^{-1}$ loading. At the higher loading($1.0kg\;BOD\;m^{-3}{\cdot}d^{-1}$) the backwashing interval was shorten by 8 hours. The COD, BOD, T-N, and T-P were removed from 43 to 66% only by aerobic biodegradation. The SS was removed over 70% by the filtering of $Biobead^{(R)}$ media in the treatment system. The first one of three serial Biobead reactors showed the highest removal values for $COD_{\alpha}$(52.3%), $COD_{Mn}$(38.8%), BOD(62.5%), and T-N(40.0%). The SS and T-P had the highest removal values(47.5% and 29.2%) at the second one of the serial reactors. The biofilm had non-homogeneous spatial distribution and the colonies were embedded in the sunk area of the Biobead. The thickness of the biofilm was very thin ($5.0{\sim}29.4{\mu}m$) compared to the biofilm thickness($200{\sim}300{\mu}m$) used in other BAF systems.

강우시 비점오염원의 오염부하 특성 - 벚나무 재배지를 대상으로 - (Loading Characteristics of Non-Point Source Pollutants by Rainfall - Case Study with Cherry Tree Plot -)

  • 강미아;최병우;유재정
    • 지질공학
    • /
    • 제20권4호
    • /
    • pp.401-407
    • /
    • 2010
  • 농업지역에서 발생한 오염부하량을 결정하기 위해 여러 토지이용형태 중에서 벚나무 재배지(단위 비점오염원)에서 발생하는 오염부하 특성을 조사하였다. 유출시 발생된 강우사상에서는 강우량과 유출수량의 상관계수가 0.5로 낮게 나타나 투수성을 예측할 수 없는 수준이었다. 강우량 20mm 미만인 경우에도 강우강도가 8.8 mm/hr 수준으로 높은 경우에는 유출이 발생하였으나 강우량이 47.4 mm로 많은 경우라 할지라도 긴 무강우일수와 약한 강우강도를 보인 경우에는 유출이 발생하지 않았다. 강우사상시 발생된 유출량과 SS, BOD, COD, TN 및 TP 오염부하량과의 상관계수는 SS에서 최저값 0.71을 보인 것 이외에는 모두 r ${\geq}$ 0.92로 매우 유의한 값을 나타냈다. 한편 SS와 다른 오염물질간의 오염부하상관성도 모두 r ${\geq}$ 0.73의로 유의한 값을 나타내었으므로 SS관리를 통해 유기물질과 영양염에 대한 제어도 가능함을 알 수 있다. 최고 TN농도는 시비활동에 의해 직접적 영향을 받은 Event의 유출수에서 발생하였다. 따라서 농경지에서 발생하는 유출수의 오염수준을 평가할 때에는 시비여부를 반드시 고려해야 할 것이다.

분류식 하수관거로의 전환시 유입하수의 성상 변화 및 선회와류식 SBR공법의 처리 특성 (Change in Influent Concentration of Domestic Wastewater from Separated Sewer and Biological Nitrogen and Phosphorus Removal of a Full Scale Air-vent SBR)

  • 이장희;강호
    • 한국물환경학회지
    • /
    • 제28권1호
    • /
    • pp.63-70
    • /
    • 2012
  • This study was carried out to investigate change in influent concentration of domestic wastewater flowed from a newly constructed separate sewer system (SSS) and biological nutrients removal efficiency of a full scale Air-vent sequential batch reactor (SBR, $600m^3/d$). The average concentration of $BOD_5$, SS, T-N and T-P from SSS were 246.5 mg/L, 231.6 mg/L, 42.974 mg/L, 5.360 mg/L, respectively which corresponds to 2.2times, 1.2times, 1.8times and 2.1times higher than those from the conventional combined sewer system (CSS). The removal efficiency of $BOD_5$, SS, T-N, and T-P for the Air-vent SBR operated with influent from SSS averaged 99.1%, 99.0%, 91.2%, and 93.5%, respectively. Especially the respective nitrogen and phosphorus removal was 15% greater than that of the SBR operated with influent from CSS. Simultaneous nitrification and denitrification (SND) was observed in an aerobic reactor(II) as a result of DO concentration gradient developed along the depth by the Air-vent system. In order to achieve T-N removal greater than 90%, the C/N ratio should be over 6.0 and the difference between $BOD_5$ loading and nitrogen loading rate be over 100 kg/day (0.130 kg $T-N/m^3{\cdot}d$). Even with high influent T-P concentration of 5.360 mg/L from SSS (compared with 2.465 mg/L from CSS) T-P removal achieved 93.5% which was 15.5% higher than that of the SBR with influent from CSS. This is probably due to high influent $BOD_5$ concentration from SSS that could provide soluble carbon source to release phosphorus at anaerobic condition. In order to achieve T-P removal greater than 90%, the difference between $BOD_5$ loading and phosphorus loading rate should be over 100 kg /day (0.130 kg $T-N/m^3{\cdot}d$).

회전원판공정과 화학침전공정 조합을 이용한 유기물과 질소*인의 동시제거 (Integrated System of RBC-lime Precipiatation for Simultaneous Removal of Organics and Nutrients)

  • 박종안;허준무;손부순
    • 한국환경보건학회지
    • /
    • 제24권1호
    • /
    • pp.132-140
    • /
    • 1998
  • 회전원판공정(rotating biological contactorRBC)과 화학적 처리공정을 결합한 처리시스템을 이용하여 도시하수내 포함된 유기물과 영양염류를 제거할 경우에 수리학적 부하 (hydraulic loading)와 처리수 반송율 (recirculation rate)의 시스템 처리효율에 미치는 영향을 알아보고자 하였다. 각각의 수리학적 부하 0.031, 0.0535 및 0.076 $m^3/m^2/d에서 반송율을 100%, 200%, 300%로 변화시켰고, 질산화에 필요한 알카리도의 보충 및 화학적 처리를 위하여 lime(CaCO$_3$)을 가하여 유입수의 pH를 10.4-11.0으로 유지시켰다. 실험결과 수리학적 부하 0.0535 $m^3/m^2/d에서 BOD, COD의 제거효율이 가장 높게 나타났으며, 질산화 효율 및 질소 제거효율에서는 수리학작 부하 0.035 $m^3/m^2/d, 반송율 300%에서 가장 높았으며, 반송율별에서는 수리학적 부하를 고려할 때 300% 반송하는 것이 가장 높은 유기물 제거효율을 보였다. 반송율과 수리학적 부하를 증가시킬 경우에 발생되는 슬러지내 유기물 함량은 점점 증가하였고, 수리학적 부하 0.076 $m^3/m^2/d, 반송율 300%일 경우에는 유기물 함량이 47%로 매우 높았다. 이는 부하증가에 따른 미생물 성장의 증가와 더불어 수리학적 부하 증가에 따른 전단력의 증가가 영향을 미쳤기 때문이다. 인을 제거하기 위하여 pH를 10.4-11.0으로 유지시킨 경우에 인을 90%이상 제거할 수 있었으며, 유출수내 평균 SS농도는 40 mg/l를 상회하였다.

  • PDF

낙동강 지류·지천 모니터링 결과를 이용한 수질환경 평가 (Water Quality Analysis in Nakdong River Tributaries)

  • 임태효;손영규
    • 한국환경과학회지
    • /
    • 제25권12호
    • /
    • pp.1661-1671
    • /
    • 2016
  • Water quality in Nakdong river was analyzed using 699 monitoring data sets including flow rates and water quality concentrations collected at 195 tributary monitoring stations (the priority management areas: 35 stations, the non-priority management areas: 160 stations) in 2015. The highest average concentrations of all data for BOD, COD, T-N, T-P, SS, and TOC were 30~600 times higher than the lowest concentrations while the highest average loading rates were 800,000~2,700,000 times higher than the lowest loading rates. Because of the very large differences in the concentrations and loading rates, the variation of the concentrations and loading rates in a priority management monitoring station for BOD, T-P, and TOC was analyzed using the coefficient of variation, the ratio of the standard deviation value to the mean value. For BOD, T-P, and TOC, the coefficients of variation for concentration were mostly less than 100%, whereas the coefficients of variation for loading rate ranged from 31.1% to 232.2%. The very big difference in the loading rates was due to the large variation in flow rates. As a result of this, the estimation of water quality at each monitoring station using the average values of the concentrations and loading rates might be not rational in terms of their representativeness. In this study, new water quality analysis methods using all collected monitoring data were suggested and applied according to the water quality standard in medium-sized management areas.